Skip to main content
BMC Anesthesiology logoLink to BMC Anesthesiology
. 2015 Oct 15;15:148. doi: 10.1186/s12871-015-0131-8

Fluid management guided by a continuous non-invasive arterial pressure device is associated with decreased postoperative morbidity after total knee and hip replacement

Jan Benes 1,, Lenka Haidingerova 1, Jiri Pouska 1, Jan Stepanik 1, Alena Stenglova 1, Jan Zatloukal 1, Richard Pradl 1, Ivan Chytra 1, Eduard Kasal 1
PMCID: PMC4608292  PMID: 26471495

Abstract

Background

The use of goal directed fluid protocols in intermediate risk patients undergoing hip or knee replacement was studied in few trials using invasive monitoring. For this reason we have implemented two different fluid management protocols, both based on a novel totally non-invasive arterial pressure monitoring device and compared them to the standard (no-protocol) treatment applied before the transition in our academic institution.

Methods

Three treatment groups were compared in this prospective study: the observational (CONTROL, N = 40) group before adoption of fluid protocols and two randomized groups after the transition to protocol fluid management with the use of the continuous non-invasive blood pressure monitoring (CNAP®) device. In the PRESSURE group (N = 40) standard variables were used for restrictive fluid therapy. Goal directed fluid therapy using pulse pressure variation was used in the GDFT arm (N = 40). The influence on the rate of postoperative complications, on the hospital length of stay and other parameters was assessed.

Results

Both protocols were associated with decreased fluid administration and maintained hemodynamic stability. Reduced rate of postoperative infection and organ complications (22 (55 %) vs. 33 (83 %) patients; p = 0.016; relative risk 0.67 (0.49–0.91)) was observed in the GDFT group compared to CONTROL. Lower number of patients receiving transfusion (4 (10 %) in GDFT vs. 17 (43 %) in CONTROL; p = 0.005) might contribute to this observation. No significant differences were observed in other end-points.

Conclusion

In our study, the use of the fluid protocol based on pulse pressure variation assessed using continuous non-invasive arterial pressure measurement seems to be associated with a reduction in postoperative complications and transfusion needs as compared to standard no-protocol treatment.

Trial registration

ACTRN12612001014842

Electronic supplementary material

The online version of this article (doi:10.1186/s12871-015-0131-8) contains supplementary material, which is available to authorized users.

Keywords: Fluid management, Perioperative care, Goal directed therapy, Pulse pressure variation

Background

In recent years fluid management protocols and goal-directed therapy (GDT) have gained popularity among anesthesiologists [1]. According to recent meta-analyses GDT is associated with a decreased rate of postoperative complications [24] and fluid optimization protocols seem to be the necessary step [5]. A rational fluid optimization protocol consisting of maintenance infusion covering basal loss and goal-directed top-ups has been proposed by other authors [6, 7]. However, according to a recently published survey among European and American anesthesiologists [8], protocols for perioperative hemodynamic care are lacking in many institutions. Another important factor stressed by this survey was the use of dynamic variations of stroke volume or its surrogates as substitutes of cardiac output monitoring. In high-risk surgical populations, the studies by Forget [9] and Lopes [10] as well as one large meta-analysis of other published trials [11] showed a positive influence of the dynamic variations-led GDT even without monitoring of cardiac output. The adoption of dynamic variations is limited in some situations [12], but can significantly simplify the delivery of fluid optimization protocols.

Total hip or knee replacements are usually performed among elderly patients, but neither the chronic health state nor the procedure-associated risk usually exceed moderate risk. In one study, hemodynamic optimization using oxygen delivery targets was associated with favorable postoperative outcome [13]. However, such invasive monitoring might lead to some minor complications [14], increases the economic burden and is often deemed unnecessary. The volume clamp method for continuous non-invasive arterial pressure monitoring or similar techniques enables the delivery of a fluid therapy protocol without these disadvantages.

In this trial we studied the effect of a controlled transition from non-protocolled to protocolled fluid management on the rate of postoperative complications and other relevant perioperative outcomes in patients undergoing elective total hip and knee replacement. Our hypothesis was that the fluid management protocol guided by non-invasive continuous arterial pressure and the easily obtained dynamic predictor of fluid responsiveness (respiratory variation of the pulse pressure - PPV) would help to decrease postoperative morbidity.

Methods

The study was performed at the Department of Anesthesia and Intensive Care Medicine of the Faculty of Medicine and Charles University Hospital in Plzen. The Institutional review board approved the study which was consequently registered in the primary WHO register (ACTRN12612001014842), and all patients gave and signed the informed consent. The study was performed and reported in accordance with the CONSORT statement [15] (see Additional file 1). The trial followed a two-stage “before and after” design with one control observational group and two randomized-protocol based study groups. All groups consisted of two strata (total hip replacement - 20 patients and total knee replacement – 20 patients). Basic inclusion for all study participants were: age above 18, general anesthesia, regular heart rhythm, informed consent and no need for direct and continuous blood pressure monitoring or advanced hemodynamic monitoring.

First stage – observational and wash-out period

The CONTROL group was treated according to the usual care without any fluid protocol. On the day of surgery patients were fasted and received 2 ml/kg/h of crystalloid infusion from the morning until transport to the operation room. Throughout the surgery monitoring of blood pressure was performed using an automatic oscillometric non-invasive arm cuff (rate of measurement once every 5 min but there were no restrictions in increasing the rate). Blood pressure fluctuations within 20 % of the baseline values were tolerated. The amounts of fluids infused were at the discretion of the treating anesthesiologist. Transfusion of red blood cells was indicated when the hemoglobin fell below 90 g/l; in overall healthy patients lower thresholds (up to 70 g/l) were tolerated. The blood loss was assessed by measuring the balance of closed system suction. Two independent investigators (JZ and RP) were responsible for the assessment of the CONTROL group patients. These two investigators did not participate in the following course of the study so the outcome data was concealed.

After completion of the first phase a wash-out period was interposed. Within this time all study members responsible for in-study anesthesia delivery (LH, JP and JS) were trained in the use of the CNAP® monitor and the protocol (each of them had to perform at least 10 cases per protocol group).

Second stage – randomized, protocol based

During the second stage all patients undergoing scheduled total knee or hip replacement fulfilling mentioned inclusion criteria were found eligible. Patients were equally randomized into two groups (GDFT and PRESSURE) each with 40 patients, stratified to knee and hip replacement (20 patients each). Randomization was performed by the study member responsible for the anesthesia delivery before the induction using sealed opaque envelope technique stored in non-transparent containers (one per stratum) with group allocation in a 1:1 ratio. Each envelope, holding one patient’s identification, was then returned into another non-transparent container which remained sealed till the end of the study when the concealment was broken for statistical analysis. This made all other study members as well as the surgeon and other health care staff blinded to individual patient’s allocation.

Anesthesia, monitoring and protocol delivery

All patients were fasted before the procedure, small amounts of liquids were allowed for those later on the operating schedule and for chronic medication ingestion. During fasting all patients received an infusion of Hartmann solution (2 ml/kg/h) from the morning of the operative day. General anesthesia was induced using propofol (2 mg/kg) and sufentanil (0.2 μg/kg) and tracheal intubation was facilitated by atracurium or rocuronium (0.5 mg/kg). Volatile anesthetic (sevoflurane – MAC 0.8–1.2 accounted for age) in oxygen-N2O mixture was used for anesthesia maintenance. Opioid or muscle relaxant increments were used to secure adequate analgesia and operating conditions. Under relevant circumstances a deviation in the usual induction or maintenance was tolerated at the discretion of the treating anesthesiologist or anesthesia consultant.

The CNAP® device (CNSystems, Graz, Austria) was used for blood pressure monitoring in both protocol groups (GDFT and PRESSURE). The device works utilizes the principle of volume clamping described by the Czech physiologist Peňáz in 1963 and adapted later by Fortin [16]. First, a state of vascular unloading is set by inflating the cuff around the finger to reach maximal pulse oscillations (the pressure inside and outside the arterial wall is then equivalent). Next, the volume of blood compartment of the finger is measured by plethysmography and held constant with the use of fast reacting inflations/deflations of the cuff. This enables a reconstruction of the arterial pressure curve at the level of the fingers. To obtain brachial pressure, the values are calibrated at the beginning and every 15 min thereafter using a standard non-invasive oscillometric measurement in the arm. The device displays blood pressure continuously, enabling the automatic calculation of the PPV (pulse pressure variation) and exports the pressure curve and values to standard monitor (Ultraview SL2700, Spacelabs Healthcare, Washington, USA). In the GDFT group all relevant data was shown to the anesthesiologist. In the PRESSURE group the screen of the CNAP® device was covered and the continuous arterial pressure curve and values (without PPV) were transferred to the bedside anesthesia monitor. The values of the PPV for the analysis were obtained off-line from stored data after the procedure by a study member (JB) blinded to patient allocation.

Throughout the procedure fluid therapy was delivered according to the protocols displayed in Fig. 1a and b with maintenance infusion of 5 ml/kg/h of crystalloids (Plasmalyte, Baxter Czech s.r.o., Praha, Czech Republic). Repeated boluses of 3 ml/kg of colloids (preferentially Gelofusine 4 % or 130/0.4 HES 6 %, Volulyte; both B-Braun Melsungen, Germany) were used if indicated by usual pressure targets (PRESSURE group) or by pulse pressure variation above 13 % (GDFT group). In case of reaching the maximal dose of colloids (25 ml/kg) crystalloid boluses of 3 ml/kg would be used for further care. When the patient was hypotensive though reaching a “volume loaded state” (defined as PPV < 13 % or based on clinical assessment in the GDFT or PRESSURE groups respectively) a vasoactive rescue medication (Ephedrine 5–10 mg i.v. bolus or continuous Norepinephrine) was indicated. The decision which drug to choose was on the discretion of treating anesthesiologist based on presumed duration of hypotensive period and/or underlying cause. The number of hypotensive periods requiring volume loading and/or vasoactive treatment was collected as well as total dose of vasoactive medication. The same transfusion threshold (as the CONTROL group) was used if not required otherwise due to chronic conditions of the patient.

Fig. 1.

Fig. 1

The protocols of fluid management in the second-stage groups (PRESSURE – panel a; GDFT – panel b). Legend: HR – hear rate; MAP – mean arterial pressure; PPV – pulse pressure variation; IPPV – Volume controlled ventilation; Vt – Tidal volume; PEEP – Positive End-Expiratory Pressure; RR – respiratory rate

Study outcomes

The number of patients with any postoperative organ or infectious complication was the primary outcome measure of the study. The list of relevant complications was based on previous GDT trials [13, 17] (Additional file 2). The treating physician was responsible for the diagnosis and treatment of all complications. Hospital length of stay and all-cause mortality were assessed as secondary outcomes. Fluid balance and lactate levels in the early (24 h) postoperative period were regarded as safety measures. Besides the mentioned conditions, other potentially relevant outcomes (i.e. ICU length of stay, duration of ventilator support, number of blood products used, hemoglobin level and hemodynamic profile in the intraoperative and early postoperative period as well as vasoactive medication used) were assessed. As both the ICU and hospital lengths of stay might be influenced by many other factors not relevant to the health care conditions of the patient, a readiness for standard ward transfer and for hospital discharge were also evaluated (screening criteria are listed in the Additional file 2). Two investigators (JB, AS), blinded to study group allocation and not participating in the anesthesia care and randomization, evaluated the state of the patients during regular visits.

Statistical analysis

The number of CONTROL group patients was based on previous observations in similar patient population [13]. A significant reduction of postoperative complication (odds ratio 0.38) was reported in recent meta-analysis concerning hemodynamic optimization [2]. Due to inclusion of intermediate risk patients we had expected to observe lower treatment effect. According to the rate of complications observed in the CONTROL group (33 patients (83 %)) and to treatment effect expected (conservative reduction from 83 to 50 %) a sample of 36 patients would be necessary (alpha and beta error of 0.05 and 0.2). We have decided to include 40 patients into each group in order to cover possible “drop outs” and also to facilitate the division into two strata (total hip vs. knee replacement).

The analysis was performed using the SigmaStat for Windows v.3.5 (Systat Software Inc., San Jose, USA). The Kolmogorov-Smirnoff test was used for normality assessment. For inter-group comparison one-way ANOVA or Kruskall-Wallis tests were used respectively. For time-dependent variables, repeated measures ANOVA or Friedman tests were performed. Post-hoc analysis was performed with the Student-Newman-Keul’s or Dunn’s test. Categorical variables were tested using the Chi-square test. The p < 0.05 was taken as statistically significant.

Results

During the first stage (August and September 2012), 40 consecutive patients undergoing hip (20 patients) and knee (20 patients) replacements under general anesthesia were observed for peri- and postoperative outcomes (CONTROL group). All patients operated during this period were included and there were none lost to follow up. In the second stage (late November 2012 to early March 2013), a total of 97 hip or knee replacements were performed under general anesthesia and found eligible for study inclusion. Seventeen patients were excluded before randomization for various reasons (listed in Fig. 2), 80 patients were included and equally randomized into two groups each with two strata containing 20 patients. All patients in both stages gave informed consent and were included in the final analysis, one of them died within 30 postoperative days because of pulmonary embolization. The entire flow chart according to CONSORT statement is displayed in Fig. 2. No significant differences were observed between the three groups in regard to demographic parameters or chronic comorbidities (Table 1).

Fig. 2.

Fig. 2

The flow chart of patients through the trial. Legend: ITT – intention-to-treat analysis

Table 1.

Baseline and demographic characteristics

CONTROL PRESSURE GDFT P value
(N = 40) (N = 40) (N = 40)
Age (years) 70 (54–84) 66 (44–80) 68 (33–84) 0.145
Sex (F/M) 25/15 26 / 14 23/17 0.789
Height (cm) 167 (8) 166 (9) 169 (11) 0.385
Weight (kg) 82 (15) 82 (15) 90 (16) ab 0.025
ASA (1/2/3) 2/23/15 7/24/9 6/27/7 0.164
Arterial hypertension 30 (75 %) 28 (70 %) 27 (68 %) 0.754
Ischemic heart disease 9 (23 %) 7 (18 %) 4 (10 %) 0.320
Chronic pulmonary disease 6 (15 %) 4 (10 %) 4 (10 %) 0.724
Diabetes mellitus 9 (23 %) 6 (15 %) 10 (25 %) 0.519

Data are presented as mean and range for age, mean (standard deviation) or number (proportion) for other parameters

a - significant difference between PRESSURE vs. GDFT groups

b - significant difference between protocolled group (GDFT or PRESSURE) vs. CONTROL

The results of primary and secondary outcome data are summarized in Tables 2 and 3. The rate of complications among patients of the CONTROL group was higher as compared to both protocol groups. In pair-wise comparisons, only the difference between CONTROL and GDFT reached statistical significance (33 patients (83 %) vs. 22 (55 %); p = 0.02; relative risk 0.67 (95 % confidence interval 0.49–0.91)). The higher number of complications resulted in a trend towards the prolongation of hospital length of stay as assessed by readiness for discharge criterion.

Table 2.

Intervention data, fluid balance and laboratory outcome

CONTROL PRESSURE GDFT P-value
(N = 40) (N = 40) (N = 40)
Length of the procedure (min) 110 (100–120) 105 (90–118) 100 (85–113) 0.06
MAP before anesthesia (mmHg) 119 (15) 113 (17) 114 (19) 0.31
MAP end of procedure (mmHg) 118 (14) 105 (12)bc 103 (18)bc <0.001
HR before anesthesia (beats per minute) 73 (10) 72 (11) 68 (13) 0.20
HR end of procedure (beats per minute) 74 (14) 78 (16)c 77 (14)c 0.34
PPV after induction N/A 7.9 (4.2) % 8.9 (4.5) % 0.36
PPV end of procedure N/A 7.2 (2.4) % 8.2 (3.8) % 0.15
Hypotensive periods intraoperatively 3 (1–5) 2 (1–4) 2 (0–4) 0.09
Ephedrin (number of interventions) 2 (0–3) 0 (0–1)b 0 (0–1)b <0.001
Ephedrin (dose - mg) 10 (0–15) 0 (0–10) 0 (0–10) 0.11
Hemoglobin before anesthesia (g/l) 136 (11) 121 (12) ab 131 (14) <0.001
Hemoglobin end of procedure (g/l) 117 (15) 110 (13) ab 118 (16) 0.03
Lactate end of procedure (mmol/l) N/A 1.2 (0.4) 1.2 (0.6) 0.99
Intraoperative fluid balance
Blood loss (ml) 500 (300–575) 500 (300–600) 400 (300–600) 0.77
Maintenance fluids (crystalloid) (ml) 1500 (1200–1500) 700 (600–750)b 750 (600–900)b <0.001
Bolus fluids (colloid) (ml) 0 (0–500) 440 (100–500)b 400 (0–500)b 0.01
Patients receiving transfusion 5 (13 %) 3 (8 %) 1 (3 %) 0.24
Number of packed blood cells transfused 0 (0–0) 0 (0–0) 0 (0–0) 0.26
Early postoperative fluid balance (24 h)
Blood loss (ml) 735 (400–805) 470 (390–840) 500 (380–678) 0.42
Diuresis (ml) 1300 (1025–1625) 1000 (785–1378)b 1075 (900–1300)b 0.01
Crystalloids (ml) 2525 (2300–2800) 2800 (2300–3150) 2700 (2350–3125) 0.27
Colloids (ml) 0 (0–0) 0 (0–0) 0 (0–0) 0.70
Patients receiving transfusion 17 (43 %) 11 (28 %) 4 (10 %)b 0.01
Number of packed blood cells transfused 0 (0–2) 0 (0–2) 0 (0–0)b 0.01
Hemoglobin (24 h) (g/l) 105 (10) 102 (12) a 110 (14) a 0.01
Lactate (24 h) (mmol/l) N/A 1.6 (0.8) 1.7 (0.8) 0.67

Data are presented as mean (standard deviation), median (interquartil range) or number (proportion)

PPV pulse pressure variation, HR heart rate, MAP mean arterial pressure

a - significant difference between PRESSURE vs. GDFT groups

b - significant difference between protocolled group (GDFT or PRESSURE) vs. CONTROL

c - significant difference against baseline

Table 3.

Clinical outcome

CONTROL PRESSURE GDFT P-value
(N = 40) (N = 40) (N = 40)
Rate of complications (all) 33 (83 %) 26 (65 %) 22 (55 %)a 0.03
Rate of complications (major) 3 (8 %) 6 (15 %) 2 (5 %) 0.27
Mortality 0 (0 %) 1 (2.5 %) 0 (0 %) 0.37
Hospital length of stay (days) 10.5 (8–12) 10 (9–12.5) 10 (8.5–13.5) 0.99
Discharge readiness (days) 9 (8–12) 9 (7–12) 8 (7–10) 0.06
ICU length of stay (days) 2 (2–2) 2 (2–3) 2 (2–3) 0.3
ICU readiness (days) 2 (2–2) 2 (2–2) 2 (2–2) 0.38
Number of complications (all) 66 61 35 N/A
Number of complications (major) 3 8 3 N/A
Blood transfusion (patients) 30 (75 %) 25 (63 %) 15 (38 %)a 0.001
Blood transfusion (units) 2 (1–4) 2 (0–4) 0 (0–2) N/A
Complications per group (Number of patients)
Cardiovascular
 Minor 2 (5 %) 4 (10 %) 0 (0 %) 0.12
 Major 0 (0 %) 1 (2.5 %) 1 (2.5 %) 0.6
Respiratory
 Minor 1 (2.5 %) 1 (2.5 %) 0 (0 %) 0.6
 Major 0 (0 %) 1 (2.5 %) 0 (0 %) 0.37
Infectious
 Minor 23 (57.5 %) 9 (22.5 %)a 9 (22.5 %)a 0.001
 Major 2 (5 %) 3 (7.5 %) 2 (5 %) 0.86
Renal
 Minor 5 (12.5 %) 7 (17.5 %) 5 (12.5 %) 0.76
 Major 0 (0 %) 0 (0 %) 0 (0 %) 1
GIT
 Minor 20 (50 %) 17 (42.5 %) 11 (27.5 %) 0.12
 Major 0 (0 %) 0 (0 %) 0 (0 %) 1
Nervous
 Minor 1 (2.5 %) 3 (7.5 %) 3 (7.5 %) 0.55
 Major 0 (0 %) 0 (0 %) 0 (0 %) 1
Coagulation
 Minor 6 (15 %) 7 (17.5 %) 3 (7.5 %) 0.39
 Major 1 (2.5 %) 2 (5 %) 0 (0 %) 0.36

Data are presented as median (interquartil range) or number (proportion)

ICU intensive care unit, GIT gastro-intestinal tract

a - significant difference between protocolled group (GDFT or PRESSURE) vs. CONTROL

In both protocol groups a trend for lower number of hypotensive periods was observed intraoperatively with lower dose of rescue vasoactive therapy. No significant differences were found between PPV values of both protocol groups (PRESSURE and GDFT). Pulse pressure variation was low in both groups in the beginning as well as at the end of the procedure. The overall fluid status (amount of fluids administered, blood loss etc.) was comparable in both protocol groups. Contrarily, the CONTROL patients received significantly higher amounts of fluid compared to both groups managed with protocol. A drop in hemoglobin level was observed among all patients, but was more pronounced in the CONTROL group patients (Fig. 3). A higher proportion of CONTROL patients needed transfusion during early as well as late postoperative periods. Serum lactate levels were assessed only in the prospective groups’ patients and showed no significant differences between PRESSURE and GDFT.

Fig. 3.

Fig. 3

Haemoglobin levels in perioperative period. Legend: # - significant difference PRESSURE vs. GDFT groups; $ - significant difference PRESSURE vs. CONTROL groups; * - significant difference GDFT vs. CONTROL groups (all ANOVA with Student-Neuman-Keul’s post hoc analysis); the drop against baseline measurement was significant in all groups and time-points

Discussion

In our study, the adoption of a fluid administration protocol guided by pulse pressure variation assessed by continuous non-invasive arterial pressure monitoring seems to be associated with lower rate of postoperative complications compared to standard no-protocol care. Reduced amounts of infused fluids with maintained hemodynamic stability, lower dose of rescue vasoactive medication and lower rate of transfusion requirements were observed among patients of the GDFT group compared to CONTROL patients.

Fluid administration based on protocols with use of goal-directed hemodynamic optimization seems to be associated with improved postoperative outcomes in high risk surgical patients [3]. However, among intermediate risk patients, (for instance total hip or knee replacement) the evidence has been scarce and liberal strategies without proper monitoring are often accepted. Holte et al. [18] observed lower incidence in postoperative vomiting among patients managed with the liberal as opposed to the restrictive approach. The authors of this study hypothesized that preoperative fasting might influence this outcome and that a liberal regimen helps to cover the preoperative hypovolemia. According to values of PPV observed after induction, our patients were not hypovolemic before the procedure. In such cases a liberal approach might drive them into hypervolemia and resulting hemodilution. Red blood cell transfusions can exhibit immunosuppressive effect [19] and lead to increased incidence of infectious complications. In our study the protocol approach to fluid administration itself (PRESSURE group) was associated with a trend towards better clinical outcomes and lower transfusion needs. But it seems that only a complex protocol (restrictive maintenance with fluid responsiveness assessment- GDFT group) can adapt for the variable blood loss and individual needs. This is supported by our results or by the study by Cecconi [13]. In that trial, goal-directed fluid management was further combined with dopexamine infusion in order to reach a predefined goal of oxygen delivery. Lower incidence of cardiac and minor organ complications was observed, resembling our data. However, the use of inotropic support might be questioned in patients without significant cardiac morbidity and the use of arterial catheters is also not standard for these procedures.

The outcomes of the GDFT group patients show that fluid optimization itself might be sufficient in this intermediate risk population. Recent meta-analysis demonstrated that dynamic predictors of fluid responsiveness are useful as goals of perioperative GDT [11]. Using them is much easier than complex cardiac output monitoring and oxygen delivery calculation. In addition, the number of limitations in intermediate risk groups seems to be much lower than reported by Maguire [12]: atrial fibrillation was present only in 3 (3 %) out of 97 eligible patients and no other limitations for the use of PPV were observed among our patients. The ventilation strategy (tidal volume of 8 ml/kg and positive end expiratory pressure of 0.6 kPa) is in line with recent recommendations for intraoperative protective ventilation [20], but still enabling the use of dynamic variations. An important aspect of our trial is that the protocol was based on measurements obtained totally non-invasively.

Our study is the first one using the novel non-invasive continuous pressure device based on volume-clamped method for goal-directed treatment. Both the reliability and limits of the measurement should be recognized, even though the device is marketed worldwide and approved by most certification authorities. As for now three large scale [2123] and multiple smaller studies demonstrated the validity of the pressure values obtained by the CNAP® monitor, showing acceptable agreement with direct arterial pressure monitoring. Some inaccuracies seem to exist in cases of profound pressure fluctuations (i.e. deep hypotension following anesthesia induction etc.). The trending ability remained unaffected by these inaccuracies [24, 25]. In addition, as pointed out by Hahn [22], the device uses the oscillometric cuff as a reference, making it equivalent to contemporary practice in the studied population. It was demonstrated by our group [26] as well as by others [27, 28] that the use of continuous non-invasive pressure monitoring devices enables faster recognition of blood pressure drops and helps to maintain the hemodynamic stability during surgery. The reliability of the PPV values obtained by the CNAP® monitor was tested recently by two studies and was found to be comparable to its invasively assessing counterparts [29, 30]. Given these positive factors, the CNAP® device is already widely and routinely used in many clinical institutions; therefore our study could serve as a proof of concept for this praxis.

The design of our study poses an important selection and assessment bias and hence limits the generalizability of our results. Firstly, the use of a two-stage (“before and after”) design does not allow us to compare the CONTROL group and protocol groups in parallel. However, our aim was to quantify the effect of change in approach during the unique moment of transition between no-protocol and protocol-led care. In order to avoid selection bias, all patients undergoing the procedure within the defined stages were found eligible. In the first stage there were no dropouts and only a limited number of patients was excluded during the second stage. Secondly, our study was not set to evaluate between the groups of phase two so we can derive only indirect conclusions in regard of superiority of the goal-directed fluid optimization over the restrictive regimen. This observed difference resulted mainly from the lower incidence of minor infectious complications (mostly urinary tract and surgical site infections). Besides blood and fluids management this might also be confounded by a slightly uneven distribution of comorbidities. Even though not statistically significant, patients in the GDFT group tended to be healthier. This could influence both the transfusion trigger and also the risk for complications as well as help reach the predefined readiness for discharge criteria earlier.

Beside these specific limitations, our trial suffers from flaws inherent to single centre studies with “keen investigators” and a low number of patients. This might be especially true for intermediate risk patients with a low number of complications. For this reason our conclusions should be regarded as a hypothesis generating at best. A much larger study would be necessary to prove this concept. However, it seems that the use of the continuous non-invasive arterial pressure device might offer a safe alternative for monitoring and enable better adoption of fluid protocols.

Conclusions

In conclusion, in our study the transition from standard no-protocol treatment to the fluid management protocol based on pulse pressure variation assessed by continuous non-invasive arterial pressure measurement seems to be associated with reduction of postoperative infections, of organ complications, and of transfusion needs.

Acknowledgement

The study was supported by the Charles University Research Fund (project number P36), the open access fee was granted by the CNSystems Graz, Austria.

The CNAP® Monitor and Task Force® Monitor software were supplied by CNSystems, Graz, Austria.

There were no additional payments depending on the results of the study.

Abbreviations

ASA

American Society of Anesthesiology physical status

CNAP

Continuous Non-invasive Arterial Pressure (name of the device)

CONTROL

Name of the prospective observational group

GDFT

Name of the randomized group with fluid management based on pulse pressure variation

GDT

Goal-directed therapy

GIT

Gastro-intestinal tract

HR

Heart rate

ICU

Intensive Care Unit

MAC

Minimal alveolar concentration

MAP

Mean arterial pressure

PPV

Pulse pressure variation

PONV

Postoperative nausea and vomiting

PRESSURE

Name of the randomized group based on standard fluid management

WHO

World Health Organization

Additional files

Additional file 1: (217.5KB, doc)

The CONSORT Check list. (DOC 217 kb)

Additional file 2: (15.9KB, docx)

List of predefined morbidity criteria for ICU and hospital discharge and list of complications. (DOCX 15 kb)

Footnotes

Competing interests

JB is an advisory board member for Edwards Lifesciences Inc., all other co-authors declare to have no competing interests.

Authors’ contributions

JB: Designed the study, performed the data analysis and wrote the manuscript. LH, JP and JS: Performed the patients’ recruitment, randomization and anaesthesia care, revised the manuscript. AS: Was responsible for the postoperative clinical assessment and revised the manuscript. JZ and RP: Performed the clinical assessment of the observational group and helped to write the manuscript. ICh and EK: Helped to design the study, participated on data analysis and writing the manuscript. All authors approved the final form of the text.

References

  • 1.Srinivasa S, Kahokehr A, Soop M, Taylor M, Hill AG. Goal-directed fluid therapy- a survey of anaesthetists in the UK, USA, Australia and New Zealand. BMC Anesthesiol. 2013;13:5. doi: 10.1186/1471-2253-13-5. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 2.Hamilton MA, Cecconi M, Rhodes A. A systematic review and meta-analysis on the Use of preemptive hemodynamic intervention to improve postoperative outcomes in moderate and high-risk surgical patients. Anesth Analg. 2011;112(6):1392–402. doi: 10.1213/ANE.0b013e3181eeaae5. [DOI] [PubMed] [Google Scholar]
  • 3.Corcoran T, Rhodes JEJ, Clarke S, Myles PS, Ho KM. Perioperative fluid management strategies in major surgery: a stratified meta-analysis. Anesth Analg. 2012;114(3):640–51. doi: 10.1213/ANE.0b013e318240d6eb. [DOI] [PubMed] [Google Scholar]
  • 4.Grocott MPW, Dushianthan A, Hamilton MA, Mythen MG, Harrison D, Rowan K, et al. Perioperative increase in global blood flow to explicit defined goals and outcomes after surgery: a cochrane systematic review. Br J Anaesth. 2013;111(4):535–48. doi: 10.1093/bja/aet155. [DOI] [PubMed] [Google Scholar]
  • 5.Cecconi M, Bennett D. Should we use early less invasive hemodynamic monitoring in unstable ICU patients? Crit Care. 2011;15(4):173. doi: 10.1186/cc10287. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 6.Bundgaard-Nielsen M, Secher NH, Kehlet H. ‘Liberal’ vs. ‘restrictive’ perioperative fluid therapy--a critical assessment of the evidence. Acta Anaesthesiol Scand. 2009;53(7):843–51. doi: 10.1111/j.1399-6576.2009.02029.x. [DOI] [PubMed] [Google Scholar]
  • 7.Glassford NJ, Myles P, Bellomo R. The Australian approach to peri-operative fluid balance. Curr Opin Anaesthesiol. 2012;25(1):102–10. doi: 10.1097/ACO.0b013e32834decd7. [DOI] [PubMed] [Google Scholar]
  • 8.Cannesson M, Pestel G, Ricks C, Hoeft A, Perel A. Hemodynamic monitoring and management in patients undergoing high risk surgery: a survey among North American and European anesthesiologists. Crit Care. 2011;15(4):R197. doi: 10.1186/cc10364. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 9.Forget P, Lois F, de Kock M. Goal-directed fluid management based on the pulse oximeter-derived pleth variability index reduces lactate levels and improves fluid management. Anesth Analg. 2010;111(4):910–4. doi: 10.1213/ANE.0b013e3181eb624f. [DOI] [PubMed] [Google Scholar]
  • 10.Lopes MR, Oliveira MA, Pereira V, Lemos I, Auler J, Michard F. Goal-directed fluid management based on pulse pressure variation monitoring during high-risk surgery: a pilot randomized controlled trial. Crit Care. 2007;11(5):R100. doi: 10.1186/cc6117. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 11.Benes J, Giglio M, Brienza N, Michard F. The effects of goal-directed fluid therapy based on dynamic parameters on post-surgical outcome: a meta-analysis of randomized controlled trials. Crit Care. 2014;18(5):584. doi: 10.1186/s13054-014-0584-z. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 12.Maguire S, Rinehart J, Vakharia S, Cannesson M. Technical communication: respiratory variation in pulse pressure and plethysmographic waveforms: intraoperative applicability in a North American academic center. Anesth Analg. 2011;112(1):94–6. doi: 10.1213/ANE.0b013e318200366b. [DOI] [PubMed] [Google Scholar]
  • 13.Cecconi M, Fasano N, Langiano N, Divella M, Costa M, Rhodes A, et al. Goal directed haemodynamic therapy during elective total hip arthroplasty under regional anaesthesia. Crit Care. 2011;15(3):R132. doi: 10.1186/cc10246. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 14.Scheer B, Perel A, Pfeiffer UJ. Clinical review: complications and risk factors of peripheral arterial catheters used for haemodynamic monitoring in anaesthesia and intensive care medicine. Crit Care. 2002;6(3):199–204. doi: 10.1186/cc1489. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 15.Schulz KF, Altman DG, Moher D, CONSORT Group CONSORT 2010 statement: updated guidelines for reporting parallel group randomised trials. BMJ. 2010;340:c332. doi: 10.1136/bmj.c332. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 16.Fortin J, Marte W, Grüllenberger R, Hacker A, Habenbacher W, Heller A, et al. Continuous non-invasive blood pressure monitoring using concentrically interlocking control loops. Comput Biol Med. 2006;36(9):941–57. doi: 10.1016/j.compbiomed.2005.04.003. [DOI] [PubMed] [Google Scholar]
  • 17.Benes J, Chytra I, Altmann P, Hluchy M, Kasal E, Svitak R, et al. Intraoperative fluid optimization using stroke volume variation in high risk surgical patients: results of prospective randomized study. Crit Care. 2010;14(3):R118. doi: 10.1186/cc9070. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 18.Holte K, Kristensen BB, Valentiner L, Foss NB, Husted H, Kehlet H. Liberal versus restrictive fluid management in knee arthroplasty: a randomized, double-blind study. Anesth Analg. 2007;105(2):465–74. doi: 10.1213/01.ane.0000263268.08222.19. [DOI] [PubMed] [Google Scholar]
  • 19.Vamvakas EC. White-blood-cell-containing allogeneic blood transfusion and postoperative infection or mortality: an updated meta-analysis. Vox Sang. 2007;92(3):224–32. doi: 10.1111/j.1423-0410.2006.00889.x. [DOI] [PubMed] [Google Scholar]
  • 20.Futier E, Constantin JM, Paugam-Burtz C, Pascal J, Eurin M, Neuschwander A, et al. A trial of intraoperative low-tidal-volume ventilation in abdominal surgery. N Engl J Med. 2013;369(5):428–37. doi: 10.1056/NEJMoa1301082. [DOI] [PubMed] [Google Scholar]
  • 21.Biais M, Vidil L, Roullet S, Masson F, Quinart A, Revel P, et al. Continuous non-invasive arterial pressure measurement: evaluation of CNAP device during vascular surgery. Ann Fr Anesth Reanim. 2010;29(7–8):530–5. doi: 10.1016/j.annfar.2010.05.002. [DOI] [PubMed] [Google Scholar]
  • 22.Hahn R, Rinösl H, Neuner M, Kettner SC. Clinical validation of a continuous non-invasive haemodynamic monitor (CNAP 500) during general anaesthesia. Br J Anaesth. 2012;108(4):581–5. doi: 10.1093/bja/aer499. [DOI] [PubMed] [Google Scholar]
  • 23.Jeleazcov C, Krajinovic L, Münster T, Birkholz T, Fried R, Schüttler J, et al. Precision and accuracy of a new device (CNAPTM) for continuous non-invasive arterial pressure monitoring: assessment during general anaesthesia. Br J Anaesth. 2010;105(3):264–72. doi: 10.1093/bja/aeq143. [DOI] [PubMed] [Google Scholar]
  • 24.Ilies C, Bauer M, Berg P, Rosenberg J, Hedderich J, Bein B, et al. Investigation of the agreement of a continuous non-invasive arterial pressure device in comparison with invasive radial artery measurement. Br J Anaesth. 2012;108(2):202–10. doi: 10.1093/bja/aer394. [DOI] [PubMed] [Google Scholar]
  • 25.Gayat E, Mongardon N, Tuil O, Sievert K, Chazot T, Liu N, et al. CNAP(®) does not reliably detect minimal or maximal arterial blood pressures during induction of anaesthesia and tracheal intubation. Acta Anaesthesiol Scand. 2013;57(4):468–73. doi: 10.1111/aas.12028. [DOI] [PubMed] [Google Scholar]
  • 26.Benes J, Simanova A, Tovarnicka T, Sevcikova S, Kletecka J, Zatloukal J, et al. Continuous non-invasive monitoring improves blood pressure stability in upright position: randomized controlled trial. J Clin Monit Comput. 2014. [DOI] [PubMed]
  • 27.Chen G, Chung E, Meng L, Alexander B, Vu T, Rinehart J, et al. Impact of non invasive and beat-to-beat arterial pressure monitoring on intraoperative hemodynamic management. J Clin Monit Comput. 2012;26(2):133–40. doi: 10.1007/s10877-012-9344-2. [DOI] [PubMed] [Google Scholar]
  • 28.Ilies C, Kiskalt H, Siedenhans D, Meybohm P, Steinfath M, Bein B, et al. Detection of hypotension during Caesarean section with continuous non-invasive arterial pressure device or intermittent oscillometric arterial pressure measurement. Br J Anaesth. 2012;109(3):413–9. doi: 10.1093/bja/aes224. [DOI] [PubMed] [Google Scholar]
  • 29.Biais M, Stecken L, Ottolenghi L, Roullet S, Quinart A, Masson F, et al. The ability of pulse pressure variations obtained with CNAP™ device to predict fluid responsiveness in the operating room. Anesth Analg. 2011;113(3):523–8. doi: 10.1213/ANE.0b013e3182240054. [DOI] [PubMed] [Google Scholar]
  • 30.Monnet X, Dres M, Ferré A, Le Teuff G, Jozwiak M, Bleibtreu A, et al. Prediction of fluid responsiveness by a continuous non-invasive assessment of arterial pressure in critically ill patients: comparison with four other dynamic indices. Br J Anaesth. 2012;109(3):330–8. doi: 10.1093/bja/aes182. [DOI] [PubMed] [Google Scholar]

Articles from BMC Anesthesiology are provided here courtesy of BMC

RESOURCES