Abstract
Background
Biopsy needles have recently been developed to obtain both cytological and histological specimens during endoscopic ultrasound (EUS). We conducted this study to compare 22-gauge (G) fine needle aspiration (FNA) needles, which have been the most frequently used, and new 25G fine needle biopsy (FNB) needles for EUS-guided sampling of solid pancreatic masses.
Methods
We conducted a retrospective cohort study of all EUS-guided sampling performed between June 2010 and October 2013. During the study period, 76 patients with pancreatic masses underwent EUS-guided sampling with a 22G FNA needle (n = 38) or a 25G FNB needle (n = 38) for diagnosis. An on-site cytopathologist was not present during the procedure. Technical success, the number of needle passes, cytological diagnostic accuracy, cytological sample quality (conventional smear and liquid-based preparation), histological diagnostic accuracy, and complications were reviewed and compared.
Results
There were no significant differences in technical success (100 % for both), the mean number of needle passes (5.05 vs. 5.55, P = 0.132), or complications (0 % for both) between the 22G FNA group and the 25G FNB group. The 22G FNA and 25G FNB groups exhibited comparable outcomes with respect to cytological diagnostic accuracy (97.4 % vs. 89.5 %, P = 0.358) and histological diagnostic accuracy (34.2 % vs. 52.6 %, P = 0.105). In the cytological sample quality analysis, the 25G FNB group exhibited higher scores for the amount of diagnostic cellular material present (22G FNA: 0.92 vs. 25G FNB: 1.32, P = 0.030) and the retention of appropriate architecture (22G FNA: 0.97 vs. 25G FNB: 1.42, P = 0.010) in the liquid-based preparation. The 25G FNB group showed a better histological diagnostic yield for specific tumor discrimination compared with the 22G FNA group (60 % vs. 32.4 %, P = 0.018).
Conclusions
Use of the 25G FNB needle was technically feasible, safe, efficient, and comparable to use of the standard 22G FNA needle in patients with solid pancreatic masses in the absence of an on-site cytopathologist. The cytological sample quality in the liquid-based preparation and the histological diagnostic yield for specific tumor discrimination of EUS-guided sampling using a 25G FNB needle were significantly higher than those using a 22G FNA needle.
Keywords: Endoscopic ultrasound, EUS-guided fine needle aspiration, Pancreatic mass
Background
Patients with pancreatic cancer have a dismal prognosis, with a 5-year survival rate of approximately 5 %. Therefore, rapid and correct diagnosis of a pancreatic mass is required to guide subsequent patient management. Endoscopic ultrasound (EUS)-guided fine needle aspiration (FNA) is the current standard method for obtaining tissue for the diagnosis of pancreatic masses [1, 2]. The reported results of pancreatic EUS-FNA vary in the range of 64–95 % for sensitivity, 75–100 % for specificity, and 78–95 % for diagnostic accuracy [3–5]. Several factors can affect the results of EUS-FNA, such as the experience of the endosonographer, the position of the endoscope, the diameter of the needle, the number of passes, and the presence of an on-site cytopathologist [6–11]. Furthermore, core biopsy specimens for assessing architectural features may be essential for diagnosing certain neoplasms, such as lymphomas and stromal cell tumors [12–14]. On-site cytological evaluation of EUS-FNA specimens by a cytopathologist has also been reported to increase the diagnostic yield [7, 15]. However, cost and staffing limitations frequently limit the availability of an on-site cytopathologist at many centers.
The 22-gauge (G) FNA needle has been the most commonly used for EUS-FNA of pancreatic masses [9, 11]. Both 19G and 22G fine needle biopsy (FNB) needles with a reverse-bevel to trap core specimens were developed to obtain core biopsy specimens. The results have indicated high yields of core specimens and fewer passes to provide adequate samples [16, 17]. However, a 25G FNA needle may be less traumatic and easier to manipulate when the tip of the echoendoscope is completely angulated. The aspirate obtained with a 25G FNA needle may also be less hemorrhagic and more adequate for interpretation by cytologists [18]. In fact, a new 25G FNB needle with a reverse-bevel-sided hole to obtain core specimens for histological evaluation is available. However, there is little data to support the use of the 25G FNB needle for EUS-guided sampling of pancreatic masses. The aim of the present study was to evaluate the feasibility, safety, and diagnostic adequacy of the 25G FNB needle in patients with solid pancreatic masses and to compare its performance with that of the widely used standard 22G FNA needle without on-site cytopathological examination.
Methods
Patients
We conducted a retrospective cohort study of all EUS-guided sampling performed between June 2010 and October 2013 at a single tertiary referral hospital (Ajou University Hospital, Suwon, Korea). The EUS database at our institution was searched for prospectively collected data on patients with solid pancreatic mass lesions who underwent EUS-guided sampling. During the study period, we performed 108 consecutive cases of EUS-guided sampling including 76 cases of solid pancreatic lesions, 16 cases of gastric subepithelial tumors, 12 cases of lymph nodes, and 4 cases of esophageal subepithelial tumors. The 25G FNB needle is a smaller-gauge needle and has a side bevel for the acquisition of core specimens; we believed that its smaller size would allow greater flexibility in puncturing tissue when the tip of the echoendoscope was completely angulated and that the side bevel could obtain core specimens, which could improve the diagnostic yield of targeted lesions. Thus, since the 25G FNB needle system with reverse-bevel technology for the acquisition of core specimens was introduced at this hospital (June 2012), we have used the needle exclusively for all EUS-guided sampling. In total, 38 patients were included in the 22G FNA group, and 38 patients were included in the 25G FNB group. The medical records of the patients were reviewed using a standardized data-entry form that included patient demographics, clinical findings, procedural complications, follow-up, and pathological findings. The results of EUS-guided sampling were confirmed using the following criteria: surgical histopathology, clinical follow-up for a minimum of 6 months, and/or the results of other diagnostic tests. This study was approved by the Institutional Review Board of the Ajou University Hospital (AJIRB-MED-MDB-13-327), and informed consent was obtained from all patients for whom EUS-guided sampling was performed.
EUS-guided sampling technique
EUS-guided sampling was performed using a linear array echoendoscope (GF-UCT 2000; Olympus Optical, Tokyo, Japan) in hospitalized patients. Each patient was sedated with standard doses of midazolam, propofol, and meperidine. After the optimal puncture site was determined, a puncture was made using a 22G FNA needle (Echotip Ultra; Cook Ireland Ltd., Limerick, Ireland) or a 25G FNB needle (Echotip ProCore; Cook Ireland Ltd., Limerick, Ireland) under EUS image guidance (Fig. 1). All pancreatic head and uncinate process masses were approached via the duodenum, and all pancreatic body and tail masses were approached via the stomach. After the lesion was punctured, the stylet was removed, and suction was applied using a 10-mL syringe. On every pass, the needle was moved to and fro within the lesion 10–15 times in a fanning manner.
An on-site cytopathologist was not present during EUS-guided sampling. The needle stylet was used to gradually push the tissue material out of the needle. The materials obtained on the first pass of EUS-guided sampling were mounted onto slides for conventional smear (CS) with alcohol fixation, and the materials obtained from the following pass of EUS-guided sampling were placed into an ethanol-based preservative (CytoRichRed™; Becton-Dickinson Diagnostics, Burlington, NC, USA) for SurePath™ (Becton-Dickinson Diagnostics, Burlington, NC, USA), a liquid-based preparation (LBP). If the materials for CS or LBP that were assessed macroscopically by the endosonographer were insufficient, more passes of EUS-guided sampling for CS or LBP were performed. After we obtained the material for CS and LBP, additional passes were performed to obtain histological specimens. The extruded material was placed onto glass slides for primary inspection by conventional smear or histological examination. In liquid-based preparations, the material in the needle was directly expelled into an ethanol-based preservative solution for SurePath™. The aspirated material for histological examination was assessed macroscopically by the endosonographer. Macroscopically sufficient material for histological evaluation was defined as one or more small-core biopsy cylinders. If one or more small-core biopsy cylinders were acquired, the tissue material was placed in formalin solution. The number of needle passes to obtain a histological specimen was limited to 2 to prevent procedure-related complications.
Preparation of specimens and sample quality
Papanicolaou stain was applied to both CS and LBP slides. Histological diagnosis of biopsy specimens was carried out for hematoxylin-eosin stained specimens. We performed immunochemical staining of LBP slides or histological specimens for synaptophysin, chromogranin, MIB-1, beta-catenin, CD 10, CD 56, CD 99, and PR in selected cases that were suspected to contain pseudopapillary tumors, neuroendocrine tumors or metastatic tumors.
For the assessment of cytological sample quality, the scoring system reported by Mair et al. [19] was used (Table 1). The two techniques for EUS-guided sampling were compared based on the following parameters: (1) the amount of diagnostic cellular material present, (2) the retention of appropriate architecture and cellular arrangement, (3) the degree of cellular degeneration, (4) the degree of cellular trauma, and (5) the volume of obscuring background blood or clot. The assessment of cytological sample quality using this scoring system is not daily clinical practice in our pathological department, and it was performed retrospectively only for this study by one cytopathologist (HY) who was blinded to the type of the needle and the results from the other preparation technique for every case. Two pathologists (YBK and DL) participated in the histological examinations, which were performed at the time of diagnosis, and we retrospectively reviewed the pathologic reports for histological assessment.
Table 1.
Parameter | Description | Score |
---|---|---|
Amount of cellular material | Minimal to absent; diagnosis not possible | 0 |
Sufficient for cytodiagnosis | 1 | |
Abundant; diagnosis simple | 2 | |
Retention of appropriate architecture | Minimal to absent; nondiagnostic | 0 |
Moderate; some preservation | 1 | |
Excellent; diagnosis obvious | 2 | |
Degree of cellular degeneration | Marked; diagnosis impossible | 0 |
Moderate; diagnosis possible | 1 | |
Minimal; good preservation; diagnosis easy | 2 | |
Degree of cellular trauma | Marked; diagnosis not possible | 0 |
Moderate; diagnosis possible | 1 | |
Minimal; diagnosis obvious | 2 | |
Background blood or clot | Large amount; great compromise to diagnosis | 0 |
Moderate amount; diagnosis possible | 1 | |
Minimal; diagnosis easy; specimen of “textbook” quality | 2 |
Outcome parameters
The primary outcome parameter was diagnostic accuracy, which was defined as the ratio between the sum of true positive and true negative values divided by the total number of lesions for diagnosing neoplasia versus benign (non-neoplastic) conditions. Malignant and suspicious lesions (diagnosed by cytopathology on samples obtained using EUS-guided sampling) that were eventually diagnosed as malignant were considered to be true positives. We did not include atypical cytopathology results as positives for malignancy. The secondary outcome measures were technical failure, the number of needle passes, complications, cytological sample quality, and the ability to provide a specific tissue diagnosis, e.g., adenocarcinoma, metastasis, neuroendocrine tumor, or pseudopapillary tumor, for cases of neoplasia. Early and late complications were defined as any EUS-guided sampling-related complication within 30 days and after 30 days of the procedure, respectively. Serum amylase levels, complete blood counts, and abdominal radiographs were checked on the day following EUS-guided sampling to monitor complications such as bleeding, perforation, and acute pancreatitis. All patients were instructed to let us know if any symptoms suggestive of a complication were noted. Additional information regarding current status was obtained via direct contact with the referring physician.
Statistical analysis
Statistical analysis was performed using the chi-square test or Fisher’s exact test for categorical parameters and Student’s t-test for continuous variables. Analyses were performed using SPSS for Windows (version 18.0; SPSS Inc., Chicago, IL, USA), with quantitative data presented as the mean ± standard deviation. Statistical significance was set at a P value of < 0.05.
Results
Demographic data for the 76 study patients are shown in Table 2. There was no significant difference between the 22G FNA group and the 25G FNB group with regard to the male-to-female ratio, age, mass size, mass location, or final diagnosis. Surgical histopathology was available for 10 cases in the 22G FNA group and three cases in the 25G FNB group. The residual cases were corroborated by clinical follow-up. The median follow-up was 239 days in the 22G FNA group and 253 days in the 25G FNB group. After EUS-guided sampling, 39/64 patients with pancreatic adenocarcinoma or metastasis received chemoradiation, seven underwent surgical resection, and 18 were managed conservatively. Additionally, four patients with neuroendocrine tumors and two patients with pseudopapillary tumors underwent surgical resection. None of the six patients with chronic pancreatitis exhibited disease progression during clinical follow-up.
Table 2.
22-gauge FNA (n = 38) | 25-gauge FNB (n = 38) | P value | |
---|---|---|---|
Sex (male/female) | 17/21 | 18/20 | 0.818 |
Age (years) | 61.8 ± 11.4 | 63.0 ± 12.6 | 0.669 |
Size of mass on EUS (mm) | 34.1 ± 12.6 | 33.8 ± 16.3 | 0.931 |
Tumor location, no. (%) | 0.359 | ||
Head/uncinate | 21 (55.3) | 17 (44.7) | |
Body/tail | 17 (44.7) | 21 (55.3) | |
Final diagnosis, no. (%) | 0.187 | ||
Adenocarcinoma | 33 (86.8) | 29 (76.3) | |
Metastasis | 0 (0) | 2 (5.3) | |
Neuroendocrine tumor | 3 (7.9) | 1 (2.6) | |
Pseudopapillary tumor | 1 (2.6) | 1 (2.6) | |
Chronic pancreatitis | 1 (2.6) | 5 (13.2) |
EUS endoscopic ultrasound, FNA fine needle aspiration, FNB fine needle biopsy
Continuous variables are expressed as the mean ± standard deviation
There was no significant difference in the access route, the technical success rate, cytological diagnostic accuracy, or histological diagnostic accuracy between the two groups (Table 3). The technical success rate was 100 % in both groups. The overall diagnostic accuracy regarding pancreatic masses was consistent with the cytological diagnostic accuracy in both groups. In particular, the cytological diagnostic accuracy was 97.4 % (37/38) in the 22G FNA group and 89.5 % (34/38) in the 25G FNB group (P = 0.358). There was no significant difference in the diagnostic accuracy between CS and LBP within the groups (22G FNA: 89.5 % [34/38] vs. 76.3 % [29/38], P = 0.128; 25G FNB: 84.2 % [32/38] vs. 84.2 % [32/38], P = 1.000). In the cytological diagnosis of the 22G FNA and 25G FNB groups, CS complemented LBP in eight cases and two cases, respectively, and LBP complemented CS in three cases and two cases, respectively. In the sample quality analysis, the two sampling techniques with CS demonstrated similar scores for the amount of diagnostic cellular material present, the retention of appropriate architecture and cellular arrangement, the degree of cellular degeneration, the degree of cellular trauma, and the volume of obscuring background blood or clot (Table 4). For LBP, the 25G FNB group exhibited higher scores for the amount of diagnostic cellular material present (22G FNA: 0.92 vs. 25G FNB: 1.32, P = 0.030) and the retention of appropriate architecture (22G FNA: 0.97 vs. 25G FNB: 1.42, P = 0.010) (Table 5). The rate of acquiring sufficient material, as assessed macroscopically by the endosonographer for histological evaluation, was not significantly different between groups (22G FNA 60.5 % vs. 25G FNB 68.4 %, P = 0.472). The histological diagnostic accuracy regarding pancreatic masses was 34.2 % (13/38) in the 22G FNA group and 52.6 % (20/38) in the 25G FNB group (P = 0.105). The results for both cytology and histology in distinguishing tumor types are shown in Table 6. For cytology, there was no difference between the 22G FNA group and the 25G FNB group. For histology, the 25G FNB group demonstrated a better diagnostic yield for specific tumor discrimination compared with the 22G FNA group (20/33, 60.6 % vs. 12/37, 32.4 %; P = 0.018). There was no significant difference in the mean number of needle passes between the groups (22G FNA: 5.05 vs. 25G FNB: 5.55, P = 0.132) (Table 3). No early or late complications were identified in either group.
Table 3.
22-gauge FNA (n = 38) | 25-gauge FNB (n = 38) | P value | |
---|---|---|---|
Access route, no (%) | 0.359 | ||
Transgastric | 17 (44.7) | 21 (55.3) | |
Transduodenal | 21 (55.3) | 17 (44.7) | |
Cytological diagnostic accuracy, no. (%) | 37 (97.4) | 34 (89.5) | 0.358 |
Histological diagnostic accuracy, no. (%) | 13 (34.2) | 20 (52.6) | 0.105 |
Failure to achieve diagnosis, no. (%) | |||
Total | 1 (2.6) | 4 (10.5) | 0.358 |
Technical failure | 0 | 0 | |
Diagnostic failure | 1 (2.6) | 4 (10.5) | 0.358 |
No. of passes for diagnosis | 5.05 ± 1.45 | 5.55 ± 1.41 | 0.132 |
Complication, no. (%) | 0 | 0 |
EUS endoscopic ultrasound, FNA fine needle aspiration, FNB fine needle biopsy
Continuous variables are expressed as the mean ± standard deviation
Table 4.
22-gauge FNA (n = 38) | 25-gauge FNB (n = 38) | P value | |
---|---|---|---|
Amount of cellular material | 1.26 ± 0.72 | 1.55 ± 0.72 | 0.085 |
Retention of appropriate architecture | 1.39 ± 0.68 | 1.63 ± 0.67 | 0.132 |
Degree of cellular degeneration | 1.42 ± 0.60 | 1.58 ± 0.64 | 0.271 |
Degree of cellular trauma | 1.26 ± 0.55 | 1.53 ± 0.65 | 0.061 |
Background blood or clot | 1.29 ± 0.70 | 1.53 ± 0.73 | 0.150 |
Total score | 6.63 ± 2.90 | 7.82 ± 3.14 | 0.092 |
FNA fine needle aspiration, FNB fine needle biopsy
Continuous variables are expressed as the mean ± standard deviation
a The scoring system reported by Mair et al. [19] was used for the assessment of sample quality
Table 5.
22-gauge FNA (n = 38) | 25-gauge FNB (n = 38) | P value | |
---|---|---|---|
Amount of cellular material | 0.92 ± 0.78 | 1.32 ± 0.78 | 0.030 |
Retention of appropriate architecture | 0.97 ± 0.75 | 1.42 ± 0.72 | 0.010 |
Degree of cellular degeneration | 1.37 ± 0.75 | 1.61 ± 0.60 | 0.132 |
Degree of cellular trauma | 1.26 ± 0.72 | 1.47 ± 0.60 | 0.173 |
Background blood or clot | 1.11 ± 0.69 | 1.24 ± 0.71 | 0.416 |
Total score | 5.63 ± 3.32 | 7.05 ± 3.00 | 0.054 |
FNA fine needle aspiration, FNB fine needle biopsy
Continuous variables are expressed as the mean ± standard deviation
a The scoring system reported by Mair et al. [19] was used for the assessment of sample quality
Table 6.
22-gauge FNA | 25-gauge FNB | |||||
---|---|---|---|---|---|---|
Specific diagnosis | CS | LBP | Histology | CS | LBP | Histologyb |
Adenocarcinoma | 27/33 | 23/33 | 10/33 | 24/29 | 23/29 | 18/29 |
Metastasis | 0/0 | 0/0 | 0/0 | 0/2 | 1/2 | 1/2 |
Neuroendocrine tumor | 0/3 | 2/3 | 1/3 | 0/1 | 1/1 | 1/1 |
Pseudopapillary tumor | 0/1 | 1/1 | 1/1 | 0/1 | 1/1 | 0/1 |
Total | 27/37 | 23/37 | 12/37 | 24/33 | 26/33 | 20/33 |
FNA fine needle aspiration, FNB fine needle biopsy, CS conventional smear, LBP liquid-based preparation
aOnly neoplastic cases are included
bThe 25-gauge FNB group showed a better diagnostic yield in terms of specific tumor discrimination compared with the 22-gauge FNA group (P = 0.018)
Discussion
In the current study, which compared the diagnostic yield and performance of the 25G FNB needle with the standard 22G FNA needle for the evaluation of pancreatic solid masses without on-site evaluation of specimens, the diagnostic yield, technical performance, and safety profile of the 25G FNB needle were comparable to those of the 22G FNA needle. Although our study failed to demonstrate the superiority of the 25G FNB needle over the 22G FNA needle in terms of the overall histological diagnostic yield, the 25G FNB group demonstrated a better histological diagnostic yield for specific tumor discrimination compared with the 22G FNA group.
Needle selection for EUS-guided sampling can be a complex process in clinical practice. The 22G FNA needle has been the most frequently used for EUS-FNA of pancreatic masses [9, 11], but the 25G FNA needle could be particularly useful for targeting lesions requiring extreme scope bending, as its smaller caliber and greater flexibility allow it to puncture tissue in hard pancreatic masses more easily [10]. This needle can also provide less bloody and less contaminated specimens, which may facilitate on-site interpretation [9, 10]. However, one meta-analysis reported no significant differences in accuracy, complication rates, the number of needle passes, or needle visibility when comparing 22G and 25G FNA needles [20]. In the present study, although there was no significant difference, there was a trend toward a higher score for background blood or clot in the samples from both the conventional smear and liquid-based preparations in the 25G FNB group compared with the 22G FNA group. Although cytological examination of EUS-FNA specimens enables us to detect malignancies, particular neoplasms such as lymphomas and gastrointestinal stromal tumors may be difficult to diagnose without histological specimens. Additionally, histology may be required for better, more specific characterization of pancreatic neoplasms other than adenocarcinomas [21, 22]. In fact, Möller et al. [22] reported that combining EUS-FNA cytology and histology with the 22G FNA needle significantly increased the sensitivity of malignancy diagnosis compared with cytology or histology alone. The sensitivity of histology alone was only 60 %, and the sensitivity of cytology alone was 68.1 %. Combining cytology and histology improved sensitivity to 82.9 %. In our study, the overall diagnostic accuracy regarding pancreatic masses was consistent with the cytological diagnostic accuracy in both groups. There was no improvement in diagnostic accuracy with the combination of cytology and histology. In the study by Möller et al. [22], core specimens were harvested for histological analysis first, and the remaining material was examined cytologically; however, in our study, samples for histological analysis were collected after tissue acquisition for cytological analysis. This different order may have caused the difference in the results. Recently, FNB needles of various sizes with a reverse-bevel-sided hole were developed to acquire core specimens for histological assessment. In a study of the 19G FNB needle by Iglesias-Garcia et al. [16], sample quality for histology was adequate in 45/47 pancreatic lesions (95.7 %), and correct diagnosis based solely on histology was provided in 42/47 (89.4 %), with two technical failures in the transduodenal approach. The needle emerged from the echoendoscope with difficulty in 18 % of cases, and this technical difficulty was experienced when the transduodenal approach was performed because of the rigidity induced by its 19G caliber and the curved position of the echoendoscope in the duodenum. In another study, Bang et al. [23] compared the performance of the 22G FNA needle and the 22G FNB needle in 56 patients with solid pancreatic masses. The specimens obtained were reviewed by an on-site cytopathologist to ascertain sample adequacy after each pass. In that study, there was no significant difference in the median number of needle passes (1 vs. 1, P = 0.21), technical failure (0 vs. 3.6 %, P = 1.0), the rates of diagnostic sufficiency (100 % vs. 89.3 %, P = 0.24), or the presence of diagnostic histological specimens (66.7 % vs. 80 %, P = 0.66) between the FNA and the FNB cohorts. Although the small-caliber 22G FNB needle obtained an adequate sample for cytological analysis, the quantity and quality of the acquired tissue appeared to be unsatisfactory for histological assessment. The histological diagnostic yield of the 22G FNA needle in our study (34.2 %) was lower than that reported by the previous study (66.7 %). There is one explanation that may contribute to this difference. In the study of Bang et al., the specimens obtained with the 22G FNA needle underwent cell block analysis for histological assessment, and some studies have shown that cell block is a valid technique for performing histological assessments and can improve the diagnostic accuracy of smears [24–26]. In our study, the specimens for histological examination were placed in formalin solution, and the cell block technique was not used for histological assessment. In the present study, we observed no technical failure in either group, and there was no significant difference in cytological diagnostic accuracy between the groups. Although there was no statistically significant difference for CS, there was a trend toward higher scores for all categories in the sample quality analysis in the 25G FNB group compared with the 22G FNA group. Moreover, the 25G FNB group exhibited higher scores for the amount of diagnostic cellular material and the retention of appropriate architecture when LBP was used. In addition, there was a trend toward the 25G FNB needle exhibiting higher overall histological diagnostic accuracy than the 22G FNA needle (52.6 % vs. 34.2 %, P = 0.105), and the 25G FNB group showed a better histological diagnostic yield in specific tumor discrimination compared with the 22G FNA group (60.6 % vs. 32.4 %, P = 0.018). However, these results were unsatisfactory compared with those of previous studies, which used larger-gauge FNB needles [16, 23]. In the present study, samples for histological analysis were collected after tissue acquisition for cytological analysis, which was somewhat biased against histology. We performed EUS-guided sampling in inoperable solid pancreatic lesions and solid pancreatic lesions, in which it was difficult to differentiate between malignant and benign lesions in other diagnostic tests. Because cytology is more sensitive than histology alone for the diagnosis of pancreatic malignancies [27], we first obtained specimens for cytological examination. After the material for cytological examination was obtained, we restricted the number of needle passes for obtaining histological specimens to 2 to prevent procedure-related complications such as pancreatitis, bleeding, bile peritonitis or malignant seeding [28]. These factors may be related to the relatively low histological diagnostic yield compared with previous studies, which used larger-gauge FNB needles [16, 23]. A specimen obtained using a smaller-gauge needle may be less hemorrhagic and more adequate for cytological diagnosis. However, blood contamination does not decrease the histological diagnostic yield. Although we believe that the side bevel of the 25G FNB needle can allow cells to move into the needle more easily, larger-gauge FNB needles can offer a greater chance of obtaining an intact histological core. Prospective comparative studies are needed to evaluate the histological diagnostic yield of FNB needles of different sizes.
Previous studies recommended performing 5–7 passes of EUS-FNA for pancreatic masses [29–31]. In the present study, there was no significant difference in the mean number of passes required to make a diagnosis between the two groups (22G FNA: 5.05 vs. 25G FNB: 5.55, P = 0.132). Although we performed more passes to obtain a diagnosis with the FNA or FNB needle than in previous studies (mean number of passes for diagnosis: 1.28–2.78) [11, 22, 23], complications were not observed in either group.
Our patient group was small, and the study was limited by its retrospective nature. We divided the patients chronologically, according to the time period during which the needles were used, into two groups. Therefore, the bias-related improvements in the techniques of the operator may have been introduced. Another limitation of our study was the lack of surgical histopathology in many patients and the relatively short follow-up, during which all of our patients with pancreatic adenocarcinoma or metastasis exhibited disease progression. In contrast, none of the patients with chronic pancreatitis exhibited disease progression after a minimum of 6 months of follow-up. This follow-up period was adopted from similar studies [16, 23]. In the present study, it was also not possible to blind the endosonographer to the type of needle used, which may have introduced bias. However, this feature may not have been a significant limitation because the pathologists were blinded to the type of needle used for EUS-guided sampling.
Conclusions
The 25G FNB needle was safe, reliably provided cytological diagnosis, and was comparable to the standard 22G FNA needle in patients with solid pancreatic masses in the absence of an on-site cytopathologist. The cytological sample quality in liquid-based preparation and the histological diagnostic yield for specific tumor discrimination of EUS-guided sampling using a 25G FNB needle were significantly higher than those using a 22G FNA needle.
Acknowledgments
None.
Abbreviations
- EUS
Endoscopic ultrasound
- G
Gauge
- FNA
Fine needle aspiration
- FNB
Fine needle biopsy
- CS
Conventional smear
- LBP
Liquid-based preparation
Footnotes
Min Jae Yang and Hyunee Yim share first authorship.
Min Jae Yang and Hyunee Yim contributed equally to this work.
Competing interests
The authors declare that they have no competing interests.
Authors’ contributions
MJY, HY and JCH participated in the conception and design of the study; JCH performed the EUS procedures; HY performed the cytological examinations; YBK and DL performed the histological examinations; MJY, HY and JCH participated in the analysis and interpretation of the data; MJY, JCH, SGL, SSK, JKK, BMY and JHK were responsible for pre- and post-procedure patient care; MJY, HY and JCH were responsible for writing the manuscript and revising it critically for important intellectual content. All authors read and approved the final manuscript.
Authors’ information
Not applicable.
Contributor Information
Min Jae Yang, Email: creator1999@hanmail.net.
Hyunee Yim, Email: hyuneeyim@naver.com.
Jae Chul Hwang, Email: cath07@naver.com.
Dakeun Lee, Email: dakeun@ajou.ac.kr.
Young Bae Kim, Email: ybkim@ajou.ac.kr.
Sun Gyo Lim, Email: mdlsk75@hanmail.net.
Soon Sun Kim, Email: cocorico99@gmail.com.
Joon Koo Kang, Email: pellucida@hotmail.com.
Byung Moo Yoo, Email: ybm6403@gmail.com.
Jin Hong Kim, Email: jinhkim@ajou.ac.kr.
References
- 1.Fritscher-Ravens A, Topalidis T, Bobrowski C, Krause C, Thonke E, Jackle S, et al. Endoscopic ultrasound-guided fine-needle aspiration in focal pancreatic lesions: a prospective intraindividual comparison of two needle assemblies. Endoscopy. 2001;33:484–90. doi: 10.1055/s-2001-14970. [DOI] [PubMed] [Google Scholar]
- 2.Shah JN, Ahmad NA, Beilstein MC, Ginsberg GG, Kochman ML. Clinical impact of endoscopic ultrasonography on the management of malignancies. Clin Gastroenterol Hepatol. 2004;2:1069–73. doi: 10.1016/S1542-3565(04)00444-6. [DOI] [PubMed] [Google Scholar]
- 3.Eloubeidi MA, Chen VK, Eltoum IA, Jhala D, Chhieng DC, Jhala N, et al. Endoscopic ultrasound-guided fine needle aspiration biopsy of patients with suspected pancreatic cancer: diagnostic accuracy and acute and 30-day complications. Am J Gastroenterol. 2003;98:2663–8. doi: 10.1111/j.1572-0241.2003.08666.x. [DOI] [PubMed] [Google Scholar]
- 4.Itoi T, Sofuni A, Itokawa F, Irisawa A, Khor CJ, Rerknimitr R. Current status of diagnostic endoscopic ultrasonography in the evaluation of pancreatic mass lesions. Dig Endosc. 2011;23(Suppl 1):17–21. doi: 10.1111/j.1443-1661.2011.01132.x. [DOI] [PubMed] [Google Scholar]
- 5.Yoshinaga S, Suzuki H, Oda I, Saito Y. Role of endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) for diagnosis of solid pancreatic masses. Dig Endosc. 2011;23(Suppl 1):29–33. doi: 10.1111/j.1443-1661.2011.01112.x. [DOI] [PubMed] [Google Scholar]
- 6.Wallace MB, Kennedy T, Durkalski V, Eloubeidi MA, Etamad R, Matsuda K, et al. Randomized controlled trial of EUS-guided fine needle aspiration techniques for the detection of malignant lymphadenopathy. Gastrointest Endosc. 2001;54:441–7. doi: 10.1067/mge.2001.117764. [DOI] [PubMed] [Google Scholar]
- 7.Klapman JB, Logrono R, Dye CE, Waxman I. Clinical impact of on-site cytopathology interpretation on endoscopic ultrasound-guided fine needle aspiration. Am J Gastroenterol. 2003;98:1289–94. doi: 10.1111/j.1572-0241.2003.07472.x. [DOI] [PubMed] [Google Scholar]
- 8.Mertz H, Gautam S. The learning curve for EUS-guided FNA of pancreatic cancer. Gastrointest Endosc. 2004;59:33–7. doi: 10.1016/S0016-5107(03)02028-5. [DOI] [PubMed] [Google Scholar]
- 9.Siddiqui UD, Rossi F, Rosenthal LS, Padda MS, Murali-Dharan V, Aslanian HR. EUS-guided FNA of solid pancreatic masses: a prospective, randomized trial comparing 22-gauge and 25-gauge needles. Gastrointest Endosc. 2009;70:1093–7. doi: 10.1016/j.gie.2009.05.037. [DOI] [PubMed] [Google Scholar]
- 10.Yusuf TE, Ho S, Pavey DA, Michael H, Gress FG. Retrospective analysis of the utility of endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) in pancreatic masses, using a 22-gauge or 25-gauge needle system: a multicenter experience. Endoscopy. 2009;41:445–8. doi: 10.1055/s-0029-1214643. [DOI] [PubMed] [Google Scholar]
- 11.Song TJ, Kim JH, Lee SS, Eum JB, Moon SH, Park do H, et al. The prospective randomized, controlled trial of endoscopic ultrasound-guided fine-needle aspiration using 22G and 19G aspiration needles for solid pancreatic or peripancreatic masses. Am J Gastroenterol. 2010;105:1739–45. doi: 10.1038/ajg.2010.108. [DOI] [PubMed] [Google Scholar]
- 12.Ribeiro A, Vazquez-Sequeiros E, Wiersema LM, Wang KK, Clain JE, Wiersema MJ. EUS-guided fine-needle aspiration combined with flow cytometry and immunocytochemistry in the diagnosis of lymphoma. Gastrointest Endosc. 2001;53:485–91. doi: 10.1067/mge.2001.112841. [DOI] [PubMed] [Google Scholar]
- 13.Levy MJ, Jondal ML, Clain J, Wiersema MJ. Preliminary experience with an EUS-guided trucut biopsy needle compared with EUS-guided FNA. Gastrointest Endosc. 2003;57:101–6. doi: 10.1067/mge.2003.49. [DOI] [PubMed] [Google Scholar]
- 14.Turner MS, Goldsmith JD. Best practices in diagnostic immunohistochemistry: spindle cell neoplasms of the gastrointestinal tract. Arch Pathol Lab Med. 2009;133:1370–4. doi: 10.5858/133.9.1370. [DOI] [PubMed] [Google Scholar]
- 15.Cleveland P, Gill KR, Coe SG, Woodward TA, Raimondo M, Jamil L, et al. An evaluation of risk factors for inadequate cytology in EUS-guided FNA of pancreatic tumors and lymph nodes. Gastrointest Endosc. 2010;71:1194–9. doi: 10.1016/j.gie.2010.01.029. [DOI] [PubMed] [Google Scholar]
- 16.Iglesias-Garcia J, Poley JW, Larghi A, Giovannini M, Petrone MC, Abdulkader I, et al. Feasibility and yield of a new EUS histology needle: results from a multicenter, pooled, cohort study. Gastrointest Endosc. 2011;73:1189–96. doi: 10.1016/j.gie.2011.01.053. [DOI] [PubMed] [Google Scholar]
- 17.Hucl T, Wee E, Anuradha S, Gupta R, Ramchandani M, Rakesh K, et al. Feasibility and efficiency of a new 22G core needle: a prospective comparison study. Endoscopy. 2013;45:792–8. doi: 10.1055/s-0033-1344217. [DOI] [PubMed] [Google Scholar]
- 18.Gerke H. EUS-guided FNA: better samples with smaller needles? Gastrointest Endosc. 2009;70:1098–100. doi: 10.1016/j.gie.2009.06.033. [DOI] [PubMed] [Google Scholar]
- 19.Mair S, Dunbar F, Becker PJ, Du Plessis W. Fine needle cytology--is aspiration suction necessary? A study of 100 masses in various sites. Acta Cytol. 1989;33:809–13. [PubMed] [Google Scholar]
- 20.Affolter KE, Schmidt RL, Matynia AP, Adler DG, Factor RE. Needle size has only a limited effect on outcomes in EUS-guided fine needle aspiration: a systematic review and meta-analysis. Dig Dis Sci. 2013;58:1026–34. doi: 10.1007/s10620-012-2439-2. [DOI] [PubMed] [Google Scholar]
- 21.Levy MJ, Wiersema MJ. EUS-guided Trucut biopsy. Gastrointest Endosc. 2005;62:417–26. doi: 10.1016/j.gie.2005.04.044. [DOI] [PubMed] [Google Scholar]
- 22.Moller K, Papanikolaou IS, Toermer T, Delicha EM, Sarbia M, Schenck U, et al. EUS-guided FNA of solid pancreatic masses: high yield of 2 passes with combined histologic-cytologic analysis. Gastrointest Endosc. 2009;70:60–9. doi: 10.1016/j.gie.2008.10.008. [DOI] [PubMed] [Google Scholar]
- 23.Bang JY, Hebert-Magee S, Trevino J, Ramesh J, Varadarajulu S. Randomized trial comparing the 22-gauge aspiration and 22-gauge biopsy needles for EUS-guided sampling of solid pancreatic mass lesions. Gastrointest Endosc. 2012;76:321–7. doi: 10.1016/j.gie.2012.03.1392. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 24.Kung IT, Chan SK, Lo ES. Application of the immunoperoxidase technique to cell block preparations from fine needle aspirates. Acta Cytol. 1990;34:297–303. [PubMed] [Google Scholar]
- 25.Mayall F, Chang B, Darlington A. A review of 50 consecutive cytology cell block preparations in a large general hospital. J Clin Pathol. 1997;50:985–90. doi: 10.1136/jcp.50.12.985. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 26.Kopelman Y, Marmor S, Ashkenazi I, Fireman Z. Value of EUS-FNA cytological preparations compared with cell block sections in the diagnosis of pancreatic solid tumours. Cytopathology. 2011;22:174–8. doi: 10.1111/j.1365-2303.2010.00766.x. [DOI] [PubMed] [Google Scholar]
- 27.Binmoeller KF, Thul R, Rathod V, Henke P, Brand B, Jabusch HC, et al. Endoscopic ultrasound-guided, 18-gauge, fine needle aspiration biopsy of the pancreas using a 2.8 mm channel convex array echoendoscope. Gastrointest Endosc. 1998;47:121–7. doi: 10.1016/S0016-5107(98)70343-8. [DOI] [PubMed] [Google Scholar]
- 28.Early DS, Acosta RD, Chandrasekhara V, Chathadi KV, Decker GA, Evans JA, et al. Adverse events associated with EUS and EUS with FNA. Gastrointest Endosc. 2013;77:839–43. doi: 10.1016/j.gie.2013.02.018. [DOI] [PubMed] [Google Scholar]
- 29.Erickson RA, Sayage-Rabie L, Beissner RS. Factors predicting the number of EUS-guided fine needle passes for diagnosis of pancreatic malignancies. Gastrointest Endosc. 2000;51:184–90. doi: 10.1016/S0016-5107(00)70416-0. [DOI] [PubMed] [Google Scholar]
- 30.Harewood GC, Wiersema MJ. Endosonography-guided fine needle aspiration biopsy in the evaluation of pancreatic masses. Am J Gastroenterol. 2002;97:1386–91. doi: 10.1111/j.1572-0241.2002.05777.x. [DOI] [PubMed] [Google Scholar]
- 31.LeBlanc JK, Ciaccia D, Al-Assi MT, McGrath K, Imperiale T, Tao LC, et al. Optimal number of EUS-guided fine needle passes needed to obtain a correct diagnosis. Gastrointest Endosc. 2004;59:475–81. doi: 10.1016/S0016-5107(03)02863-3. [DOI] [PubMed] [Google Scholar]