Abstract
Stems are intramedullary extensions of either the femoral or tibial component of a total knee arthroplasty (TKA) designed to increase the mechanical stability to decrease the risk of aseptic loosening. Biomechanical studies have shown that TKA stems increase the mechanical stability by transferring load over a larger area and thereby reduce strain at the bone-component interface [1–4]. The length of a revision TKA stem is determined by the patient’s anatomy and the intended fixation, namely fully cemented or press-fit cortical contact. The advantages and disadvantages of various stem lengths must be weighed against the needs of the patient to achieve an optimal outcome.
Keywords: Revision, Fixation, Stem, Length, Uncemented, Cemented
Introduction
The evolution to the modern total knee arthroplasty began with initial interposition arthroplasty designs that had existed as early as the 1860s [5]. Knee arthroplasty then evolved to the Walldius hinge arthroplasty in the 1950s which utilized stems to combat the high torsional and bending stresses transmitted to the bone secondary to excessive constraint [6, 7]. The unacceptable early loosening and failure of the hinge designs led to future resurfacing designs with less need for stem fixation. Gunston applied design and surgical philosophies from his partner Sir John Charnley by utilizing a polyethylene bearing and polymethyl methacrylate for fixation [8]. These principles of soft tissue preservation, fixation with bone cement, and incorporation of polyethylene were critical to the development of modern primary knee replacements such as the total condylar prosthesis (TCP) [8]. The cemented TCP design and its uncemented contemporaries such as the Eftekhar Mark I did not utilize stems but rather metaphyseal-engaging posts to maintain stability [9].
Stems were gradually reintroduced as increasingly constrained designs were developed to manage more complex deformities and meet the increasing revision total knee arthroplasty (rTKA) burden [2, 10]. Revision TKA challenges included variable amounts of bone loss and soft tissue incompetence that necessitated improved fixation and increased constraint, respectively, to maintain joint stability. Stems can help bypass compromised articular and metaphyseal bone while also widely distributing the increased stress of a constrained articular fixation [2, 3].
Stem lengths are variable in rTKA but are crucial to the overall success of the reconstruction. Stem length is largely determined by the stem fixation technique. The major stem fixation techniques in modern rTKA are fully cemented and uncemented fixation. Fully cemented stems are generally shorter and metaphyseal engaging. Uncemented stems are predominantly used in a “hybrid” rTKA where the articular component is cemented to the remaining articular surface and the uncemented stem is press-fit to the diaphyseal portion of the bone [10]. Both techniques have advantages and disadvantages that influence their use in rTKA. Understanding the indication for stem use will help the surgeon determine the appropriate technique for stem fixation and length.
Definition of stem length
The contemporary literature on stem use in revision knee arthroplasty is limited to case series or lower quality comparative studies that feature a variety of stem lengths often with little explanation offered as to how stem length was chosen. Increased stability from increased length should not be assumed as one study demonstrated no clear mechanical advantage to stem length or fixation method when comparing 150-mm press-fit stems and 75-mm fully cemented stems [11]. The stem/bone engagement is a more critical concept than absolute stem length. Stem/bone engagement refers to the region of the bone that the stem achieves fixation and is generally divided into either metaphyseal- or diaphyseal-engaging stems. Stems engaging the metaphysis are generally cemented to fill the space between the stem and the bone to eliminate micromotion as this region is wider and consists of more cancellous bone. Stems engaging the diaphysis are generally press-fit as this region is narrower and consists of cortical bone. Diaphyseal engaging press-fit stems are often paired with a cemented articular component which is described as a hybrid technique [10]. Therefore, a more helpful definition of stem length should define stems as metaphyseal-engaging stems (MES) or diaphyseal-engaging stems (DES).
Metaphyseal-engaging stems
Metaphyseal-engaging stems achieve fixation in the metaphysis or metadiaphyseal region of the bone. Both the articular component and stem are cemented into the metaphysis and proximal diaphysis. Uncemented MES constructs have been described; however, higher failure rates were noted [12–14]. Short cemented stems have long been considered the gold standard of revision fixation. These fully cemented stems were often 30–100 mm in length with longer stems reserved for femoral fixation and shorter stems for tibial fixation [13, 15–18].
There are several advantages to shorter stems employed in a cemented fashion (Table 1). A shorter MES allows freedom for medial/lateral and anterior/posterior placement. This flexibility can achieve a better fit for the femoral component in the coronal plane and also optimize the anterior/posterior position to manage the flexion gap. The risk of end-of-stem pain is lower with cemented metaphyseal stems than press-fit diaphyseal stems, however it has been reported with both fixation techniques [19–21]. Shorter cemented stems are more easily deployed in patients with diaphyseal bowing, deformity, or those with ipsilateral hardware. Diaphyseal deformity secondary to previous trauma, dysplasia, or inflammatory arthropathies may not be amenable to a longer DES stem. In these cases, isolating fixation to the metadiaphyseal portion of the bone can help simplify reconstruction.
Table. 1.
Metaphyseal-engaging stems (MES) | Diaphyseal-engaging stems (DES) | |
---|---|---|
Length | 30–75 mm | >75 mm |
Fixation | Generally cemented | Generally uncemented |
Advantages | Small adjustments possible in medial/lateral and anterior/posterior directions | Diaphyseal referencing to help with component alignment |
Avoids limb deformity or ipsilateral hardware | Easier to remove if revision required | |
Less end-of-stem pain | Applicable in patients with previous distal femoral or proximal tibial osteotomy | |
Disadvantages | Difficult to remove, can lead to more bone loss | End-of-stem pain |
Decreased references for proper component alignment | Without offset options can force articular components into suboptimal position | |
Risk of periprosthetic fracture with canal preparation | ||
May not be applicable in setting of dysplasia or ipsilateral hardware |
Disadvantages of MES must also be considered when planning a revision TKA. In the revision setting, loss of articular bone can make component alignment difficult to gauge, a situation further complicated by the inability of a MES to reference the diaphysis for alignment. Furthermore, several authors have commented that removing a fully cemented stem in a re-revision often results in greater bone loss than uncemented DES [22–24].
Diaphyseal-engaging stems
Diaphyseal-engaging stems are generally uncemented and press-fit to the diaphysis. The articular component is often cemented to the cut surface of the metaphysis which is described as a hybrid fixation. This technique has been well described by Haas et al. among others where the articular and metaphyseal portions of the implant are cemented and the diaphyseal-engaging portion of the stem is uncemented [10]. These stems generally are a minimum of 75 mm in length and differ from shorter stems in several ways [25]. Longer stems are frequently slotted and made of titanium; both of these design features decrease stress at the stem tip in an effort to decrease end-of-stem pain.[19, 21] Longer stems with a length greater than 150 mm are available with curved or bent geometry to match the natural bows of the femur or tibia.
The length of a DES must be determined concurrently with the stem diameter. Longer stems that approach the isthmus of the bone will be narrower than wider stems that engage closer to the articular surface. No literature has clearly defined which is more important with regard to length vs. width; however, several principles have been determined which can help determine the ideal combination. Bistolfi recommended using a tibial stem no shorter than 75 mm when employing a rotating-platform hinge for rTKA [25]. A recent study by Gililland et al. suggested press-fit stem length is determined as the minimal length required to achieve 4 cm of diaphyseal fit [26•]. The ideal width of an uncemented stem has been described by the “canal-fill-ratio” (CFR), which is defined as the width of the stem divided by the width of the intramedullary canal. The authors recommended a minimal CFR of >0.85 to achieve a stable intramedullary fit [27].
There are several advantages of DES compared to a cemented MES (Table 1). Diaphyseal-engaging stems reference the diaphysis, which can be helpful for determining and achieving the appropriate component alignment in the revision setting. Appropriate component alignment is crucial to the long-term success of revision TKA [28]. Parsley et. al showed improved alignment with uncemented stems compared to cemented stems as shorter cemented stems tended to have varus malalignment [27]. Uncemented stems are generally easier to remove than a large cement mantle that can accompany cemented stems, whether short or long [22, 24]. A hybrid construct theoretically provides stress transfer throughout the bone with no detrimental impact to bone mineral density [29, 30]. Patients with a previous distal femoral or proximal tibial osteotomy often have canal-epiphyseal mismatch that can be better managed with diaphyseal referencing and modular implants. [31, 32]
There are also several disadvantages of longer stems that the surgeon must consider when planning a revision TKA. Historically, a major concern was the restriction of diaphyseal referencing to component placement. If the stem and articular portion of the construct were mated in a linear fashion, diaphyseal referencing may force the articular component into a less than optimal position. Using computer modeling, Gobba et al. demonstrated that a 120-mm tibial stem will force the tibial tray into an excessively valgus position, whereas a 200-mm tibial stem will often force the tray into a posteromedial position [33]. Modern revision TKA implants now have offset couplers between the articular and diaphyseal portions of the implant which improve alignment and reduce implant overhang [34]. Anterior/posterior femoral offset options are crucial for managing the flexion gap in the revision TKA. Any surgeon attempting revision with a DES should be fully aware of the offset and modular capabilities and limitations of their system [35].
Unfortunately, patients with diaphyseal bowing, deformity, or previous implants are still at risk of canal perforation or abutment regardless of modularity options. Patients with previous ipsilateral total hip arthroplasty also will have the femoral stems to consider. The meeting of a hip stem and a knee stem can lead to a stress riser between the two implants, and surgeons should be aware of this prior to implanting a DES [36]. As long-stem preparation requires reaming of the IM canal, there is a small risk of fracture. Cipriano et al. reported a 3 % fracture rate in 634 stemmed TKA which occurred more commonly on the tibia; as such, surgeons should be prepared to manage such a complication [37].
Clinical outcomes
Evidence suggesting an ideal stem length with regard to clinical outcome in rTKA is lacking. The outcomes of cemented compared to uncemented stems in rTKA have been more common. Both cemented and uncemented stems have shown excellent outcomes in various series. With regard to cemented stems, a recent series identified no revisions for aseptic loosening in a series of 58 rTKA with 30-mm cemented tibial stems and an average follow-up of 5 years [38•]. The authors noted that using tantalum cones within metaphyseal defects resulted in fewer radiolucent lines. A separate series by Meneghini et al. using cemented 30-mm stems and metaphyseal cones for rTKA also demonstrated excellent outcomes [39]. These recent series reinforce that appropriate metaphyseal reconstruction with a cemented stem can produce satisfactory outcomes.
Similarly, hybrid fixation with uncemented diaphyseal engaging stem has shown excellent outcomes and survivorship. In a classic article by Haas et al., the survivorship of a hybrid rTKA with both tibial and femoral stems was 84 % with a mean follow-up of 42 months.[10] More recently, a series by Sah et al. confirmed the previous series with 92 % survivorship at 5 years with no revisions for aseptic loosening.[35] In a comparative study of cemented vs. uncemented stems for aseptic rTKA, only 22 and 24 % of the cemented stems had 4 cm of diaphyseal fit whereas all uncemented stems had ≥4 cm of diaphyseal fit [26•]. Although stem length is not specifically delineated, it can be assumed that the cemented stems were shorter than the uncemented stems. Clinical and radiographic survivorship was not statistically different. A similar study comparing 102 cemented vs. 126 uncemented stems for a two-stage infection revision found similar survivorship, reinfection, and clinical outcomes between the two techniques at an average of 52 months of follow-up. However, cemented stems were significantly more likely to have radiographic loosening compared to uncemented stems (32 vs. 17 %, respectively, p = 0.006) [40•]. The authors suggested that the reamed diaphysis was a poor surface for cement interdigitation leading to higher rates of radiographic lucency. In summary, survivorship and clinical outcomes of cemented vs. uncemented stems are similar, and the relatively low-quality evidence available does not suggest superiority of one technique.
The role of metaphyseal fixation
While stem length continues to be debated, there appears to be a strong trend in the recent literature highlighting the importance of metaphyseal fixation for reconstruction survivorship [38•, 39]. The current generation of revision TKA implants improved on earlier generations by addition of ingrowth metaphyseal sleeves and porous metal cones for metaphyseal reconstruction. Previously, the predominant form of metaphyseal reconstruction was bulk allograft, but the high rate of resorption with large allografts led to the development of modern sleeves and cones [41].
The recent studies by Meneghini, Gililland, Edwards, and others noted excellent short- to mid-term outcomes using porous metal metaphyseal components as part of the reconstruction [26•, 39, 40•]. Modern revision TKA should focus on not only articular reconstruction mated to stems but also include careful evaluation of the metaphysis. Previous concerns that metaphyseal reconstruction with porous metal components may hinder press-fit stem and articular component placement has not been supported in the literature as a CFR > 0.85 is reliably achieved regardless of the use of metaphyseal cones [42].
Authors’ preferred technique
At our institution, we prefer to use DES for the majority of revision TKA. Long-leg standing films are used to perform appropriate pre-operative planning and to assess for ipsilateral hardware, diaphyseal bowing, or other deformity which would preclude the use of a DES. Once confident that a DES is appropriate for the patient, a press-fit modular system utilizing titanium, slotted, bullet-tipped stems is used to minimize stress at the end of the construct. Stems are reamed line to line until good cortical chatter is obtained. Stems shorter than 80 mm are not used for diaphyseal engagement. Metaphyseal reconstruction is accomplished with porous metaphyseal sleeves to create a construct with broad bony engagement. At implantation, the articular implant and the modular junction of the stem and articular components are cemented, whereas care is taken to keep all cement off the porous ingrowth surface of the metaphyseal sleeve.
In the event a patient has an ipsilateral total hip replacement or deformity not amenable to a DES, a cemented, solid metaphyseal-engaging stem 35–75 mm in length is used for metaphyseal reconstruction. The cement is hand packed and pressurized to achieve a robust cement mantle within the metaphysis. If the stem extends into the diaphysis or no bone exists to confine the cement, a restrictor is placed to improve the cement mantle and prevent cement from extruding down the medullary canal.
Conclusions
Stems are an invaluable tool for revision knee arthroplasty and have been shown to substantially increase the mechanical stability of rTKA. Stem length should be tailored both to the patient as well the intended fixation strategy as decided by the surgeon. The optimal stem length is the one that achieves a mechanically sound construct while preserving as much native bone as possible. The literature review we completed failed to identify an “ideal” length, and it is unlikely that an ideal length will be described. Revision TKA requires patient-specific tailoring of the reconstruction strategy to match the patient’s dimensions, bone loss, and constraint requirements. We feel that it is helpful to divide revision TKA stems into metaphyseal-engaging stems and diaphyseal-engaging stems as this guides the fixation strategy for the revision construct.
Acknowledgments
Compliance with Ethics Guidelines
ᅟ
Conflict of Interest
Dr. Patel and Dr. Barlow have no conflicts of interest. Dr. Ranawat reports personal fees from DePuy, Stryker, Convatec, and ConforMIS in addition to grants and personal fees from Ceramtec.
Human and Animal Rights and Informed Consent
This article does not contain any studies with human or animal subjects performed by any of the authors.
Footnotes
This article is part of the Topical Collection on Revision Knee Arthroplasty
Contributor Information
Anay Rajendra Patel, Phone: 312-513-1309, Email: AnayRPatel@gmail.com.
Brian Barlow, Phone: 610-653-8833, Email: BarlowB@HSS.edu.
Amar S. Ranawat, Phone: 646-797-8700, Email: RanawatAmar@HSS.edu
References
Papers of particular interest, published recently, have been highlighted as: • Of importance
- 1.Bertin KC. Tibial component fixation in total knee arthroplasty: a comparison of pegged and stemmed designs. J Arthroplast. 2007;22(5):670. doi: 10.1016/j.arth.2006.07.004. [DOI] [PubMed] [Google Scholar]
- 2.Rawlinson JJ, Peters LE, Campbell DA, Windsor R, Wright TM, Bartel DL. Cancellous bone strains indicate efficacy of stem augmentation in constrained condylar knees. Clin Orthop Relat Res. 2005;440:107. doi: 10.1097/01.blo.0000187340.10003.68. [DOI] [PubMed] [Google Scholar]
- 3.Conlisk N, Gray H, Pankaj P, Howie C. The influence of stem length and fixation on initial femoral component stability in revision total knee replacement. Bone Joint Res. 2012;1(11):281. doi: 10.1302/2046-3758.111.2000107. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 4.Pérez-Blanca A, Prado M, Ezquerro F, Montañéz E, Espejo A. Addition of a short central extension to surface cemented tibial trays in primary TKA: an in vitro study of the effect on initial fixation stability and its relationship to supporting bone density. Clin Biomecha. 2008;23(4):483. doi: 10.1016/j.clinbiomech.2007.11.012. [DOI] [PubMed] [Google Scholar]
- 5.Riley LH., Jr The evolution of total knee arthroplasty. Clin Orthop Relat Res. 1976;120:7. [PubMed] [Google Scholar]
- 6.Jones GB. Total knee replacement-the Walldius hinge. Clin Orthop Relat Res. 1973;94:50. doi: 10.1097/00003086-197307000-00007. [DOI] [PubMed] [Google Scholar]
- 7.Phillips H, Taylor J. The Walldius hinge arthroplasty. J Bone Joint Surg Br. 1975;57(59). [PubMed]
- 8.Robinson RP. The early innovators of today’s resurfacing condylar knees. J Arthroplast. 2005;20:2. doi: 10.1016/j.arth.2004.11.002. [DOI] [PubMed] [Google Scholar]
- 9.Eftekhar N. Total knee-replacement arthroplasty. Results with the intramedullary adjustable total knee prosthesis. J Bone Joint Surg. 1983;65(3):293. [PubMed] [Google Scholar]
- 10.Haas SB, Insall JN, Montgomery W, Windsor RE. Revision total knee arthroplasty with use of modular components with stems inserted without cement. The Journal of Bone & Joint Surgery 77(11): 1700, 1995 . [DOI] [PubMed]
- 11.Jazrawi LM, Bai B, Kummer FJ, Hiebert R, Stuchin SA. The effect of stem modularity and mode of fixation on tibial component stability in revision total knee arthroplasty. J Arthroplast. 2001;16(6):759. doi: 10.1054/arth.2001.25507. [DOI] [PubMed] [Google Scholar]
- 12.Mabry TM, Hanssen AD. The role of stems and augments for bone loss in revision knee arthroplasty. J Arthroplast. 2007;22(4):56. doi: 10.1016/j.arth.2007.02.008. [DOI] [PubMed] [Google Scholar]
- 13.Mabry TM, Vessely MB, Schleck CD, Harmsen WS, Berry DJ. Revision total knee arthroplasty with modular cemented stems: long-term follow-up. J Arthroplast. 2007;22(6):100. doi: 10.1016/j.arth.2007.03.025. [DOI] [Google Scholar]
- 14.Haidukewych GJ, Hanssen A. Metaphyseal fixation in revision total knee arthroplasty: indications and techniques. J Am Acad Orthop Surg. 2011;19(6):311. doi: 10.5435/00124635-201106000-00001. [DOI] [PubMed] [Google Scholar]
- 15.Fehring TK, Odum S, Olekson C, Griffin WL, Mason JB, McCoy TH. Stem fixation in revision total knee arthroplasty: a comparative analysis. Clin Orthop Relat Res. 2003;416:217. doi: 10.1097/01.blo.0000093032.56370.4b. [DOI] [PubMed] [Google Scholar]
- 16.Kim Y-H, Kim J-S. Revision total knee arthroplasty with use of a constrained condylar knee prosthesis. J Bone Joint Surg. 2009;91(6):1440. doi: 10.2106/JBJS.H.00425. [DOI] [PubMed] [Google Scholar]
- 17.Murray PB, Rand JA, Hanssen AD. Cemented long-stem revision total knee arthroplasty. Clin Orthop Relat Res. 1994;309:116. [PubMed] [Google Scholar]
- 18.Whaley AL, Trousdale RT, Rand JA, Hanssen AD. Cemented long-stem revision total knee arthroplasty. J Arthroplast. 2003;18(5):592. doi: 10.1016/S0883-5403(03)00200-6. [DOI] [PubMed] [Google Scholar]
- 19.Barrack R, Stanley T, Burt M, Hopkins S. The effect of stem design on end of stem pain in revision TKA. J Arthroplast. 2004;19(2):256. doi: 10.1016/j.arth.2003.12.018. [DOI] [PubMed] [Google Scholar]
- 20.Barrack RL, Engh G, Rorabeck C, Sawhney J, Woolfrey M. Patient satisfaction and outcome after septic versus aseptic revision total knee arthroplasty. J Arthroplast. 2000;15(8):990. doi: 10.1054/arth.2000.16504. [DOI] [PubMed] [Google Scholar]
- 21.Barrack RL, Rorabeck C, Burt M, Sawhney J. Pain at the end of the stem after revision total knee arthroplasty. Clin Orthop Relat Res. 1999;367:216. [PubMed] [Google Scholar]
- 22.Shannon BD, Klassen JF, Rand JA, Berry DJ, Trousdale RT. Revision total knee arthroplasty with cemented components and uncemented intramedullary stems. J Arthroplast. 2003;18:27. doi: 10.1016/S0883-5403(03)00301-2. [DOI] [PubMed] [Google Scholar]
- 23.Whiteside L. Cementless fixation issues in revision total knee arthroplasty. Instr Course Lect. 1998;48:177. [PubMed] [Google Scholar]
- 24.Elia EA, Lotke PA. Results of revision total knee arthroplasty associated with significant bone loss. Clin Orthop Relat Res. 1991;271:114. [PubMed] [Google Scholar]
- 25.Bistolfi A, Massazza G, Rosso F, Crova M. Rotating-hinge total knee for revision total knee arthroplasty. Orthopedics. 2012;35(3):185. doi: 10.3928/01477447-20120222-34. [DOI] [PubMed] [Google Scholar]
- 26.•.Gililland JM, Gaffney CJ, Odum SM, Fehring TK, Peters CL, Beaver WB. Clinical & radiographic outcomes of cemented vs. diaphyseal engaging cementless stems in aseptic revision TKA. J Arthroplasty. 2014;29(9):224. doi: 10.1016/j.arth.2014.03.049. [DOI] [PubMed] [Google Scholar]
- 27.Parsley BS, Sugano N, Bertolusso R, Conditt MA. Mechanical alignment of tibial stems in revision total knee arthroplasty. J Arthroplast. 2003;18:33. doi: 10.1016/S0883-5403(03)00302-4. [DOI] [PubMed] [Google Scholar]
- 28.Nakasone CK, Abdeen A, Khachatourians AG, Sugimori T, Vince KG. Component alignment in revision total knee arthroplasty using diaphyseal engaging modular offset press-fit stems. J Arthroplast. 2008;23(8):1178. doi: 10.1016/j.arth.2007.10.002. [DOI] [PubMed] [Google Scholar]
- 29.Skwara A, Figiel J, Knott T, Paletta J, Fuchs-Winkelmann S, Tibesku C. Primary stability of tibial components in TKA: in vitro comparison of two cementing techniques. Knee Surgery, Sports Traumatology, Arthroscopy 17(10): 1199, 2009 [DOI] [PubMed]
- 30.Sathappan SS, Pang H-N, Manoj A, Ashwin T, Satku K. Does stress shielding occur with the use of long-stem prosthesis in total knee arthroplasty? Knee Surgery, Sports Traumatology, Arthroscopy. 2009;17(2):179. doi: 10.1007/s00167-008-0649-0. [DOI] [PubMed] [Google Scholar]
- 31.Kawano T, Miura H, Nagamine R, Urabe K, Matsuda S, Mawatari T, et al. Alignment in total knee arthroplasty following failed high tibial osteotomy. J knee Surg. 2003;16(3):168. [PubMed] [Google Scholar]
- 32.Nagamine R, Miura H, Bravo CV, Urabe K, Matsuda S, Miyanishi K, et al. Anatomic variations should be considered in total knee arthroplasty. J Orthop Sci. 2000;5(3):232. doi: 10.1007/s007760050157. [DOI] [PubMed] [Google Scholar]
- 33.Gobba MS, Chan N, Patel R, Noble PC, Incavo SJ. Tibial stems in revision total knee arthroplasty: is there an anatomic conflict? The Journal of arthroplasty, 2015 [DOI] [PubMed]
- 34.Scuderi GR. Revision total knee arthroplasty: how much constraint is enough? Clin Orthop Relat Res. 2001;392:300. doi: 10.1097/00003086-200111000-00039. [DOI] [PubMed] [Google Scholar]
- 35.Sah AP, Shukla S, Della Valle CJ, Rosenberg AG, Paprosky WG. Modified hybrid stem fixation in revision TKA is durable at 2 to 10 years. Clinical Orthopaedics and Related Research. 2011;469(3):839. doi: 10.1007/s11999-010-1569-0. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 36.Lehmann W, Rupprecht M, Nuechtern J, Melzner D, Sellenschloh K, Kolb J, et al. What is the risk of stress risers for interprosthetic fractures of the femur? A biomechanical analysis. Int Orthopaedics. 2012;36(12):2441. doi: 10.1007/s00264-012-1697-0. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 37.Cipriano CA, Brown NM, Della Valle CJ, Moric M, Sporer SM. Intra-operative periprosthetic fractures associated with press fit stems in revision total knee arthroplasty: incidence, management, and outcomes. J Arthroplast. 2013;28(8):1310. doi: 10.1016/j.arth.2012.10.003. [DOI] [PubMed] [Google Scholar]
- 38.•.Lachiewicz PF, Soileau ESA. 30-mm cemented stem extension provides adequate fixation of the tibial component in revision knee arthroplasty. Clin Orthopaedics Relat Res. 2015;473(1):185. doi: 10.1007/s11999-014-3529-6. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 39.Meneghini RM, Lewallen DG, Hanssen AD. Use of porous tantalum metaphyseal cones for severe tibial bone loss during revision total knee replacement. J Bone Joint Surg Am Volume. 2008;90(1):78. doi: 10.2106/JBJS.F.01495. [DOI] [PubMed] [Google Scholar]
- 40.•.Edwards PK, Fehring TK, Hamilton WG, Perricelli B, Beaver WB, Odum SM. Are cementless stems more durable than cemented stems in two-stage revisions of infected total knee arthroplasties? Clin Orthopaedics Related Res. 2014;472(1):206. doi: 10.1007/s11999-013-3139-8. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 41.Van Loon C, de Waal MM, Buma P, Verdonschot N, Veth R. Femoral bone loss in total knee arthroplasty. Rev Acta Orthopaedica Belgica. 1999;65(2):154. [PubMed] [Google Scholar]
- 42.Bédard M, Cabrejo-Jones K, Angers M, Pelletier-Roy R, Pelet S. The effect of porous tantalum cones on mechanical alignment and canal-fill ratio in revision total knee arthroplasty performed with uncemented stems. The Journal of arthroplasty, 2015 [DOI] [PubMed]