Abstract
A high speed pneumatic drill was used to perform 190 percutaneous transthoracic biopsies in 161 patients. The resultant cores of tissue provided a definite diagnosis in 146 patients, giving a success rate of 90.7%. Complications occurred in 58 patients, subcutaneous emphysema being the most common, though only seven patients required active treatment, giving a rate of 3.7% for important complications. One patient died within 24 hours of the biopsy procedure owing to asphyxia resulting from aspiration of the contents of an acutely dilated stomach. Our experience clearly establishes that the drill biopsy as used by us is simple and safe and can be carried out in an outpatient department, yielding better overall results than any other procedure for closed biopsy of the lung currently practised.
Full text
PDF




Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Andersen H. A. Transbronchoscopic lung biopsy for diffuse pulmonary diseases. Results in 939 patients. Chest. 1978 May;73(5 Suppl):734–736. [PubMed] [Google Scholar]
- Berger R. L., Dargan E. L., Huang B. L. Dissemination of cancer cells by needle biopsy of the lung. J Thorac Cardiovasc Surg. 1972 Mar;63(3):430–432. [PubMed] [Google Scholar]
- Boylen C. T., Johnson N. R., Richters V., Balchum O. J. High speed trephine lung biopsy: methods and results. Chest. 1973 Jan;63(1):59–62. doi: 10.1378/chest.63.1.59. [DOI] [PubMed] [Google Scholar]
- Burt M. E., Flye M. W., Webber B. L., Wesley R. A. Prospective evaluation of aspiration needle, cutting needle, transbronchial, and open lung biopsy in patients with pulmonary infiltrates. Ann Thorac Surg. 1981 Aug;32(2):146–153. doi: 10.1016/s0003-4975(10)61021-1. [DOI] [PubMed] [Google Scholar]
- DEELEY T. J. Drill biopsy. Results with a high speed pneumatic drill. Acta Unio Int Contra Cancrum. 1960;16:338–340. [PubMed] [Google Scholar]
- Dahhan A. Drill lung biopsy. JAMA. 1973 May 7;224(6):904–904. [PubMed] [Google Scholar]
- Early G. L., Williams T. E., Kilman J. W. Open lung biopsy. Its effects on therapy in the pediatric patient. Chest. 1985 Apr;87(4):467–469. doi: 10.1378/chest.87.4.467. [DOI] [PubMed] [Google Scholar]
- Finley R., Kieff E., Thomsen S., Fennessy J., Beem M., Lerner S., Morello J. Bronchial brushing in the diagnosis of pulmonary disease in patients at risk for opportunistic infection. Am Rev Respir Dis. 1974 Mar;109(3):379–387. doi: 10.1164/arrd.1974.109.3.379. [DOI] [PubMed] [Google Scholar]
- Fontana R. S., Miller W. E., Beabout J. W., Payne W. S., Harrison E. G., Jr Transthoracic needle aspiration of discrete pulmonary lesions: experience in 100 cases. Med Clin North Am. 1970 Jul;54(4):961–971. [PubMed] [Google Scholar]
- Herman P. G., Hessel S. J. The diagnostic accuracy and complications of closed lung biopsies. Radiology. 1977 Oct;125(1):11–14. doi: 10.1148/125.1.11. [DOI] [PubMed] [Google Scholar]
- Jaffe J. P., Maki D. G. Lung biopsy in immunocompromised patients: one institution's experience and an approach to management of pulmonary disease in the compromised host. Cancer. 1981 Sep 1;48(5):1144–1153. doi: 10.1002/1097-0142(19810901)48:5<1144::aid-cncr2820480518>3.0.co;2-4. [DOI] [PubMed] [Google Scholar]
- Jameson J. B. Aspiration biopsy of localized intrathoracic lesions. Australas Radiol. 1970 Feb;14(1):40–45. doi: 10.1111/j.1440-1673.1970.tb02568.x. [DOI] [PubMed] [Google Scholar]
- Khan M. A., Corona F., Masson R. G., Whitcomb M. E. Letter: Transbronchial lung biopsy for sarcoidosis. N Engl J Med. 1976 Jul 22;295(4):225–225. doi: 10.1056/nejm197607222950416. [DOI] [PubMed] [Google Scholar]
- King E. G., Bachynski J. E., Mielke B. Percutaneous trephine lung biopsy: evolving role. Chest. 1976 Aug;70(2):212–216. doi: 10.1378/chest.70.2.212. [DOI] [PubMed] [Google Scholar]
- LAUBY V. W., BURNETT W. E., ROSEMOND G. P., TYSON R. R. VALUE AND RISK OF BIOPSY OF PULMONARY LESIONS BY NEEDLE ASPIRATION. TWENTY-ONE YEARS' EXPERIENCE. J Thorac Cardiovasc Surg. 1965 Jan;49:159–172. [PubMed] [Google Scholar]
- Lalli A. F., Naylor B., Whitehouse W. M. Aspiration biopsy of thoracic lesions. Thorax. 1967 Sep;22(5):404–407. doi: 10.1136/thx.22.5.404. [DOI] [PMC free article] [PubMed] [Google Scholar]
- McEvoy R. D., Begley M. D., Antic R. Percutaneous biopsy of intrapulmonary mass lesions. Experience with a disposable cutting needle. Cancer. 1983 Jun 15;51(12):2321–2326. doi: 10.1002/1097-0142(19830615)51:12<2321::aid-cncr2820511226>3.0.co;2-s. [DOI] [PubMed] [Google Scholar]
- STEELE J. D. THE SOLITARY PULMONARY NODULE. REPORT OF A COOPERATIVE STUDY OF RESECTED ASYMPTOMATIC SOLITARY PULMONARY NODULES IN MALES. J Thorac Cardiovasc Surg. 1963 Jul;46:21–39. [PubMed] [Google Scholar]
- Sagel S. S., Ferguson T. B., Forrest J. V., Roper C. L., Weldon C. S., Clark R. E. Percutaneous transthoracic aspiration needle biopsy. Ann Thorac Surg. 1978 Nov;26(5):399–405. doi: 10.1016/s0003-4975(10)62917-7. [DOI] [PubMed] [Google Scholar]
- Sinner W. N. Complications of percutaneous transthoracic needle aspiration biopsy. Acta Radiol Diagn (Stockh) 1976 Nov;17(6):813–828. doi: 10.1177/028418517601700609. [DOI] [PubMed] [Google Scholar]
- Sooby D. L., Jackson H. L., Sandrock A. R., Rich R. D. Radiation exposure to radiologists during bronchial brush biopsies. Radiology. 1973 May;107(2):305–307. doi: 10.1148/107.2.305. [DOI] [PubMed] [Google Scholar]
- Stampfel G. Anaphylaktoide Reaktion als seltene Komplikation der Lungen-Feinnadelpunktion. Radiologe. 1982 Jul;22(7):329–330. [PubMed] [Google Scholar]
- Steel S. J., Winstanley D. P. Trephine biopsy of the lung and pleura. Thorax. 1969 Sep;24(5):576–584. doi: 10.1136/thx.24.5.576. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Stringfield J. T., Markowitz D. J., Bentz R. R., Welch M. H., Weg J. G. The effect of tumor size and location on diagnosis by fiberoptic bronchoscopy. Chest. 1977 Oct;72(4):474–476. doi: 10.1378/chest.72.4.474. [DOI] [PubMed] [Google Scholar]
- Theodos P. A. Lung biopsy in the diagnosis of the pneumoconioses. Dis Chest. 1968 Mar;53(3):271–281. doi: 10.1378/chest.53.3.271. [DOI] [PubMed] [Google Scholar]
- Westcott J. L. Air embolism complicating percutaneous needle biopsy of the lung. Chest. 1973 Jan;63(1):108–110. doi: 10.1378/chest.63.1.108. [DOI] [PubMed] [Google Scholar]
- Wightman A. J., Douglas A. C. Fluoroscopically controlled transbronchial biopsy of solitary peripheral pulmonary lesions using the fibreoptic bronchoscope. Clin Radiol. 1978 Nov;29(6):621–624. doi: 10.1016/s0009-9260(78)80183-4. [DOI] [PubMed] [Google Scholar]
- Wilson J. R., Jones R. L., Mielke B., King E. G. Trephine lung biopsy. Can Med Assoc J. 1973 Mar 17;108(6):704–709. [PMC free article] [PubMed] [Google Scholar]
- Zavala D. C., Bedell G. N., Rossi N. P. Trephine lung biopsy with a high-speed air drill. Results of 50 biopsies in 47 patients. J Thorac Cardiovasc Surg. 1972 Aug;64(2):220–228. [PubMed] [Google Scholar]