Skip to main content
European Journal of Medical Research logoLink to European Journal of Medical Research
. 2015 Oct 29;20:87. doi: 10.1186/s40001-015-0184-7

Malpositioned olecranon fracture tension-band wiring results in proximal radioulnar synostosis

Lukas Willinger 1,#, Martin Lucke 1,#, Moritz Crönlein 1, Gunther H Sandmann 1, Peter Biberthaler 1, Sebastian Siebenlist 1,
PMCID: PMC4625882  PMID: 26514829

Abstract

Background

Tension-band wiring (TBW) is a well-established fixation technique for two-part, transverse fracture types of the olecranon. However, complication rates up to 80 % are reported. By reporting on the enormous impact on the patient if failed the aim of the present report was to emphasize the importance of correct K wire positioning in TBW.

Case presentation

We present the case of a 49-year-old woman who suffered from a radioulnar synostosis of the forearm due to malpositioned K wires after TBW treatment. The patient was treated by heterotopic bone resection supported by ossification prophylaxis (radiotherapy and Indomethacin). At follow-up of 12 months after revision surgery, elbow motion was unrestricted with a strength grade 5/5. The patient was free of pain and reported no restrictions in daily as well as sporting activities. Radiologic assessment showed no recurrence of heterotopic bone tissue.

Conclusion

Intraoperative radiographic and clinical examination of the elbow is highly recommended to identify incorrect hardware positioning and, therefore, to avoid serious postoperative complications in TBW.

Keywords: Olecranon fracture, Tension-band wiring, Radioulnar synostosis, Complication, Radiotherapy

Background

Isolated olecranon fractures are the most common fractures of the proximal ulna and account for 10 % of upper extremity fractures. The direct fall onto the elbow is the main injury pattern [1, 2]. Surgical treatment depends on the grade of fracture dislocation and the number of bony fragments [3]. Tension-band wiring (TBW) is a well-established fixation technique for two-part, transverse fracture types of the olecranon with sufficient bone quality [3, 4]. Even though TBW is often considered as an easy and convenient surgical procedure, several imperfections are described in the current literature and complication rates up to 80 % are reported [58]. Proximal migration of Kirschner (K) wires followed by the necessity of early hardware removal is the most frequent complication in case K wires are inserted into the medullary canal of the distal ulna fragment [5]. To avoid this complication, the modified technique involving the transcortical K wire placement through the anterior cortex of the ulna has been introduced [9, 10]. Nevertheless, extensive hardware protrusion through the anterior ulnar cortex may result in nerve and/or vascular injuries, impaired range of elbow motion and heterotopic ossification (HO) [1115].

In the following case, we refer a proximal radioulnar synostosis (RUS) following TBW of a simple transverse olecranon fracture. To our research of the literature, there are just two articles on this topic, and only one of them reported about the therapeutic management of this severe complication [15, 16]. The purpose of the present article is, therefore, to emphasize the importance of correct K wire insertion during the TBW procedure by reporting on the enormous impact on the patient if failed. The surgical approach including pre- and postoperative measures is described in detail and discussed with reference to the current literature.

Case presentation

A 49-year-old woman sustained a two-part olecranon fracture (AO 21-B1, Mayo type IIA [17]) in her left elbow. She was consequently treated by open reduction and internal fixation using the transcortical TBW technique. Immediately after surgery the patient complained about persistent pain in her elbow, wrist and shoulder as well as strong difficulties to rotate the forearm during physiotherapy. Despite the reported complaints the patient was advised to intensify physiotherapy. Follow-up radiographs 6 weeks postoperatively revealed not only union of the olecranon fracture, but also extensive protrusion of the K wires through the anterior ulnar cortex scratching the radial tuberosity (Fig. 1). Both K wires were consequently removed in a second operation, but the tension-band cerclage remained at its position. After K wires removal, the patient was encouraged again to enforce physiotherapy.

Fig. 1.

Fig. 1

Malpositioned K wires after olecranon TBW. 3D computed tomography scans show the K wire placement within the radioulnar space at the radial tuberosity 6 weeks after initial surgery

Three months after trauma, the patient was presented to our outpatient clinic due to a total block of supination and pronation with the forearm fixed in neutral position. The extension–flexion arc of the elbow was 0°–5°–110°. Wrist and shoulder examinations showed a free range of motion (ROM); pain or sensomotoric restrictions did not exist. Radiographs showed a massive synostosis between the radial tuberosity and the proximal ulna where previously the K wires had penetrated the anterior radial cortex of the ulna (Fig. 2). Based on clinical and radiographic findings the resection of the synostotic bone was indicated to restore forearm motion.

Fig. 2.

Fig. 2

Proximal radioulnar synostosis. a Massive radioulnar synostosis (white arrows) at the level of the radial tuberosity 3 months after initial surgery. The olecranon fracture is healed while the cerclage wire remained in situ. b CT scans show the heterotopic ossification starting from the distal biceps tendon (white star) insertion to the ulnar cortex

Two hours before revision surgery, a prophylactic radiotherapy (with a dosage of 7 Gy) focused on the proximal aspect of the forearm was performed to minimize the risk of synostotic recurrence [18, 19]. The previously used dorsal approach was reopened and the remaining cerclage wire was removed a priori. Next, the approach was extended distally and the supinator muscle was subperiosteally detached en bloc from the proximal ulna to expose the heterotopic bone formation (Fig. 3). We decided for that approach to protect the posterior interosseous nerve (PIN) running through the supinator mass. The synostotic bone was first exposed from its proximal to its distal extent. Second, by subperiosteal preparation the heterotopic bone formation was dissected step-by-step to its radial extent at the radial tuberosity. This preparation was mainly performed by chiseling along well attached to the bone. Thereby, it was carefully observed not to damage the distal biceps tendon that was immured by heterotopic bone. The synostosis was finally removed all in one. Subsequent intraoperative examination revealed full pronation and supination movements before closure. For rehabilitation, active and passive elbow exercises including immediate free forearm rotation started under physiotherapist’s supervision the day after surgery. No splint or cast was applied. Indomethacin (50 mg 1–0–1 per day) was prescribed for 2 weeks for prophylaxis of ossification [20].

Fig. 3.

Fig. 3

Dorsoradial approach for revision. Dorsoradial approach (black star olecranon tip) in prone position. After subperiosteal en bloc detachment of the supinator muscle (white star) from the proximal ulna (red arrow) the heterotopic bone formation (forceps) was exposed

Ten weeks postoperatively the ROM of the elbow was 0°–10°–140° for extension–flexion arc and 75°–0°–90° for pronation–supination arc. At final follow-up 12 months after surgery, the ROM was unrestricted when compared to the uninjured arm side (Fig. 4). Supination strength was also unlimited presenting grade 5/5 on both arms. The patient was free of pain and reported no restrictions in daily as well as sporting activities (swimming three times per week). Radiologic assessment showed no recurrence of heterotopic bone tissue.

Fig. 4.

Fig. 4

Unrestricted elbow function 12 months after revision surgery. a Unrestricted pronation and b supination in both arms (left elbow, red stick)

Discussion and conclusion

TBW is often considered an easy-to-use operation technique to treat isolated simple olecranon fractures. Many authors showed good-to-excellent short- to long-term clinical outcomes [2125], however, different complication rates were observed in the literature [1, 7, 1116, 26, 27].

However, the development of an RUS due to hardware protrusion was—to the best of our knowledge—reported in only two articles so far [15, 16]. Velkes et al. [15] presented two cases of RUS following the transcortical technique within 3 months after surgery. The authors supposed as mechanism that the RUS was induced by soft tissue trauma and bleeding resulting from the K wire protrusion into the interosseous membrane and its surroundings. Consequently, secondary haematoma calcification was assumed for RUS development [28, 29]. Because both fractures showed bony healing within 6 weeks, a fracture-related mechanism for the RUS was not proposed by the authors. In contrast, De Carli et al. reported on a case of HO following transcortical malpositioned K wires abutting against the radial cortex [16].

In the present case, the synostotic bone formation also originated probably from the radius, particularly in that area where the K wires have been adjacent to the periosteum. Even though the K wires were removed 6 weeks after index surgery, signs of HOs at the proximal radioulnar joint were already visible (Fig. 2). When compared to other reported cases of RUS, the development of HO in the present case was very fast (probably induced from K wire irritation during forearm rotation within the first 6 weeks). We assume that the ongoing osseous erosion induced an inflammatory process with local release of growth factors (e.g., TGF-β) which contributes to the excessive bone proliferation process [30]. The reported persistent pain during physiotherapy might also be indicative for that suggestion. And additionally, soft tissue trauma during physiotherapy (e.g., of the supinator muscle) might have played a role in HO synthesis [31].

Regarding the clinical outcome, De Carli et al. [16] reported an excellent result after surgical removal of the synostosis and subsequent ossification prophylaxis with Indomethacin after 3 years of follow-up. Radiographs showed no signs of recurrence [16]. Similarly, with a 12 month follow-up the present patient showed excellent functional results and no radiographic signs of recurrent ossification as well. Velkes et al. [15] did not report further therapeutic measures because both patients declined revision.

The development of an RUS has been considered from soft tissue hematoma calcification by several authors [15, 28]. In the context of the present case we do not confirm this theory. The HO resection procedure would have also caused perioperative hematoma but no evidence of recurrent ossification was seen in the postoperative course. To avoid synostotic recurrence, different measures are frequently discussed in the current literature. In contrast to the case reports cited above, additional radiotherapy was performed in the present case before surgery. For lower extremities, it is evident that the combination of radiation and NSAID (non-steroidal anti-inflammatory drugs) should be used for prophylaxis of synostotic recurrence [20]. In upper extremity HOs likewise, a combined therapy regime has shown to successfully prevent synostotic recurrence [18, 32]. HOs around the elbow is not suspected to appear later than 3 months after the initiating trigger (trauma or surgery) [18, 33]. De Carli et al. [16] applied Indomethacin over the period of 6 weeks postoperatively in their case. Their decision was based on the concomitant nonunion of the olecranon fracture and the higher risk of non-healing subsequent to radiotherapy [16, 34]. After intramedullary repositioning of the K wires and excision of HO with osteoperiosteal decortication, fracture union was achieved [16]. The authors supposed that the malpositioned K wires and subsequent RUS might play a role during development of the nonunion by allowing rotational movement to the fracture site [16]. The present olecranon fracture showed bony healing within 6 weeks despite the malpositioned K wires and an impingement at the proximal radius, respectively. Therefore, one might speculate that the synostotic bone development in the present case was not induced due to a mechanical impingement phenomenon resulting in loosened K wires and fracture nonunion, but due to ongoing soft tissue irritation and periosteal microtrauma at the proximal radius. De Carli et al. [16], in their case report, also assumed that the HO developed as a result of periosteal stimulation following K wire impingement during pronation and supination.

To prevent such intraoperative complications and not to harm proximate structures, the explicit knowledge of the proximal forearm anatomy is required. For TBW, current studies recommend to insert the K wires from a more lateral entry point into the olecranon tip and aiming towards the ulnar midshaft to avoid interference with the proximal radial shaft and the proximal radioulnar articulation, respectively [11, 27]. Surgeons have to be aware of the normal varus angulation of the proximal ulna not to place the pins in direction of the radius and to avoid impingement between hardware and radial neck [35, 36]. While K wires are inserted, the forearm should be positioned in supination [11]. Intraoperative fluoroscopic examination is essential to recognize implant interfering with the proximal radius. For TBW and for plating of olecranon fractures as well, a clear proximal radioulnar space (PRUJ, respectively) has to be outlined using a slightly oblique a.p. view during operative procedure (Fig. 5). In addition, an accurate intraoperative assessment of forearm rotation should be performed to ensure free ROM and the absence of noticeable crepitation.

Fig. 5.

Fig. 5

Intraoperative fluoroscopic examination. a TBW after olecranon osteotomy for osteosynthesis of distal humeral fracture (left K wires are directed ulnarly, right the slight oblique a.p. view verifies the free proximal radioulnar space (white arrow); b both views (white arrows) demonstrate the free proximal radioulnar space after plating of the proximal ulna

Impaired rotational movements during rehabilitation have led one to think about interfering pins. In case of inexplicable discomfort and ongoing pain, further radiological assessment (favored CT scans) is indicated because a malpositioning of K wires is often not visible in standard X-rays (a.p. and lateral view). To sum up, accurate operative approach is necessary to avoid such perooperative adverse events in olecranon TBW as described above.

In the present case clinical outcome was excellent after HO resection with supportive radiotherapy and Indomethacin administration. No HO recurrence was detected throughout which might confirm the theory that the RUS was induced due to periostal K wire scratching during forearm rotation resulting in local inflammatory process but not from postoperative hematoma calcification.

Consent

Written informed consent was obtained from the patient for publication of this case report and any accompanying images. A copy of the written consent is available for review by the Editor-in-Chief of this journal.

Authors’ contributions

Guarantors of integrity of entire study, LW, ML, SS; study concepts/design LW, ML, SS; data acquisition and/or data analysis/interpretation, LW, GHS, SS; manuscript drafting, LW, ML, SS; manuscript revision for important intellectual content, all authors; manuscript final version approval, all authors; literature research, LW, MC, PB, SS; and manuscript editing, all authors. All authors read and approved the final manuscript.

Acknowledgements

None.

Competing interests

The authors declare that they have no competing interests.

Abbreviations

HO

heterotopic ossification

K

Kirschner

PIN

posterior interosseous nerve

ROM

range of motion

RUS

radioulnar synostosis

TBW

tension-band wiring

Footnotes

Lukas Willinger and Martin Lucke contributed equally to this work

Contributor Information

Lukas Willinger, Email: lukas.willinger@gmx.at.

Martin Lucke, Email: martin.lucke@mri.tum.de.

Moritz Crönlein, Email: moritz.croenlein@mri.tum.de.

Gunther H. Sandmann, Email: gunther.sandmann@mri.tum.de

Peter Biberthaler, Email: peter.biberthaler@mri.tum.de.

Sebastian Siebenlist, Phone: +49-89-41405039, Email: sebastian.siebenlist@mri.tum.de.

References

  • 1.Karlsson MK, Hasserius R, Karlsson C, Besjakov J, Josefsson PO. Fractures of the olecranon: a 15- to 25-year followup of 73 patients. Clin Orthop Relat Res. 2002;403:205–212. doi: 10.1097/00003086-200210000-00030. [DOI] [PubMed] [Google Scholar]
  • 2.Rommens PM, Kuchle R, Schneider RU, Reuter M. Olecranon fractures in adults: factors influencing outcome. Injury. 2004;35(11):1149–1157. doi: 10.1016/j.injury.2003.12.002. [DOI] [PubMed] [Google Scholar]
  • 3.Newman SD, Mauffrey C, Krikler S. Olecranon fractures. Injury. 2009;40(6):575–581. doi: 10.1016/j.injury.2008.12.013. [DOI] [PubMed] [Google Scholar]
  • 4.Weber BG, Vasey H. Osteosynthesis in Olecranon Fractures. Z Unfallmed Berufskr. 1963;56:90–96. [PubMed] [Google Scholar]
  • 5.Chalidis BE, Sachinis NC, Samoladas EP, Dimitriou CG, Pournaras JD. Is tension band wiring technique the “gold standard” for the treatment of olecranon fractures? A long term functional outcome study. J Orthop Surg Res. 2008;3:9. doi: 10.1186/1749-799X-3-9. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 6.Helm RH, Hornby R, Miller SW. The complications of surgical treatment of displaced fractures of the olecranon. Injury. 1987;18(1):48–50. doi: 10.1016/0020-1383(87)90386-X. [DOI] [PubMed] [Google Scholar]
  • 7.Macko D, Szabo RM. Complications of tension-band wiring of olecranon fractures. J Bone Jt Surg Am. 1985;67(9):1396–1401. [PubMed] [Google Scholar]
  • 8.Schneider MM, Nowak TE, Bastian L, Katthagen JC, Isenberg J, Rommens PM, et al. Tension band wiring in olecranon fractures: the myth of technical simplicity and osteosynthetical perfection. Int Orthop. 2014;38(4):847–855. doi: 10.1007/s00264-013-2208-7. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 9.Mueller ME, Allgower M, Schneider R. Manual of internal fixation: techniques recommended by the AO-ASIF group. Berlin: Springer; 1991. [Google Scholar]
  • 10.Mullett JH, Shannon F, Noel J, Lawlor G, Lee TC, O’Rourke SK. K-wire position in tension band wiring of the olecranon—a comparison of two techniques. Injury. 2000;31(6):427–431. doi: 10.1016/S0020-1383(00)00014-0. [DOI] [PubMed] [Google Scholar]
  • 11.Candal-Couto JJ, Williams JR, Sanderson PL. Impaired forearm rotation after tension-band-wiring fixation of olecranon fractures: evaluation of the transcortical K-wire technique. J Orthop Trauma. 2005;19(7):480–482. doi: 10.1097/01.bot.0000164338.79013.10. [DOI] [PubMed] [Google Scholar]
  • 12.Lee SH, Han SB, Jeong WK, Park JH, Park SY, Patil S. Ulnar artery pseudoaneurysm after tension band wiring of an olecranon fracture resulting in Volkmann’s ischemic contracture: a case report. J Shoulder Elb Surg. 2010;19(2):e6–e8. doi: 10.1016/j.jse.2009.06.007. [DOI] [PubMed] [Google Scholar]
  • 13.Parker JR, Conroy J, Campbell DA. Anterior interosseus nerve injury following tension band wiring of the olecranon. Injury. 2005;36(10):1252–1253. doi: 10.1016/j.injury.2004.12.028. [DOI] [PubMed] [Google Scholar]
  • 14.Thumroj E, Jianmongkol S, Thammaroj J. Median nerve palsy after operative treatment of olecranon fracture. J Med Assoc Thai. 2005;88(10):1434–1437. [PubMed] [Google Scholar]
  • 15.Velkes S, Tytiun Y, Salai M. Proximal radio-ulnar synostosis complicating tension band wiring of the fractured olecranon. Injury. 2005;36(10):1254–1256. doi: 10.1016/j.injury.2004.12.034. [DOI] [PubMed] [Google Scholar]
  • 16.De Carli P, Gallucci GL, Donndorff AG, Boretto JG, Alfie VA. Proximal radio-ulnar synostosis and nonunion after olecranon fracture tension-band wiring: a case report. J Shoulder Elb Surg. 2009;18(3):e40–e44. doi: 10.1016/j.jse.2009.02.005. [DOI] [PubMed] [Google Scholar]
  • 17.Adams JE, Steinmann SP. Fractures of the olecranon. In: Morrey BF, editor. The Elbow and Its Disorders. Philadelphia: WB Saunders; 2009. pp. 389–400. [Google Scholar]
  • 18.Hastings H, 2nd, Graham TJ. The classification and treatment of heterotopic ossification about the elbow and forearm. Hand Clin. 1994;10(3):417–437. [PubMed] [Google Scholar]
  • 19.Popovic M, Agarwal A, Zhang L, Yip C, Kreder HJ, Nousiainen MT, et al. Radiotherapy for the prophylaxis of heterotopic ossification: a systematic review and meta-analysis of published data. Radiother Oncol. 2014;113(1):10–17. doi: 10.1016/j.radonc.2014.08.025. [DOI] [PubMed] [Google Scholar]
  • 20.Board TN, Karva A, Board RE, Gambhir AK, Porter ML. The prophylaxis and treatment of heterotopic ossification following lower limb arthroplasty. J Bone Jt Surg Br. 2007;89(4):434–440. doi: 10.1302/0301-620X.89B4.18845. [DOI] [PubMed] [Google Scholar]
  • 21.Akman S, Erturer RE, Tezer M, Tekesin M, Kuzgun U. Long-term results of olecranon fractures treated with tension-band wiring technique. Acta Orthop Traumatol Turc. 2002;36(5):401–407. [PubMed] [Google Scholar]
  • 22.Flinterman HJ, Doornberg JN, Guitton TG, Ring D, Goslings JC, Kloen P. Long-term outcome of displaced, transverse, noncomminuted olecranon fractures. Clin Orthop Relat Res. 2014;472(6):1955–1961. doi: 10.1007/s11999-014-3481-5. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 23.Lindenhovius AL, Brouwer KM, Doornberg JN, Ring DC, Kloen P. Long-term outcome of operatively treated fracture-dislocations of the olecranon. J Orthop Trauma. 2008;22(5):325–331. doi: 10.1097/BOT.0b013e31817283f7. [DOI] [PubMed] [Google Scholar]
  • 24.Tarallo L, Mugnai R, Adani R, Capra F, Zambianchi F, Catani F. Simple and comminuted displaced olecranon fractures: a clinical comparison between tension band wiring and plate fixation techniques. Arch Orthop Trauma Surg. 2014;134(8):1107–1114. doi: 10.1007/s00402-014-2021-9. [DOI] [PubMed] [Google Scholar]
  • 25.van der Linden SC, van Kampen A, Jaarsma RL. K-wire position in tension-band wiring technique affects stability of wires and long-term outcome in surgical treatment of olecranon fractures. J Shoulder Elb Surg. 2012;21(3):405–411. doi: 10.1016/j.jse.2011.07.022. [DOI] [PubMed] [Google Scholar]
  • 26.Romero JM, Miran A, Jensen CH. Complications and re-operation rate after tension-band wiring of olecranon fractures. J Orthop Sci. 2000;5(4):318–320. doi: 10.1007/s007760070036. [DOI] [PubMed] [Google Scholar]
  • 27.Matthews F, Trentz O, Jacob AL, Kikinis R, Jupiter JB, Messmer P. Protrusion of hardware impairs forearm rotation after olecranon fixation. A report of two cases. J Bone Jt Surg Am. 2007;89(3):638–642. doi: 10.2106/JBJS.E.01238. [DOI] [PubMed] [Google Scholar]
  • 28.Failla JM, Amadio PC, Morrey BF. Post-traumatic proximal radio-ulnar synostosis. Results of surgical treatment. J Bone Jt Surg Am. 1989;71(8):1208–1213. [PubMed] [Google Scholar]
  • 29.Finsen V, Lingaas PS, Storro S. AO tension-band osteosynthesis of displaced olecranon fractures. Orthopedics. 2000;23(10):1069–1072. doi: 10.3928/0147-7447-20001001-18. [DOI] [PubMed] [Google Scholar]
  • 30.Sawyer JR, Myers MA, Rosier RN, Puzas JE. Heterotopic ossification: clinical and cellular aspects. Calcif Tissue Int. 1991;49(3):208–215. doi: 10.1007/BF02556120. [DOI] [PubMed] [Google Scholar]
  • 31.Foruria AM, Augustin S, Morrey BF, Sanchez-Sotelo J. Heterotopic ossification after surgery for fractures and fracture-dislocations involving the proximal aspect of the radius or ulna. J Bone Jt Surg Am. 2013;95(10):e66. doi: 10.2106/JBJS.K.01533. [DOI] [PubMed] [Google Scholar]
  • 32.Beingessner DM, Patterson SD, King GJ. Early excision of heterotopic bone in the forearm. J Hand Surg Am. 2000;25(3):483–488. doi: 10.1053/jhsu.2000.6922. [DOI] [PubMed] [Google Scholar]
  • 33.Garland DE. A clinical perspective on common forms of acquired heterotopic ossification. Clin Orthop Relat Res. 1991;263:13–29. [PubMed] [Google Scholar]
  • 34.Hamid N, Ashraf N, Bosse MJ, Connor PM, Kellam JF, Sims SH, et al. Radiation therapy for heterotopic ossification prophylaxis acutely after elbow trauma: a prospective randomized study. J Bone Jt Surg Am. 2010;92(11):2032–2038. doi: 10.2106/JBJS.I.01435. [DOI] [PubMed] [Google Scholar]
  • 35.Beser CG, Demiryurek D, Ozsoy H, Ercakmak B, Hayran M, Kizilay O, et al. Redefining the proximal ulna anatomy. Surg Radiol Anat. 2014;36(10):1023–1031. doi: 10.1007/s00276-014-1340-4. [DOI] [PubMed] [Google Scholar]
  • 36.Wang AA, Mara M, Hutchinson DT. The proximal ulna: an anatomic study with relevance to olecranon osteotomy and fracture fixation. J Shoulder Elb Surg. 2003;12(3):293–296. doi: 10.1016/S1058-2746(02)86803-3. [DOI] [PubMed] [Google Scholar]

Articles from European Journal of Medical Research are provided here courtesy of BMC

RESOURCES