Skip to main content
Revista Brasileira de Terapia Intensiva logoLink to Revista Brasileira de Terapia Intensiva
. 2015 Jul-Sep;27(3):284–292. doi: 10.5935/0103-507X.20150048

Endotracheal suctioning in intubated newborns: an integrative literature review

Aspiração endotraqueal em recém-nascidos intubados: uma revisão integrativa da literatura

Roberta Lins Gonçalves 1,2,, Lucila Midori Tsuzuki 1, Marcos Giovanni Santos Carvalho 3
PMCID: PMC4592124  PMID: 26465249

Abstract

Evidence-based practices search for the best available scientific evidence to support problem solving and decision making. Because of the complexity and amount of information related to health care, the results of methodologically sound scientific papers must be integrated by performing literature reviews. Although endotracheal suctioning is the most frequently performed invasive procedure in intubated newborns in neonatal intensive care units, few Brazilian studies of good methodological quality have examined this practice, and a national consensus or standardization of this technique is lacking. Therefore, the purpose of this study was to review secondary studies on the subject to establish recommendations for endotracheal suctioning in intubated newborns and promote the adoption of best-practice concepts when conducting this procedure. An integrative literature review was performed, and the recommendations of this study are to only perform endotracheal suctioning in newborns when there are signs of tracheal secretions and to avoid routinely performing the procedure. In addition, endotracheal suctioning should be conducted by at least two people, the suctioning time should be less than 15 seconds, the negative suction pressure should be below 100 mmHg, and hyperoxygenation should not be used on a routine basis. If indicated, oxygenation is recommended with an inspired oxygen fraction value that is 10 to 20% greater than the value of the previous fraction, and it should be performed 30 to 60 seconds before, during and 1 minute after the procedure. Saline instillation should not be performed routinely, and the standards for invasive procedures must be respected.

Keywords: Suction/methods; Respiration; artificial; Infant, newborn

INTRODUCTION

Evidence-based practices encourage the use of research results in clinical practice, and they are based on the search for the best available scientific evidence to support problem solving and decision making. Because of the quantity and complexity of information related to health care, the available evidence must be integrated through the performance of literature reviews. An integrative literature review represents a research method that is used in evidence-based practice because it allows for the incorporation of evidence into clinical practice. This method aims to gather and synthesize research findings on a defined topic or issue in a systematic and orderly manner to contribute to the deepening of knowledge on the studied subject. Although endotracheal suctioning in intubated newborns undergoing mechanical ventilation (MV) is the most invasive procedure performed in neonatal intensive care units (NICU)(1-13) in Brazil, this procedure is not grounded in the best scientific evidence available.

Newborns in the NICU routinely require MV, which may be non-invasive through an interface connecting the individual to the ventilator or invasive (the most common choice in NICUs) through an inserted endotracheal tube (ETT) connecting the individual to the ventilator.(1-6) The presence of the ETT leads to increased mucus production as a result of mild irritation generated in the airway mucosa, and it also impairs the ability to mobilize and expectorate secretions by suppressing the appropriate mucociliary mechanism and impairing the cough reflex, thus requiring frequent endotracheal suctioning to prevent secretion accumulation and airway obstruction.(4) In newborns, ETT have small internal diameters, which increases the difficulty of the procedure and increases the risk of complications.(2-4) ETT suctioning with internal diameters ≤ 4mm can cause an immediate reduction in dynamic pulmonary compliance and reduce the expired tidal volume (TV), regardless of lung pathology.(4) Moreover, inefficient suctioning can result in the obstruction of the ETT, the need for re-intubation and atelectasis, and a reduction in ventilation and oxygenation.(2)

Endotracheal suctioning is a manual mechanical technique for the removal of secretions from individuals who cannot properly remove pulmonary, tracheobronchial and/or oropharyngeal secretions. This procedure is routinely used in patients who require artificial airways and MV,(1-6) and it consists of introducing a sterile flexible tube through the airway and applying sub-atmospheric pressure at the time of its removal to suck out the secretions.(1-19) Despite the clinical importance of this technique, few methodologically sound Brazilian studies have been performed on this subject, and there is a lack of national consensus and clinical standardization regarding various points of the technique. Certain Brazilian services perform endotracheal suctioning in newborns according to criteria based on institutional routines or even the professional’s individual practice, which increases the chance of complications.

Therefore, the purpose of this study was to review secondary studies on the subject of endotracheal suctioning to establish recommendations for intubated newborns and encourage the adoption of best-practice concepts when conducting this procedure and the incorporation of scientific evidence into clinical practice.

METHODS

This paper presents an integrative review of secondary studies (guidelines and systematic reviews, with or without meta-analysis) published in English between 2000 and 2013. The goal was evaluate the open system endotracheal suctioning technique in human newborns undergoing invasive MV. The Cochrane, PEDro and PubMed databases were searched using the keywords “infant” and “newborn” and the following related terms identified in the Medical Subject Headings (MESH) database: “infants,” “newborn infant,” “newborn infants,” “newborns,” and “neonate.” In addition, these terms were combined with the intervention “suction” and the specific correlates identified in MESH: “suctions,” “aspiration,” “mechanical,” “aspirations,” “mechanical aspiration,” “mechanical aspirations,” “drainage,” “drainages,” “suction drainage,” and “suction drainages.” The searches of the Cochrane and PubMed databases were performed combining terms using the Boolean operators “AND” and “OR.” The PEDro database did not allow the use of both Boolean operators at the same time; therefore, this database was searched by an individual combination of terms and their correlates.

The selection of articles was based on the combination of patient-infant or -newborn and intervention-suction for newborns undergoing invasive MV, and the following clinical issues were addressed: frequency, duration, probe diameter, hyperoxygenation, negative suction pressure, saline instillation, number of repetitions, extraction time, absolute contraindications and biosecurity standards. Articles that explicitly defined the evidence level of each analyzed parameter were retained according to the evidence level and recommendation grade proposed by the Cardiology Commission (Comissão de Cardiologia); these grades are based on evidence from the Brazilian Society of Cardiology (Sociedade Brasileira de Cardiologia) and Brazilian Medical Association (Associação Médica Brasileira).

RESULTS

The search resulted in 93 publications (57 from Cochrane, 19 from PEDro and 17 from PubMed), which were analyzed according to the desired criteria. Of these, 89 articles were excluded for not addressing endotracheal suctioning in newborns or because they were not systematic reviews with or without meta-analyses or guidelines. Of the included studies, one was available on both the PEDro and PubMed databases (duplicate). Thus, four articles (four guidelines) remained, and they were included and analyzed in this integrative review as shown in table 1. The proposed results and the evidence level of each study are shown in table 2. Studies that were not consistent with the established search criteria, such as studies in Portuguese, but that were relevant to the subject under discussion were analyzed and used as a basis for discussion; however, they did not contribute to this study’s recommendations.

Table 1.

Relevant aspects of the evaluated articles

Title, year of publication and source Nasotracheal Suctioning - 2004 Revision & Update, 2004, Respiratory Care(10) ERNBG Guideline - Suction February 2006. Review: February 2006 Eastern Regional Neonatal Benchmarking Group Suctioning Guideline(9) Evidence-based guideline for suctioning the intubated neonate and infant, 2009, Neonatal Network(2) Endotracheal suctioning of mechanically ventilated patients with artificial airways, 2010, Respiratory Care( 6)
Hyperoxygenation before, during and after the procedure Not stated Pre-oxygenation should not be performed unless SpO2 has dropped Data regarding hyperoxygenation in NB are limited. Therefore, care must be taken when using oxygenation on this population Pre-oxygenation is suggested if the patient presents a clinically relevant reduction in SpO2 with suctioning
Evidence level 2B
In NB a 10% increase in FiO2 is recommended before suctioning, especially in hypoxemic NB
Hyperoxygenation should be maintained for at least 1 minute after suctioning, especially in hypoxemic patients
Characteristics of the suctioning probe The probe should be sterile, flexible, with various lateral orifices and one frontal one The probe must be measured prior to the procedure to ensure that the probe does not overshoot the end of the ETT The diameter of the probe should be less than 50% of the ETT diameter The probe diameter should not occlude more than 70% of the light in the ETT in small children
Evidence level V Evidence level 2C
The diameter of the probe should not exceed 50% of the internal diameter of the ETT Probes bigger than 6 F should not be used for suctioning in a 2.5 ETT
Evidence level V
Suctioning time Must be limited to 15 sees. Must be limited to 10 - 15 secs. Must be limited to 15 secs. Must be limited to 15 secs.
Evidence level V Evidence level 2C
Negative suction pressure 60 - 80 mmHg 50 - 100mmHg Must not exceed 100 mmHg 80 - 100mmHg.
Evidence level V
Suctioning should be applied only when removing the probe
Evidence level 3
Saline instillation Not stated Use limited to NB whose secretions may obstruct airways Should not be performed routinely Should not be performed routinely
Evidence level IV Evidence level 2C
Number of repetitions There is controversy regarding the excessive use of this procedure Normally, one or two attempts are sufficient for cleaning secretions Should not exceed three repetitions when suctioning Not stated
Suctioning time When clinically indicated When the need for the procedure is identified When the need for the procedure is identified Only when there is secretion and not routinely
Evidence level I Evidence level 1C
Absolute contraindication Not stated for intubated NB Not stated Not stated There is no absolute contraindication
Biosafety standards CDC guidelines for standard precautions should be respected Not stated Not stated CDC guidelines for standard precautions should be respected

SpO2 - peripheral capillary oxygen saturation; FiO2 - inspired oxygenation fraction; NB - Newborn; ETT - endotracheal tube; CDC - Center for Disease Control and Prevention.

Table 2.

Recommendations for endotracheal suctioning in intubated newborns

Clinical issue Recommendation Articles in agreement (%) Evidence level
Hyperoxygenation Hyperoxygenation should not be incorporated into the suctioning routine. If there is a drop in SpO2 with suctioning, hyperoxygenation should be established by increasing the FIO2 value 10 to 20% above that prior to suctioning 30 to 60 seconds before, during and 1 minute after the procedure 50 2B
Suctioning probe diameter Probe diameter must not exceed 50% of ETT diameter 50 2C
Suctioning duration Must not exceed 15 seconds 100 2C
Negative suction pressure Must be between 50 and 100mmHg 75 3C
Saline instillation Must not be performed routinely 75 2C
Number of repetitions Must not exceed 3 repetitions. The NB should be connected to the ventilator between suctions 25 -
Suctioning time Suctioning must not be performed routinely and should only be performed where clinically indicated. Clinical indications primarily include lung auscultation (coughing, coarse or reduced breathing) or visible secretions in the ETT, audible secretions, drop in SpO2 decreased chest excursion, changes in blood gas values, changes in respiratory rate and/or breathing pattern, bradycardia/tachycardia and/or agitation without other cause, and increased peak pressure on the ventilator 100 1C
Biosafety standards CDC guidelines should be respected, including the following: protection of the professional's eye, nose and mouth protection with the use of face mask and goggles, use of apron and sterile gloves, and performance of hand hygiene before and after performing the procedure. To increase safety, the procedure must be performed by at least two people 50 -
Monitoring The following variables should be monitored before, during and after the procedure: SpO2 skin coloring, respiratory frequency; respiratory pattern; hemodynamic variables (if monitored), such as heart rate, blood pressure, heart rhythm and ICP; suctioned secretion characteristics, such as color, volume, consistency and odor; cough characteristics; ventilatory parameters, such as peak inspiratory pressure and plateau pressure; current volume; flow; exhaled volume; and FiO2 100 -

SpO2 - peripheral capillary oxygen saturation; FiO2 - inspired oxygenation fraction; NB - newborn; ETT - endotracheal tube; CDC - Center for Disease Control and Prevention; ICP - intracranial pressure.

DISCUSSION

Endotracheal suctioning in intubated newborns undergoing MV is a procedure that is routinely performed by physiotherapists, doctors, nurses, and also by nursing technicians in Brazil as a component of the resuscitation procedure and bronchial hygiene therapy.(1-20) The goal is to maintain airway patency and facilitate ventilation and oxygenation.(1-6) However, this technique has specific indications and adverse effects. Proper standardization, clear indications for use and definitions of the procedure all serve to minimize complications.

Endotracheal suctioning is an important element of care for newborns admitted to the NICU because most of these patients require invasive MV and repeated and frequent suctioning for the removal of tracheal secretions.(2,4,8,9,12,20-29) According to the American Association of Respiratory Care (AARC), proper suctioning in intubated individuals improves gas exchange and respiratory sounds; decreases airway resistance and peak inspiratory pressure of the ventilator; improves dynamic compliance; increases the TV release when in limited pressure ventilation mode; and improves arterial blood gas and oxygen saturation (SpO2) values.(6,10) However, many institutions attempt to maintain airway patency in intubated individuals by adopting protocols that include the routine use of endotracheal suctioning without evaluating whether the procedure is necessary. These protocols are primarily based on the care ritual than on evidence of the clinical need for suctioning.

All of the studies included in this review described the technique as mandatory, i.e., that it should be performed whenever necessary because the accumulation of tracheobronchial secretions may impair ventilation and oxygenation; lead to ETT occlusion, atelectasis and increased respiratory work; and predispose the individual to pulmonary infection.(2,3,6,8-10,15-28) However, one of the most controversial issues regarding endotracheal suctioning in neonates is the precise time and frequency at which the technique should be performed on intubated individuals.

The results of this review reveal strong evidence that neonatal endotracheal suctioning should not be routinely performed and should only be undertaken when indicated, which occurs when there are signs of secretion.(2,6,9,10) The endotracheal suction procedure is not considered benign, although peripheral secretions are not removed with this single procedure.(8) Thus, it is important to perform individual evaluations of patients to determine whether suctioning should be performed. The following clinical criteria were considered for suctioning in intubated newborns: visible secretions in the ETT, audible secretions, coarse or decreased breathing sounds, decreased respiratory excursion, change in blood gases, changes in respiratory rate, bradycardia/tachycardia and/or agitation without other cause, increase in peak respiratory pressure and reduction in TV. The need for endotracheal suctioning in newborns is preferably evaluated using auscultation.(1,5,8,9) Therefore, the recommendation of this study is that the decision to perform endotracheal suctioning in newborns should be based on individual evaluations and clinical criteria identifications that indicate the need for suctioning and performing endotracheal suctioning should not be established as part of the routine care of intubated newborns.

There were no absolute contraindications for endotracheal suctioning in newborns, which was most likely because of the mandatory nature of the procedure. Most of the articles did not address this issue and only one study indicated the lack of absolute contraindications for endotracheal suctioning in newborns.(7) In clinical practice, endotracheal suctioning is avoided in newborns 15 to 30 minutes after surfactant administration.(28) In special cases, such as uncontrolled intracranial hypertension, additional measures to control intracranial pressure (ICP) must be adopted prior to endotracheal suctioning in newborns.

The decision regarding the exact time to perform endotracheal suctioning is important because this procedure is not without complications and adverse effects. Several adverse effects of endotracheal suctioning in newborns have been identified, such as hypoxemia, bradycardia, hypotension and reduced SpO2.(19-23) These effects have been related to the suctioning of air from the airways and vagal stimulation because of the introduction of the probe and the negative pressure generated in the airway.(4) Complications most commonly reported include trauma, bleeding, mucosal injury, atelectasis because of excessive suctioning of air from the airways, hypertensive peaks as a result of the reflex discharge of the sympathetic nervous system and bronchospasm.(7) The most serious complications are hypoxemia, increased blood pressure, increased ICP and pneumothorax.(8) Evidence has shown that these adverse effects can be minimized or eliminated by proper performance of the technique.(2)

Hypoxemia is the complication most often related to endotracheal suctioning in newborns; thus, hyperoxygenation is an important clinical issue. Hyperoxygenation occurs when the inspired oxygen fraction (FiO2) is administered at a higher percentage than what was delivered prior to suctioning at values reaching up to 100%.(2) Although hyperoxygenation is widely used in clinical practice to avoid hypoxemia, half of the authors examined in this review suggest that hyperoxygenation should not be conducted routinely but rather when the newborn has a clinically relevant reduction in SpO2 during suctioning.(6,9) This recommendation was based on the adverse effects caused by excess oxygen, even when applied for short periods of time, in newborns, such as hypercapnia, atelectasis by absorption, retinopathy of prematurity, alveolar and tracheobronchial changes, lung parenchyma, and especially oxidative stress, which leads to inflammatory responses, particularly in preterm newborns that do not have fully functioning antioxidant mechanisms.(9,17) Although there was a lack of consensus regarding hyperoxygenation in newborns, most of the studies in favor of this procedure agreed that the FiO2 rate should remain between 10 - 20% above the level prior to endotracheal suctioning.(15,16) To prevent hypoxemia in newborns, an increase of 20% in FiO2 relative to that prior to suctioning is likely as effective as hyperoxygenation with 100% FiO2.(14-16) Studies have even suggested that for most newborns, it is only necessary to increase the FiO2 value by 10% relative to the pre-suctioning value.(20-22)

With regard to whether FiO2 should be increased before or after endotracheal suctioning, there was no consensus and not all of the studies reported this variable. In one study, the recommendation was to increase FiO2 30 to 60 seconds before suctioning and 1 minute thereafter.(6) Therefore, the suggestion of this review is that if the newborn’s SpO2 falls during endotracheal suctioning, hyperoxygenation at an FiO2 value 10 - 20% higher than that prior to suctioning should be performed during the next suctioning and 30 to 60 seconds before the procedure, and this fraction should be maintained during suctioning and 1 minute thereafter. However, SpO2 must be monitored in all newborns requiring endotracheal suctioning; therefore, individualized hyperoxygenation parameters should be adopted according to clinical alterations during the procedure.(8,20-22)

Another potential complication of hyperoxia in newborns is the flip-flop phenomenon, which refers to a larger than expected drop in partial pressure arterial oxygen (PaO2) when FiO2 values are reduced to levels prior to endotracheal suctioning. This complication most likely occurs because of the reflex pulmonary vasoconstriction phenomenon. The pulmonary capillaries are sensitive to changes in PaO2 and changes in regional relations that increase the right-left shunt, which causes a disproportionate drop in PaO2 with reductions in FiO2.(19,24) Therefore, according to the Guide to Newborn Health Care (Atenção à Saúde do Recém-Nascido) of the Ministry of Health (Ministério da Saúde), if the FiO2 values are above 60%, the reduction in FiO2 should be 10% every 15 to 30 minutes to avoid the flip-flop effect.(24)

The procedure duration was correlated with the severity of adverse effects, and longer suctioning time produced a greater risk of damage to the tracheal mucosa and hypoxemia.(8,13-17) The analyzed studies all concluded that the duration of each suction event should not exceed 15 seconds.(2,6,9,10) However, there was a lack of consensus among the analyzed articles regarding the number of repetitions of endotracheal suctioning in newborns. According to Evidence-based guideline for suctioning the neonate and intubated infant, the probe size and negative pressure amount influenced the required number of repetitions.(2) In addition, an increased number of probe insertions during endotracheal suctioning increased the likelihood of complications, such as mucosal trauma, hypoxemia, laryngeal spasm, bronchospasm, necrotizing tracheitis, infection and discomfort, and it also increased the likelihood of barotrauma.(2,9) Therefore, we suggest that the probe insertion frequency should not exceed three repetitions and recommend that an appropriate amount of time should be allowed between suctioning events so that the monitored variables can return to baseline levels. In addition, the newborn should be reconnected to the ventilator at this time.(2,8,9,10) All of the studies concluded that hyperinsufflation, or ventilation with TV higher than that established on the MV, is not recommended in newborns because hyperinsufflation may provoke changes in FiO2 that would require the newborn to be reconnected to the respirator.(8) Therefore, the recommendation of this study is to perform the procedure is performed until improvements are observed in lung auscultation or the clinical parameters that led to suctioning. In addition, the procedure should be performed as efficiently as possible so that fewer repetitions are necessary, and a maximum of three repetitions are recommended for endotracheal suctioning in newborns.

According to the AARC and Evidence-based guideline for suctioning the intubated neonate and infant, the procedure is safer when certain variables are monitored before, during and after it is performed. These variables include respiratory sounds; SpO2; skin coloring; respiratory rate; breathing pattern; hemodynamic variables (if monitored), such as heart rate, blood pressure, heart rhythm and ICP; aspirated secretion characteristics, such as color, volume, consistency and odor; cough characteristics; ventilatory parameters, such as peak inspiratory pressure and plateau pressure; TV; flow; exhaled volume; and FiO2.(2,10) One study mentioned that to reduce changes in cerebral blood flow, the head of the newborn should be positioned to align with the midline.(9) Therefore, the recommendation of this study is to monitor these clinical variables before, during and after the procedure.

Half of the analyzed studies concluded that the diameter of the suctioning probe should not exceed 50% of the diameter of the ETT and recommended using the smallest suction probe capable of properly removing secretions. This recommendation is based on the fact that the suction probe size most likely has an increased influence on lung volume loss relative to negative suction pressure.(6,8,10) The larger the size of the suction probe and more negative the suction pressure, the greater the suctioned gas flow and the more negative the tracheal pressure during ETT suctioning. Thus, for a given diameter of ETT, the suction pressure level transmitted to the airway is determined by a combination of suction tube size and suction pressure.(6,8,10)

Negative suction pressure can damage the tracheobronchial mucosa by invagination caused by the probe orifice, which may rupture the capillaries.(13) The evaluated studies recommended that suction pressure should be checked by occluding the end of the suction probe before starting the procedure and ensuring that the suction pressure is as low as possible while still being able to remove secretions because negative tracheal pressure during suction is directly proportional to the applied pressure.(4) Negative pressures of 200mmHg with continuous and intermittent suctioning are capable of damaging the mucosa.(4,9,13) All of the articles analyzed in this study suggested that negative suction pressure in newborns should not exceed 100mmHg.(2,6,9,10) One study suggested subatmospheric pressures under 80mmHg. Therefore, the recommendation of this review is to apply suction pressure between - 50 to -100mmHg (8 - 10kPa) and avoid exceeding 100mmHg negative.

Saline instillation during endotracheal suctioning is a controversial topic in pediatrics, especially in neonatology. This practice is widely used in Brazilian ICU and corresponds to the instillation of saline aliquots (typically between 1 and 5ml) in the ETT before or during insertion of the suctioning probe. This procedure is based on the premise that saline facilitates the mobilization, release and removal of secretions and suctioning tubes lubricated with saline will reduce friction with the ETT and prevent triggering of the cough reflex.(6) However, saline instillation increases the likelihood of cardiac arrhythmia, hypoxemia, atelectasis, bronchospasm, infection, mucosal and respiratory tract cilia trauma and increases ICP.(2) In Ridling et al.’s study, saline instillation had an adverse effect on the reduction of SpO2 in the first and second minute after suctioning; however, the adverse effects were absent 10 minutes after the procedure.(27) According to Walsh et al., insertion of the suctioning tube can dislodge thousands of bacteria, and a saline jet may increase the risk of distributing these bacteria to the lungs, thus increasing the incidence of MV-associated pneumonia.(15) Consensus was observed in most of the analyzed articles that saline instillation should not be performed routinely.(6,8,10) Therefore, the recommendation of this study is to avoid the routine performance of saline instillation except in special situations, such as in the case of thick secretions and “secretion plugs” that would be impossible to remove without such a procedure.

Consensus was observed in half of the analyzed studies that the Center for Disease Control and Prevention (CDC) guidelines for standard precautions in invasive procedures must be respected to reduce instances of pneumonia associated with the procedure.(6,10) The remaining analyzed studies did not address this issue. In addition, certain studies argued that endotracheal suction is a procedure that should be performed by two people, thereby increasing safety of the procedure.(6,8,10) On the National Health Surveillance Agency’s (Agência Nacional de Vigilância Sanitária - ANVISA) website, references were not found regarding the biosafety standards for endotracheal suctioning or for invasive procedures. Therefore, with regard to the bio-security standards for the performance of endotracheal suctioning in intubated newborns, the recommendation of this review is to follow the CDC guidelines, which advocate protecting the professional’s eyes, nose and mouth using a face mask and goggles, wearing an apron and sterile gloves, and performing hand hygiene before and after the procedure.(29) An eye protector may also be placed on the newborn to prevent mucosa contamination. A further recommendation is for the procedure to be performed by at least two people.(8,9)

The implementation of guidelines based on scientific evidence can reduce the risks associated with endotracheal suctioning in newborns. These risks include physiological changes, pneumonia, tracheal damage, hyperoxygenation- and hypoxia-related changes, stress and discomfort. Although international guidelines are available, Brazilian recommendations are lacking, and the procedures adopted in Brazilian NICUs may differ from foreign procedures because of various differences in equipment, sociodemographic parameters, dispensed care, etc. Thus, recommendations and guidelines for this procedure in Brazil can contribute to improving the outcome of newborns in Brazilian NICUs.

Methodologically sound Brazilian endotracheal suctioning studies are scarce, especially in neonatology; therefore, generalizing the available data is difficult. The main limitations of this study were the small number of included articles, poor methodological descriptions and the absence of national secondary studies that address this issue. Additional studies are needed to increase the safety of the procedure and ground the technique in more consistent scientific evidence.

RECOMMENDATIONS

Based on the analyzed studies, the recommendation of this integrative review is to only perform endotracheal suctioning in intubated newborns when there are clinical signs of tracheal secretions, which are primarily evaluated by the presence of snoring or decreased breathing sounds on auscultation. This procedure should not be routinely performed to prevent airway obstruction. The suction time should not exceed 15 seconds, and the negative pressure must not exceed 100mmHg. Hyperoxygenation should not be used routinely and is only indicated when the baby has a clinically significant reduction in peripheral oxygen saturation during suctioning. When required to reduce hypoxemia, pre-oxygenation is recommended 30 to 60 seconds before, during and 1 minute after endotracheal suctioning by applying an inspired oxygen fraction that is 10 to 20% higher than what was used in the previous procedure. Saline instillation should not be routinely performed. Moreover, the Center for Disease Control and Prevention standards for invasive procedures must be respected during the procedure, the procedure must be conducted by at least two professionals, a maximum of three probe insertions should be performed, with a return to the ventilator between suctionings.

Footnotes

Conflicts of interest: None.

Editor responsável: Ruth Guinsburg

REFERENCES

  • 1.De Paula LC, Ceccon ME. Análise comparativa randomizada entre dois tipos de sistema de aspiração traqueal em recém-nascidos. Rev Assoc Med Bras. 2010;56(4):434–439. doi: 10.1590/s0104-42302010000400016. [DOI] [PubMed] [Google Scholar]
  • 2.Gardner DL, Shirland L. Evidence-based guideline for suctioning the intubated neonate and infant. Neonatal Netw. 2009;28(5):281–302. doi: 10.1891/0730-0832.28.5.281. Review. [DOI] [PubMed] [Google Scholar]
  • 3.Gillies D, Spence K. Deep versus shallow suction of endotracheal tubes in ventilated neonates and young infants. Cochrane Database Syst Rev. 2011;7 doi: 10.1002/14651858.CD003309.pub2. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 4.Kiraly NJ, Tingay DG, Mills JF, Morley CJ, Copnell B. Negative tracheal pressure during neonatal endotracheal suction. Pediatr Res. 2008;64(1):29–33. doi: 10.1203/PDR.0b013e31817289dc. [DOI] [PubMed] [Google Scholar]
  • 5.Celik SS, Elbas NO. The standard of suction for patients undergoing endotracheal intubation. Intensive Crit Care Nurs. 2000;16(3):191–198. doi: 10.1054/iccn.2000.1487. [DOI] [PubMed] [Google Scholar]
  • 6.American Association for Respiratory Care AARC Clinical Practice Guidelines Endotracheal suctioning of mechanically ventilated patients with artificial airways 2010. Respir Care. 2010;55(6):758–764. [PubMed] [Google Scholar]
  • 7.Rosa FK, Roese CA, Savi A, Dias AS, Monteiro MB. Comportamento da mecânica pulmonar após a aplicação de protocolo de fisioterapia respiratória e aspiração traqueal em pacientes com ventilação mecânica invasiva. Rev Bras Ter Intensiva. 2007;19(2):170–175. [PubMed] [Google Scholar]
  • 8.Pedersen CM, Rosendahl-Nielsen M, Hjermind J, Egerod I. Endotracheal suctioning of the adult intubated patient--what is the evidence? Intensive Crit Care Nurs. 2009;25(1):21–30. doi: 10.1016/j.iccn.2008.05.004. [DOI] [PubMed] [Google Scholar]
  • 9.ERNBG Guideline Suction February 2006 Review due: February 200 6 Eastern Regional Neonatal Benchmarking Group Suctioning Guideline. [2013 Nov 27]. Available http://guideline1.com/e/endotrachealsuctioning-guidelines-s83/
  • 10.AARC Clinical Practice Guidelines Nasotracheal Suctioning-2004 Revision & Update. Respir Care. 2004;49(9):1080–1084. [Google Scholar]
  • 11.Odell A, Allder A, Bayne R, Everett C, Scott S, Still B, et al. Endotracheal suction for adult, non-head- injured, patients. A review of the literature. Intensive Crit Care Nurs. 1993;9(4):274–278. doi: 10.1016/s0964-3397(05)80011-4. [DOI] [PubMed] [Google Scholar]
  • 12.Cone S, Pickler RH, Grap MJ, McGrath J, Wiley PM. Endotracheal suctioning in preterm infants using four-handed versus routine care. J Obstet Gynecol Neonatal Nurs. 2013;42(1):92–104. doi: 10.1111/1552-6909.12004. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 13.Wood CJ. Endotracheal suctioning: a literature review. Intensive Crit Care Nurs. 1998;14(3):124–136. doi: 10.1016/s0964-3397(98)80375-3. [DOI] [PubMed] [Google Scholar]
  • 14.Czarnik RE, Stone KS, Everhart CC, Jr, Preusser BA. Differential effects of continuous versus intermittent suction on tracheal tissue. Heart Lung. 1991;20(2):144–151. [PubMed] [Google Scholar]
  • 15.Walsh BK, Hood K, Merritt G. Pediatric airway maintenance and clearance in the acute care setting: how to stay out of trouble. Respir Care. 2011;56(9):1424-40;. doi: 10.4187/respcare.01323. discussion 1440-4. [DOI] [PubMed] [Google Scholar]
  • 16.Lookinland S, Appel PL. Hemodynamic and oxygen transport changes following endotracheal suctioning in trauma patients. Nurs Res. 1991;40(3):133–139. [PubMed] [Google Scholar]
  • 17.Diniz GC, Souza AO, Oliveira HM, Arrais RC, Pessoa BP, Figueiredo PH. A utilização de FiO2 inferior a 100% para hiperoxigenação de pacientes estáveis submetidos à aspiração endotraqueal. ASSOBRAFIR Ciênc. 2012;3(1):45–56. [Google Scholar]
  • 18.Johnston C, Zanetti NM, Comaru T, Ribeiro SN, Andrade LB, Santos SL. I Recomendação brasileira de fisioterapia respiratória em unidade de terapia intensiva pediátrica e neonatal. Rev Bras Ter Intensiva. 2012;24(2):119–129. [PubMed] [Google Scholar]
  • 19.Betit P, Thompson J. Wilkins RL, Stoller JK, Kacmarek RM. Egan . Rio de Janeiro: Elsevier; 2009. Terapia respiratória neonatal e pediátrica; pp. p. 1194–p. 1194. [Google Scholar]
  • 20.Pritchard M, Flenady V, Woodgate P. Preoxygenation for tracheal suctioning in intubated, ventilated newborn infants. Cochrane Database Syst Rev. 2001;(3):CD000427–CD000427. doi: 10.1002/14651858.CD000427. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 21.González-Cabello H, Furuya ME, Vargas MH, Tudón H, Gardunó J, Gonzáles- Ayala J. Evaluation of antihypoxemic maneuvers before tracheal aspiration in mechanically ventilated newborns. Pediatr Pulmonol. 2005;39(1):46–50. doi: 10.1002/ppul.20130. [DOI] [PubMed] [Google Scholar]
  • 22.Pritchard MA, Flenady V, Woodgate P. Systematic review of the role of pre-oxygenation for tracheal suctioning in ventilated newborn infants. J Paediatr Child Health. 2003;39(3):163–165. doi: 10.1046/j.1440-1754.2003.00123.x. [DOI] [PubMed] [Google Scholar]
  • 23.Hodge D. Endotracheal suctioning and the infant: a nursing care protocol to decrease complications. Neonatal Netw. 1991;9(5):7–15. [PubMed] [Google Scholar]
  • 24.Brasil. Ministério da Saúde. Secretaria de Atenção à Saúde. Departamento de Ações Programáticas Estratégicas. Atenção à saúde do recém-nascido: guia para os profissionais de saúde. 2a ed. Brasília: Ministério da Saúde; 2012. [Google Scholar]
  • 25.Carroll P. Safe suctioning prn. RN. 1994;57(5):32–36. quiz 37. [PubMed] [Google Scholar]
  • 26.Dean B. Evidence-based suction management in accident and emergency: a vital component of airway care. Accid Emerg Nurs. 1997;5(2):92–98. doi: 10.1016/s0965-2302(97)90088-6. [DOI] [PubMed] [Google Scholar]
  • 27.Ridling DA, Martin LD, Bratton SL. Endotracheal suctioning with or without instillation of isotonic sodium chloride solution in critically ill children. Am J Crit Care. 2003;12(3):212–219. [PubMed] [Google Scholar]
  • 28.Rebello CM, Procianoy R, Freddi A, Araujo KJ, Queirós H, Filho, Mascaretti RS. I Consenso Brasileiro de Ventilação Mecânica em Pediatria e Neonatologia: uso do surfactante no recém-nascido. São Paulo: Associação de Medicina Intensiva Brasileira; 2012. http://www.sbp.com.br/pdfs/I_Consenso_Brasileiro_de_Surfactante.pdf Internet. [Google Scholar]
  • 29.Siegel JD, Rhinehart E, Jackson M, Chiarello L, Health Care Infection Control Practices Advisory Committee 2007 Guideline for Isolation Precautions: Preventing Transmission of Infectious Agents in Health Care Settings. Am J Infect Control. 2007;35(10) Suppl 2:S65–164. doi: 10.1016/j.ajic.2007.10.007. [DOI] [PMC free article] [PubMed] [Google Scholar]

Articles from Revista Brasileira de Terapia Intensiva are provided here courtesy of Associação de Medicina Intensiva Brasileira

RESOURCES