Abstract
The use of hyperpolarized agents in magnetic resonance, such as 13C-labelled compounds, enables powerful new imaging and detection modalities that stem from a 10,000-fold boost in signal. A major challenge for the future of the hyperpolarization technique is the inherently short spin-relaxation times, typically <60 s for 13C liquid-state compounds, which limit the time that the signal remains boosted. Here we demonstrate that 1.1% natural abundance 13C spins in synthetic nanodiamond can be hyperpolarized at cryogenic and room temperature without the use of free radicals, and, owing to their solid-state environment, exhibit relaxation times exceeding 1 h. Combined with the already established applications of nanodiamonds in the life sciences as inexpensive fluorescent markers and non-cytotoxic substrates for gene and drug delivery, these results extend the theranostic capabilities of nanoscale diamonds into the domain of hyperpolarized magnetic resonance.
Hyperpolarized carbon nuclei are promising contrast agents for magnetic resonance imaging, but typically possess relaxation times below one minute. Here, the authors demonstrate cryogenic and room temperature hyperpolarization of 13C in synthetic nanodiamonds with relaxation times exceeding one hour.
Nanoparticles, having found use in the treatment of cancers1,2, the study of autoimmune diseases3 and cardiovascular affections4, are currently of interest as theranostic agents needed for the advent of personalized medicine5. These nanoscale systems are expected to integrate imaging, tracking and monitoring capabilities with targeted delivery of compounds to tumours, cellular functions and processes, or specific organs. Especially powerful is the modality established by combining high-resolution magnetic resonance imaging (MRI) with nanoparticles that have been hyperpolarized to act as contrast agents, as has been achieved recently using silicon compounds6,7.
Nanodiamonds (NDs) are well suited to act as theranostic platforms, having demonstrated an innate compatibility with biological environments and low toxicity in comparison with other nanoscale structures8,9. The readily modifiable surface, which is easily functionalized10, has enabled NDs to be conjugated to specific molecules11, opening a plethora of biomedical applications that include pharmaceutical delivery9,12,13,14 and intracellular tracking15 based on the unique optical properties of defects in the diamond lattice11. A particular defect, the nitrogen vacancy colour centre, has also established a sensitive means of detecting minute magnetic fields on the nanoscale using methods pioneered in controlling quantum devices16,17,18,19,20,21,22. Beyond luminescence-based techniques, however, approaches to non-invasively detect and image diamond nanoparticles in vivo have to date, been lacking.
Standard MRI modalities (operating at few Tesla magnetic fields) are not well suited for resolving weak concentrations of ND in vivo since diamond is a dilute spin system (1.1% 13C) and carbon has a small gyromagnetic ratio. This limitation can, in principle, be overcome using hyperpolarization techniques23, which can result in a 10,000-fold boost in signal over that from typical thermal polarization conditions24,25. Hyperpolarized molecular compounds such as [1-13C]pyruvate, for example, have recently been used to study tumour metabolism in humans by first transferring electron spin polarization to 13C nuclei at cryogenic temperatures26.
In these liquid-state compounds, hyperpolarized 13C spins typically relax to thermal equilibrium on timescales T1 <60 s (ref. 23). In contrast, bulk, high-purity diamond can exhibit 13C T1 times of many hours27 and recent work using optical techniques to manipulate nitrogen vacancy centres28,29,30,31 has produced significant polarization in large single-crystal samples. The challenge therefore is to maintain these long spin lifetimes even when diamond is produced in nanoparticle form and in sufficient quantities to be of clinical relevance. Addressing this challenge requires a detailed understanding of particle size effects, the structure of internal crystal defects, contaminants and spin-relaxation channels that arise from the nanoparticle surface32,33,34,35. Balancing these constraints, the hyperpolarization mechanism also requires the presence of unpaired electrons which in the case of liquid 13C compounds, are typically added to the agent in the form of organic free radicals.
In the present work, we extend the opportunity for deploying ND in life-science applications by demonstrating its suitability as a magnetic resonance marker and contrast agent for MRI. Using electron spin resonance (ESR), we observe that inexpensive commercially available ND, produced via the high-pressure high-temperature process, surprisingly exhibits a suitable balance of paramagnetic centres from defects and surface dangling bonds to allow both hyperpolarization and the preservation of long spin-relaxation times. In comparison with previous results on detonation ND32,33, the 13C relaxation data reported here exhibit a 1,000-fold extension in T1 together with signal enhancements that compare favourably with hyperpolarized 13C liquid-state compounds. Particle size is found to significantly affect both the relaxation time and amount of achievable hyperpolarization, opening the possibility of selectively detecting NDs of a particular size distribution. In addition to showing significant hyperpolarization at T=4 K, we demonstrate that a sizeable signal enhancement is also possible at liquid nitrogen (77 K) and room temperature using dynamic nuclear polarization (DNP), alleviating the need for expensive liquid helium and potentially enabling new in vivo modalities. Finally, we examine the spin dynamics of the ND core and its surface using hyperpolarized states to resolve new phenomena associated with defects in this versatile material system.
Results
ESR spectra and nuclear spin relaxation
Turning to the experimental results, scanning electron microscopy (SEM) images (Fig. 1a–d; Supplementary Fig. 1) and the ESR spectrum and simulation results (Fig. 1e) for a representative ND sample are shown. The ESR spectrum, which indicates the predominant types of defects available for use in hyperpolarization, can be seen to comprise three components that sum to produce the black simulation curve in Fig. 1e. These are a broad spin-1/2 Lorentzian component (blue trace) attributed to carbon dangling bonds near the surface of the ND, a narrow spin-1/2 Lorentzian component (yellow trace) attributed to defects within the diamond lattice, and a component associated with P1-colour centres (green trace), which constitutes a substitutional nitrogen atom with the extra electron hyperfine coupled with the 14N spin-1 nucleus. The number of P1-centre impurities, which lead to central (mI=0) and hyperfine transitions (mI=±1), increases as ND size increases, while the number of spin-1/2 impurities (broad and narrow spectra) decreases as ND size increases (Supplementary Figs 2 and 3).
These defect sites also provide the primary mechanism for 13C nuclear spin relaxation in ND. We find that the T1 relaxation time grows with increasing particle size, as shown in Fig. 1f. In determining these T1 times, the spin polarization build-up for smaller diamonds is well described by models36,37 in which the dipolar interaction of nuclear spins with paramagnetic impurities dominates over nuclear spin diffusion, leading to polarization curves that follow a stretched exponential form (see the Methods section). Diamond particles with average diameter approaching 1 μm, however, are better characterized by a double exponential in their polarization build-up with time. For 2 μm diamonds the longer component of the double exponential yields a T1 time of 63 min (see the Methods section and Supplementary Figs 4 and 5).
Brute force hyperpolarization
The simplest method of increasing the magnetic resonance signal from ND is to first cool the system to low temperatures in a high magnetic field to increase the Boltzmann population difference in the nuclear spins, a process termed brute force polarization. If the NDs are subsequently moved to a different magnetic field and temperature, the spin system can be considered hyperpolarized until it thermalizes on timescale T1. Using the brute force method, we hyperpolarize 2-μm ND at T=35 mK and B=4 T in a dilution refrigerator fitted with a rapid sample exchange system that allows fast (<1 min) transfer of the ND sample to a room temperature B=7 T spectrometer for detection. A π/2-pulse applied immediately after transfer produces a signal (Fig. 1g, inset) that is enhanced by an order of magnitude when compared with the signal from 2-μm ND at thermal equilibrium and B=7 T. To measure the relaxation time, a series of small tip angles is used to destroy the polarization over 0.5 h, as indicated by the decaying signal in Fig. 1g. The decay is a combination of T1 relaxation of spins in the ND (∼53 min) and polarization lost from the tipping pulses (see the Methods section for details).
Hyperpolarization via the solid effect
To achieve even higher polarizations and larger signals, DNP38 can be used to transfer electron polarization to the 13C nuclear spins in the diamond27. As described above, the source of these unpaired electrons in ND are paramagnetic centres in the lattice, dipolar coupled with a surrounding nuclear spin bath. Application of a microwave magnetic field slightly below the ESR frequency can drive spin flip–flops between nuclear and electron spins associated with centres, leading to a net transfer of spin polarization from the electrons to the nuclei near the impurities in a process known as the solid effect (Fig. 2a,b).
Turning to the main results of our work, we demonstrate that DNP can be used to hyperpolarize commercially available NDs, which as we have shown above, also exhibit long relaxation times. In the case of the largest diameter diamonds (2 μm) a T=4 K signal enhancement of ∼400 is achieved over thermal equilibrium, corresponding to a nuclear polarization of ∼8%, as shown in Fig. 2c–e. Comparing this hyperpolarized signal with the thermal signal at room temperature gives an enhancement of 13,500 similar to what has been demonstrated with isotopically labelled 13C liquid compounds23. We estimate that for a ND concentration of 1 mg ml−1, this amount of hyperpolarization leads to a spatial resolution better than 2 × 2 mm in a preclinical MRI scanner (Supplementary Note 1). Note that ND exceeding this concentration has already been used for therapeutic delivery in vivo12.
It is possible that by hyperpolarizing the nuclear spin system using DNP, new relaxation channels are created that shorten the relaxation time. We test this possibility by first polarizing 2-μm ND for 1 h and then allowing it to decay for 1 h at field. The resulting signal, shown in Fig. 2f, indicates a T1 comparable to measurements performed at thermal equilibrium. As a further demonstration of the potential for hyperpolarized ND, we show in Fig. 2g that the enhanced polarization can be maintained during transfer of the sample from a lower field polarizer to a high-field magnetic resonance detection system (see the Methods section for details).
Unlike hyperpolarized molecular compounds, the use of nanoparticles opens a new modality that links magnetic resonance signal strength (and relaxation time) to particle size. For hyperpolarized ND, we determine a significant size dependence to the signal enhancement, as shown in Fig. 2h. This dependence is most prominent for particle sizes below ∼300 nm, where the larger rate of spin relaxation competes with the rate at which hyperpolarization from DNP occurs. We suggest that this dependence on the diameter of NDs opens a means of selectively tracking particles based on their size distribution, potentially of use in determining the integrity of permeable barriers and epithelium membranes.
For potential clinical use of hyperpolarized MRI, a major drawback of the technique is the need for liquid helium to cool sample agents during the polarization phase. This drawback is particularly significant for applications that require magnetic resonance in remote locations, for instance in battlefield MRI using ultralow magnetic fields. In the case of hyperpolarized ND however, we find that sizeable enhancements are possible at liquid nitrogen temperatures (77 K; Fig. 2h), where cryogens are readily available. Extending this idea, Fig. 2h also shows that hyperpolarization is possible at room temperature, doing away with cryogens altogether.
Hyperpolarization in the presence of water
Room temperature hyperpolarization, even for modest enhancements, opens the prospect of new modalities that polarize and detect compounds in vivo. The significant barrier to this technique is the heating of water and surrounding tissue during the application of microwaves needed to perform DNP. Polarizing at low magnetic field and microwave frequency, however, can significantly reduce heating but requires sufficiently long T1 times to enable magnetic field ramping between polarization and high-field detection conditions39. Hyperpolarized ND appears well suited to explore this modality, since, for example, the signal from 350-nm ND (as a dry powder) can be enhanced by a factor of 40 at room temperature and exhibits a T1 of several minutes (long enough for field ramping). Since the polarize and detection sequence can be cycled many times in vivo (Fig. 3a), background noise can be averaged well below the limits imposed by one-shot polarize and detect methods.
To test this modality, we hyperpolarize a slurry of 125-nm ND and water (200 μl water with ∼50-mg ND) at room temperature. Even in the presence of ∼80 GHz microwaves, we observe a fourfold enhancement of 13C magnetic resonance signal from the diamond with little discernible heating of the water (Fig. 3b). This enhancement, which corresponds to a halving of the signal relative to the case without water, suggests that such modalities may be possible for small animals.
ND impurity selection and surface modification
The results presented so far are for ND samples readily obtained commercially, without further treatment or surface modification. We now turn to examine the role that surface impurities play in both hyperpolarization and relaxation, noting that there is significant scope to tailor the surface chemistry via passivation and treatment40. Our approach is to effectively perform ESR spectroscopy at the magnetic field used for DNP (B∼3 T), by monitoring the NMR signal enhancement as a function of microwave frequency (Fig. 4a; Supplementary Fig. 6). At room temperature, we observe enhancement spectra consisting of four peaks that are in agreement with the low-field ESR data shown in Fig. 1e. The position of these peaks correspond to DNP processes at ωe±ωn. As the temperature is lowered, these distinct peaks become dipolar broadened. The high-field DNP spectra are similarly broadened as the particle size is increased, as shown in Fig. 4b.
Modifying the defects or the types of defects within the NDs can change the DNP spectra, leading to enhanced polarization and longer relaxation times. We find that burning off the outer layer of ND using air oxidation processes41 removes some of the broad spin-1/2 component associated with impurities near the surface of the ND. This can be seen in Fig. 4c where we compare the hyperpolarization spectra of 25 nm air oxidation ND (black) with standard 25-nm ND (grey). The oxidation process leads to a suppression of the two central lines (f2 and f3) in the spectrum, consistent with removing some of the surface impurities that would otherwise contribute to the signal.
By adjusting the microwave frequency for DNP, we can select different impurity sites for use in hyperpolarization. Polarization via the P1-centres, for instance, can be selected by irradiating at the frequencies corresponding to the outer peaks (f1 and f4) in Fig. 4a. This is in contrast to irradiating at the inner peaks (f2 and f3), which also comprise both narrow and broad components from spin-1/2 sites (see discussion of Fig. 1e). Surprisingly, we find that hyperpolarization due to microwave driving at the inner peaks takes longer to build-up, and is retained longer than when driving at the outer peaks associated with the P1-centres. This behaviour is seen in Fig. 4d (Supplementary Figs 7 and 8; Supplementary Tables 1 and 2), where for 350-nm ND, we compare the decay of hyperpolarization established by driving at peak f1 or peak f2 in Fig. 4a. These results suggest that nuclear spin diffusion is somewhat suppressed in these systems, since relaxation appears dominated by the particular impurities selected for polarization via the choice of microwave frequency.
Beyond examining the spin dynamics of ND, these results are of practical interest in optimizing conditions for maximum signal enhancement with minimal relaxation. As an example, we compare the signal from 350 nm ND, initially irradiated with microwaves at the four distinct frequencies indicated in Fig. 4a and then subsequently transferred to a B=7 T system for detection. Following sample transfer, the relaxation data in Fig. 4e show that a larger polarization is maintained if the nuclei were polarized using the two central spectra peaks (f2 and f3), in comparison with the outer peaks associated with the P1-centres (f1 and f4).
Discussion
There is significant scope to further enhance the degree of hyperpolarization in ND. In particular, by adding microwave capability to our brute force hyperpolarizer at mK temperature (based on a dilution refrigerator), much larger polarizations appear possible. Eliminating isolated defects via surface passivation techniques 40 will also likely result in longer relaxation times. Another direction is to work with isotopically enriched 13C NDs to increase the number of spins that contribute to the signal and enhance spin diffusion from polarization sites on the surface to the spins in the core. Finally, we mention the possibility of using NDs for long-time storage of nuclear polarization that is transferred to the hydrogen nuclei in an aqueous environment using cross-polarization sequences42,43. Although the efficiency for polarization transfer is yet to be experimentally explored, this modality may enable life-science applications in which ND is tracked and imaged using standard MRI technology43.
Methods
Nanodiamonds
The NDs used in these experiments were purchased from Microdiamant. The diamonds are synthesized using the high-pressure high-temperature technique. The sizes of the NDs are given as a distribution and a median size. We refer to the diamonds by their median size. Measurements were recorded on MSY 0–0.030, (0–30 nm, median 18), MSY 0–0.05 (0–50 nm, median 25 nm), MSY 0-0.1 (0–100 nm, median 50 nm), MSY 0–0.15 (0–150 nm, median 75 nm), MSY 0–0.25 (0–250 nm, median 125 nm), MSY 0–500 (0–500 nm, median 210 nm), MSY 0.25–0.5 (250–500 nm, median 350 nm), MSY 0.25–0.75 (250–750 nm, median 500 nm), MSY 0.75–1.25 (750–1250, nm, median 1000, nm) and MSY 1.5–2.5 (1500–2500, nm, median 2000, nm).
SEM images
SEM measurements were recorded using a Zeiss Ultra Plus Gemini SEM spectrometer working in transmission mode. Suspensions were made of these NDs in water and a small amount of the suspension was placed on a TEM grid. The ND size distributions were confirmed (Supplementary Fig. 1).
ESR measurements
ESR measurements were recorded using a Bruker EMX-plus X-Band ESR Spectrometer. The cavity Q ranged between 5,000 for small ND particles and 10,000 for large ND particles. ESR spectra were taken at 0.25 μW, (within the linear regime of the saturation curves of the impurities) at a modulation amplitude of 1 Gs and a modulation frequency of 100 kHz. Each of the three components were simulated separately using Easyspin44 and added together to make the final spectrum. Linewidth, signal amplitude and g-factor were varied. The best fit to the data was performed using a least squares analysis.
T 1 relaxation
NMR measurements to determine the T1 relaxation times at B=7 T were made using a saturation recovery pulse sequence that involved 64 × π/2 saturation pulses to null any initial polarization followed by a varied time for polarization to build-up, and then a π/2 detection pulse. Time domain signals were acquired using a Redstone Tecmag system. Either a stretched exponential (smaller particles) M=M0(1−exp(−(t/T1)α) or a double exponential (larger particles) was fitted to the curve (Supplementary Fig. 4). Each ND size was measured three times and the average of the T1 times is plotted.
Brute force T 1 measurements
The decay of brute force hyperpolarization in Fig. 1g (red dots) was measured using a small tip angle detection sequence (θ=17°, TR=15 s). The solid red line is a fit to resulting in a T1 of 53 min. The decay is a combination of the T1 decay of the particles and the signal lost due to rf-induced polarization loss with tip angle θ where n is the nth pulse and TR is the repetition time. Every fifth peak is shown in black.
Hyperpolarization measurements
Measurements were recorded at a field of 2.88 T using a Redstone Tecmag system and a in-house constructed NMR probe (design details can be found in ref 45) inside an Oxford Instruments flow cryostat. The microwave source was a tuneable Gunn Oscillator (80.5–81.5 GHz) combined with a power amplifier. Microwaves were coupled with the sample using a waveguide. Polarization transfer measurements were determined using an in-house constructed NMR spectrometer based on a National Instruments system and an NMR probe at a field of 7 T. Before polarization the signal was saturated with 64 × π/2 pulses to null any signal. Enhancement measurements were recorded by hyperpolarizing the ND at f=80.855 GHz (4 K, 77 K) and 80.85 GHz (300 K) and then detecting the signal with a π/2-pulse. The hyperpolarized signal was compared with the NMR signal with no microwaves and the same polarization build-up time. Frequency sweeps: the frequency was swept between 80.78 and 81.12 GHz in discrete steps of 5 MHz and polarization was measured at every point. The 2-μm ND was polarized for 30 s, 3 min and 3 min at T=4 K, 77 K and 300 K, respectively. The spectra have been normalized to 1 for easier comparison.
Depolarization
Measurements at B=7 T: the ND was polarized for 15 min at four frequencies (f=80.87, 80.925, 80.99 and 81.05 GHz in successive experiments) and then transferred to a B=7 T magnet for detection. The transfer was performed in a field of B ∼0.7 T, created from rare-earth permanent magnets and took ∼20 s. A small tip angle pulse sequence with 8° pulses was used to detect the signal. Enhancement is compared with ND at thermal equilibrium at B=7 T. Measurements at B=2.88 T: the ND was polarized for 180 min at two frequencies and the decay was monitored with small tip angle pulses (every 15 s). Depolarization data were multiplied by cos(α)(n−1) to take into account rf-induced depolarization. The resulting data were fitted with a double exponential.
Additional information
How to cite this article: Rej, E. et al. Hyperpolarized nanodiamond with long spin-relaxation times. Nat. Commun. 6:8459 doi: 10.1038/ncomms9459 (2015).
Supplementary Material
Acknowledgments
We thank M. Cassidy for technical contributions in the construction of the hyperpolarization probe and M. Cassidy and C. Marcus for useful discussions. For SEM measurements, the authors acknowledge the facilities and technical assistance of the Australian Centre for Microscopy & Microanalysis at the University of Sydney. For ESR measurements, the authors acknowledge the staff and facilities at the Nuclear Magnetic Resonance Facility at the Mark Wainwright Analytical Centre at the University of New South Wales. This work is supported by the Australian Research Council Centre of Excellence Scheme (Grant No. EQuS CE110001013) ARC DP1094439, and the Lockheed Martin Corporation.
Footnotes
Author contributions E.R., T.G. and T.B. performed the experiment. All authors interpreted, processed and analysed the data. All authors contributed to writing the manuscript.
References
- Wang M. & Thanou M. Targeting nanoparticles to cancer. Pharmacol. Res. 62, 90–99 (2010). [DOI] [PubMed] [Google Scholar]
- Li C. A targeted approach to cancer imaging and therapy. Nat. Mater. 13, 110–115 (2014). [DOI] [PMC free article] [PubMed] [Google Scholar]
- Getts D. R. et al. Therapeutic inflammatory monocyte modulation using immune-modifying microparticles. Sci. Transl. Med. 6, 219ra7 (2014). [DOI] [PMC free article] [PubMed] [Google Scholar]
- Gupta A. S. Nanomedicine approaches in vascular disease: a review. Nanomedicine 7, 763–779 (2011). [DOI] [PubMed] [Google Scholar]
- Mura S. & Couvreur P. Nanotheranostics for personalized medicine. Adv. Drug Deliv. Rev. 64, 1394–1416 (2012). [DOI] [PubMed] [Google Scholar]
- Cassidy M. C., Chan H. R., Ross B. D., Bhattacharya P. K. & Marcus C. M. In vivo magnetic resonance imaging of hyperpolarized silicon particles. Nat. Nanotechnol. 8, 363–368 (2013). [DOI] [PubMed] [Google Scholar]
- Cassidy M. C., Ramanathan C., Cory D. G., Ager J. W. & Marcus C. M. Radical-free dynamic nuclear polarization using electronic defects in silicon. Phys. Rev. B 87, 161306 (2013). [Google Scholar]
- Liu K.-K., Cheng C.-L., Chang C.-C. & Chao J.-I. Biocompatible and detectable carboxylated nanodiamond on human cell. Nanotechnology 18, 325102 (2007). [Google Scholar]
- Huang H., Pierstorff E., Osawa E. & Ho D. Active nanodiamond hydrogels for chemotherapeutic delivery. Nano Lett. 7, 3305–3314 (2007). [DOI] [PubMed] [Google Scholar]
- Kruger A., Liang Y., Jarre G. & Stegk J. Surface functionalisation of detonation diamond suitable for biological applications. J. Mater. Chem. 16, 2322–2328 (2006). [Google Scholar]
- Say J. M. et al. Luminescent nanodiamonds for biomedical applications. Biophys. Rev. 3, 171–184 (2011). [DOI] [PMC free article] [PubMed] [Google Scholar]
- Chow E. K. et al. Nanodiamond therapeutic delivery agents mediate enhanced chemoresistant tumor treatment. Sci. Transl. Med. 3, 73ra21 (2011). [DOI] [PubMed] [Google Scholar]
- Chen M. et al. Nanodiamond-mediated delivery of water-insoluble therapeutics. ACS Nano 3, 2016–2022 (2009). [DOI] [PubMed] [Google Scholar]
- Zhang X.-Q. et al. Polymer-functionalized nanodiamond platforms as vehicles for gene delivery. ACS Nano 3, 2609–2616 (2009). [DOI] [PubMed] [Google Scholar]
- McGuinness L. P. et al. Quantum measurement and orientation tracking of fluorescent nanodiamonds inside living cells. Nat. Nanotechnol. 6, 358–363 (2011). [DOI] [PubMed] [Google Scholar]
- Maze J. R. et al. Nanoscale magnetic sensing with an individual electronic spin in diamond. Nature 455, 644–647 (2008). [DOI] [PubMed] [Google Scholar]
- Balasubramanian G. et al. Nanoscale imaging magnetometry with diamond spins under ambient conditions. Nature 455, 648–651 (2008). [DOI] [PubMed] [Google Scholar]
- Bhallamudi V. P. & Hammel P. C. Nitrogen–vacancy centres: Nanoscale MRI. Nature Nanotechnol. 10, 104–106 (2015). [DOI] [PubMed] [Google Scholar]
- Rugar D. et al. Proton magnetic resonance imaging using a nitrogen–vacancy spin sensor. Nature Nanotechnol. 10, 120–124 (2015). [DOI] [PubMed] [Google Scholar]
- Häberle T., Schmid-Lorch D., Reinhard F. & Wrachtrup J. Nanoscale nuclear magnetic imaging with chemical contrast. Nature Nanotechnol. 10, 125–128 (2015). [DOI] [PubMed] [Google Scholar]
- DeVience S. J. et al. Nanoscale NMR spectroscopy and imaging of multiple nuclear species. Nature Nanotechnol. 10, 129–134 (2015). [DOI] [PubMed] [Google Scholar]
- Brenneis A. et al. Ultrafast electronic readout of diamond nitrogen–vacancy centres coupled to graphene. Nature Nanotechnol. 10, 135–139 (2015). [DOI] [PubMed] [Google Scholar]
- Keshari K. R. & Wilson D. M. Chemistry and biochemistry of 13C hyperpolarized magnetic resonance using dynamic nuclear polarization. Chem. Soc. Rev. 43, 1627–1659 (2014). [DOI] [PMC free article] [PubMed] [Google Scholar]
- Ardenkjaer-Larsen J. H. et al. Increase in signal-to-noise ratio of > 10,000 times in liquid-state NMR. Proc. Natl Acad. Sci. USA 100, 10158–10163 (2003). [DOI] [PMC free article] [PubMed] [Google Scholar]
- Day S. E. et al. Detecting tumor response to treatment using hyperpolarized 13C magnetic resonance imaging and spectroscopy. Nat. Med 13, 1382–1387 (2007). [DOI] [PubMed] [Google Scholar]
- Nelson S. J. et al. Metabolic imaging of patients with prostate cancer using hyperpolarized [1-13C]pyruvate. Sci. Transl. Med. 5, 198ra108 (2013). [DOI] [PMC free article] [PubMed] [Google Scholar]
- Hoch M. J. R. & Reynhardt E. C. Nuclear spin-lattice relaxation of dilute spins in semiconducting diamond. Phys. Rev. B 37, 9222–9226 (1998). [DOI] [PubMed] [Google Scholar]
- King J. P., Coles P. J. & Reimer J. A. Optical polarization of 13C nuclei in diamond through nitrogen vacancy centers. Phys. Rev. B 81, 073201 (2010). [Google Scholar]
- Fischer R., Jarmola A., Kehayias P. & Budker D. Optical polarization of nuclear ensembles in diamond. Phys. Rev. B 87, 125207 (2013). [Google Scholar]
- Alvarez G. A. et al. Local and bulk 13C hyperpolarization in NV-centered diamonds at variable fields and orientations. Preprint at http://arxiv.org/abs/1412.8635 (2014). [DOI] [PMC free article] [PubMed]
- King J. P. et al. Room-temperature in situ nuclear spin hyperpolarization from optically-pumped nitrogen vacancy centers in diamond. Preprint at http://arxiv.org/abs/1501.02897 (2015). [DOI] [PMC free article] [PubMed]
- Panich A. M. et al. Nuclear magnetic resonance study of ultrananocrystalline diamonds. Eur. Phys. J. B 52, 397–402 (2006). [Google Scholar]
- Shames A. I. et al. Defects and impurities in nanodiamonds: EPR, NMR and TEM study. J. Phys. Chem. Solids 63, 1993–2001 (2002). [Google Scholar]
- Casabianca L. B., Shames A. I., Panich A. M., Shenderova O. & Frydman L. Factors affecting DNP NMR in polycrystalline diamond samples. J. Phys. Chem. C 115, 19041–19048 (2011). [Google Scholar]
- Dutta P., Martinez G. V. & Gillies R. J. Nanodiamond as a new hyperpolarizing agent and its 13C MRS. J. Phys. Chem. Lett. 5, 597–600 (2014). [DOI] [PubMed] [Google Scholar]
- Furman G. B., Kunoff E. M., Goren S. D., Pasquier V. & Tinet D. Nuclear spin-lattice relaxation via paramagnetic impurities in solids with arbitrary space dimension. Phys. Rev. B 52, 10182–10187 (1995). [DOI] [PubMed] [Google Scholar]
- Blumberg W. E. Nuclear spin-lattice relaxation caused by paramagnetic impurities. Phys. Rev. 119, 79–84 (1960). [Google Scholar]
- Abragam A. & Goldman M. Principles of dynamic nuclear polarisation. Rep. Prog. Phys. 41, 395–467 (1978). [Google Scholar]
- Lurie D. J., Davies G. R., Foster M. A. & Hutchison J. M. Field-cycled PEDRI imaging of free radicals with detection at 450 mT. Magn. Reson. Imaging 23, 175–181 (2005). [DOI] [PubMed] [Google Scholar]
- Baumann P. K. & Nemanich R. J. Surface cleaning, electronic states and electron affinity of diamond (100), (111) and (110) surfaces. Surf. Sci. 409, 320–335 (1998). [Google Scholar]
- Gaebel T. et al. Size-reduction of nanodiamonds via air oxidation. Diam. Relat. Mater. 21, 28–32 (2012). [Google Scholar]
- Bornet A., Melzi R., Jannin S. & Bodenhausen G. Cross polarization for dissolution dynamic nuclear polarization experiments at readily accessible temperatures 1.2 < T < 4.2 K. Appl. Magn. Reson. 43, 107–117 (2012). [Google Scholar]
- Marco-Rius I. et al. Quantitation of a spin polarization-induced nuclear Overhauser effect (SPINOE) between a hyperpolarized 13C-labeled cell metabolite and water protons. Contrast Media Mol. Imaging 9, 182–186 (2014). [DOI] [PMC free article] [PubMed] [Google Scholar]
- Stoll S. & Schweiger A. Easyspin, a comprehensive software package for spectral simulation and analysis in EPR. J. Magn. Reson. 178, 42–55 (2006). [DOI] [PubMed] [Google Scholar]
- Cassidy M. C. Hyperpolarized silicon particles as in-vivo imaging agents. Ph.D. thesis Harvard Univ. (2012).
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.