Despite there are some debates with catheter closure of the patent foramen ovale (PFO),1) it can be an option in reducing the risk of recurrent paradoxical embolism and incidence of migraines. Although it has been a safe and promising technique with a low incidence of periprocedural complication,2) some of complications during the procedure can be fatal. We found a linear, highly mobile lesion attached to the PFO closure device during the procedure. What did happen during the procedure?

A 48-year-old woman visited the emergency room with an acute onset of dysarthria. She was diagnosed with a cerebral infarction of the superior branch of the right middle cerebral artery. The patient had a history of transient ischemic attack about 4 years ago. At the time, her transesophageal echocardiography revealed the presence of about a 1 mm sized PFO with a significant right to left shunt through it after having the Valsalva maneuver performed. She discontinued her medication after one month and did not visit the out-patient clinic. Because of the recurrent embolic events, the attending neurologist and consultant cardiologist decided to occlude the PFO with the Amplatzer® PFO occlude device (AGA medical Co., Minneapolis, MN, USA).

The intervention was performed under local anesthesia with fluoroscopic guidance. After a venous puncture of the right femoral vein, the PFO was crossed under fluoroscopic guidance in the anteroposterior view by a standard length normal 0.035-inch guidewire. Initially, a J-tip was used to ensure passage through the hole. The interventionist tried to insert a 23-mm device through the J-tip. However, the procedure was not smooth and repeated attempts were performed. The device was finally inserted after several attempts. The follow-up echocardiography showed a freely moving linear mass lesion on the tip of the left atrial disc. The transesophageal echocardiography demonstrated about a 13 cm sized linear mass attached to the tip of the left atrial disk (Fig. 1, Supplementary movie 1). The highly mobile mass moved to-and-fro through the mitral valve. To reduce further catastrophic embolic events, the patient underwent open heart surgery to remove the device with the mass and occlude the PFO. We found with about a 20 cm sized linear fresh thrombus attached to the tip of the left atrial disc (Fig. 2). Fortunately, she was discharged without further complications after the surgery. Meticulous handling is necessary to prevent this injurious complication during procedure.

Fig. 1. Transesophageal echocardiographic examination shows about a 13 cm sized linear mass (arrowheads) attached on the tip of the Amplatzer® PFO occlude device (arrow).

Fig. 1

Fig. 2. After the open heart surgery, about 20 cm sized fresh thrombus (arrowheads) is attached on the removed device (arrow).

Fig. 2

Supplementary movie

Movie 1

The transesophageal echocardiography shows about a 13 cm sized linear mass lesion attached to the tip of left atrial disc and moves to-and-fro through the mitral valve.

Download video file (8.1MB, avi)

References

  • 1.Wolfrum M, Froehlich GM, Knapp G, Casaubon LK, DiNicolantonio JJ, Lansky AJ, Meier P. Stroke prevention by percutaneous closure of patent foramen ovale: a systematic review and meta-analysis. Heart. 2014;100:389–395. doi: 10.1136/heartjnl-2013-304394. [DOI] [PubMed] [Google Scholar]
  • 2.Bruch L, Parsi A, Grad MO, Rux S, Burmeister T, Krebs H, Kleber FX. Transcatheter closure of interatrial communications for secondary prevention of paradoxical embolism: single-center experience. Circulation. 2002;105:2845–2848. doi: 10.1161/01.cir.0000019069.32964.0e. [DOI] [PubMed] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Supplementary Materials

Movie 1

The transesophageal echocardiography shows about a 13 cm sized linear mass lesion attached to the tip of left atrial disc and moves to-and-fro through the mitral valve.

Download video file (8.1MB, avi)

Articles from Journal of Cardiovascular Ultrasound are provided here courtesy of BMC

RESOURCES