Skip to main content

Some NLM-NCBI services and products are experiencing heavy traffic, which may affect performance and availability. We apologize for the inconvenience and appreciate your patience. For assistance, please contact our Help Desk at info@ncbi.nlm.nih.gov.

Thorax logoLink to Thorax
. 1985 Apr;40(4):244–247. doi: 10.1136/thx.40.4.244

Contaminated humidifiers and the lung.

D J Hendrick
PMCID: PMC460040  PMID: 4023973

Full text

PDF
244

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Anderson K., McSharry C. P., Boyd G. Radiographic changes in humidifier fever. Thorax. 1985 Apr;40(4):312–313. doi: 10.1136/thx.40.4.312. [DOI] [PMC free article] [PubMed] [Google Scholar]
  2. Banaszak E. F., Thiede W. H., Fink J. N. Hypersensitivity pneumonitis due to contamination of an air conditioner. N Engl J Med. 1970 Aug 6;283(6):271–276. doi: 10.1056/NEJM197008062830601. [DOI] [PubMed] [Google Scholar]
  3. Cavagna G., Foà V., Vigliani E. C. Effects in man and rabbits of inhalation of cotton dust or extracts and purified endotoxins. Br J Ind Med. 1969 Oct;26(4):314–321. doi: 10.1136/oem.26.4.314. [DOI] [PMC free article] [PubMed] [Google Scholar]
  4. Chan-Yeung M., Lam S., Koener S. Clinical features and natural history of occupational asthma due to western red cedar (Thuja plicata). Am J Med. 1982 Mar;72(3):411–415. doi: 10.1016/0002-9343(82)90497-1. [DOI] [PubMed] [Google Scholar]
  5. DoPico G. A., Reddan W., Flaherty D., Tsiatis A., Peters M. E., Rao P., Rankin J. Respiratory abnormalities among grain handlers: a clinical, physiologic, and immunologic study. Am Rev Respir Dis. 1977 Jun;115(6):915–927. doi: 10.1164/arrd.1977.115.6.915. [DOI] [PubMed] [Google Scholar]
  6. Dosman J. A. Chronic obstructive pulmonary disease and smoking in grain workers. Ann Intern Med. 1977 Dec;87(6):784–786. doi: 10.7326/0003-4819-87-6-784. [DOI] [PubMed] [Google Scholar]
  7. Fergusson R. J., Milne L. J., Crompton G. K. Penicillium allergic alveolitis: faulty installation of central heating. Thorax. 1984 Apr;39(4):294–298. doi: 10.1136/thx.39.4.294. [DOI] [PMC free article] [PubMed] [Google Scholar]
  8. Friend J. A., Gaddie J., Palmer K. N., Pickering C. A., Pepys J. Extrinsic allergic alveolitis and contaminated cooling-water in a factory machine. Lancet. 1977 Feb 5;1(8006):297–300. doi: 10.1016/s0140-6736(77)91839-6. [DOI] [PubMed] [Google Scholar]
  9. Haglind P., Rylander R. Exposure to cotton dust in an experimental cardroom. Br J Ind Med. 1984 Aug;41(3):340–345. doi: 10.1136/oem.41.3.340. [DOI] [PMC free article] [PubMed] [Google Scholar]
  10. Hendrick D. J., Marshall R., Faux J. A., Krall J. M. Positive "alveolar" responses to antigen inhalation provocation tests: their validity and recognition. Thorax. 1980 Jun;35(6):415–427. doi: 10.1136/thx.35.6.415. [DOI] [PMC free article] [PubMed] [Google Scholar]
  11. Kumar P., Marier R., Leech S. H. Hypersensitivity pneumonia due to contamination of a car air conditioner. N Engl J Med. 1981 Dec 17;305(25):1531–1532. doi: 10.1056/NEJM198112173052515. [DOI] [PubMed] [Google Scholar]
  12. Morgan D. C., Smyth J. T., Lister R. W., Pethybridge R. J. Chest symptoms and farmer's lung: a community survey. Br J Ind Med. 1973 Jul;30(3):259–265. doi: 10.1136/oem.30.3.259. [DOI] [PMC free article] [PubMed] [Google Scholar]
  13. Morgan W. K., Vesterlund J., Burrell R., Gee J. B., Willoughby W. F. Byssinosis: some unanswered questions. Am Rev Respir Dis. 1982 Aug;126(2):354–357. doi: 10.1164/arrd.1982.126.2.354. [DOI] [PubMed] [Google Scholar]
  14. Muittari A., Kuusisto P., Virtanen P., Sovijärvi A., Grönroos P., Harmoinen A., Antila P., Kellomäki L. An epidemic of extrinsic allergic alveolitis caused by tap water. Clin Allergy. 1980 Jan;10(1):77–90. doi: 10.1111/j.1365-2222.1980.tb02083.x. [DOI] [PubMed] [Google Scholar]
  15. Pickering C. A., Moore W. K., Lacey J., Holford-Strevens V., Pepys J. Investigation of a respiratory disease associated with an air-conditioning system. Clin Allergy. 1976 Mar;6(2):109–118. doi: 10.1111/j.1365-2222.1976.tb01888.x. [DOI] [PubMed] [Google Scholar]
  16. Rylander R., Haglind P., Lundholm M., Mattsby I., Stenqvist K. Humidifier fever and endotoxin exposure. Clin Allergy. 1978 Sep;8(5):511–516. doi: 10.1111/j.1365-2222.1978.tb01504.x. [DOI] [PubMed] [Google Scholar]
  17. Rylander R., Lundholm M. Bacterial contamination of cotton and cotton dust and effects on the lung. Br J Ind Med. 1978 Aug;35(3):204–207. doi: 10.1136/oem.35.3.204. [DOI] [PMC free article] [PubMed] [Google Scholar]
  18. Warren C. P. Extrinsic allergic alveolitis: a disease commoner in non-smokers. Thorax. 1977 Oct;32(5):567–569. doi: 10.1136/thx.32.5.567. [DOI] [PMC free article] [PubMed] [Google Scholar]