Use of a combined oxygen and carbon dioxide transcutaneous electrode in the estimation of gas exchange during exercise.

M K Sridhar 1, R Carter 1, F Moran 1, S W Banham 1
PMCID: PMC464594  PMID: 8346496

Abstract

BACKGROUND--Accurate and reliable measurement of gas exchange during exercise has traditionally involved arterial cannulation. Non-invasive devices to estimate arterial oxygen (O2) and carbon dioxide (CO2) tensions are now available. A method has been devised and evaluated for measuring gas exchange during exercise with a combined transcutaneous O2 and CO2 electrode. METHODS--Symptom limited exercise tests were carried out in 24 patients reporting effort intolerance and breathlessness. Exercise testing was performed by bicycle ergometry with a specifically designed protocol involving gradual two minute workload increments. Arterial O2 and CO2 tensions were measured at rest and during exercise by direct blood sampling from an indwelling arterial cannula and a combined transcutaneous electrode heated to 45 degrees C. The transcutaneous system was calibrated against values obtained by direct arterial sampling before each test. RESULTS--In all tests the trend of gas exchange measured by the transcutaneous system was true to the trend measured from direct arterial sampling. In the 140 measurements the mean difference between the O2 tensions estimated by direct sampling and the transcutaneous method was 0.08 kPa (0.62 mm Hg, limits of agreement 4.42 and -3.38 mm Hg). The mean difference between the methods for CO2 was 0.02 kPa (0.22 mm Hg, limits of agreement 2.20 and -1.70 mm Hg). There was no morbidity associated with the use of the transcutaneous electrode heated to 45 degrees C. CONCLUSIONS--A combined transcutaneous O2 and CO2 electrode heated to 45 degrees C can be used to provide a reliable estimate of gas exchange during gradual incremental exercise in adults.

Full text

PDF
643

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Bedford R. F., Wollman H. Complications of percutaneous radial-artery cannulation: an objective prospective study in man. Anesthesiology. 1973 Mar;38(3):228–236. doi: 10.1097/00000542-197303000-00006. [DOI] [PubMed] [Google Scholar]
  2. Clark J. S., Votteri B., Ariagno R. L., Cheung P., Eichhorn J. H., Fallat R. J., Lee S. E., Newth C. J., Rotman H., Sue D. Y. Noninvasive assessment of blood gases. Am Rev Respir Dis. 1992 Jan;145(1):220–232. doi: 10.1164/ajrccm/145.1.220. [DOI] [PubMed] [Google Scholar]
  3. Hughes J. A., Gray B. J., Hutchison D. C. Changes in transcutaneous oxygen tension during exercise in pulmonary emphysema. Thorax. 1984 Jun;39(6):424–431. doi: 10.1136/thx.39.6.424. [DOI] [PMC free article] [PubMed] [Google Scholar]
  4. Mahutte C. K., Michiels T. M., Hassell K. T., Trueblood D. M. Evaluation of a single transcutaneous PO2-PCO2 sensor in adult patients. Crit Care Med. 1984 Dec;12(12):1063–1066. doi: 10.1097/00003246-198412000-00013. [DOI] [PubMed] [Google Scholar]
  5. McKelvie R. S., Jones N. L. Cardiopulmonary exercise testing. Clin Chest Med. 1989 Jun;10(2):277–291. [PubMed] [Google Scholar]
  6. SEVERINGHAUS J. W., BRADLEY A. F. Electrodes for blood pO2 and pCO2 determination. J Appl Physiol. 1958 Nov;13(3):515–520. doi: 10.1152/jappl.1958.13.3.515. [DOI] [PubMed] [Google Scholar]
  7. Scheid P., Piiper J. Blood/gas equilibrium of carbon dioxide in lungs. A critical review. Respir Physiol. 1980 Jan;39(1):1–31. doi: 10.1016/0034-5687(80)90011-0. [DOI] [PubMed] [Google Scholar]
  8. Terminal dehydration. Lancet. 1986 Feb 8;1(8476):306–306. [PubMed] [Google Scholar]
  9. Yamanaka M. K., Sue D. Y. Comparison of arterial-end-tidal PCO2 difference and dead space/tidal volume ratio in respiratory failure. Chest. 1987 Nov;92(5):832–835. doi: 10.1378/chest.92.5.832. [DOI] [PubMed] [Google Scholar]

Articles from Thorax are provided here courtesy of BMJ Publishing Group

RESOURCES