Abstract
Museums, archives and libraries have large working environments. The goal of this study was to determine microbial contamination in these work places and estimate the influence of microclimatic parameters and total dust content on microbial contamination. In addition, research included evaluation of ergosterol concentration and fungal bioaerosol particle size distribution. Numbers of micro-organisms in the air and on the surfaces in museums were higher (2.1 × 102–7.0 × 103 cfu/m3 and 1.4 × 102–1.7 × 104 cfu/100 cm2, respectively) than in archives and libraries (3.2 × 102–7.2 × 102 cfu/m3 and 8.4 × 102–8.8 × 102 cfu/100 cm2, respectively). The numbers of micro-organisms detected in the tested museums, archives and libraries did not exceed occupational exposure limits proposed by Polish Committee for the Highest Permissible Concentrations and Intensities of Noxious Agents at the Workplace. The concentrations of respirable and suspended dust in museum storerooms were 2–4 times higher than the WHO-recommended limits. We found a correlation between microclimatic conditions and numbers of micro-organisms in the air in the tested working environments. In addition, a correlation was also found between ergosterol concentration and the number of fungi in the air. Fungi were the dominant micro-organisms in the working environments tested. Particles within the dominant fractions of culturable fungal aerosols sampled from museum storerooms had aerodynamic diameters between 1.1 and 2.1 µm.
Keywords: Micro-organisms at workplaces, Ergosterol, Bioaerosol, Microclimatic parameters, Museum, Archive, Library
Introduction
Museums, archives and libraries are institutions that are crucial for preserving cultural heritage all over the world. Given the number of such institutions, they also contribute from 0.5 to 2.6 % of total employment (based on the data of the Polish Central Statistical Office [GUS] 2012), thus constituting a significant proportion of working environments (for archivists, curators, librarians, conservators, storeroom workers and office staff). Previous microbiological analyses in museums, libraries and archives have shown high microbial air contamination, which may pose a danger to historical objects and also to staff (Gysels et al. 2004; Zielińska-Jankiewicz et al. 2008; Mesquita et al. 2009; Karbowska-Berent et al. 2011; Skóra et al. 2012).
Health threats in these institutions arise due to the inhalation of the micro-organism-contaminated air and by handling, cleaning and conserving items many of which are mould infested. Wiszniewska et al. (2009) identified allergy to fungi in 31 % of staff working at the National Museum in Warsaw (number of subjects studied n = 103). Moreover, workers’ exposure to micro-organisms may have additional consequences such as infections and mycotoxicoses. Mycotoxins produced by fungi (e.g. Aspergillus flavus, A. parasiticus, A. versicolor, Penicillium chrysogenum, P. expansum, Stachybotrys chartarum) often isolated from museums, libraries and archive facilities are known to have harmful effects (Halstensen 2008; Eduard 2009). Mycotoxins and microbial volatile organic compounds (MVOC’s) might constitute aetiological factors in sick building syndrome (SBS) (Korpi et al. 2009).
Comprehensive data describing the problem of microbial contamination in museums, libraries and archive rooms are not available. Obtaining such data is a difficult task due to the varying conditions of each institution (different collections of objects, microclimatic parameters, concentration of dust), which may impact the levels and types of micro-organisms. The goal of the present study was to determine microbial contamination in the above institutions. The study was designed to answer the following questions: Do museums, archives and libraries have similar levels and types of microbial contamination? What influence do temperature, relative humidity and concentration of dust in the air have on micro-organism numbers within these premises? Is ergosterol a good measure of fungal contamination in museums, archives and libraries? What are the risks to workers inhaling bioaerosol within these premises?
Materials and methods
Description of the studied rooms
Microbiological contamination was analysed in four museums, two libraries and two archives (total of 22 rooms) located in Poland. Descriptions of tested rooms are presented in Table 1. The temperature and humidity of the air in the tested rooms were determined using a PWT-401 hygrometer (Elmetron, Poland). Dust content was measured using a DustTrak DRX Aerosol Monitor (model 8533, TSI, USA). Simultaneously, measurements of size-segregated mass fraction concentrations corresponding to PM2.5 (diameter less than <2.5 μm), PM10 (<10 μm) size fractions and total dust were taken.
Table 1.
Institution | Room | Cubature (m3) | Average temperature (°C) | Average relative humidity (%) | Total dust concentration (mg/m3) | Rooms description |
---|---|---|---|---|---|---|
Museum I | Restoration workshop 1 | 300 |
M: 19.5 SD: 3.8 |
M: 29.0 SD: 3.6 |
M: 0.189 SD: 0.227 |
Washing, drying and preliminary textile repair, no signs of moisture or moulds |
Restoration workshop 2 | 1200 | Textile repair, no signs of moisture or moulds | ||||
Warehouse 1 | 1215 | Department of textile technology (“Gateway”)—collects machine (wood, steel) for processing fibres, mainly cotton and linen, no signs of moisture or moulds | ||||
Warehouse 2 | 456 | Historic fabric warehouse—a collection of materials on wooden and steel shelves, no signs of moisture or moulds | ||||
Museum II | Warehouse 1 | 281 |
M: 19.0 SD: 1.0 |
M: 41.0 SD: 3.6 |
M: 0.131 SD: 0.030 |
Collection of paintings on gantries, weapons (swords, rifles, pistols), explicit signs of moisture and moulds |
Warehouse 2 | 220 | Collection of flags, banners gathered in wooden dressers, explicit signs of moisture and moulds | ||||
Warehouse 3 | 52 | Collection of flags, banners gathered in wooden dressers, explicit signs of moisture and moulds | ||||
Museum III | Warehouse 1 | 310 |
M: 13.3 SD: 3.1 |
M: 39.7 SD: 4.7 |
M: 0.373 SD: 0.105 |
Furniture warehouse, department of folk art—collection of wooden furniture, sculptures, some signs of moisture on objects and walls |
Warehouse 2 | 1362 | Section of farm and rural industry—collection of materials such as wood, wicker, iron, derived mostly from the second half of nineteenth and twentieth centuries, no signs of moisture or moulds | ||||
Warehouse 3 | 60 | Magazine of African cultures—two part room, collection of clothing, masks, weapons, sculptures no signs of moisture or moulds | ||||
Museum IV | Warehouse 1 | 222 |
M: 22.0 SD: 0.8 |
M: 35.5 SD: 11.1 |
nt | Cabinet of polish prints and drawing, no signs of moisture or moulds |
Warehouse 2 | 725 | Art warehouse—collection of oil paintings on canvas and board, no signs of moisture or moulds | ||||
Warehouse 3 | 171 | Mediaeval art restoration workshop—work only with wood, no signs of moisture or moulds | ||||
Exhibition hall | 3055 | Ancient art gallery—collection of sculptures from this period, no signs of moisture or moulds | ||||
Archive I | Warehouse 1 | 222 |
M: 22.0 SD: 1.0 |
M: 36.2 SD: 3.2 |
nt | The oldest room gathers records of Łódź since 1884 on metal shelves. The files are packed in protective cartons, no signs of moisture or moulds |
Warehouse 2 | 236 | Books and map of Łódź and its region, archival photographs, windows in the room are covered in order to reduce exposure of sets, no signs of moisture or moulds | ||||
Archive II | Warehouse 1 | 405 |
M: 19.3 SD: 1.5 |
M: 31.5 SD: 7.4 |
M: 0.073 SD: 0.011 |
Files, maps and books from nineteenth century factories, court records from nineteenth to twentieth centuries no signs of moisture or moulds |
Warehouse 2 | 176 | Files maps and books from nineteenth century factories, court records from nineteenth to twentieth centuries no signs of moisture or moulds | ||||
Library I | Warehouse 1 | 222 |
M: 23 SD: 0.8 |
M: 51.4 SD: 7.4 |
M: 0.158 SD: 0.103 |
Metal shelves with books, room sealed, new plastic window, no signs of moisture or moulds |
Warehouse 2 | 69 | Basement, wooden bookshelves, lack of ventilation, signs of water damage on the walls, flaky paint, destroyed by moulds book on the floor, no signs of moisture or moulds | ||||
Library II | Warehouse 1 | 123 | M: 18.5 | M: 27.3 | M: 0.035 | Books from nineteenth to twentieth centuries, no signs of moisture or moulds |
Warehouse 2 | 138 | SD: 0.7 | SD: 1.0 | SD: 0.006 | Books and periodicals from nineteenth to twentieth centuries, no signs of moisture or moulds | |
Office rooms in the tested institutions | 52–78 |
M: 21.6 SD: 2.3 |
M: 37.0 SD: 11 |
M: 0.108 SD: 0.049 |
Office equipment, cabinets and shelves for documents, no signs of moisture or moulds |
M arithmetic mean; SD standard deviation; nt not tested
Determination of microbiological contamination of air and surfaces
Air Sampler MAS-100 Eco (Merck, Germany) was used for air sampling. Air samples of 50 and 100 L were taken on DG18 agar medium (Dichloran Glicerol Selective Medium, Merck, Germany) and MEA medium (Malt Extract Agar, Merck, Germany) with chloramphenicol (0.1 %) for determining total fungal number (including xerophilic and hydrophilic fungi) and on a TSA medium (Tryptic Soy Agar, Merck, Germany) with nystatin (0.2 %) for determining total bacterial number. Air samples were collected in two sequential repetitions on each medium, in three locations in each room using a single sampler. Samples were collected in winter 2011 (between November and February), during one working day, when staff were performing routine activities in the tested museums, archives and libraries.
Office rooms were analysed as internal backgrounds for each site (three repetitions on each medium), and the atmospheric air outside each building site was analysed as the external background (three repetitions on each medium). Bioaerosol particle sizes were determined from samples collected in rooms with the highest level of fungal contamination (storerooms in Museum II), since they might pose the greatest health risk to employees. Samples for determining particle size distribution of fungal bioaerosol were collected from selected museum storerooms, an office room (internal background) and atmospheric air (external background), using a six-stage Andersen sampler (model WES-710, Westech Instruments, UK). Samples were collected over 5 min (141.5 l of air) on MEA medium with chloramphenicol (0.1 %) in two repetitions on each medium in three places in room.
Samples from surfaces were collected using Envirocheck® plates (Merck, Germany) on TSA medium with neutralizers (for bacteria) and on Sabouraud medium (for fungi). For highly contaminated surfaces, the traditional swab method was applied, using saline solution (0.85 % NaCl), swabs, metal frames of 25 cm2 surface area and the media described above. Samples were collected from 3 to 5 surfaces (furniture, walls, books and stored objects) on each medium, in every room (total number of samples in a given institution: 10–15). The samples were incubated at 30 ± 1 °C for 48 h (bacteria) or at 27 ± 1 °C for 5 days (fungi). After incubation, the colonies were counted, and the results were expressed in cfu/m3 (air) or cfu/100 cm2 (surfaces). The final results are presented as the arithmetic mean of all repetitions.
Identification of bacteria and yeasts
All bacteria and yeasts isolated from samples were transferred onto individual culture plates. Following this, they were macroscopically and microscopically characterized using Gram-staining, catalase test and oxidase test (Microbiologie Bactident Oxydase, Merck, Germany). Next, isolates with the same morphology and biochemical features were grouped into strains and identified using API tests (BioMérieux, France): API 50 CH, API STAPH and API 20 NE (for bacteria) and API C AUX (for yeasts). Identified bacteria were genetically confirmed using the 16S rRNA gene nucleotide sequence (Jensen et al. 1993).
Isolated filamentous fungi were cultured on CYA (Czapek Yeast Extract Agar, Difco, USA) and YES medium (yeast extract with supplements) and visually identified, macroscopically and microscopically, using taxonomic keys (Bensch et al. 2012; Frisvad and Samson 2004; Pitt and Hocking 2009; Klich 2002). Identity of moulds and yeasts was confirmed using ITS1/2 sequence of the rDNA region (White et al. 1990). Genomic DNAs were extracted using a method described previously (Stępień et al. 2011). The resulting nucleotide sequences of the studied micro-organisms were analysed and compared to the sequences published in the National Center for Biotechnology Information (NCBI) database, using the BLASTN 2.2.27+ program (Zhang et al. 2000).
Ergosterol determination
Air samples for ergosterol determination were collected using an AirPort MD8 sampler (Sartorius, Germany). In total, 1000-L samples (six repetitions) were collected on sterile gelatine filters (pore diameter 0.3 µm, Sartorius, Germany). Ergosterol was quantified based on Miller and Young’s (1997) method using a modified analytical procedure. Chromatographic analysis (gas chromatography with flame ionization detection—GC-FID) was carried out using a GC apparatus (Agilent 6890N HP, USA). Quantitative analysis was performed using an external standard (external calibration) method, with software from Agilent ChemStation (USA).
Statistical analyses
Statistical analyses were performed using STATISTICA 6.0 software (Statsoft, USA). All results were evaluated using one-way analysis of variance (ANOVA) at the 0.05 significance level. When statistical differences were detected (p < 0.05), means were compared by the post hoc Fisher’s test at 0.05 significance level.
Linear regression analysis was used to determine the effect of air humidity and temperature and total dust on microbiological contamination of the air and surfaces in tested buildings. Linear regression analysis was also used to determine the effect of air and surface microbiological contamination on ergosterol concentration in the air. The significance tests were performed at the 0.05 significance level using Guilford’s correlation scale (Stanisz 2006).
Results
The number of micro-organisms in the air in museums averaged from 2.1 × 102 to 7.0 × 103 cfu/m3 and on the surfaces from 1.4 × 102 to 1.7 × 104 cfu/100 cm2 (Figs. 1, 2). Museum IV had the lowest level of air and surface microbiological contamination (high standards of hygiene, monitoring system for microclimatic parameters, museum of national rank). The highest concentration of bacteria was found in the air of Museum III, whose collections consist of folk culture objects (mainly made of wood and fabric). The highest statistically significant (p < 0.05) fungal contamination was found in Museum II, a war memorial museum (collections of paintings, firearms, weapons and flags). The fungal concentration in the rooms of that museum was 20 times greater than in the atmospheric air (p < 0.05).
The level of microbial contamination in the air of archives and libraries ranged from 4.9 × 102 to 5.6 × 103 cfu/m3, while the number of surface micro-organisms was between 8.4 × 101 and 3.9 × 103 cfu/100 cm2. Amongst institutions of this type, the highest microbiological air contamination was found in Library I (rooms with signs of moisture and moulds on walls and books). The air of this library had higher concentrations of airborne fungi compared to other similar institutions (5.3 × 103 cfu/m3, p < 0.05).
The number of micro-organisms on the surfaces was low, and the collected materials in most institutions did not have active microbial growth; except Museum II, Archive II had high levels of contamination on objects. However, there were no statistically significant differences in the levels of fungi (except Museum II) and bacteria (except Archive II) on the surfaces in the tested buildings (p > 0.05).
The concentrations of ergosterol ranged from 0.41 to 0.69 ng/m3 (Fig. 3). The highest level of ergosterol was found in Museum III and Library II, which may indicate problems with fungal infestation. The lowest concentration of ergosterol (0.41–0.46 ng/m3) was found in archive rooms.
Regression analysis revealed high positive correlations between ergosterol concentrations and numbers of fungi in the air in museums (r = 0.787–0.829, p < 0.05) and archives (r = 0.776–0.939, p < 0.05). Results of regression analysis undertaken for libraries indicate a moderate influence of fungal contamination on ergosterol concentration in Library I (r = 0.482, p < 0.05); however, the significance coefficient calculated for Library II (r = 0.311, p > 0.05) shows no correlation between the examined values.
The concentration of ergosterol in the air and the number of fungi on the surfaces in two workplaces had moderate correlation: Museum I (r = 0.490, p < 0.05) and Archive I (r = 0.461, p < 0.05). All other institutions examined showed no correlation between these two parameters (significance levels p > 0.05). The influence of microclimate parameters on the number of micro-organisms in the air was tested. The correlation between the temperature and number of micro-organisms in air samples was high (r = 0.610–0.863, p < 0.05) in 7/8 institutions. Regression coefficients describing the effect of air humidity on microbial concentration showed high correlations (r = 0.690–0.971, p < 0.05) in 6/8 institutions.
Significant correlations (p < 0.05) were also observed between microclimatic parameters and the number of surface micro-organisms in 6/8 institutions; correlation coefficient (r) equalled from 0.412 to 0.890 and from 0.428 to 0.906 for temperature and humidity, respectively. No significant correlations (p > 0.05) were found in two institutions (Library II and Museum IV).
The impact of total dust concentrations on air microbial contamination levels was determined. In museums and libraries, linear regression results showed high correlation between these parameters. This was confirmed by high correlation coefficients, which ranged from 0.794 to 0.908 (p < 0.05) for all workplaces except Archive 1. Correlation in Archive 1 was not significant (r = 0.351, p > 0.05).
Moreover, the concentration of respirable dust (particle diameter <2.5 µm) in museum storerooms ranged between 0.100 and 0.105 mg/m3, which was higher than office rooms (internal background samples) (Fig. 4).
The dominant fraction of culturable fungal aerosol in museum storerooms had aerodynamic diameters between 1.1 and 2.1 µm (fraction V), and it accounted for 40–42 % of the fungal bioaerosols, depending on the room. One of the storerooms (Storeroom 3) had a large contribution from fraction IV (36 %), consisting of particles with aerodynamic diameters of 2.1–3.3 µm. This was also the dominant fraction culturable fungal aerosol in samples from office rooms (internal background), while the greatest percentage contribution from atmospheric air (external background) came from particles measuring 3.3–4.7 µm (fraction III) (Fig. 5).
A total of 16 bacterial strains were isolated from museum premises, 13 from archives and 13 from libraries (Table 2). Bacteria from the Micrococcus, Staphylococcus and Bacillus genera dominated each institution type, while other species of bacteria were specific to particular buildings. Qualitative composition of fungi varied in tested environments: 32 species of fungi (28 moulds and 4 yeasts) were isolated in museums, 24 species (21 moulds and 3 yeasts) in archives and 34 (32 moulds and 2 yeasts) in libraries (Table 2). The most common fungi were as follows: Aspergillus puulaaensis, Cladosporium cladosporioides, Penicillium crustosum, Rhizopus oryzae. However, there were distinct differences in air and surface fungal composition between institutions. It is worth emphasizing that 45 amongst the 89 isolated micro-organisms are potential pathogens according to classifications of the Directive UE 2000/54/WE, Regulation of the Minister of Health in Poland dated 22 April 2005, the European Confederation of Medical Mycology (BSL) and the Institute of Rural Health in Lublin (IMW). These belong to the genera: Bacillius, Pseudomonas, Alternaria, Aureobasidium, Aspergillus, Chaetomium, Chrysonilia, Cryptococcus, Cladosporium, Paecilomyces, Mucor, Penicillium, Talaromyces and Trichoderma (Table 2).
Table 2.
Micro-organism | Frequency of isolation of all samples in each institution [%] Air/surfaces |
|||||||
---|---|---|---|---|---|---|---|---|
Museum I | Museum II | Museum III | Museum IV | Archive I | Archive II | Library I | Library II | |
Bacteria | ||||||||
Aneurinibacillus aneurinilyticus | 0/0 | 0/0 | 0/0 | 0/0 | 0/0 | 0/0 | 0/0 | 0/33.3 |
Bacillus circulans | 0/0 | 0/0 | 0/0 | 0/0 | 0/0 | 0/0 | 22.2/0 | 0/0 |
Bacillus firmus | 75.0/0 | 0/0 | 0/0 | 0/0 | 0/0 | 0/0 | 0/0 | 0/0 |
Bacillus licheniformis | 0/0 | 0/0 | 0/0 | 0/0 | 0/0 | 21.4/0 | 0/0 | 8.3/33.3 |
Bacillus megaterium | 0/0 | 0/0 | 0/58.3 | 0/0 | 0/41.7 | 0/0 | 0/0 | 0/0 |
Bacillus mycoides | 0/0 | 0/0 | 0/0 | 0/0 | 0/0 | 0/0 | 0/80 | 0/0 |
Bacillus pumilus | 0/55.0 | 0/0 | 0/75.0 | 0/62.5 | 0/0 | 21.4/26.3 | 0/45 | 8.3/0 |
Bacillus sp. | 0/66.7 | 0/0 | 0/0 | 0/0 | 0/0 | 0/0 | 0/0 | 0/0 |
Bacillus subtilis | 0/44.4 | 0/0 | 0/66.7 | 0/0 | 0/0 | 21.4/10.5 | 0/0 | 33.3/33.3 |
Brevibacillus laterosporus | 0/50.0 | 0/0 | 0/0 | 0/0 | 0/0 | 0/0 | 0/0 | 0/0 |
Kocuria kristinae | 0/0 | 0/0 | 0/0 | 0/0 | 0/0 | 0/0 | 22.2/0 | 0/0 |
Kocuria varians/rosea | 75.0/0 | 0/0 | 0/0 | 0/0 | 0/0 | 0/0 | 0/0 | 0/0 |
Lactobacillus delbrueckii | 0/50.0 | 0/50.0 | 0/0 | 0/0 | 0/0 | 0/0 | 0/0 | 0/0 |
Leuconostoc mesenteroides | 0/0 | 0/0 | 0/0 | 0/0 | 61.1/0 | 0/0 | 0/0 | 0/0 |
Micrococcus flavus | 0/0 | 0/0 | 0/0 | 0/0 | 0/0 | 92.9/0 | 0/0 | 0/0 |
Micrococcus sp. | 95.9/83.3 | 100.0/0 | 86.1/16.7 | 95.9/56.3 | 100/41.7 | 0/0 | 66.7/0 | 100/0 |
Micromonospora sp. | 0/0 | 0/0 | 0/0 | 0/0 | 0/0 | 0/26.3 | 0/0 | 0/0 |
Nocardia sp. | 0/0 | 0/0 | 0/0 | 0/0 | 0/0 | 21.4/0 | 0/0 | 41.7/0 |
Paenibacillus polymyxa | 0/0 | 0/0 | 0/91.7 | 0/0 | 0/0 | 0/0 | 0/0 | 0/0 |
Pseudomonas alcaligenes | 0/0 | 75.0/0 | 0/0 | 0/0 | 0/0 | 0/0 | 22.2/0 | 0/0 |
Pseudomonas stutzeri | 0/0 | 0/0 | 0/0 | 0/0 | 0/0 | 0/0 | 27.8/0 | 0/0 |
Pseudomonas oryzyhabitans | 0/0 | 0/0 | 0/0 | 0/0 | 38.9/0 | 0/0 | 0/0 | 0/0 |
Sphingomonas paucimobilis | 0/0 | 0/0 | 0/0 | 0/50.0 | 0/0 | 0/0 | 0/0 | 0/0 |
Staphylococcus haemolyticus | 0/0 | 0/0 | 100.0/0 | 0/0 | 0/0 | 0/0 | 0/0 | 0/0 |
Staphylococcus cohnii | 0/0 | 0/0 | 0/0 | 0/0 | 94.4/0 | 0/0 | 0/0 | 0/0 |
Staphylococcus hominis | 91.7/0 | 0/0 | 0/0 | 0/0 | 0/0 | 0/0 | 0/0 | 0/0 |
Staphylococcus lentus | 0/0 | 100.0/0 | 0/0 | 0/0 | 0/0 | 0/26.3 | 100/0 | 66.7/0 |
Staphylococcus xylosus | 75.0/0 | 0/0 | 0/0 | 0/0 | 0/0 | 0/21 | 0/0 | 33.3/0 |
Fungi | ||||||||
Acremonium furcatum | 0/0 | 0/0 | 0/0 | 0/0 | 5.6/0 | 0/0 | 0/0 | 0/0 |
Acremonium verticillium | 0/0 | 0/0 | 0/0 | 0/0 | 0/0 | 0/0 | 11.1/0 | 0/0 |
Alternaria alternata | 0/14.3 | 0/0 | 0/0 | 0/43.8 | 0/0 | 7.1/0 | 0/35 | 0/0 |
Alternaria consortiale | 0/14.3 | 0/0 | 0/0 | 0/0 | 0/0 | 0/0 | 5.6/0 | 16.7/0 |
Alternaria sp. | 0/0 | 0/0 | 0/0 | 0/0 | 0/0 | 14.3/0 | 0/0 | 0/0 |
Alternaria tennuissima | 0/0 | 0/0 | 0/0 | 0/0 | 0/0 | 0/0 | 33.3/15 | 0/0 |
Aspergillus clavatus | 0/0 | 0/0 | 0/0 | 0/0 | 0/0 | 0/0 | 5.6/0 | 0/0 |
Aspergillus flavus | 0/0 | 0/0 | 0/0 | 0/12.5 | 0/0 | 0/0 | 0/0 | 0/12.5 |
Aspergillus fumigatus | 0/0 | 0/0 | 0/0 | 0/0 | 0/0 | 7.1/0 | 0/0 | 0/0 |
Aspergillus niger | 20.8/28.6 | 0/12.5 | 0/0 | 4.2/0 | 0/0 | 7.1/0 | 16.7/15 | 8.3/0 |
Aspergillus ochraceus | 0/0 | 0/0 | 0/0 | 8.3/0 | 0/0 | 0/0 | 0/15 | 0/0 |
Aspergillus parasiticus | 0/0 | 0/0 | 0/27.3 | 0/0 | 0/0 | 0/0 | 0/0 | 0/0 |
Aspergillus puulaaensis | 25.0/0 | 0/50.0 | 61.1/0 | 4.2/0 | 0/0 | 14.3/11.1 | 0/0 | 58.3/0 |
Aspergillus terreus | 0/0 | 0/0 | 0/0 | 12.5/0 | 0/0 | 0/0 | 0/0 | 0/0 |
Aspergillus wentii | 0/0 | 0/0 | 0/0 | 8.3/0 | 0/0 | 0/0 | 0/0 | 0/0 |
Aureobasidium pullulans | 0/0 | 0/0 | 0/0 | 4.2/0 | 0/0 | 0/0 | 0/0 | 0/0 |
Beauveria sp. | 0/0 | 0/0 | 0/0 | 0/0 | 11.1/0 | 0/0 | 0/0 | 0/0 |
Botrytis cinerea | 0/0 | 0/0 | 0/0 | 0/0 | 5.6/0 | 0/0 | 16.7/0 | 0/0 |
Botrytis sp. | 4.2/0 | 0/0 | 0/0 | 0/0 | 0/0 | 7.1/0 | 0/0 | 8.3/0 |
Chaetomium globosum | 0/0 | 0/0 | 0/0 | 0/0 | 0/0 | 0/0 | 0/10 | 0/0 |
Chrysonilia sitophila | 0/0 | 0/0 | 0/0 | 0/0 | 38.9/0 | 21.4/0 | 0/0 | 0/0 |
Cladosporium cladosporioides | 0/0 | 0/12.5 | 38.9/0 | 0/12.5 | 16.7/12.5 | 14.3/33.3 | 72.2/35 | 58.3/0 |
Cladosporium herbarum | 0/0 | 0/0 | 50.0/0 | 16.7/18.8 | 72.2/0 | 7.1/0 | 0/30 | 58.3/0 |
Cladosporium sp. | 4.2/0 | 0/0 | 0/0 | 0/0 | 0/0 | 0/0 | 0/0 | 0/0 |
Epicoccum nigrum | 0/0 | 0/0 | 0/0 | 0/0 | 0/0 | 0/0 | 16.7/0 | 0/0 |
Eurotium amstelodami | 0/0 | 0/0 | 0/0 | 0/0 | 0/0 | 0/0 | 0/25 | 0/0 |
Gliocladium sp. | 0/0 | 0/0 | 0/0 | 0/0 | 0/0 | 0/0 | 5.6/0 | 0/0 |
Mucor circinelloides | 0/0 | 0/0 | 0/0 | 0/6.3 | 0/0 | 0/0 | 0/10 | 0/12.5 |
Mucor globosus | 0/0 | 0/0 | 0/0 | 0/0 | 0/0 | 0/0 | 0/0 | 8.3/0 |
Mucor hiemalis | 8.3/0 | 0/0 | 0/0 | 0/0 | 0/0 | 0/0 | 0/0 | 0/0 |
Mucor plumbeus | 0/0 | 0/0 | 0/18.9 | 0/0 | 0/0 | 0/0 | 0/0 | 0/0 |
Mucor racemosus | 0/14.3 | 0/0 | 0/18.9 | 0/0 | 0/0 | 0/0 | 0/0 | 0/0 |
Mucor sp. | 0/0 | 0/0 | 0/0 | 0/0 | 0/0 | 0/0 | 0/0 | 8.3/0 |
Paecilomyces variotii | 0/0 | 0/0 | 0/0 | 0/31.3 | 0/0 | 0/44.4 | 0/0 | 0/0 |
Penicillium griseofulvum | 0/0 | 0/0 | 0/0 | 0/0 | 0/0 | 0/0 | 11.1/0 | 0/0 |
Penicillium chrysogenum | 0/7.1 | 0/25.0 | 0/0 | 8.3/18.8 | 0/0 | 0/0 | 27.7/20 | 0/0 |
Penicillium commune | 0/0 | 0/0 | 0/0 | 0/0 | 0/0 | 0/0 | 16.7/0 | 0/0 |
Penicillium corylophilum | 0/0 | 0/0 | 0/27.3 | 25.0/18.8 | 0/0 | 0/0 | 0/0 | 8.3/0 |
Penicillium crustosum | 45.8/57.1 | 0/12.5 | 5.6/36.4 | 0/0 | 0/0 | 28.6/11.1 | 33.3/0 | 33.3/50 |
Penicillium freii | 0/0 | 0/0 | 0/0 | 0/0 | 61.1/0 | 21.4/33.3 | 0/0 | 50/25 |
Penicillium gladioli | 0/0 | 0/0 | 0/0 | 20.8/0 | 0/0 | 0/0 | 0/0 | 0/0 |
Penicillium hirsutum | 0/0 | 0/0 | 0/0 | 0/0 | 5.6/0 | 0/0 | 0/0 | 0/0 |
Penicillium janthinellum | 0/0 | 0/0 | 0/0 | 4.2/62.5 | 0/0 | 14.3/11.1 | 0/0 | 0/0 |
Penicillium olsonii | 0/0 | 0/0 | 0/0 | 0/0 | 0/25.3 | 0/0 | 0/0 | 0/0 |
Penicillium oxalicum | 0/0 | 0/0 | 0/0 | 0/0 | 5.6/0 | 0/0 | 0/0 | 0/0 |
Penicillium radicola | 45.8/0 | 0/0 | 0/0 | 0/0 | 0/0 | 0/0 | 0/0 | 0/0 |
Penicillium sclerotigenum | 0/0 | 0/0 | 0/0 | 8.3/0 | 0/0 | 0/0 | 0/0 | 0/0 |
Penicillium viridicatum | 0/0 | 0/0 | 0/0 | 0/0 | 16.7/0 | 0/0 | 0/0 | 0/0 |
Penicillium waksmanii | 0/0 | 0/0 | 0/0 | 0/0 | 0/0 | 0/0 | 55.6/0 | 0/0 |
Rhizopus oryzae | 37.5/14.3 | 100/0 | 27.8/0 | 0/0 | 38.9/56.3 | 14.3/0 | 0/0 | 0/12.5 |
Talaromyces wartmannii | 0/0 | 0/0 | 0/0 | 0/0 | 0/0 | 0/0 | 0/10 | 0/0 |
Trichoderma koningii | 0/0 | 0/0 | 0/0 | 0/0 | 0/0 | 0/0 | 22.2/20 | 0/0 |
Trichoderma viride | 0/0 | 0/0 | 5.6/0 | 0/0 | 0/0 | 0/0 | 0/25 | 0/0 |
Ulocladium sp. | 0/0 | 0/0 | 0/0 | 0/0 | 0/0 | 0/0 | 5.6/0 | 0/0 |
Yeast | ||||||||
Candida sp. | 0/0 | 0/0 | 0/0 | 0/31.3 | 0/0 | 0/0 | 0/0 | 0/0 |
Candida sphaerica | 0/35.7 | 0/0 | 0/0 | 0/0 | 0/0 | 0/0 | 0/0 | 0/12.5 |
Cryptococcus humicola | 0/0 | 0/0 | 0/0 | 0/0 | 0/18.8 | 0/0 | 0/0 | 0/0 |
Cryptococcus laurentii | 0/0 | 0/0 | 0/0 | 0/0 | 0/0 | 0/0 | 22.2/0 | 0/0 |
Cryptococcus uniguttulatus | 0/0 | 0/0 | 0/0 | 0/0 | 0/6.3 | 0/0 | 0/0 | 0/0 |
Rhodotorula sp. | 0/0 | 0/0 | 0/9.1 | 0/0 | 0/0 | 0/11.1 | 0/0 | 0/0 |
Rhodotorula minuta | 0/0 | 0/0 | 0/0 | 0/6.3 | 0/0 | 0/0 | 0/0 | 0/0 |
Species that can constitute occupational threat according to the classification of the Directive UE 2000/54/WE, Regulation of the Minister of Health in Poland dated 22 April 2005, the European Confederation of Medical Mycology (BSL) and the Institute of Rural Health in Lublin (IMW) are bolded
Discussion
The buildings studied differed from each other in air contamination levels, which may be due to specific features and the condition of housed collections. Tested institutions had similar levels of surface microbial contamination (furniture, walls, stored objects). The levels of microbiological contamination in all institutions studied were lower than the threshold values of occupational exposure specified by the Polish Committee for the Highest Permissible Concentrations and Intensities of Noxious Agents at the Workplace, which is 5.0 × 104 cfu/m3 for the total fungal count (Skowroń and Górny 2012).
We found lower or similar microbial contamination in archives compared to previous studies (Borrego et al. 2010; Karbowska-Berent et al. 2011) and higher contamination in libraries and museums (Camuffo et al. 2001; Niesler et al. 2010; Karbowska-Berent et al. 2011).
Low ergosterol levels (0.41–0.69 ng/m3) in the air of studied rooms confirmed observations made by Gutarowska et al. (2014) for rooms with low fungal contamination. An ergosterol concentration above 1 ng per m3 can be considered as an indicator of excessive mould contamination of indoor air (103 cfu/m3) (Gutarowska et al., 2014). Our study found a significant correlation between the number of fungi in the air of museums and archives and ergosterol concentration. Ergosterol has been recommended previously as a good chemical indicator for evaluating mould concentrations in the air (Miller and Young 1997; Pasanen et al. 1999; Robine et al. 2005). No correlations were found between the number of fungi on the surfaces and ergosterol concentrations.
Steady microclimatic parameters, temperature of 20 ± 2 °C and relative air humidity of 50 ± 3 %, are recommended for collection storage in the studied institution types (ISO 11799:2003; Schäfer 2014). The temperature in 2/8 and the humidity in 7/8 institutions deviated from those specified in the standard. This was probably due to the lack of ventilation and air conditioning systems. There was an effect of humidity and temperature on microbial concentration in the air in majority of the facilities tested.
The highest concentration (0.38–0.39 mg/m3) of respirable dust, with particle sizes below 4 µm, was recorded in the rooms of Museum III. This concentration was 2–4 times higher than the 24-h exposure limits specified in the World Health Organization recommendations (WHO 2005). Fractions with aerodynamic diameters of 1.1–2.1 µm had the highest percentage contribution in fungal aerosols sampled from museum storerooms (Museum II). Based on spore sizes of the most frequently isolated fungal species, Aspergillus (2.1–3.6 µm), Penicillium (2.8–5.0 µm) and Cladosporium (2.5–7.5 µm), we conclude that fungi occurred as single cells, as spores or small fragments of mycelium.
Based on the dust level and particle size distribution data, the aerosol within the studied workplaces is able to penetrate the human respiratory system. This can happen via nasal and oral cavities, primary, secondary and terminal bronchi and the pulmonary bronchioles, with the solid particles present in dust acting as carriers. This may cause irritation of the mucous membranes of the nose and eyes, and an inflammatory response or allergic reactions (Kulkarni et al. 2011), in exposed employees.
Commonly detected micro-organisms in the tested institutions included: Micrococcus sp., Staphylococcus sp., Bacillus sp., Aspergillus puulaaensis, Cladosporium cladosporioides, Penicillium crustosum, Rhizopus oryzae. Previous studies by Karbowska-Berent et al. (2011), Niesler et al. (2010) have shown, inter alia, that these micro-organisms colonize museums, libraries and archival facilities.
Finally, most of the identified micro-organisms constitute an occupational threat according to the literature (Report of a Working Group on Hazardous Fungi of the European Confederation of Medical Mycology 1996; Directive UE 2000/54/WE, Regulation of the Minister of Health in Poland dated 22 April 2005, Dutkiewicz et al. 2007).
Factors such as dust concentration, diameter of fungal bioaerosol particles and the presence of potentially pathogenic micro-organisms should be taken into account in the microbiological assessment of working environments in museums, archives and libraries. Those factors may affect the health of workers; however, it requires further study.
Conclusions
The levels and types of micro-organisms within museums, archives and libraries were institution dependent. Micro-organism numbers within workspaces did not exceed recommended limits for occupational exposure. The concentrations of respirable and suspended dust in museum storerooms were 2–4 times higher than the WHO-recommended limits. Fungi were the dominant group of micro-organisms within tested working environments. The dominant fungal aerosol fractions had aerodynamic diameters that ranged between 1.1 and 2.1 µm in museum storerooms. We found a correlation between relative humidity and temperature and microbial contamination in the air. The concentration of ergosterol in the air in museum, archive and library workplaces strongly correlates with fungal concentrations in the air.
Acknowledgments
Studies were realized within the project of Polish National Center for Research and Development, no. III.B.03 “Development of principles for evaluation and prevention of hazards caused by biological agents in the working environment using indicators of microbial contamination”.
References
- Bensch K, Braun U, Groenewald JZ, Crous PW. The genus Cladosporium. Studies in Mycology. 2012;72(1):1–401. doi: 10.3114/sim0003. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Borrego S, Guiamet P, Gómez de Saravia S, Batistini P, Garcia M, Lavin P, et al. The quality of air at archives and the biodeterioration of photographs. International Biodeterioration and Biodegradation. 2010;64:139–145. doi: 10.1016/j.ibiod.2009.12.005. [DOI] [Google Scholar]
- Camuffo D, Van Grieken R, Busse HJ, Sturaro G, Valentino A, Bernardi A, et al. Environmental monitoring in four European museums. Atmospheric Environment. 2001;35:127–140. doi: 10.1016/S1352-2310(01)00088-7. [DOI] [Google Scholar]
- Directive 2000/54/EC of the European Parliament and of the Council of 18 September 2000 on the protection of workers from risks related to exposure to biological agents at work, Official Journal of the European Communities. L. 262/21, Brussels.
- Dutkiewicz J, Śpiewak R, Jabłoński L, Szymańska J. Biological occupational risk factors. Classification, exposed occupational groups, measurement, prevention. Lublin: Ad Punctum. Polish; 2007. [Google Scholar]
- Eduard W. Fungal spores: A critical review of the toxicological and epidemiological evidence as a basis for occupational exposure limit setting. Critical Reviews in Toxicology. 2009;39(10):799–864. doi: 10.3109/10408440903307333. [DOI] [PubMed] [Google Scholar]
- Frisvad JC, Samson RA. Polyphasic taxonomy of Penicillium subgenus Penicillium. A guide to identification of food and air-borne terverticillate penicillia and their mycotoxins. Studies in Mycology. 2004;49:1–174. [Google Scholar]
- GUS (Central Statistical Office) (2012). Branch Yearbooks. Yearbook of Labour Statistics. Warszawa: GUS
- Gutarowska B, Skóra J, Pielech-Przybylska K. Evaluation of ergosterol content in the air of various environments. Aerobiologia. 2014 doi: 10.1007/s10453-014-9344-4. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Gysels K, Delalieux F, Deutsch F, Grieken RV, Camuffo D, Bernardi A. Indoor environment and conservation in the Royal Museum of Fine Arts, Antwerp, Belgium. Journal of Cultural Heritage. 2004;5:221–230. doi: 10.1016/j.culher.2004.02.002. [DOI] [Google Scholar]
- Halstensen AS. Species-specific fungal DNA in airborne dust as surrogate for occupational mycotoxin exposure. International Journal of Molecular Sciences. 2008;9:2543–2558. doi: 10.3390/ijms9122543. [DOI] [PMC free article] [PubMed] [Google Scholar]
- ISO 11799:2003 Information and documentation—Documents to rage requirements for archive and library materials.
- Jensen MA, Webster JA, Straus N. Rapid identification of bacteria on the basis polymerase chain reaction—amplified ribosomal DNA spacer polymorphisms. Applied and Environmental Microbiology. 1993;59(4):945–952. doi: 10.1128/aem.59.4.945-952.1993. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Karbowska-Berent J, Górny RL, Strzelczyk AB, Wlazło A. Airborne and dust borne microorganisms in selected Polish libraries and archives. Building and Environment. 2011;46:1872–1879. doi: 10.1016/j.buildenv.2011.03.007. [DOI] [Google Scholar]
- Klich MA. Identification of common Aspergillus species. Utrecht, The Netherlands: Centraalbureau voor Schimmelcultures; 2002. [Google Scholar]
- Korpi A, Järnberg J, Pasanen A-L. Microbial volatile organic compounds. Critical Reviews in Toxicology. 2009;39(2):139–193. doi: 10.1080/10408440802291497. [DOI] [PubMed] [Google Scholar]
- Kulkarni P, Baron PA, Willeke K. Aerosol measurement: principles, techniques, and applications. New York: Wiley; 2011. [Google Scholar]
- Mesquita N, Portugal A, Videira S, Rodríguez-Echeverría S, Bandeira AML, Santos MJA, et al. Fungal diversity in ancient documents. A case study on the Archive of the University of Coimbra. International Biodeterioration and Biodegradation. 2009;63:626–629. doi: 10.1016/j.ibiod.2009.03.010. [DOI] [Google Scholar]
- Miller JD, Young JC. The use of ergosterol to measure exposure to fungal propagules in indoor air. American Industrial Hygiene Association Journal. 1997;58(1):39–43. doi: 10.1080/15428119791013062. [DOI] [PubMed] [Google Scholar]
- Niesler A, Górny RL, Wlazło A, Łudzeń-Izbińska B, Ławniczek-Wałczyk A, Gołofit-Szymczak M, et al. Microbial contamination of storerooms at the Auschwitz–Birkenau Museum. Aerobiologia. 2010;26:125–133. doi: 10.1007/s10453-009-9149-z. [DOI] [Google Scholar]
- Pasanen AL, Yli-Pietilä K, Pasanen P, Kalliokoski P, Tarhanen J. Ergosterol content in various fungal species and biocontaminated building materials. Applied and Environmental Microbiology. 1999;65(1):138–142. doi: 10.1128/aem.65.1.138-142.1999. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Pitt JI, Hocking AD. Fungi and food spoilage. London, New York: Springer, Dordrecht Heidelberg; 2009. [Google Scholar]
- Regulation of the Minister of Health dated. April 22, 2005 (Journal of Laws of 2005 No. 81, item 716, as amended and Journal of Laws 2008, No. 48, item 288). Polish.
- Report of a Working Group on Hazardous Fungi of the European Confederation of Medical Mycology (ECMM). Risk assessment of fungi reported from humans and animals (1996). Mycoses, 39(11–12), 407–417. [DOI] [PubMed]
- Robine E, Lacaze I, Moularat S, Ritoux S, Boissier M. Characteristic of exposure to airborne fungi: Measurement of ergosterol. Journal of Microbiological Methods. 2005;63(2):185–192. doi: 10.1016/j.mimet.2005.03.008. [DOI] [PubMed] [Google Scholar]
- Schäfer, I. (2014). New Standards in Preventive Conservation Management. IFLA WLIC 2014, 16–22 August 2014, Lyon, France. conference proceedings http://library.ifla.org/1005/7/209-schafer-en.pdf Accessed 20 November 2014.
- Skóra J, Zduniak K, Gutarowska B, Rembisz D. Harmful biological agents at museum workposts. Medycyna Pracy. 2012;63(2):153–165. [PubMed] [Google Scholar]
- Skowroń, J., & Górny, R. (2012). Harmful biological agents. In: D. Augustyńska, & M. Pośniak, (Eds.), The Interdepartmental Commission for Maximum Admissible Concentrations and Intensities for Agents Harmful to Health in the Working Environment: limit values 2012. Warszawa: Centralny Instytut Ochrony Pracy—Państwowy Instytut Badawczy. Polish.
- Stanisz, A. (2006). Approachable course of statistics based on software STATISTICA PL with examples from medicine. T.1: Basic Statistics (p. 362). StatSoft Polska, Kraków, Polish.
- Stępień Ł, Koczyk G, Waśkiewicz A. Genetic and phenotypic variation of Fusarium proliferatum isolates from different host species. Journal of Applied Genetics. 2011;52:487–496. doi: 10.1007/s13353-011-0059-8. [DOI] [PMC free article] [PubMed] [Google Scholar]
- White TJ, Bruns T, Lee S, Taylor J. Amplification and direct sequencing of fungal ribosomal RNA genes for phylogenetic. In: Innis MA, Gelfand DH, Shinsky JJ, White TJ, editors. The PCR Protocols: A Guide to Methods and Applications. San Diego, USA: Academic Press; 1990. pp. 315–322. [Google Scholar]
- Wiszniewska M, Walusiak-Skorupa J, Pannenko I, Draniak M, Pałczyński C. Occupational exposure and sensitization to fungi among museum workers. Occupational Medicine. 2009;59:237–242. doi: 10.1093/occmed/kqp043. [DOI] [PubMed] [Google Scholar]
- World Health Organization (WHO). (2005). Air quality guidelines for particulate matter, ozone, nitrogen dioxide and sulfur dioxide. Global update. Germany: Druckpartner Moser. [PubMed]
- Zhang Z, Schwartz S, Wagner L, Miller W. A greedy algorithm for aligning DNA sequences. Journal of Computational Biology. 2000;7(1–2):203–214. doi: 10.1089/10665270050081478. [DOI] [PubMed] [Google Scholar]
- Zielińska-Jankiewicz K, Kozajda A, Piotrowska M, Szadkowska-Stańczyk I. Microbiological contamination with moulds in work environment in libraries and archive storage facilities. Annals of Agricultural and Environmental Medicine. 2008;15:71–78. [PubMed] [Google Scholar]