Skip to main content
Journal of Applied Oral Science logoLink to Journal of Applied Oral Science
. 2015 Jul-Aug;23(4):358–368. doi: 10.1590/1678-775720140524

Correlation between clinical performance and degree of conversion of resin cements: a literature review

Grace DE SOUZA 1, Roberto Ruggiero BRAGA 2, Paulo Francisco CESAR 2, Guilherme Carpena LOPES 3
PMCID: PMC4560495  PMID: 26398507

Abstract

Resin-based cements have been frequently employed in clinical practice to lute indirect restorations. However, there are numerous factors that may compromise the clinical performance of those cements. The aim of this literature review is to present and discuss some of the clinical factors that may affect the performance of current resin-based luting systems. Resin cements may have three different curing mechanisms: chemical curing, photo curing or a combination of both. Chemically cured systems are recommended to be used under opaque or thick restorations, due to the reduced access of the light. Photo-cured cements are mainly indicated for translucent veneers, due to the possibility of light transmission through the restoration. Dual-cured are more versatile systems and, theoretically, can be used in either situation, since the presence of both curing mechanisms might guarantee a high degree of conversion (DC) under every condition. However, it has been demonstrated that clinical procedures and characteristics of the materials may have many different implications in the DC of currently available resin cements, affecting their mechanical properties, bond strength to the substrate and the esthetic results of the restoration. Factors such as curing mechanism, choice of adhesive system, indirect restorative material and light-curing device may affect the degree of conversion of the cement and, therefore, have an effect on the clinical performance of resin-based cements. Specific measures are to be taken to ensure a higher DC of the luting system to be used.

Keywords: Dental prosthesis retention, Dental materials, Luting agents, Biocompatible materials

INTRODUCTION

Resin cements are composite resins developed to deliver mechanical properties and handling characteristics that are important for luting indirect restorations. These cements contain different monomers, which are linked together during the polymerization reaction. Due to their application under an indirect restoration, in most cases the physical activation (photo activation) has very limited effect 14 . Therefore, there is a need for chemical activators. Activation of the polymerization means to induce the photo initiator (e.g., camphorquinone) or to break the molecule of the chemical initiator (benzoyl peroxide) so as to form free radicals that will initiate the polymerization. Free radicals link to monomers by breaking carbon-carbon double bonds. The continuous addition of monomers to a growing chain results in a polymeric chain. In general, the maximum degree of conversion (DC) – the percentage of aliphatic C=C (double) bonds converted into C-C (single) bonds to form the polymeric network – reached by resin cements is around 60%, 43 due to the increase of cement viscosity during the polymerization reaction, hindering the mobility of the reactive species 49 . The reaction slows down progressively up to a moment when new bonds cannot be made 71 .

Resin cements have been frequently employed for bonding indirect restorations to the teeth due to their mechanical behavior 34 – superior to conventional cements (resin-free) –, possibility of adhesion to the restorative material 50 and to the tooth structure with 7 or without an adhesive system 60 , and superior optical properties 36 when compared with conventional cements. However, limitations associated with the incomplete polymerization (low DC) of the cement may result in higher sorption and solubility values 67 , causing faster degradation of the cement finish line by the acids present in the oral biofilm 67 . Degradation of resin-based cements reduces the bond strength between them and the substrate 39 and causes dissolution of the finish line at the restoration margin, which may mean the clinical loss of the restoration either by debonding, fracture or secondary caries 20 . Unreacted monomers (not bonded to the polymeric chain) may also irritate the pulp and generate a local inflammatory response 18 .

There are multiple factors that may interfere with the DC of resin cements and, therefore, compromise the longevity of indirect restorations. Some of them are the material composition (monomers and other components of the activation system) 56 , possible inadvertent interactions between the bonding system and the cement 63 , characteristics of the restoration to be cemented (optical properties and thickness of the restoration) 14 , 15 and characteristics of the photo activation step 32 . This article aims to perform a comprehensive review of the factors involved in the DC of the resin-based luting systems and the impact of DC on luting system properties.

CURING MECHANISM

As previously mentioned, photo-activated or light-activated resin cements are indicated for situations where the light of the curing unit may pass through the restoration, such as translucent veneers and shallow inlays 56 . These cements are provided in a single paste with a photoinitiator system composed of a photosensitive component (usually camphorquinone) and a tertiary amine. The presence of light with a wavelength of 480 nm (blue region of the visible spectrum) activates camphorquinone 69 , which binds to the tertiary amine and then releases two free radicals that will start the monomers conversion. Photo-cured resin cements have unlimited working time, with the polymerization starting right after the exposure of the material to light 4 .

Chemically cured (self-cured) cements are indicated under thick restorations, for luting intrarradicular posts and crowns made of materials that block the light, such as metallic copings or highly opaque ceramics 42 , 68 , aiming to guarantee maximum properties over time in areas that light energy is unable to reach 71 . The limitations of these systems are the reduced working time as opposed to the extended setting time 77 and the tendency to become “yellowish”, due to the higher concentration of tertiary amines (activators) 29 . The polymerization reaction in self-cured cements requires the components of the activation system – tertiary amine and benzoyl peroxide – to get in contact by the mixing of two pastes, base and catalyst.

Dual-cure resin cements were developed in an attempt to combine the benefits of both photo and chemically activated systems 16 , 56 , 77 , obtaining optimized DC in the deepest locations under a restoration, controlled working time and short setting time. In such systems, there is a catalyst paste with a chemical initiator, usually benzoyl peroxide, and a base paste containing the photo-cured resin cement and the tertiary amine responsible for the activation of the self-cure reaction 57 . When both pastes are mixed together and exposed to light, the polymerization happens by physical (photo) and chemical (redox) activation. The appropriate working time is controlled by inhibitors of the self-cure reaction or by the amount of activators of the polymerization 56 . It is expected that in areas where there is not enough light, the interaction between the tertiary amine and benzoyl peroxide will be enough to ensure the cement polymerization 4 , 57 . However, when not properly photo-activated, dual-cure resin cements may present reduced DC 47 , 49 , 77 , which implicates in lower hardness 57 , higher solubility 71 , lower flexural 11 , 57 and compressive strengths, and lower bond strength to dentin in comparison to directly light-cured dual cements 7 , 77 . For instance, a self-adhesive dual cement applied in self-curing mode may show DC as low as 11% after a 10-minute setting time 77 . Considering the clinical application of the resin-based luting systems, which are used for the cementation of indirect restorations onto tooth structure, 10 min is an undesirably long time for a luting agent to obtain a great percentage of the optimal setting characteristics, without compromising the integrity of the margins and the cement layer under functional loading 8 , 77 .

In general, light-cured and dual-cured cements activated by light through a restoration thinner than 2.0 mm 4 , 36 , 44 , 75 have higher DC than self-cured cements 77 . When a dual cement is self-cured (no activation by light), mechanical properties such as flexural strength, modulus and hardness are reduced by 68.9%, 59.2% and 91.1%, respectively, in comparison to original values presented by dual-cured samples 34 . There are different factors that may affect the DC of self-cured luting systems, such as the relatively high concentration of polymerization inhibitors used to extend the material’s shelf life and to provide a clinically viable working time, ranging from 2 to 5 minutes, which adversely inhibits polymerization during the luting procedure 61 ; the slow rate of polymerization activation and subsequent propagation of radicals in comparison to a directly light-activated material 6 , 49 , 51 , 61 ; and the low concentration of benzoyl peroxide incorporated into those materials 6 , 49 . Furthermore, the hand-mixing of the two pastes incorporates air bubbles that further inhibit polymerization due to the presence of oxygen 79 and may act as stress concentrators that potentially result in cracking throughout the cement layer 56 . Although it has been demonstrated that the high incidence of air voids reduces the stress generated by the polymerization shrinkage of the cement due to a change in ratio of bonded to unbonded surfaces 5 , the clinical benefits of the inclusion of pores have not been determined. Pores are also incorporated in dual-cured cements during mixing and they may become an esthetic concern when cementing veneers 16 . To minimize the undesired consequences of the hand-mixing procedure, some manufacturers provide cements in a self-mixing apparatus (Figure 1), which eliminates the manual mixing step, generates a homogeneous mix and reduces the incorporation of bubbles. However, voids have been observed after automatic mixing as well 56 .

Figure 1. Summary of some resin-based luting systems currently available and their characteristics based on the papers included in this review. Composition may vary significantly among different materials.

Figure 1

Interestingly, if light incidence on the cement layer is significantly compromised, the chemical activator of dual cements improves DC when compared to photo-activated-only systems 1 , 7 , 15 , 16 but the efficacy of the self-curing mode is still controversial 8 , 14 , 49 and varies from one material to another 44 . It has been demonstrated that the absence of the self-curing component in light-activated systems negatively affects the DC of these cements when the light-curing component is not able to guarantee an acceptable degree of conversion, for example when applied underneath onlays of greater thickness 1 . Considering a clinical application in which almost no light reaches the cement layer, it is desirable to use dual resin cements that present a chemical curing mechanism as efficient as photo-curing 8 . However, there is currently no resin luting system in the market capable of overcoming this limitation 2 , 7 , 45 . In general, the chemical activation of dual cements does not seem enough to compensate for the absence of light under thick or opaque restorations, even 24 hours after the beginning of the activation 1 , 15 , 32 , 61 , 64 , 65 , 75 . The DC of a self-adhesive dual cement may vary from 37% when light-cured for 20 seconds 77 to 58% when light-cured for 40 seconds 43 , evidencing that there is also a direct correlation between light intensity received by a photo-activated material and its DC 14 , 46 , 49 . Laboratorial studies bring evidence that the activation time generally recommended by the manufacturer (Figure 1) is not sufficient to result in maximum degree of conversion 27 , 77 . Therefore, when highly opaque or thicker restorations need to be employed, a prolonged light exposure time is recommended (please read “Indirect Restorative Material” below), since a gradual increase in light-curing time and, therefore, in light transmission, gradually increases the Knoop hardness of resin-based luting systems 64 . Additionally, the use of a dual-cure system should always be considered to possibly increase the DC by means of a chemical activation of the monomeric system.

With regard to post-activation time, the 24-hour DC of light-cured and dual-cured cements is directly related to the DC obtained right after light exposure 4 , 75 . Even though DC is maximized during the first 30 minutes after light activation 2 , 79 , some cements present gradual increase in DC for up to 24 hours, mainly when used in the dual-curing mode 4 , 10 , 28 , 31 , 64 , 79 . However, it has been speculated that a delay in light activation of dual-cured materials would enhance their properties 56 by allowing the self-polymerization promoters to react at some extent before being entrapped by the polymeric chains as soon as the photo-activation begins 49 , 74 . Delaying the light activation for 2 min may, for instance, compensate for a lower dose of light reaching the cement layer 49 , but no effect is observed on the bond strength of resin cements to the substrate 28 . On the other hand, prolonged self-curing of the cement may also compromise the overall DC 49 and increase water sorption 71 when light activation is delayed for 10 min for the same reason, indicating that an ideal balance between self-curing and photo-activation is yet to be determined.

Under ideal circumstances, light-activated resin cements show higher DC than chemically cured resin cements, irrespective of brand names 49 , 57 . However, the DC of dual-cured cements is material-related, which means that it is more associated with the brand name than with the material classification per se and some systems are significantly more dependent on light activation than others 1 , 10 , 11 , 15 , 16 , 31 , 51 , 73 , 79 . Just as an illustration, the DC of a given dual-cured cement (RelyX ARC, 3M Espe, St. Paul, MN, USA) may vary from 81% to 61% when cured under light as opposed to total absence of light respectively, and from 56% to 26% when another dual-cured cement (RelyX Unicem, 3M Espe, St. Paul, MN, USA) is cured under the same conditions 43 . This difference may be explained by the difference in composition between both materials. For instance, some resin-based cements present twice as much benzoyl peroxide than others 51 . The lower DC may affect some critical properties of the resin-based cements 64 . Dual cements cured under a dual mode (photo+chemical) present lower toxicity and solubility than dual cements cured under the self-curing mechanism (chemical only) 55 , 65 . Dual curing also leads to a rapid increase in hardness whereas chemically cured specimens are still soft 30 minutes 22 or even one hour 64 after mixing. Dual-curing mode also results in improved bond strength 44 and mechanical properties such as flexural strength, modulus and hardness, in comparison to light curing or chemical curing only 34 , 64 .

Adhesive and self-adhesive resin cements have functional monomers such as 10-methacryloyloxydecyl dihidrogen phosphate (10-MDP), 4-methacryloxyethyl trimellitate anhydride (4-META) and phosphoric esters. These resin cements generally have a dual-cure mechanism. Self-adhesive cements have acidic functionalities in order to demineralize tooth structure 23 , and an acid-base reaction between the acid groups of the monomers and the glass filler of the core material or the mineralized tooth surface starts immediately after the mixing of the components and application of the cement on the tooth surface 31 . However, those acidic monomers have been shown to negatively affect the cement degree of conversion, since they interfere with the amine initiator 77 . This interference compromises both the self-cure and the dual-cure modes 76 . The very low polymerization shrinkage strain of some self-adhesive cements may also be an evidence of reduced DC 40 . Indeed, there is a significant variation between the DC of different materials 31 , 40 and increasing the light-exposure from 20 s to 40 s does not improve DC values after 6 hours 31 as much as a temperature increase of the cement improves 40 . However, when the absence (self-cure) and the presence (dual-cure) of photo-activation are compared, the presence of light may result in a 10-fold increase in the material degree of conversion 40 . Although another initiator system based on sodium aryl sulfate or aryl-borate salts has been proposed 70 to compensate for the interaction between acidic monomers and the amine initiator in self-adhesive systems, no evidence has been found of any significant improvement in the DC for sodium persulfate-containing materials 8 , 77 .

Another way to improve the polymerization kinetics of resin-based luting systems is to increase the temperature of the material 30 , 51 . High viscosity cements have significantly lower degree of conversion than low viscosity cements 24 , probably due to the reduced mobility of the monomers in viscous materials. Increased temperature prior to and during polymerization leads to higher DC, due to increased free radical and monomer mobility 1 , 21 and collision frequency of the unreacted active groups resulting from the decrease in the viscosity of the material 21 , 30 . However, pre-heating (50°C) dual-cured resin cements with a higher concentration of the chemical activator (benzoyl peroxide) may result in significant decrease in working time, thus compromising the clinical application of the material 30 , 51 , and still may not compensate for the absence of light 30 . The clinical applicability of the pre-heating technique is questionable, since the tooth structure could not be possibly heated up to 50°C, which would immediately result in the cement temperature decrease. Therefore, any evaluation on this topic should limit the pre-heating temperature to 37°C 51 .

BONDING AND CEMENTATION

The bonding between resin cement and the tooth structure (or the core build-up material) is generally made possible by the use of a self-adhesive resin cement or by the application of a bonding agent/system. The bonding agent/system may either be self-etch or total-etch (etch-and-rinse) 13 . However, there are restrictions for the application of some simplified adhesive systems, more precisely two-step total-etch (primer and adhesive in one bottle) and “all-in-one” self-etch systems and resin cements with some chemical activation, either self-cured or dual-cured 37 . It has been shown that the lower the pH of the bonding agent employed, the lower the bond strength between self-cured cement and dentin 63 . The use of a simplified adhesive bonded to a self-cured cement results in 10-50% of the bond strength presented when the same adhesive is bonded to a light-cured cement 63 .

The reason for those diminished bond strength values is that when simplified-step adhesives are used together with chemical-cured cements, there is an interaction between the residual acidic monomers from the adhesive inhibition layer and the binary peroxide-amine catalytic components that are commonly employed in chemically cured resin composites 63 . Therefore, the tertiary amine of the resin cement is neutralized and does not react with the initiator, resulting in low bond strength at the adhesive-cement interface 19 . Besides that, the adhesive layer of simplified systems (all-in-one) is highly permeable to dentinal fluids due to incomplete polymerization 12 , 13 , and these are then kept at the interface between the adhesive and the cement, compromising the bonding between those two substrates 19 , 72 , which is demonstrated by exclusively adhesive failure modes 63 . To maximize the performance of the resin cements, self-cured or dual-cure cements are to be employed only in association either with three-step total etch systems or with self-etching primer systems containing a separate bonding agent. For all of the other adhesive systems, the resin cement employed should be exclusively photo-activated.

INDIRECT RESTORATIVE MATERIAL

When photo-activation of a resin cement is performed, part of the visible light that reaches the crown is transmitted through the restoration, part is absorbed and part of it is reflected on the surface 57 . Consequently, the light intensity that effectively reaches the cement varies according to the optical characteristics of the restorative material 15 , 62 , such as opacity 14 , 44 and shade 8 , 53 , and the final thickness of the restoration 15 , 25 , 48 . The higher the thickness and the lower the value (darkness) of the restoration, the lower the light intensity reaching the cement layer, which may compromise the DC of a given cement 15 , 47 , 57 , 79 .

There are many restorative systems nowadays that may be used for the manufacturing of all-ceramic crowns (Figure 2). Each one of these ceramic systems has a microstructure that directly interferes with the amount of light that may be transmitted through the restoration 14 , 78 . Considering restorations with similar shade and thickness, ceramics with a higher number of light scattering centers (interface between different microstructural phases) are more opaque and prone to block visible light 14 , 33 , 57 , 58 , compromising the intensity of the physical polymerization of the resin cement 57 . Pores, frequently found in feldspathic porcelains and glass-infiltrated composites due to the processing method of these materials, act as light scattering centers as well. Light scattering occurs at interfaces of different phases with dissimilar refraction indexes. A free of pores porcelain would be a material with no light scattering interface and would thus show transmittance, resulting in high DC for dual cements even under a 3 mm-thick layer 15 . A multi-phase material would scatter the light because the incident light beam will change direction from one phase to another and the result will be a weaker incident light. A multi-phase structure within a material also results in light scattering and low transmittance 14 . Thereafter, glass-infiltrated alumina-zirconia (In-Ceram Zirconia System, Vita Zahnfabrik, Bad Säckingen, Baden-Württemberg, Germany) is the most opaque alternative among current clinical options, due to the presence of four distinct phases with different refraction indexes (alumina, Ceria-stabilized zirconia, lantanium glass and pores), with a final maximum transmittance of only 6% in 0.5 mm-thick copings, and when the thickness of the same material increases to 1.5 mm the transmittance becomes as low as 1% of the initial light intensity. Glass-infiltrated spinel ceramic (In-Ceram Spinell, Vita Zahnfabrik, Bad Säckingen, Baden-Württemberg, Germany) presents significantly higher transmittance because it has only two phases (glass and spinel), with similar refraction indexes.

Figure 2. Correlation between indirect restorative materials and the curing properties of the resin cement underneath.

Figure 2

When comparing the translucency of lithium-disilicate glass-ceramic and leucite-reinforced glass ceramic, Illie, et al. 36 (2008) observed that the first is more opaque than the latter (Figure 2). Lithium-disilicate glass ceramic contains a main crystalline phase of “elongated crystals building a scaffold of many small interlocking needle-like crystals randomly oriented” 36 , with a second crystalline phase consisting of lithium orthophosphate 35 . On the other hand, leucite-reinforced glass-ceramic is a less dense material, characterized by the single crystal formation of leucite crystals 35 , 36 , indicating that lithium-disilicate ceramics scatter more light than leucite ceramics. Light delivered to the cement layer through lithium-disilicate ceramic (shade medium opacity 1) is reduced to 45% under 1 mm ceramic slabs, 16% under 2 mm slabs and approximately 8% under 3 mm slabs 80 . Leucite-reinforced glass ceramic slabs reduce the light transmittance to 80%, 64% and 43% under 0.7, 1.4 and 2.0 mm thick samples, respectively 47 .

As previously mentioned, the relationship between restoration thickness and transmittance is highly dependent on the opacity of the material 14 , 51 , 54 , 80 . However, the impact of the amount of light reaching the cement layer on its DC is controversial. Dual-cure resin cements activated by light under a 1.5 mm lithium-disilicate glass ceramic (Shade A2 low translucency) surface presented a DC similar to that of cements cured under direct light exposure 51 , whilst samples cured through 1.4 mm-thick leucite-reinforced glass-ceramic slabs may 54 or may not 48 show significantly lower hardness values than groups activated with direct light exposure, depending on the luting system employed. In another study, samples light-cured under 1 or 2 mm thick lithium-disilicate slabs only showed decreased hardness when light exposure time was 20 s or less, indicating that longer exposure times may compensate for light attenuation of the indirect restorative material 80 . A randomized clinical split-mouth study evaluating the longevity of glass-infiltrated alumina crowns cemented with three different cements (two resin-based and one glass-ionomer) evidenced acceptable survival rates for all groups, with dual-cured cements showing higher survival rate than glass-ionomer cement, indicating that the opacity of the crown did not affect the performance of the cement/restoration 66 . It is important to remember that the final absolute transmittance values of a restoration would be even more compromised considering the thickness and the optical characteristics of the porcelain veneer layer 14 . The DC of a dual-cured cement activated under glass-infiltrated alumina (1.2 mm thickness) with porcelain veneer layer (0.8 mm thickness) is significantly reduced when compared to feldspathic porcelain samples (2 mm thick) and to the control group, activated under direct light exposure 14 .

When the impact of the shade of the ceramic system is evaluated, it can be observed that if shades with higher chroma are used, less energy reaches the cement layer, since dark pigments absorb a significant amount of light 9 , negatively influencing the cure of light-dependant cements. Dual-cured cements light-activated under 2 mm-thick samples of darker dentin shade of feldspathic porcelain present significantly lower DC than cements light-activated under lighter shades 53 . When yellow and translucent shades of a resin cement were light-activated under the darker porcelain, only prolonged light-exposure time (40 seconds) was capable of increasing the DC of the cement yellow shade 53 , indicating that the combination of darker shades in both the cement and the indirect restorative material compromise the overall DC of the cement layer.

With regard to laminate veneers, some studies show that although the bond strength between veneers and tooth structure is not affected by shade or opacity of the ceramic system, the DC of the cement may be diminished by either thicker, darker or more opaque restorations 15 , frequently used to mask severely darkened teeth, and a lower DC of the cement layer may compromise the esthetic result due to the continuous discoloration of the material 75 . The analysis of the DC of a light-cured resin cement after the superimposition of different veneer materials with different thicknesses indicated that the effect of light attenuation on the degree of conversion is not significant only for ceramic thicknesses of 1.0 mm or less 62 .

Considering the optical properties of the indirect restorative composites, there are different factors playing a role in light transmittance, such as particle size distribution, thickness of the restoration and shade. The smaller the particles, the more interfaces will be present acting as light scattering centers 33 , consequently increasing the opacity of the material employed, which indicates that larger particles allow for deeper activation of the cement layer by light 4 , 57 , 58 . Interestingly, the hardness of dual resin-based cements is less affected when photo-activation is performed through an indirect restorative composite – either microfilled or micro-hybrid – than when it is performed through an all-ceramic system – lithium disilicate and glass ceramic 57 . When the effect of thickness is evaluated, there is indeed an inverse correlation between thickness of an indirect composite resin restoration and Knoop hardness of the resin based luting system 26 . Dual resin cements cured under 2 mm-thick micro-hybrid composite samples show significantly lower DC than samples cured under ideal conditions 30 , and the DC of dual cements is 12% lower under 4 mm onlays in comparison to that measured under 2 mm thick onlays 1 . With regard to the effect of shade on indirect composite resin light transmittance, Arrais, et al. 8 (2008) demonstrated that only 11% of light reaches the cement layer when cured through a 2 mm microhybrid composite A2 shade as opposed to 8% when A4 shade was employed, but no effect on DC was observed for dual-cured resin cements with higher concentration of benzoyl peroxide. The authors pointed out that the adhesive component also presented a chemical activator of the polymerization and could, therefore, compensate for the absence of light 8 .

LIGHT CURING DEVICE

It has been demonstrated that the hardness of dual-cured cements is dependent on the level of exposure to the curing light 32 . As previously mentioned, the component responsible for the chemical activation of the material cannot compensate for the total absence of light 3 , 32 . The higher the light intensity and the longer the exposure time of the resin cement, the higher the Knoop hardness of the dual-cured materials 64 . However, even when under direct light exposure, there is a limit above which the DC of a photo or dual-cure cement cannot be increased 44 .

Quartz-tungsten-halogen (QTH) light curing units (LCU) deliver light irradiance varying between 400 and 1360 mW/cm2 17 , 50 , 64 . When exposure time (40 s, 60 s or 120 s) and intensity (1200, 800 or 400 mW/cm2) of light exposure on DC of dual cements was evaluated, different materials showed different results 1 , although all the associations resulted in the same amount of energy (48 J). Activation of dual cements under 2 mm resin composite onlays using low light intensity for prolonged time presented a trend towards higher DC, probably due to the slow increase in the material viscosity, allowing more monomers mobility 1 .

Light-emitting diodes (LED)-based units were introduced in the market in 2001 76 and are another option to activate photo-cured resin cements. These units generate light under a narrower spectrum (between 450 and 490 nm) with the peak around 468 nm, the ideal wavelength for resin-based materials using camphorquinone as the photoinitiator 17 . When the photo-activation of a cement is performed through a ceramic system, light transmittance increases for higher wavelengths 57 . The higher mean wavelength of LED lights improves the capacity of the equipment to activate resin cements under indirect restorations 36 , 76 . However, light-intensity is also critical, since LED with relatively low light intensity (320 mW/cm2) results in decreased Knoop hardness at the bottom of dual-cured cement samples 53 .

The effect of QTH (905 mW/cm2) and LED (1585 mW/cm2) curing units on Knoop hardness of resin-based cements indicated that there was no effect of LCU on the hardness of dual-cure cements 54 . Samples cured under 1.4 and 2.0 mm ceramic slabs (leucite glass ceramic, shade A3) showed lower hardness values than samples cured under direct light exposure and under 0.7 mm slabs 54 . Authors observed that hardness on dual-cured luting agents may not be dependent on the light source, as long as the irradiance level for the effective wavelength region to activate the photo-initiator is similar 54 .

With the application of high-power curing units in dentistry, LED-based equipment with high light intensity (1000-1600 mW/cm2) are being advertised as an alternative to reduce the curing time of resin-based materials. However, the minimum time required to properly cure a dual-cured luting system is 15 s under ideal conditions, so that maximized mechanical properties can be obtained 36 . Therefore, it is not recommended to reduce the light exposure time to less than 15 seconds on each side of a restoration, irrespective of light intensity 36 . Indeed, it has been demonstrated that light-curing a dual-cure cement for 9 s with a LED device (1100 mW/cm2) results in significantly reduced degree of conversion 41 . The authors observed that exposing dual-cure material to high intensity light may increase its viscosity more rapidly, hindering the migration of active radical components responsible for further polymerization 41 . Similar results were obtained when LED device (1100 mW/cm2) with different activation modes and QTH (600 mW/cm2) were used to photoactivate resin cements between ceramic samples (lithium disilicate) and human dentin, and the authors found out that groups photo-activated for 10 s presented inferior bond strength 50 . Higher bond strength results were obtained when LED devices under exponential mode and QTH were used, and since the exponential mode was applied for twice as much time as the other LED groups, the overall energy delivered was increased, which may have enhanced the DC 50 . Authors also observed that higher light intensity produces higher contraction strains during resin polymerization, which may promote debonding at the adhesive interface 50 . Therefore, prolonged exposure times are desirable not only to increase the energy delivered to the luting material, in an attempt to compensate for the attenuation of the light promoted by the indirect restorative material, but also to reduce stress generation at the cement-substrate interface, to ensure preservation of the bonding.

A comparison of different light curing equipment (QTH – 600 mW/cm2; LED – 1400 mW/cm2; argon ion laser – 600 mW/cm2) used to activate resin cements under 2 mm-thick samples of composite resin indicated that the degree of conversion of the resin cements is again more related to the commercial brand and, consequently, to the material composition than to the curing device itself, with LED and argon ion laser devices resulting in lower DC for one of the materials in the photo-cured mode 69 . Although the short range of the spectra peak for LED devices may be advantageous when curing under ceramic systems, a wider range may be clinically interesting to photo-activate alternative photoinitiators, promoting a higher DC for QTH lights even in the presence of lower light intensity.

In addition to the factors presented above, there are other variables playing a role in the DC of light-activated resin-based cements, such as the distance between the tip of the curing device and the cement layer 4 , 52 , 75 and other indirect factors reducing the light intensity being delivered 38 , 50 , 52 , 59 . Based on the results presented and the number of studies indicating that prolonged light-activation may be beneficial for the DC of dual- or photo-cured cements 43 , 53 , 80 , increasing the light exposure time, even though this would mean a couple more minutes of clinical procedure, would be certainly beneficial for the clinical performance of an indirect restoration.

CONCLUSION

The clinical success of an indirect restoration is not only attributed to the DC of the resin cement or to its mechanical properties, since there are other aspects that determine the clinical performance of dental prostheses. Nonetheless, ensuring a high DC is paramount to obtain the best out of the chemical and physical properties of the resin cement, besides being a critical factor for biocompatibility. When performing a luting procedure, one should pay attention to the characteristics of the indirect restorative material to be employed, and make a conscious decision of using a cement system that would be more indicated to the clinical case necessities. Curing modes and the best light-curing technique are examples of information that is to be available. It is crucial for clinicians to know and understand the cement systems they are working with.

REFERENCES

  • 1.Acquaviva PA, Cerutti F, Adami G, Gagliani M, Ferrari M, Gherlone E, et al. Degree of conversion of three composite materials employed in the adhesive cementation of indirect restorations: a micro-Raman analysis. J Dent. 2009;37:610–615. doi: 10.1016/j.jdent.2009.04.001. [DOI] [PubMed] [Google Scholar]
  • 2.Aguiar TR, Di Francescantonio M, Arrais CA, Ambrosano GM, Davanzo C, Giannini M. Influence of curing mode and time on degree of conversion of one conventional and two self-adhesive resin cements. Oper Dent. 2010;35:295–299. doi: 10.2341/09-252-L. [DOI] [PubMed] [Google Scholar]
  • 3.Aguiar TR, Oliveira M, Arrais CAG, Ambrosano GMB, Rueggeberg F, Giannini M. The effect of photopolymerization on the degree of conversion, polymerization kinetic, biaxial flexure strength, and modulus of self-adhesive resin cements. J Prosthet Dent. 2015;113:128–134. doi: 10.1016/j.prosdent.2014.09.011. [DOI] [PubMed] [Google Scholar]
  • 4.Akgungor G, Akkayan B, Gaucher H. Influence of ceramic thickness and polymerization mode of a resin luting agent on early bond strength and durability with a lithium disilicate-based ceramic system. J Prosthet Dent. 2005;94:234–241. doi: 10.1016/j.prosdent.2005.04.020. [DOI] [PubMed] [Google Scholar]
  • 5.Alster D, Feilzer AJ, Gee AJ, Mol A, Davidson CL. The dependence of shrinkage stress reduction on porosity concentration in thin resin layers. J Dent Res. 1992;71:1619–1622. doi: 10.1177/00220345920710091401. [DOI] [PubMed] [Google Scholar]
  • 6.Andrzejewska E. Photopolymerization kinetics of multifunctional monomers. Prog Polym Sci. 2001;26:605–665. [Google Scholar]
  • 7.Arrais CA, Giannini M, Rueggeberg FA, Pashley DH. Microtensile bond strength of dual-polymerizing cementing systems to dentin using different polymerizing modes. J Prosthet Dent. 2007;97:99–106. doi: 10.1016/j.prosdent.2006.12.007. [DOI] [PubMed] [Google Scholar]
  • 8.Arrais CA, Rueggeberg FA, Waller JL, Goes MF, Giannini M. Effect of curing mode on the polymerization characteristics of dual-cured resin cement systems. J Dent. 2008;36:418–426. doi: 10.1016/j.jdent.2008.02.014. [DOI] [PubMed] [Google Scholar]
  • 9.Barghi N, McAlister EH. LED and halogen lights: effect of ceramic thickness and shade on curing luting resin. Compend Contin Educ Dent. 2003;24:497–500,502,504. [PubMed] [Google Scholar]
  • 10.Braga RR, Ballester RY, Daronch M. Influence of time and adhesive system on the extrusion shear strength between feldspathic porcelain and bovine dentin. Dent Mater. 2000;16:303–310. doi: 10.1016/s0109-5641(00)00023-3. [DOI] [PubMed] [Google Scholar]
  • 11.Braga RR, Cesar PF, Gonzaga CC. Mechanical properties of resin cements with different activation modes. J Oral Rehabil. 2002;29:257–262. doi: 10.1046/j.1365-2842.2002.00821.x. [DOI] [PubMed] [Google Scholar]
  • 12.Breschi L, Cadenaro M, Antoniolli F, Sauro S, Biasotto M, Prati C, et al. Polymerization kinetics of dental adhesives cured with LED: correlation between extent of conversion and permeability. Dent Mater. 2007;23:1066–1072. doi: 10.1016/j.dental.2006.06.040. [DOI] [PubMed] [Google Scholar]
  • 13.Cadenaro M, Antoniolli F, Sauro S, Tay FR, Di Lenarda R, Prati C, et al. Degree of conversion and permeability of dental adhesives. Eur J Oral Sci. 2005;113:525–530. doi: 10.1111/j.1600-0722.2005.00251.x. [DOI] [PubMed] [Google Scholar]
  • 14.Calgaro PA, Furuse AY, Correr GM, Ornaghi BP, Gonzaga CC. Influence of the interposition of ceramic spacers on the degree of conversion and the hardness of resin cements. Braz Oral Res. 2013;27:403–409. doi: 10.1590/S1806-83242013000500004. [DOI] [PubMed] [Google Scholar]
  • 15.Cardash HS, Baharav H, Pilo R, Ben-Amar A. The effect of porcelain color on the hardness of luting composite resin cement. J Prosthet Dent. 1993;69:620–623. doi: 10.1016/0022-3913(93)90293-w. [DOI] [PubMed] [Google Scholar]
  • 16.Caughman WF, Chan DC, Rueggeberg FA. Curing potential of dual-polymerizable resin cements in simulated clinical situations. J Prosthet Dent. 2001;86:101–106. doi: 10.1067/mpr.2001.114842a. [DOI] [PubMed] [Google Scholar]
  • 17.Cekic I, Ergun G, Lassila LV, Vallittu PK. Ceramic-dentin bonding: effect of adhesive systems and light-curing units. J Adhes Dent. 2007;9:17–23. [PubMed] [Google Scholar]
  • 18.Chang HH, Chang MC, Wang HH, Huang GF, Lee YL, Wang YL, et al. Urethane dimethacrylate induces cytotoxicity and regulates cyclooxygenase-2, hemeoxygenase and carboxylesterase expression in human dental pulp cells. Acta Biomater. 2014;10:722–731. doi: 10.1016/j.actbio.2013.10.006. [DOI] [PubMed] [Google Scholar]
  • 19.Cheong C, King NM, Pashley DH, Ferrari M, Toledano M, Tay FR. Incompatibility of self-etch adhesives with chemical/dual-cured composites: two-step vs one-step systems. Oper Dent. 2003;28:747–755. [PubMed] [Google Scholar]
  • 20.D'Arcangelo C, Zarow M, Angelis F, Vadini M, Paolantonio M, Giannoni M, et al. Five-year retrospective clinical study of indirect composite restorations luted with a light-cured composite in posterior teeth. Clin Oral Investig. 2014;18:615–624. doi: 10.1007/s00784-013-1001-8. [DOI] [PubMed] [Google Scholar]
  • 21.Daronch M, Rueggeberg FA, Goes MF, Giudici R. Polymerization kinetics of pre-heated composite. J Dent Res. 2006;85:38–43. doi: 10.1177/154405910608500106. [DOI] [PubMed] [Google Scholar]
  • 22.Darr AH, Jacobsen PH. Conversion of dual cure luting cements. J Oral Rehabil. 1995;22:43–47. doi: 10.1111/j.1365-2842.1995.tb00209.x. [DOI] [PubMed] [Google Scholar]
  • 23.Munck J, Vargas M, Van Landuyt K, Hikita K, Lambrechts P, Van Meerbeek B. Bonding of an auto-adhesive luting material to enamel and dentin. Dent Mater. 2004;20:963–971. doi: 10.1016/j.dental.2004.03.002. [DOI] [PubMed] [Google Scholar]
  • 24.Di Francescantonio M, Aguiar TR, Arrais CA, Cavalcanti AN, Davanzo CU, Giannini M. Influence of viscosity and curing mode on degree of conversion of dual-cured resin cements. Eur J Dent. 2013;7:81–85. [PMC free article] [PubMed] [Google Scholar]
  • 25.El-Badrawy WA, El-Mowafy OM. Chemical versus dual curing of resin inlay cements. J Prosthet Dent. 1995;73:515–524. doi: 10.1016/s0022-3913(05)80109-x. [DOI] [PubMed] [Google Scholar]
  • 26.El-Mowafy OM, Rubo MH. Influence of composite inlay/onlay thickness on hardening of dual-cured resin cements. 147J Can Dent Assoc. 2000;66 [PubMed] [Google Scholar]
  • 27.Fan PL, Schumacher RM, Azzolin K, Geary R, Eichmiller FC. Curing-light intensity and depth of cure of resin-based composites tested according to international standards. J Am Dent Assoc. 2002;133:429–434. doi: 10.14219/jada.archive.2002.0200. [DOI] [PubMed] [Google Scholar]
  • 28.Faria-e-Silva AL, Fabião MM, Arias VG, Martins LR. Activation mode effects on the shear bond strength of dual-cured resin cements. Oper Dent. 2010;35:515–521. doi: 10.2341/10-051-L. [DOI] [PubMed] [Google Scholar]
  • 29.Ferracane JL, Moser JB, Greener EH. Ultraviolet light-induced yellowing of dental restorative resins. J Prosthet Dent. 1985;54:483–487. doi: 10.1016/0022-3913(85)90418-4. [DOI] [PubMed] [Google Scholar]
  • 30.França FA, Oliveira M, Rodrigues JA, Arrais CA. Pre-heated dual-cured resin cements: analysis of the degree of conversion and ultimate tensile strength. Braz Oral Res. 2011;25:174–179. doi: 10.1590/s1806-83242011000200013. [DOI] [PubMed] [Google Scholar]
  • 31.Frassetto A, Navarra CO, Marchesi G, Turco G, Di Lenarda R, Breschi L, et al. Kinetics of polymerization and contraction stress development in self-adhesive resin cements. Dent Mater. 2012;28:1032–1039. doi: 10.1016/j.dental.2012.06.003. [DOI] [PubMed] [Google Scholar]
  • 32.Hasegawa EA, Boyer DB, Chan DC. Hardening of dual-cured cements under composite resin inlays. J Prosthet Dent. 1991;66:187–192. doi: 10.1016/s0022-3913(05)80046-0. [DOI] [PubMed] [Google Scholar]
  • 33.Heffernan MJ, Aquilino SA, Diaz-Arnold AM, Haselton DR, Stanford CM, Vargas MA. Relative translucency of six all-ceramic systems. Part II: core and veneer materials. J Prosthet Dent. 2002;88:10–15. [PubMed] [Google Scholar]
  • 34.Hofmann N, Papsthart G, Hugo B, Klaiber B. Comparison of photo-activation versus chemical or dual-curing of resin-based luting cements regarding flexural strength, modulus and surface hardness. J Oral Rehabil. 2001;28:1022–1028. doi: 10.1046/j.1365-2842.2001.00809.x. [DOI] [PubMed] [Google Scholar]
  • 35.Höland W, Schweiger M, Frank M, Rheinberger V. A comparison of the microstructure and properties of the IPS Empress 2 and the IPS Empress glass-ceramics. J Biomed Mater Res. 2000;53:297–303. doi: 10.1002/1097-4636(2000)53:4<297::aid-jbm3>3.0.co;2-g. [DOI] [PubMed] [Google Scholar]
  • 36.Ilie N, Hickel R. Correlation between ceramics translucency and polymerization efficiency through ceramics. Dent Mater. 2008;24:908–914. doi: 10.1016/j.dental.2007.11.006. [DOI] [PubMed] [Google Scholar]
  • 37.Inoue S, Vargas MA, Abe Y, Yoshida Y, Lambrechts P, Vanherle G, et al. Microtensile bond strength of eleven contemporary adhesives to dentin. J Adhes Dent. 2001;3:237–245. [PubMed] [Google Scholar]
  • 38.Jung H, Friedl KH, Hiller KA, Haller A, Schmalz G. Curing efficiency of different polymerization methods through ceramic restorations. Clin Oral Investig. 2001;5:156–161. doi: 10.1007/s007840100118. [DOI] [PubMed] [Google Scholar]
  • 39.Kitasako Y, Burrow MF, Katahira N, Nikaido T, Tagami J. Shear bond strengths of three resin cements to dentine over 3 years in vitro. J Dent. 2001;29:139–144. doi: 10.1016/s0300-5712(00)00058-0. [DOI] [PubMed] [Google Scholar]
  • 40.Kitzmüller K, Graf A, Watts D, Schedle A. Setting kinetics and shrinkage of self-adhesive resin cements depend on cure-mode and temperature. Dent Mater. 2011;27:544–551. doi: 10.1016/j.dental.2011.02.004. [DOI] [PubMed] [Google Scholar]
  • 41.Komori PC, Paula AB, Martin AA, Tango RN, Sinhoreti MA, Correr L., Sobrinho Effect of light energy density on conversion degree and hardness of dual-cured resin cement. Oper Dent. 2010;35:120–124. doi: 10.2341/09-126-L. [DOI] [PubMed] [Google Scholar]
  • 42.Krämer N, Lohbauer U, Frankenberger R. Adhesive luting of indirect restorations. Am J Dent. 2000;13:60D–76D. [PubMed] [Google Scholar]
  • 43.Kumbuloglu O, Lassila LV, User A, Vallittu PK. A study of the physical and chemical properties of four resin composite luting cements. Int J Prosthodont. 2004;17:357–363. [PubMed] [Google Scholar]
  • 44.Linden JJ, Swift EJ Jr, Boyer DB, Davis BK. Photo-activation of resin cements through porcelain veneers. J Dent Res. 1991;70:154–157. doi: 10.1177/00220345910700021201. [DOI] [PubMed] [Google Scholar]
  • 45.Lührs AK, Munck J, Geurtsen W, Van Meerbeek B. Composite cements benefit from light-curing. Dent Mater. 2014;30:292–301. doi: 10.1016/j.dental.2013.11.012. [DOI] [PubMed] [Google Scholar]
  • 46.Lührs AK, Pongprueksa P, Munck J, Geurtsen W, Van Meerbeek B. Curing mode affects bond strength of adhesively luted composite CAD/CAM restorations to dentin. Dent Mater. 2014;30:281–291. doi: 10.1016/j.dental.2013.11.016. [DOI] [PubMed] [Google Scholar]
  • 47.Meng X, Yoshida K, Atsuta M. Influence of ceramic thickness on mechanical properties and polymer structure of dual-cured resin luting agents. Dent Mater. 2008;24:594–599. doi: 10.1016/j.dental.2007.06.014. [DOI] [PubMed] [Google Scholar]
  • 48.Moraes RR, Brandt WC, Naves LZ, Correr L, Sobrinho, Piva E. Light- and time-dependent polymerization of dual-cured resin luting agent beneath ceramic. Acta Odontol Scand. 2008;66:257–261. doi: 10.1080/00016350802241563. [DOI] [PubMed] [Google Scholar]
  • 49.Moraes RR, Faria-e-Silva AL, Ogliari FA, Correr L, Sobrinho, Demarco FF, Piva E. Impact of immediate and delayed light activation on self-polymerization of dual-cured dental resin luting agents. Acta Biomater. 2009;5:2095–2100. doi: 10.1016/j.actbio.2009.01.030. [DOI] [PubMed] [Google Scholar]
  • 50.Nalcaci A, Kucukesmen C, Uludag B. Effect of high-powered LED polymerization on the shear bond strength of a light-polymerized resin luting agent to ceramic and dentin. J Prosthet Dent. 2005;94:140–145. doi: 10.1016/j.prosdent.2005.05.001. [DOI] [PubMed] [Google Scholar]
  • 51.Oliveira M, Cesar PF, Giannini M, Rueggeberg FA, Rodrigues J, Arrais CA. Effect of temperature on the degree of conversion and working time of dual-cured resin cements exposed to different curing conditions. Oper Dent. 2012;37:370–379. doi: 10.2341/11-198-L. [DOI] [PubMed] [Google Scholar]
  • 52.Ozyesil AG, Usumez A, Gunduz B. The efficiency of different light sources to polymerize composite beneath a simulated ceramic restoration. J Prosthet Dent. 2004;91:151–157. doi: 10.1016/j.prosdent.2003.11.006. [DOI] [PubMed] [Google Scholar]
  • 53.Passos SP, Kimpara ET, Bottino MA, Santos GC Jr, Rizkalla AS. Effect of ceramic shade on the degree of conversion of a dual-cure resin cement analyzed by FTIR. Dent Mater. 2013;29:317–323. doi: 10.1016/j.dental.2012.11.014. [DOI] [PubMed] [Google Scholar]
  • 54.Pazin MC, Moraes RR, Goncalves LS, Borges GA, Sinhoreti MA, Correr L., Sobrinho Effects of ceramic thickness and curing unit on light transmission through leucite-reinforced material and polymerization of dual-cured luting agent. J Oral Sci. 2008;50:131–136. doi: 10.2334/josnusd.50.131. [DOI] [PubMed] [Google Scholar]
  • 55.Pearson GJ, Longman CM. Water sorption and solubility of resin-based materials following inadequate polymerization by a visible-light curing system. J Oral Rehabil. 1989;16:57–61. doi: 10.1111/j.1365-2842.1989.tb01317.x. [DOI] [PubMed] [Google Scholar]
  • 56.Pegoraro TA, Silva NR, Carvalho RM. Cements for use in esthetic dentistry. Dent Clin North Am. 2007;51:453–471. doi: 10.1016/j.cden.2007.02.003. [DOI] [PubMed] [Google Scholar]
  • 57.Pick B, Gonzaga CC, Junior WS, Kawano Y, Braga RR, Cardoso PE. Influence of curing light attenuation caused by aesthetic indirect restorative materials on resin cement polymerization. Eur J Dent. 2010;4:314–323. [PMC free article] [PubMed] [Google Scholar]
  • 58.Pilo R, Cardash HS. Post-irradiation polymerization of different anterior and posterior visible light-activated resin composites. Dent Mater. 1992;8(5):299–304. doi: 10.1016/0109-5641(92)90104-k. [DOI] [PubMed] [Google Scholar]
  • 59.Rasetto FH, Driscoll CF, Prestipino V, Masri R, von Fraunhofer JA. Light transmission through all-ceramic dental materials: a pilot study. J Prosthet Dent. 2004;91:441–446. doi: 10.1016/S0022391304001106. [DOI] [PubMed] [Google Scholar]
  • 60.Rodrigues RF, Ramos CM, Francisconi PA, Borges AF. The shear bond strength of self-adhesive resin cements to dentin and enamel: an in vitro study. J Prosthet Dent. 2015;113:220–227. doi: 10.1016/j.prosdent.2014.08.008. [DOI] [PubMed] [Google Scholar]
  • 61.Rueggeberg FA, Caughman WF. The influence of light exposure on polymerization of dual-cure resin cements. Oper Dent. 1993;18:48–55. [PubMed] [Google Scholar]
  • 62.Runnacles P, Correr GM, Baratto F, Filho, Gonzaga CC, Furuse AY. Degree of conversion of a resin cement light-cured through ceramic veneers of different thicknesses and types. Braz Dent J. 2014;25:38–42. doi: 10.1590/0103-6440201302200. [DOI] [PubMed] [Google Scholar]
  • 63.Sanares AM, Itthagarun A, King NM, Tay FR, Pashley DH. Adverse surface interactions between one-bottle light-cured adhesives and chemical-cured composites. Dent Mater. 2011;17:542–556. doi: 10.1016/s0109-5641(01)00016-1. [DOI] [PubMed] [Google Scholar]
  • 64.Santos GC Jr, El-Mowafy O, Rubo JH, Santos MJ. Hardening of dual-cure resin cements and a resin composite restorative cured with QTH and LED curing units. J Can Dent Assoc. 2004;70:323–328. [PubMed] [Google Scholar]
  • 65.Schmid-Schwap M, Franz A, König F, Bristela M, Lucas T, Piehslinger E, et al. Cytotoxicity of four categories of dental cements. Dent Mater. 2009;25:360–368. doi: 10.1016/j.dental.2008.08.002. [DOI] [PubMed] [Google Scholar]
  • 66.Selz CF, Strub JR, Vach K, Guess PC. Long-term performance of posterior InCeram Alumina crowns cemented with different luting agents: a prospective, randomized clinical split-mouth study over 5 years. Clin Oral Investig. 2014;18:1695–1703. doi: 10.1007/s00784-013-1137-6. [DOI] [PubMed] [Google Scholar]
  • 67.Silva EM, Noronha JD, Filho, Amaral CM, Poskus LT, Guimarães JG. Long-term degradation of resin-based cements in substances present in the oral environment: influence of activation mode. J Appl Oral Sci. 2013;21:271–277. doi: 10.1590/1679-775720130026. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 68.Sjögren G, Molin M, van Dijken JW. A 10-year prospective evaluation of CAD/CAM-manufactured (Cerec) ceramic inlays cemented with a chemically cured or dual-cured resin composite. Int J Prosthodont. 2004;17:241–246. [PubMed] [Google Scholar]
  • 69.Souza EJ, Junior, Prieto LT, Soares GP, Dias CT, Aguiar FH, Paulillo LA. The effect of curing light and chemical catalyst on the degree of conversion of two dual cured resin luting cements. Lasers Med Sci. 2012;27:145–151. doi: 10.1007/s10103-010-0857-y. [DOI] [PubMed] [Google Scholar]
  • 70.Suh BI, Feng L, Pashley DH, Tay FR. Factors contributing to the incompatibility between simplified-step adhesives and chemically-cured or dual-cured composites. Part III. Effect of acidic resin monomers. J Adhes Dent. 2003;5:267–282. [PubMed] [Google Scholar]
  • 71.Svizero NR, Silva MS, Alonso RC, Rodrigues FP, Hipólito VD, Carvalho RM, et al. Effects of curing protocols on fluid kinetics and hardness of resin cements. Dent Mater J. 2013;32:32–41. doi: 10.4012/dmj.2012-085. [DOI] [PubMed] [Google Scholar]
  • 72.Tay FR, Pashley DH, Garcia-Godoy F, Yiu CK. Single-step, self-etch adhesives behave as permeable membranes after polymerization. Part II. Silver tracer penetration evidence. Am J Dent. 2004;17:315–322. [PubMed] [Google Scholar]
  • 73.Tezvergil-Mutluay A, Lassila LV, Vallittu PK. Degree of conversion of dual-cure luting resins light-polymerized through various materials. Acta Odontol Scand. 2007;65:201–205. doi: 10.1080/00016350701311632. [DOI] [PubMed] [Google Scholar]
  • 74.Truffier-Boutry D, Demoustier-Champagne S, Devaux J, Biebuyck JJ, Mestdagh M, Larbanois P, et al. A physico-chemical explanation of the post-polymerization shrinkage in dental resins. Dent Mater. 2006;22:405–412. doi: 10.1016/j.dental.2005.04.030. [DOI] [PubMed] [Google Scholar]
  • 75.Uctasli S, Hasanreisoglu U, Wilson HJ. The attenuation of radiation by porcelain and its effect on polymerization of resin cements. J Oral Rehabil. 1994;21:565–575. doi: 10.1111/j.1365-2842.1994.tb01171.x. [DOI] [PubMed] [Google Scholar]
  • 76.Uhl A, Michaelis C, Mills RW, Jandt KD. The influence of storage and indenter load on the Knoop hardness of dental composites polymerized with LED and halogen technologies. Dent Mater. 2004;20:21–28. doi: 10.1016/s0109-5641(03)00054-x. [DOI] [PubMed] [Google Scholar]
  • 77.Vrochari AD, Eliades G, Hellwig E, Wrbas KT. Curing efficiency of four self-etching, self-adhesive resin cements. Dent Mater. 2009;25:1104–1108. doi: 10.1016/j.dental.2009.02.015. [DOI] [PubMed] [Google Scholar]
  • 78.Watts DC, Cash AJ. Analysis of optical transmission by 400-500 nm visible light into aesthetic dental biomaterials. J Dent. 1994;22:112–117. doi: 10.1016/0300-5712(94)90014-0. [DOI] [PubMed] [Google Scholar]
  • 79.Yan YL, Kim YK, Kim KH, Kwon TY. Changes in degree of conversion and microhardness of dental resin cements. Oper Dent. 2010;35:203–210. doi: 10.2341/09-174-L. [DOI] [PubMed] [Google Scholar]
  • 80.Zhang X, Wang F. Hardness of resin cement cured under different thickness of lithium disilicate-based ceramic. Chin Med J. 2011;124:3762–3767. Engl. [PubMed] [Google Scholar]

Articles from Journal of Applied Oral Science are provided here courtesy of Bauru School of Dentistry

RESOURCES