Full text
PDFSelected References
These references are in PubMed. This may not be the complete list of references from this article.
- BURGER H. C., KORSTEN J. J., NOORDERGRAAF A., ULLERSMA P. Physical basis of ballistocardiography. IV. The relative movement of subject and ballistocardiograph. Am Heart J. 1956 Nov;52(5):653–673. doi: 10.1016/0002-8703(56)90021-7. [DOI] [PubMed] [Google Scholar]
- BURGER H. C., NOORDERGRAAF A. Physical basis of ballistocardiography. III. Am Heart J. 1956 Feb;51(2):179–185. doi: 10.1016/0002-8703(56)90079-5. [DOI] [PubMed] [Google Scholar]
- DAVIS F. W., Jr, SCARBOROUGH W. R., MASON R. E., SINGEWALD M. L., BAKER B. M., Jr The ballistocardiographic cigarette test: further observations. Am Heart J. 1956 Feb;51(2):165–178. doi: 10.1016/0002-8703(56)90078-3. [DOI] [PubMed] [Google Scholar]
- DOCK W., TAUBMAN F. Some technics for recording the ballistocardiogram directly from the body. Am J Med. 1949 Dec;7(6):751-5, illust. doi: 10.1016/0002-9343(49)90413-1. [DOI] [PubMed] [Google Scholar]
- NOORDEGRAAF A. Further studies on a theory of the ballistocardiogram. Circulation. 1961 Mar;23:413–425. doi: 10.1161/01.cir.23.3.413. [DOI] [PubMed] [Google Scholar]
- NOORDERGRAAF A., HEYNEKAMP C. E. Genesis of displacement of the human longitudinal ballistocardiogram from the changing blood distribution. Am J Cardiol. 1958 Dec;2(6):748–756. doi: 10.1016/0002-9149(58)90272-8. [DOI] [PubMed] [Google Scholar]
- NOORDERGRAAF A., VERDOUW D., BOOM H. B. The use of an analog computer in a circulation model. Prog Cardiovasc Dis. 1963 Mar;5:419–439. doi: 10.1016/s0033-0620(63)80009-2. [DOI] [PubMed] [Google Scholar]
- ORAM S., SOWTON E. Tobacco angina. Q J Med. 1963 Apr;32:115–143. [PubMed] [Google Scholar]
- SCARBOROUGH W. R., MASON R. E., DAVIS F. W., Jr, SINGEWALD M. L., BAKER B. M., Jr, LORE S. A. A ballistocardiographic and electrocardiographic study of 328 patients with coronary artery disease; comparison with results from similar study of apparently normal persons. Am Heart J. 1952 Nov;44(5):645–670. doi: 10.1016/0002-8703(52)90095-1. [DOI] [PubMed] [Google Scholar]
- SCARBOROUGH W. R. Some circulatory effects of morphine-barbiturate anesthesia, artificial respiration, and abdominal compression based on ballistocardiographic observation on dogs, with a review of pertinent literature. Am Heart J. 1957 Nov;54(5):651–677. doi: 10.1016/0002-8703(57)90420-9. [DOI] [PubMed] [Google Scholar]
- TALBOT S. A., HARRISON W. K., Jr Dynamic comparison of current ballistocardiographic methods. I. Artifacts in the dynamically simple ballistocardiographic methods. Circulation. 1955 Oct;12(4):577–587. doi: 10.1161/01.cir.12.4.577. [DOI] [PubMed] [Google Scholar]
- VON WITTERN W. W. Ballistocardiography with elimination of the influence of the vibration properties of the body. Am Heart J. 1953 Nov;46(5):705–714. doi: 10.1016/0002-8703(53)90223-3. [DOI] [PubMed] [Google Scholar]