Quantitative assessment of bio-aerosols contamination in indoor air of University dormitory rooms

Samuel Fekadu Hayleeyesus (1),*, Amanuel Ejeso (1), Fikirte Aklilu Derseh (2)
PMCID: PMC4633188  PMID: 26609289

Abstract

Objectives

The purpose of this study is to provide insight into how students are exposed to indoor bio-aerosols in the dormitory rooms and to figure out the major possible factors that govern the contamination levels.

Methodology

The Bio-aerosols concentration level of indoor air of thirty dormitory rooms of Jimma University was determined by taking 120 samples. Passive air sampling technique; the settle plate method using open Petri-dishes containing different culture media was employed to collect sample twice daily.

Results

The range of bio-aerosols contamination detected in the dormitory rooms was 511–9960 CFU/m3 for bacterial and 531–6568 CFU/m3 for fungi. Based on the criteria stated by WHO expert group, from the total 120 samples 95 of the samples were above the recommended level. The statistical analysis showed that, occupancy were significantly affected the concentrations of bacteria that were measured in all dormitory rooms at 6:00 am sampling time (p-value=0.000) and also the concentrations of bacteria that were measured in all dormitory rooms were significantly different to each other (p-value=0.013) as of their significance difference in occupancy (p-value=0.000). Moreover, there were a significant different on the contamination level of bacteria at 6:00 am and 7:00 pm sampling time (p=0.015), whereas there is no significant difference for fungi contamination level for two sampling times (p= 0.674).

Conclusion

There is excessive bio-aerosols contaminant in indoor air of dormitory rooms of Jimma University and human occupancy produces a marked concentration increase of bacterial contamination levels and most fungi species present into the rooms air of Jimma University dormitory were not human-borne.

Keywords: indoor air, bio-aerosol, bacteria, fungi, sedimentation technique, dormitory room

Introduction

Bio-aerosols in the indoor environment are the presumed or confirmed causative agents of various infectious diseases, and their components are associated to the development and exacerbation of chronic respiratory illness including asthma. (15) In many epidemiological studies a link has been seen between mold damage or moisture in indoor environments and increased risk of upper respiratory symptoms ranging from cough to shortness of breath. (5,6,7) Moreover, the WHO report based on the review of several epidemiological studies indicated that, there is sufficient evidence of the link between indoor dampness-related factors and a wide range of respiratory health effects, including asthma development, asthma exacerbation, current asthma, respiratory infections, upper respiratory tract symptoms, cough, wheeze and dyspnoea. (8) In general, there are three major groups of diseases linked with bio-aerosols exposure are infectious diseases, respiratory diseases and cancer. (2) So, it’s crucial to control bio-aerosols contamination level and maintaining a clean and healthy indoor environment in order to sustain the health of the occupants.

Mostly, indoor air quality is only a problem when building occupants report symptoms. However, bio-aerosols contamination continues to pose a significant threat to health worldwide. (8, 9) Among different indoor air pollutants, bio-aerosols are one of the important pollutants that seek more attention, that contribute about 5–34% of indoor air pollution. (10, 11) As of these, assessments of bio-aerosols contamination level in different indoor environments have gained more attention in the recent decades. (12, 20)

Several studies have been indicated that the housing conditions, the human activities and life style of occupants is thought to be the principal factor contributing to the buildup and spread of bio-aerosols contamination in indoor environment. (10,12,19,21) Other important sources of biological particulate matter may be human oral and respiratory fluid emitted via talking, sneezing, coughing, and breathing (22,23) or the direct shedding of skin related micro biota. (24, 25, 26)

Thus bio-aerosols concentration level in indoor air is an important criterion that must be taken into account when indoor environments are designed, operated and occupied to reduce human exposure to bio-aerosols that cause adverse health effects. Therefore, the purpose of this study is to provide insight into how students are exposed to indoor bio-aerosols from the environment and other humans in the dormitory rooms and to figure out the major possible factors that govern the contamination levels.

Methods and Materials

Study Area

Jimma University (JU) is a public higher educational institution established in December 1999 by the amalgamation of Jimma College of Agriculture (founded in 1952), and Jimma Institute of Health Sciences (established in 1983). The University is located in Jimma town, which is 345km south west of Addis Ababa, Ethiopia. It has an altitude of 1740–1760m above sea level and its temperature range from maximum 25–30°C and minimum 7–20°C and annual rain fall range from 1200–2000mm. In this University, currently a total of 28583 students are enrolled in-campus programs. The University provides dormitory services, mostly for the regular undergraduate students. Students are assigned in different number to reside together according to the size of the rooms. Usually range from 6 to 26 students per each dorm room.

The study was conducted from April to May 2014 by selecting seven main dormitory buildings for sampling. From all selected dormitory buildings (Namely: Abajifar, Abdisa, Comoros, Sawa, Sheraton, Bladen and Whitehouse) 30 dorm rooms have been picked by simple random sampling from each buildings after proportionally allocated.

Sampling procedure

Sampling method following the standard 1/1/1 schedule (Petri dish must be left open to the air for 1 h, 1 m above the floor, 1 m from the wall). (27) Bacteria and fungi were collected on 2% nutrient agar and 4% sabouroad agar respectively. Moreover, samples were collected twice a day at 6:00 am and 7:00 pm. At 6:00 am by assuming that most of the students remain in their dormitory room after spending the whole night in their rooms and at 7:00 pm by assuming that most of students spent their day time outside their dormitory for learning activities and remain there until 7:00 pm. So, after collecting the sample at specified times, were taken to the laboratory (Department of Environmental Health Science and Technology, Jimma University) and incubated at 37°C for 24 hours for bacteria and at 25°C for 3 days for fungi.

Once colony forming units (CFU) were enumerated, colony forming units per cubic meter (CFU /m3) were determined, taking into account the following equation described by Omeliansky. (28, 29)

N=5a*104(bt)-1,

Where:

  • N: microbial CFU/m3 of indoor air;

  • a: number of colonies per Petri dish;

  • b: dish surface, cm2;

  • t: exposure time, minutes.

In line with bio-aerosols sample collection, data on: the number of students in each room during sampling, temperature and relative humidity were collected.

Statistical Analysis

SPSS Statistics 16.0 software was applied to determine the likelihood of statistically significant differences between the concentrations of bacteria and fungi measured at different sampling rooms with occupancy and other environmental factors like temperature and relative humidity.

Results

The indoor air bio-aerosols loads of thirty dormitory rooms of Jimma University were determined by taking 120 samples. The results of the research into the concentration, concentration range, arithmetic mean and standard deviation of bio-aerosols present in the investigated dormitory rooms and environmental parameters that have been measured are presented in Table 1 and 2.

Table 1.

The bacteria and fungi concentration levels, the number of occupants, temperature, relative humidity of student dormitory rooms of Jimma University at each sampling time

No. Examined dormitories Bacteria (CFU/m3) in both sampling time Fungi (CFU/m3) in both sampling time Number of occupants during sampling time Relative humidity during sampling time Temperature during sampling times (°C)
6:00 am 7:00 pm 6:00 am 7:00 pm 6:00 am 7:00 pm 6:00 am 7:00 pm 6:00 am 7:00 pm
1 Sawa 01 9960 4010 4744 1825 25 2 42 54 31 26
2 Sawa 02 3670 2123 929 1559 22 3 47 59 29 25
3 Sawa 03 1599 1284 1062 2787 21 - 45 53 29 27
4 Sawa 04 5059 2674 2090 1360 23 1 54 61 26 24
5 Sawa 05 1913 1638 4611 1990 22 - 56 51 26 27
6 Comoros 01 2228 1900 2488 1626 21 - 46 54 29 26
7 Comoros 02 2516 2149 6568 5042 24 4 44 51 30 27
8 Comoros 03 4456 3670 962 1825 23 1 48 43 28 30
9 Comoros 04 3748 2713 3981 2787 21 - 49 57 28 25
10 Comoros 05 3172 2569 3782 3467 22 1 42 61 31 24
11 Sheraton 01 1258 747 730 1294 6 - 45 57 29 25
12 Sheraton 02 1180 865 531 1128 5 - 48 54 28 26
13 Sheraton 03 996 813 813 746 6 1 65 54 23 26
14 Abajifar 01 1153 839 1460 1758 4 1 54 57 26 25
15 Abajifar 02 747 590 1261 1692 4 - 46 57 29 25
16 Abajifar 03 891 511 1576 1825 6 2 44 51 30 27
17 Abajifar 04 1442 1127 1161 962 6 1 52 65 27 23
18 Abdisa 01 996 983 763 1028 6 - 55 57 26 25
19 Abdisa 02 813 629 929 730 5 1 51 54 27 26
20 Abdisa 03 1389 1245 1062 1692 6 - 44 57 30 25
21 Bladen 01 2202 852 1825 1990 11 1 42 54 30 26
22 Bladen 02 4194 3145 1725 1493 12 1 45 48 29 28
23 Bladen 03 2018 1389 1576 1742 10 - 43 54 30 26
24 Bladen 04 1494 1258 3400 2040 12 - 57 48 25 28
25 Bladen 05 1992 1415 1526 1178 11 1 54 48 26 28
26 White house 01 2136 2569 2488 3981 12 - 48 65 28 23
27 White house 02 1546 734 3483 6403 12 - 54 57 26 25
28 White house 03 1992 1415 4313 2919 10 - 50 51 28 27
29 White house 04 1678 2307 896 1758 11 - 53 61 27 24
30 White house 05 1900 1389 1062 1310 11 - 57 51 25 27

Table 2.

Statistical summary of bio-aerosols concentration, temperature and relative humidity in student dormitory rooms of Jimma University

Variables N Minimum Maximum Mean Std. Deviation
Bacteria (CFU/m3) at 6:00 am 30 747 9960 2345 1831
Bacteria (CFU/m3) at 7:00 pm 30 511 4010 1652 945
Fungi (CFU/m3) at 6:00 am 30 531 6568 2127 1531
Fungi (CFU/m3) at 7:00 pm 30 730 6403 2065 1256
Temperature at 6:00 am 30 23 31 28 2
Temperature at 7:00 pm 30 23 30 26 2
Relative Humidity at 6:00 am 30 42 65 49 6
Relative Humidity at 7 pm 30 43 65 55 5
Valid N (listwise) 30

As can be calculated from Table 1, during early morning sampling (6:00 am) in 70% of dormitory rooms the bacterial concentrations were higher than the fungi ones, but in the afternoon sampling (7:00 pm) the bacterial concentrations higher only in 53% of dormitory rooms. And from the total 120 samples, 95 of the samples (79%) were a microbial load above 1000 CFU/m3.

The highest level of bio-aerosols contamination was detected in the dormitory rooms that found in Sawa and Comoros buildings at 6:00 am sampling time, which are bacterial 9960 CFU/m3 (Sawa 01) and fungi 6568 CFU/m3 (Comoros 02) respectively. The lowest bacterial contamination was measured in Abajifar dormitory building (Abajifar 03) at 7:00 pm sampling time, which is 511 CFU/m3, while the lowest fungi colony forming unit per m3 air was recorded at 6:00 am in Sheraton dormitory building (Sheraton 02), which is 531 CFU/m3.

During at 6:00 am sampling time, the average number of occupants varies from 21 to 26 in the dormitory rooms in which 26 students assigned to live, namely; Sawa and Comoros, where as in the dormitory rooms in which 6 students assigned to live, namely; Sheraten, Abdisa and Abjifar varies from 4 to 6 and in the dormitory rooms in which 12 students assigned to live, namely; Bladen and Whitehouse, the number of students varies from 10 to 12.

All examined dormitory rooms did not have HVAC (heating, ventilation, and air conditioning) systems. The temperature and relative humidity during sampling ranged from 23 to 31°C and 42 to 65% respectively (Table 2). As can be seen in Table 3 the Pearson correlation test indicated that neither the temperature nor the relative humidity in the selected dormitory rooms had a statistically significant effect on the measured bio-aerosols concentrations with p-value= 0.063 and 0.246 for bacteria and fungi respectively at 6:00 am sampling and p-value= 0.528 and 0.622 for bacteria and fungi respectively at 7:00 pm sampling.

Table 3.

Correlation coefficient matrix: - bacteria, fungi, temperature, relative humidity, and Occupancy in both sampling times (6:00 am and 7:0 pm) of Jimma University student dormitory rooms.

Variables 1 2 3 4 5 6 7 8 9
Bacteria 6:00 am -
Bacteria 7:00 pm 0.849**
Fungi 6:00 am 0.392* 0.372*
Fungi 7:00 pm 0.043 0.130 0.646**
Temperature 6:00 am 0.344 0.292 0.218 0.201
Temperature 7:00 pm 0.100 0.120 0.096 −0.094 −0.050
Relative Humidity at 6:00 am −0.311 −0.263 −0.154 −0.197 −0.986** 0.021
Relative Humidity at 7:00 pm −0.079 −0.071 −0.119 0.100 0.060 −0.991** −0.033
Number of occupant at 6:00 am 0.684** 0.749** 0.577** 0.344 0.279 0.185 −0.243 −0.131
Number of occupant at 7:00 pm 0.259 0.196 0.431* 0.301 0.358 0.095 −0.300 −0.077 0.393*
**

Correlation is significant at the 0.01 level (2-tailed).

*

Correlation is significant at the 0.05 level (2-tailed).

Discussion

The excessive bio-aerosols contaminants in indoor air can cause significant health effects including those collectively known as sick building syndrome. (5, 6, 7, 30, 31, 32) Even though, there is no standard at international level to determine whether an indoor environment is contaminated or not, it has been recommended that environments with a microbial load above 1000 CFU/m3 should be labeled as contaminated. (9) Evaluation of the air quality in the selected dormitory rooms of Jimma University, from the total 120 samples 95 of the samples were above this recommended level, which is 79%. Other research work also considered that total microbial load (bacteria and fungi combined) should not exceed 750 CFU/m3, higher than this the environment is labeled as contaminated (33) and still other authors consider that 300 CFU/m3 and 750 CFU/m3 should be the limit for fungi and bacteria respectively. (34, 35)

When comparing indoor air environments of dormitory rooms of Jimma University, it can be seen that the rooms which found in the Sawa and Comoros dormitory buildings, have the highest bio-aerosols load and the rooms which found in Abajifar and Sheraton dormitory buildings, have the lowest load of bio-aerosols. These can be mainly explained by the variation of occupancy during sampling times. The statistical analysis showed that, occupancy were significantly affected the concentrations of bacteria that were measured in all dormitory rooms at 6:00 am sampling time (p-value= 0.000). But at 7:00 pm sampling time, there is no statistical significance between bacterial contamination levels with occupancy (p-value=0.298). These might be due to that, at 6:00 am sampling time, the sample is collected while most of the students were on the bed and there is no much air exchange with the outdoor air as of the doors and window were closed throughout the night. But at 7:00 pm sampling time, compare to 6:00 am sampling time there is high air exchange with the outdoor as of the windows left open throughout the daylight time starting from 8:00 am till around 8:00 pm., beside these, only few students were in the dormitory rooms, even, more than 50% of the dormitory rooms were no students at a time of sampling. In addition to these, there were a significant different on the contamination level of bacteria at 6:00 am and 7:00 pm sampling time (p=0.015), whereas there is no significant difference for fungi contamination level for two sampling times (p= 0.674). Moreover, as shown in Table 1, during early morning sampling (6:00 am) in 70% of dormitory rooms the bacterial concentrations were higher than the fungi ones. But, during 7:00 pm sampling time this figure decreased to 53%. This difference might be due to the fact that, at 6:00 am sampling there was higher occupancy than 7:00 pm sampling.

The concentrations of bacteria that were measured in all dormitory rooms were significantly different to each other (p-value= 0.013) as of their significance difference in occupancy (p-value=0.000). And also the concentrations of fungi that were measured in all dormitory rooms were significantly different to each other (p-value=0.034). This variation could be explained as of their variation in ventilation conditions and dampness situation of the building that might create favorable condition for the fungi contamination. There are numerous studies reported worldwide on moisture damage and subsequent mold contamination in different indoor environments. (36, 37, 38, 39)

Therefore, this study revealed that, human occupancy produces a significant concentration increase of bacterial contamination levels into the rooms air of student dormitory and most fungi species present into the rooms air were not human-borne as it has been discussed above statistical analysis showed the occupancy hadn’t have a significant effect on fungi contamination. These observations were in agreement with similar studies in indoor air. (12, 20)Moreover, the Pearson correlation test indicated that, there were no statistically significant correlations between bio-aerosols concentrations and the temperature or the relative humidity of the sample sites. These strengthen that, the principal factors contributing to the buildup and spread of bio-aerosols contamination in indoor environment of Jimma University student dormitory rooms were occupancy took the lion share for the bacteria contamination and other moisture containing organic materials might be the principal factor for fungi contamination.

Conclusion

There is excessive bio-aerosols contaminant in indoor air of dormitory rooms of Jimma University and human occupancy produces a marked concentration increase of bacterial contamination levels and most fungi species present into the rooms air of Jimma University dormitory were not human-borne.

Acknowledgements

The authors are grateful to the Department of Environmental Health Science and Technology for providing lab facilities and to all students of studied dorms rooms for their willingness to access the sampling points.

References

  • 1.Falkinham JO. Surrounded by mycobacteria: nontuberculous mycobacteria in the human environment. Journal of Applied Microbiology. 2009;107:356–367. doi: 10.1111/j.1365-2672.2009.04161.x. [DOI] [PubMed] [Google Scholar]
  • 2.Douwes J, Thorne P, Pearce N, Heederik D. Bio-aerosol health effects and exposure assessment: Progress and prospects. Applied Occupational Hygiene. 2003;47:187–200. doi: 10.1093/annhyg/meg032. [DOI] [PubMed] [Google Scholar]
  • 3.Li Y, Leung GM, Tang JW, Yang X, Chao CYH, Lin JZ, et al. Role of ventilation in airborne transmission of infectious agents in the built environment-a multidisciplinary systematic review. Indoor Air. 2007;17:2–18. doi: 10.1111/j.1600-0668.2006.00445.x. [DOI] [PubMed] [Google Scholar]
  • 4.Peccia J, Milton DK, Reponen T, Hill J. A role for environmental engineering and science in preventing bioaerosol-related disease. Environmental Science and Technology. 2008;42:4631–4637. doi: 10.1021/es087179e. [DOI] [PubMed] [Google Scholar]
  • 5.Dharmage S, Bailey M, Raven J, Mitakakis T, Cheng A, Guest D, et al. Current indoor allergen levels of fungi and cats, but not house dust mites, influence allergy and asthma in adults with high dust mite exposure. American Journal of Respiratory and Critical Care Medicine. 2001;164:65–71. doi: 10.1164/ajrccm.164.1.9911066. [DOI] [PubMed] [Google Scholar]
  • 6.IOM (Institute of Medicine, National Academics of Science) Damp Indoor Spaces and Health Committee Report. The National Academies Press; Washington, DC, USA: 2004. [PubMed] [Google Scholar]
  • 7.Dales RD, Burnett R, Zwanenburg H. Adverse health effects among adults exposed to home dampness and moulds. American Review of Respiratory Disease. 1991;143:505–9. doi: 10.1164/ajrccm/143.3.505. [DOI] [PubMed] [Google Scholar]
  • 8.World Health Organization. WHO guidelines for indoor air quality: dampness and mould. Copenhagen Denmark: 2009. [PubMed] [Google Scholar]
  • 9.Nevalainen A, Morawaska L, editors. Biological agents in indoor environments. Assessment of health risks, Work conducted by a WHO Expert Group between 2000–2003. http://www.ilaqh.qut.edu.au/Misc/BIOLOGICALAGENTS, 2009.pdf.
  • 10. [Accessed July 10, 2014]. Available at: http://www.airqualitydirect.com/bioaerosols.htm.
  • 11. [Accessed July 10, 2014]. Available at: http://www.pollutionissues.com/Ho-Li/Indoor-Air-Pollution.html.
  • 12.Samuel FH, Abayneh MM. Microbiological quality of indoor air in university libraries. Asian Pac J Trop Biomed. 2014;4:S312–S317. doi: 10.12980/APJTB.4.2014C807. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 13.La-Serna I, DO-Pazo A, Aira MJ. Airborne fungal spores in the Campus of Anchieta. Grana. 2002;41:119–123. [Google Scholar]
  • 14.Sarica S, Asan A, Otkun MT, Ture M. Monitoring indoor airborne fungi and bacteria in the different areas of Trakya University Hospital, Edirne, Turkey. Indoor and Built Environment. 2002;1:285–292. [Google Scholar]
  • 15.Peterman TK, Jalongo MR, Lin Q. The effects of molds and fungi on young children’s health: Families’ and educators’ roles in maintaining indoor air quality. Early Childhood Education Journal. 2002;30:21–26. [Google Scholar]
  • 16.Yazicioglu M, Asan A, Ones U, Vatansever U, Sen B, Ture M, et al. Indoor air fungal spores and home characteristics in asthmatic children from Edirne Region of Turkey. Allergologiaet Immunopathologia. 2004;32:197–203. doi: 10.1016/s0301-0546(04)79239-3. [DOI] [PubMed] [Google Scholar]
  • 17.Daisey JM, Angell WJ, Apte MG. Indoor air quality, ventilation and health symptoms in schools: an analysis of existing information. Indoor Air. 2003;13:53–64. doi: 10.1034/j.1600-0668.2003.00153.x. [DOI] [PubMed] [Google Scholar]
  • 18.Rojas TI, Martinez E, Gomez Y, Alvarado Y. Airborne spores of Aspergillus species in cultural institutions at Havana University. Grana. 2002;41:190–193. [Google Scholar]
  • 19.Kalogerakis N, Paschali D, Lekaditis V, Pantidou A, Eleftheriadis K, Lazaridis M. Indoor air quality - bioaerosol measurements in domestic and office premises. Journal of Aerosol Science. 2005;36:751–61. [Google Scholar]
  • 20.Soto T, García Murcia RM, Franco A, Vicente-Soler J, Cansado J, Gacto M. Indoor airborne microbial load in a Spanish university (University of Murcia, Spain) Anales de Biologia. 2009;31:109–115. [Google Scholar]
  • 21.Foarde K, Dulaney P, Cole E, VanOsdel D, Ensor D, Chang J. Assessment of fungal growth on ceiling tiles under environmentally characterized conditions. Indoor Air. 1993;4:357–362. [Google Scholar]
  • 22.Johnson GR, Morawska L. The mechanism of breath aerosol formation. Journal of Aerosol Medicine and Pulmonary Drug Delivery. 2009;22:229–237. doi: 10.1089/jamp.2008.0720. [DOI] [PubMed] [Google Scholar]
  • 23.Xie X, Li Y, Sun H, Liu L. Exhaled droplets due to talking and coughing. Journal of the Royal Society Interface. 2009;6:S703–S714. doi: 10.1098/rsif.2009.0388.focus. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 24.Noble WC, Habbema JDF, van Furth R, Smith I, de Raay C. Quantitative studies on the dispersal of skin bacteria into the air. Journal of Medical Microbiology. 1976;9:53–61. doi: 10.1099/00222615-9-1-53. [DOI] [PubMed] [Google Scholar]
  • 25.Mackintosh CA, Lidwell OM, Towers AG, Marples RR. The dimensions of skin fragments dispersed into the air during activity. Journal of Hygiene (London) 1978;81:471–479. doi: 10.1017/s0022172400025341. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 26.Fox K, Fox A, Elßner T, Feigley C, Salzberg D. MALDI-TOF mass spectrometry speciation of staphylococci and their discrimination from micrococci isolated from indoor air of schoolrooms. Journal of Environmental Monitoring. 2010;12:917–923. doi: 10.1039/b925250a. [DOI] [PubMed] [Google Scholar]
  • 27.Pasquarella C, Pitzurra O, Savino A. The index of microbial air contamination (review) J Hosp Infect. 2000;46:241–56. doi: 10.1053/jhin.2000.0820. [DOI] [PubMed] [Google Scholar]
  • 28.Borrego S, Guiamet P, Saravia SG, Batistinib P, Garciaa M, Lavinb P, Perdomoa I. The quality of air at archives and the biodeterioration of photographs. International Biodeterioration and Biodegradation. 2010;64:139–145. [Google Scholar]
  • 29.Gutarowska B. Metabolic activity of moulds as a factor of building materials Biodegradation. Polish Journal of Microbiology. 2010;59:119–124. [PubMed] [Google Scholar]
  • 30.Schwap CJ, Straus DC. The roles of penicillium and Aspergillus in sick building syndrome. Adv Appl Microbiol. 2004;55:215–238. doi: 10.1016/S0065-2164(04)55008-6. [DOI] [PubMed] [Google Scholar]
  • 31.Fracchia L, Pietronave S, Rinaldi M, Martinotti MG. The assessment of airborne bacterial contamination in three composting plants revealed site related biological hazard and seasonal variations. J Appl Microbiol. 2006;100:973–984. doi: 10.1111/j.1365-2672.2006.02846.x. [DOI] [PubMed] [Google Scholar]
  • 32.Gorny RL, Reponen T, Willeke K, Schmechel D, Robine E, Boissier M, Grinshpun SA. Fungal fragments as indoor air biocontaminants. Appl Environ Microbiol. 2002;68:3522–3531. doi: 10.1128/AEM.68.7.3522-3531.2002. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 33.Neto FRA, Siqueira LFG. Guidelines for indoor air quality in offices in Brazil. Proceedings of Healthy Buildings. 2000;4:549–553. [Google Scholar]
  • 34.Cappitelli F, Fermo P, Vecchi R, Piazzalunga A, Valli G, Zanardini E, et al. Chemical-physical and microbiological measurements for indoor air quality assessment at the ca’ granda historical archive, Milan (Italy) Water, Air, and Soil Pollution. 2009;201:109–120. [Google Scholar]
  • 35.Cappitelli F, Sorlini C. Paper and manuscripts. In: Mitchell R, McNamara CJ, editors. Cultural Heritage Microbiology: Studies in Conservation Science. ASM Press; Washington, DC, USA: 2010. pp. 45–59. [Google Scholar]
  • 36.Meklin T, Hyvärinen A, Toivola M, Reponen T, Koponen V, Husman T, et al. Effect of building frame and moisture damage on microbiological indoor air quality in school buildings. Am Ind Hyg Assoc J. 2003;64:108–116. doi: 10.1080/15428110308984800. [DOI] [PubMed] [Google Scholar]
  • 37.Hyvärinen A, Vahteristo M, Meklin T, Jantunen M, Nevalainen A. Temporal and spatial variation of fungal concentrations in indoor air. Aerosol Science and Technology. 2001;35:688–695. [Google Scholar]
  • 38.Klanova K. The concentrations of mixed populations of fungi in indoor air: rooms with and without mould problems; rooms with and without health complaints. Cent Eur J Pub Health. 2000;8:59–61. [PubMed] [Google Scholar]
  • 39.Ellringer PJ, Boone K, Hendrikson S. Building materials used in construction can affect indoor air fungal levels greatly. Am Ind Hyg Assoc J. 2000;61:895–899. doi: 10.1080/15298660008984603. [DOI] [PubMed] [Google Scholar]

Articles from International Journal of Health Sciences are provided here courtesy of Qassim University