BACKGROUND: Simultaneous PET MRI offers opportunity to combine attributes of 18F-FET PET and MRI together during a single examination in the evaluation of post treatment glioma recurrence. The purpose of this study was to examine its potential in distinguishing glioma recurrence vs. radiation necrosis. METHODS: 27 patients with 36 suspicious brain lesions were evaluated with contrast enhanced 18F FET PET MRI using Biograph mMR acquired over 25 min immediately following tracer administration. Dynamic (20/27 patients: 5 data points), and static PET data ( 0 to 25 min) & MR images were analyzed using manually drawn ROI over the area of maximal contrast enhancement and/or FET uptake and migrating the same over corresponding other images to obtain various PET and MR parametric values for analysis. Statistical analysis was done for each parameter individually and in various combinations using Sigma Plot 13.0 and PASW 18. Positive histopathology and long term imaging/clinical follow up served as gold standard. RESULTS: 21 patients were classified as recurrence and 6 patients as radiation necrosis Individually, TBRmax, TBRmean, ADCmean, Cho: Cr ratios and normalized rCBVmean were significant in differentiating recurrence from radiation necrosis with an accuracy of 94.4% for TBRmax, 91% for TBRmean, 83.3% for ADCmean, 94.4% for Cho: Cr ratio and 86.1% for N rCBVmean respectively. TBRmax with Cho: Cr ratio yielded the highest accuracy of 97.2 % (AUC, 0.979± 0.03; sensitivity, 93.1%; specificity, 100%; P< 0.001). TTP & SUVmax of the lesion were found to be most significant parameters in distinguishing between recurrence & radiation necrosis with a p value of <0.05. SUVmax (p < 0.05) & slope to peak (p < 0.05) were most useful in differentiating low grade recurrence from radiation necrosis. CONCLUSION: Simultaneous FET PET MRI offers a quick and comprehensive method in differentiating glioma recurrence and treatment effect with high accuracy.
. 2015 Nov 9;17(Suppl 5):v161–v162. doi: 10.1093/neuonc/nov225.36
NIMG-36: COMPREHENSIVE EVALUATION OF GLIOMA RECURRENCE WITH SIMULTANEOUS O-(2-18F-FLUOROETHYL)-L-TYROSINE (18F-FET) POSITRON EMISSION TOMOGRAPHY MAGNETIC RESONANCE IMAGING (PET MRI)
Amarnath Jena
1, Sangeeta Taneja
1, Aashish Gambhir
2, Anil Kumar Mishra
2, Sapna Manocha Verma
1, Puja Panwar Hazari
2, Pradeep Negi
1, Ganesh Krishna Rao Jadhav
1, Shanti Kumar Sogani
1
Aashish Gambhir
2Molecular Imaging and Research Centre, Institute of Nuclear Medicine and Allied Sciences, New Delhi, India
Find articles by Aashish Gambhir
Anil Kumar Mishra
2Molecular Imaging and Research Centre, Institute of Nuclear Medicine and Allied Sciences, New Delhi, India
Find articles by Anil Kumar Mishra
Sapna Manocha Verma
1Indraprastha Apollo Hospital, New Delhi, India
Find articles by Sapna Manocha Verma
Puja Panwar Hazari
2Molecular Imaging and Research Centre, Institute of Nuclear Medicine and Allied Sciences, New Delhi, India
Find articles by Puja Panwar Hazari
Ganesh Krishna Rao Jadhav
1Indraprastha Apollo Hospital, New Delhi, India
Find articles by Ganesh Krishna Rao Jadhav
Shanti Kumar Sogani
1Indraprastha Apollo Hospital, New Delhi, India
Find articles by Shanti Kumar Sogani
1Indraprastha Apollo Hospital, New Delhi, India
2Molecular Imaging and Research Centre, Institute of Nuclear Medicine and Allied Sciences, New Delhi, India
Issue date 2015 Nov.
Published by Oxford University Press on behalf of the Society for Neuro-Oncology 2015.
PMCID: PMC4639059
