Prediction of oxygenation during sleep in patients with chronic obstructive lung disease.

J L McKeon 1, K Murree-Allen 1, N A Saunders 1
PMCID: PMC461219  PMID: 3406918

Abstract

The accuracy of a prediction equation for assessing the lowest arterial oxygen saturation (SaO2) during sleep was determined in 24 consecutive patients with chronic obstructive lung disease referred for assessment for home oxygen therapy. Subjects had a mean (SD) FEV1 of 0.81 (0.31) litre and an FEV1/FVC of 37% (12%). There was reasonable agreement between predicted and measured values (mean difference [predicted-measured] = -2.5%) but the prediction was not precise as the 95% confidence interval for the difference was +8% to -13%. The duration of arterial oxygen desaturation, defined as the percentage of total sleep time spent below a given SaO2, was not predicted accurately. It is concluded that nocturnal arterial oxygen desaturation in individual patients with chronic obstructive lung disease cannot be predicted from "awake" measurements with sufficient accuracy to be clinically useful.

Full text

PDF
312

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Bland J. M., Altman D. G. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986 Feb 8;1(8476):307–310. [PubMed] [Google Scholar]
  2. Breslin A. B., Colebatch H. J., Engel L., Woolcock A. J. Domiciliary oxygen treatment. Med J Aust. 1985 Apr 29;142(9):508–510. [PubMed] [Google Scholar]
  3. Calverley P. M., Brezinova V., Douglas N. J., Catterall J. R., Flenley D. C. The effect of oxygenation on sleep quality in chronic bronchitis and emphysema. Am Rev Respir Dis. 1982 Aug;126(2):206–210. doi: 10.1164/arrd.1982.126.2.206. [DOI] [PubMed] [Google Scholar]
  4. Catterall J. R., Douglas N. J., Calverley P. M., Shapiro C. M., Brezinova V., Brash H. M., Flenley D. C. Transient hypoxemia during sleep in chronic obstructive pulmonary disease is not a sleep apnea syndrome. Am Rev Respir Dis. 1983 Jul;128(1):24–29. doi: 10.1164/arrd.1983.128.1.24. [DOI] [PubMed] [Google Scholar]
  5. Cormick W., Olson L. G., Hensley M. J., Saunders N. A. Nocturnal hypoxaemia and quality of sleep in patients with chronic obstructive lung disease. Thorax. 1986 Nov;41(11):846–854. doi: 10.1136/thx.41.11.846. [DOI] [PMC free article] [PubMed] [Google Scholar]
  6. Douglas N. J., Calverley P. M., Leggett R. J., Brash H. M., Flenley D. C., Brezinova V. Transient hypoxaemia during sleep in chronic bronchitis and emphysema. Lancet. 1979 Jan 6;1(8106):1–4. doi: 10.1016/s0140-6736(79)90451-3. [DOI] [PubMed] [Google Scholar]
  7. Fleetham J., West P., Mezon B., Conway W., Roth T., Kryger M. Sleep, arousals, and oxygen desaturation in chronic obstructive pulmonary disease. The effect of oxygen therapy. Am Rev Respir Dis. 1982 Sep;126(3):429–433. doi: 10.1164/arrd.1982.126.3.429. [DOI] [PubMed] [Google Scholar]
  8. Flick M. R., Block A. J. Continuous in-vivo monitoring of arterial oxygenation in chronic obstructive lung disease. Ann Intern Med. 1977 Jun;86(6):725–730. doi: 10.7326/0003-4819-86-6-725. [DOI] [PubMed] [Google Scholar]
  9. Koo K. W., Sax D. S., Snider G. L. Arterial blood gases and pH during sleep in chronic obstructive pulmonary disease. Am J Med. 1975 May;58(5):663–670. doi: 10.1016/0002-9343(75)90502-1. [DOI] [PubMed] [Google Scholar]
  10. Phillipson E. A., Goldstein R. S. Breathing during sleep in chronic obstructive pulmonary disease. State of the art. Chest. 1984 Jun;85(6 Suppl):24S–30S. doi: 10.1378/chest.85.6.24s. [DOI] [PubMed] [Google Scholar]
  11. Slutsky A. S., Strohl K. P. Quantification of oxygen saturation during episodic hypoxemia. Am Rev Respir Dis. 1980 May;121(5):893–895. doi: 10.1164/arrd.1980.121.5.893. [DOI] [PubMed] [Google Scholar]
  12. Stradling J. R., Lane D. J. Nocturnal hypoxaemia in chronic obstructive pulmonary disease. Clin Sci (Lond) 1983 Feb;64(2):213–222. doi: 10.1042/cs0640213. [DOI] [PubMed] [Google Scholar]
  13. West P., George C. F., Kryger M. H. Dynamic in vivo response characteristics of three oximeters: Hewlett-Packard 47201A, Biox III, and Nellcor N-100. Sleep. 1987 Jun;10(3):263–271. doi: 10.1093/sleep/10.3.263. [DOI] [PubMed] [Google Scholar]

Articles from Thorax are provided here courtesy of BMJ Publishing Group

RESOURCES