Skip to main content
UKPMC Funders Author Manuscripts logoLink to UKPMC Funders Author Manuscripts
. Author manuscript; available in PMC: 2015 Nov 18.
Published in final edited form as: J Biol Rhythms. 2012 Feb;27(1):48–58. doi: 10.1177/0748730411431550

Rapid assessment of sleep/wake behaviour in mice

Simon P Fisher #, Sofia IH Godinho *, Carina A Pothecary *, Mark W Hankins *, Russell G Foster *,*, Stuart N Peirson *,*
PMCID: PMC4650254  EMSID: EMS61776  PMID: 22306973

Abstract

Sleep is a fundamental biological rhythm involving the interaction of numerous brain structures and diverse neurotransmitter systems. The primary measures used to define sleep are the electroencephalogram (EEG) and electromyogram (EMG). However, EEG-based methods are often unsuitable for use in high-throughput screens as they are both time-intensive and involve invasive surgery. As such, the dissection of sleep mechanisms and the discovery of novel drugs that modulate sleep would benefit greatly from further development of rapid behavioural assays to assess sleep in animal models. Here we describe an automated non-invasive approach to evaluate sleep duration, latency and fragmentation using video tracking of mice in their home cage. This approach provides a high correlation with EEG/EMG measures under both baseline conditions and following administration of pharmacological agents. Moreover, the dose-dependent effects of sedatives, stimulants and light can be readily detected. This approach is both robust yet relatively inexpensive to implement, and can be easily incorporated into ongoing screening programmes to provide a powerful first-pass screen for assessing sleep and allied behaviours.

Keywords: sleep, behaviour, phenotyping, non-invasive, video tracking, mice

Introduction

Sleep is perhaps the most familiar biological rhythm, arising from multiple brain structures and neurotransmitter systems. This coordinated neural activity in turn drives alternating patterns of behaviour characterised by changes in rest/activity, body posture and responsiveness to stimuli (Tobler 1995). However, despite decades of research many of the mechanisms underlying this complex behaviour remain poorly understood (Tafti & Franken 2002; Winrow et al 2009). Although sleep and wakefulness exhibit differences in both behavioural and neural parameters, the primary measures used to define sleep in mammals have focused upon neural surrogates. Electroencephalogram (EEG) and electromyogram (EMG) describe sleep on the basis of Rapid Eye Movement (REM) and Non-Rapid Eye Movement (NREM) states. This ‘Gold Standard’ approach of classifying sleep involves the implantation of cranial electrodes from which recordings are made via either tethered- or telemetry-based systems, enabling assessment of sleep structure, and the analysis of EEG power spectra for different sleep/wake states (Lo et al 2004; Weiergraber et al 2005). Whilst sleep/wake behaviours have been shown to persist in the absence of the neocortex (Vanderwolf et al 1978), EEG analysis has undoubtedly led to important advances in our understanding of sleep (e.g. (Chemelli et al 1999; Cirelli et al 2004; Franken et al 2001; Maret et al 2005; Tobler et al 1996). However, the application of EEG recordings to high-throughput studies has been limited (Winrow et al 2009). In addition, the need for surgical implantation of electrodes makes the EEG/EMG approach time-consuming, invasive, often expensive to implement and generally unsuitable for programs involving screening large numbers of animals. As a preliminary screen the use of simple behavioural definitions of sleep including duration, latency and number of sleep episodes (fragmentation) would provide a valuable first-pass evaluation of sleep/wake behaviour, prior to in-depth EEG studies.

Several attempts to address the requirement for a first-pass screen for sleep/wake behaviour have been developed. Storch et al., utilized small magnets implanted subcutaneously in mice and activity was determined by the movement of the magnet relative to a sensor beneath the cage (Storch et al 2004). Although this approach produced a reliable low resolution measure of activity/rest patterns it still necessitated surgical intervention. A non-invasive approach was developed by Flores et al., (Flores et al 2007) based upon monitoring behavioural activity through piezoelectric sensors positioned on the cage floor (Megens et al 1987). Sleep states were classified using a novel pattern recognition algorithm to identify regular motions associated with respiration when the animal assumed a specific sleep posture, whereas wake was characterised by large amplitude spikes in the piezoelectric signal (Flores et al 2007). This system was able to distinguish sleep from wake with up to a 0.95 correlation when compared to EEG analysis. Although this approach has been refined for high-throughput screens (Donohue et al 2008), the requirement of specialised equipment and custom software may limit the application of this method. A major advance in the area of high-throughput sleep scoring was made by Pack and colleagues in 2007, who utilised video monitoring combined with an object recognition algorithm to evaluate periods of sustained immobility as a surrogate of EEG/EMG defined sleep (Pack et al 2007). As many sleep labs routinely employ video recordings to assist in sleep scoring, this approach builds upon infrastructure that is often already in place and can also be used to evaluate other related behaviours. Importantly, they identified that periods of continuous inactivity ≥40 seconds were highly correlated with sleep in mice. Monitoring over a 24h period they showed that there was a 92% agreement with tethered EEG/EMG recordings (Pack et al 2007).

Although the studies described above provide strong evidence that high-throughput behavioural assays can accurately identify EEG/EMG definitions of sleep, these methods have not become widely adopted for first-pass sleep/wake assessment. One explanation for this may be the need for proprietary software, making these methods inaccessible. Moreover, these techniques have not been validated for assessing sleep/wake behaviour under different experimental paradigms (e.g. pharmacological and environmental manipulation). In recent years there have been major advances in the development of image-analysis software for a broad range of commercial and scientific tasks, including the assessment of multiple behaviours in mice (Crawley 2008). As a result high-throughput assessment of complex behaviours from video data using commercially available behavioural software offers an ideal solution for preliminary assessment of sleep/wake behaviour.

Here we describe a simple but robust automated technique to evaluate sleep/wake behaviour in mice based upon video monitoring with subsequent analysis using commercially available software. This approach provides an extremely high agreement (correlation coefficient >0.94) with EEG/EMG recordings under both baseline conditions and following administration of pharmacological agents. The flexibility of this method is illustrated by showing the dose-dependent effects of sedatives, stimulants and light on sleep/wake behaviours. Research on biological rhythms typically focuses on locomotor activity as a readily measured circadian behaviour. However, the absence of locomotor activity is not equivalent to sleep, and the lack of accessible assays can result in circadian research failing to address this fundamental biological rhythm. The approach described here provides a powerful first-pass screen for assessing sleep/wake behaviours, providing a valuable additional component to circadian phenotyping screens.

METHODS

Animals

Adult male C57BL/6 mice (3-9 months old, Harlan, UK) were used throughout the video-tracking and sleep validation studies. Mice were entrained under a standard 12h:12h L:D cycle for a minimum of 14 days and were given at least 72 h to habituate to a home cage prior to the start of all studies. Under these conditions light onset was designated Zeitgeber time (ZT) 0 and dark onset as ZT12. Ambient temperature was maintained at 22 ± 2 °C and food and water were available ad libitum. All studies were carried out under Home Office license and in accordance with the Animal (Scientific Procedures) Act 1986, UK.

Video equipment and experimental setup

For all studies mice were individually housed in plastic cages (25 × 30 cm) and isolated from possible confounding external stimuli using a system of light-tight ventilated chambers (manufactured by Lanview, Portsmouth, UK and ventilated with 120mm axial fans, 4412 F/2GLL-515, ebm-papst, Chelmsford UK). Light was provided using a custom overhead fibre optic light source system (Schott AG, Mainz, Germany) with light levels ~400 lux when measured at the bottom of the cage (Figure 1A). A 12-channel randomised fibre-optic cable (Schott AG, Mainz, Germany) was used to provide an even distribution of light over the cage area and was necessary to prevent interference with telemetry receivers caused by fluorescent lighting. Light-dependent resistors connected to a ClockLab interface (Actimetrics, Wilmette, IL, US) were used to record the light/dark conditions within the light-tight chamber at all times. Miniature near infra-red (NIR) video cameras (Sentient Mini-night vision CCTV camera, Maplin, UK) were mounted above each cage to permit the recording of mice under either light or dark (NIR) conditions. Cameras were fitted with a wide angle lens (130 degrees, 2.8mm, Open Twenty Four Seven Ltd, UK) to enable the whole cage area to be viewed. Cages were positioned approximately 30 cm below the camera which was centred over the area containing the mouse. In some circumstances, glare from the NIR LEDs in the cameras occurred from the cage bars, and this was reduced by use of tracing paper as a diffuser. Cameras were connected to a 16-channel digital hard-drive recorder (Model: VXM4B-16, Videcon. PLC) and video data was recorded at 25 frames per second with a resolution of 704 × 576 pixels. In order to maintain video-tracking throughout the study mice were prevented from entering an area hidden to the camera using custom made perspex blocks (23 × 12 × 3.2cm, Aquarius Plastics, Surrey UK). Video tracking was performed using ANY-maze® (Version 4.5, Stoelting, US). Full details of analysis protocols and software settings are provided as Supplementary information.

Figure 1.

Figure 1

Validation of immobility-defined sleep versus EEG/EMG-defined sleep. A) Experimental setup for the non-invasive assessment of sleep using digital video analysis. Mice were housed in light-tight chambers with light provided by a halogen light source through fibre optic cables. Miniature NIR cameras were mounted above each individual cage and were connected to a digital hard drive recorder and monitor. Video data was extracted from the hard drive recorder and analysed offline using commercially available video-tracking software (ANY-maze, Stoelting). B) Comparison of sleep assessed by digital video analysis (“Immob”) compared with EEG/EMG defined sleep (“EEG”) across a 24 hour baseline period under a 12:12 LD cycle for an individual mouse. C) Average immobility-defined sleep determined using digital video analysis and EEG/EMG in 6 mice. D) Bland-Altman plot displaying the mean difference (minutes) between the two methods used to assess sleep using the individual 30 minute values from B. The estimated bias across the 24 hour period was +0.24 minutes with a standard deviation of 2.93 minutes. The Bland-Altman 95% limits of agreement were −5.50 to +5.98 minutes. Data points were analysed in 30 minute periods to more accurately represent the polyphasic nature of sleep in mice. A similar high correlation was observed when analysed in 1h periods. In all cases sleep per 30min interval is shown and sensitivity was set at 95%.

EEG/EMG Recording and Analysis

Mice anaesthetised under isoflurane (3-5% for induction, 1-3% for maintenance) were implanted with EEG/EMG telemetry transmitters (TL11M2-F-20, EET, Data Sciences International, St. Paul, USA) as described previously (Lupi et al 2008). Mice were allowed at least 3 weeks to recover before studies were undertaken. All implanted mice remained healthy and gave clear EEG/EMG recordings allowing the discrimination of sleep/wake stages. EEG and EMG data were transmitted to a radio receiver (RPC-1, Data Sciences International, St. Paul, USA) placed underneath each cage. Signals were then routed via a data exchange matrix to a PC running Dataquest A.R.T. software (version 3.01). The EEG and EMG data were continuously sampled using DSI Dataquest Gold acquisition software at 500 Hz, with a 100 Hz filter cut-off. EEG and EMG signals were band-pass filtered (0.5-35 Hz for EEG and 80-100 Hz for EMG) and sleep/wake stages were scored offline as wakefulness, non-rapid eye movement (NREM) sleep and rapid eye movement (REM) sleep in 10 sec epochs using a semi-automated approach. The sleep scoring procedure consisted of an initial automated step using SleepSign® software (Kissei Comtec, Nagano, Japan), followed by a review of all epochs by an experienced sleep scorer. Total sleep for the recording period was determined by the addition of all NREM and REM epochs.

Assessment of Baseline Sleep Determined by Simultaneous EEG/EMG and Video Analysis

Mice implanted with EEG/EMG electrodes were recorded simultaneously using video cameras in their home cage. Once mice were entrained and acclimatised to the cage environment EEG, EMG, and video data were recorded for a 24 hour period (under a 12:12 light/dark cycle). Offline analysis of the video data determined the optimum immobility detection settings. In addition to the duration of immobility required to accurately identify sleep (as described by Pack et al., 2007), the definition of immobility also depends upon the percentage of the area of the tracked animal that is required to be immobile. If this is set too low, false positives will occur when the animal is stationary but not asleep, for example, when grooming or feeding. If this is set too high, false negatives will occur due to small movements associated with respiration and muscle twitches during sleep. To address this issue of sensitivity, the immobility sensitivity setting within the software was adjusted in increments from 50-100% and comparing the total amounts of sleep derived from EEG/EMG classification. The baseline 24 hour period was analysed in both 1 hour and 30 minutes segments to determine the correlation of the method at higher and lower resolutions.

Effect of Zolpidem on Immobility-defined Sleep in Comparison with EEG/EMG Analysis

Three different doses of zolpidem (10, 5 or 1 mg/kg i.p, Tocris, Bristol, UK) dissolved in physiological saline (containing 0.3 % Tween80, Sigma-Aldrich) or vehicle were administered to three separate groups of mice (n=6 for each dose/vehicle) at ZT14 (2 hours after lights off). Each dose of zolpidem was administered together with an independent vehicle and all mice were dosed using a randomised design with each mouse receiving a single injection. All drug solutions were freshly prepared on the day of the experiment and injected intraperitoneally at a volume of 10ml/kg body weight with administration typically completed in 5 minutes for 6 mice. Upon dosing mice were immediately returned to their home cage. Video data was analysed for a 1 hour baseline period and up to 5 hours post administration. In a separate validation study mice (n=4) implanted with EEG/EMG electrodes were administered either zolpidem (10mg/kg, i.p) or vehicle at ZT14. Simultaneous EEG, EMG and video data were recorded for a period of 6 h including 1 h prior to drug administration. A time course of sleep duration for both EEG/EMG and video determined sleep were then calculated at 10 minute intervals to provide a high resolution measure of sleep induction. For all studies involving sleep latency, sleep onset was defined as the time from the point of injection to the period of 2 minutes of continuous immobility.

Effect of Caffeine on Immobility-defined Sleep

Mice were administered either caffeine (15mg/kg, dissolved in physiological saline n=6, Tocris, Bristol UK) or vehicle (0.9% w/v NaCl, n=6) intraperitoneally at ZT0 (lights onset). Upon dosing mice were returned to their home cage and video data was analysed for a 1 hour pre-drug baseline period for up to 5 hours post administration. The effect of caffeine on immobility-defined sleep onset and duration together with the number of immobile episodes was then determined.

Acute Effects of Light on Immobility-defined Sleep

To evaluate the robustness of our methods further we assessed the dose-dependent effects of light on sleep during the habitual wake period. Mice (n=6) were entrained to a 12:12 L:D cycle and administered three different 2 hour light pulses of increasing intensity (0.7, 70 and 700 lux) in a fully randomised order at ZT14. These were performed on different experimental days with a minimum of 6 days between light pulse exposures. Video data was analysed 1.5 hours prior to light administration for a total period of 4.5 hours.

Statistical Analysis

Analysis of agreement was performed using the Bland-Altman statistical method (Bland & Altman 1986). The 24 hour baseline sleep/wake period determined by digital video and EEG/EMG analysis were divided into 24 × 1 h segments. In addition to enable a higher resolution analysis of the data this baseline period was also analysed in 48 × 30 min segments to more accurately represent the polyphasic nature of sleep in rodents. We determined the mean bias by calculating the difference between estimates of sleep based on immobility and that defined by EEG/EMG analysis. Immobility-defined sleep onset latency data was analysed using a Student’s t-test with P values <0.05 considered statistically significant. Time course analysis and immobile episodes were assessed using a two-way ANOVA (Factors: Time and treatment). Light pulse data were analysed for the effect of light intensity on immobility-defined sleep during the first 45 minutes of light exposure using a one-way ANOVA. Where applicable, Bonferroni’s post hoc tests were used.

RESULTS

Baseline sleep: EEG/EMG vs. video analysis

A high level of agreement was achieved in the assessment of sleep using digital video analysis compared to simultaneous EEG/EMG defined sleep in individual mice (Figure 1B) and for the average values derived from 6 mice across a 24 h baseline period (Figure 1C). Initially the data was compared using hourly values for sleep across the 24h baseline (data not shown). The average EEG/EMG determined sleep per 1 hour interval across a 24 hour period was 32.71 ± 13.48 minutes. By comparison, sleep estimated by digital video analysis was 33.19 ± 15.41 minutes, resulting in a bias of +0.48 minutes (95% confidence interval +3.41, −4.37 minutes, correlation coefficient 0.94). Using this approach with a temporal resolution of 30 minutes demonstrated that digital video analysis still provided a remarkable fit (correlation coefficient 0.94) compared to EEG/EMG recordings under baseline conditions (Figure 1B & 1C). When comparing two methods of measurement, the difference between the approaches may depend on the magnitude, producing a bias at high or low values. As such, we used the method of Bland and Altman (1986) to compare these two methods (Figure 1D). Using this approach the estimated bias over 24h was 0.24 minutes. The Bland-Altman 95% limits of agreement were −5.50 to +5.98 minutes. The sensitivity of immobility scoring by ANY-maze® was also evaluated by comparing sleep estimated by this method to that determined using EEG/EMG analysis whilst varying the immobility sensitivity value from 50-100%. We identified that the optimal sensitivity value producing the smallest bias was 95% giving a correlation of 0.94 (Supplementary Figure 1).

Effects of zolpidem: EEG/EMG vs video analysis

Pharmacologically induced sleep using the hypnotic zolpidem was compared with simultaneous EEG/EMG and video analysis. For these studies the recording period and subsequent analysis was undertaken using higher resolution (10 minute intervals). There was excellent agreement with video vs. EEG/EMG defined sleep even at this resolution (Figure 2). Again, Bland-Altman statistical analysis demonstrated no systematic bias (+0.06 for zolpidem, +0.15 minutes for vehicle).

Figure 2.

Figure 2

Comparison of sleep assessed using digital video analysis with EEG/EMG defined sleep after administration of A) vehicle (0.9% w/v NaCl) or B) zolpidem (10mg/kg). Treatments were administered at ZT14. Data points were analysed in 10 minute periods and represent mean values ± SEM, n = 4. Using the Bland-Altman method to assess agreement for post-injection values after zolpidem treatment resulted in a bias of +0.06 minutes with a standard deviation of 1.25 minutes (2.52 to −2.40 minutes, correlation coefficient 0.94). For vehicle treatment the bias was +0.15 minutes with a standard deviation of 1.02 minutes (Bland-Altman Limits of agreement: 2.15 to −1.85 minutes, correlation coefficient 0.95). In all cases sleep per 10min interval is shown and sensitivity was set at 95%.

Dose effect of zolpidem on sleep

We determined the sensitivity of the video analysis approach in estimating sleep by evaluating the changes in sleep after three different doses of zolpidem. 10mg/kg and 5mg/kg produced significant increases in sleep duration (Figure 3A and B). Vehicle administration also produced a smaller increase in sleep, most likely due to the effects of handling/injection. Whilst 1mg/kg did not produce a significant increase in sleep duration when analysed in 1h bins, it is clear from an analysis of the entire time course that 1mg/kg zolpidem does increase immobility-defined sleep, although to a much smaller extent (to around 75%) and for a shorter period (~30 minutes post administration) compared to higher doses (Figure 3C). Using 30 minute intervals, 1mg/kg clearly shows a significant increase in sleep duration when compared to vehicle (Unpaired Student’s t-test, P<0.001). Moreover, the effect of 1mg/kg zolpidem is immediately evident from analysis of immobility-defined sleep onset latency, which was highly significant with all doses (Table 1). Interestingly, the higher doses (10 and 5 mg/kg) both led to a second period of increased immobility-defined sleep approximately 140 minutes post administration, which was not evident with 1mg/kg. All three doses of zolpidem increased the number of immobile episodes during the first hour post administration (Supplementary Figure 2). Both the 5 and 10 mg/kg doses also significantly increased immobile episodes 2-3 hours post injection.

Figure 3.

Figure 3

Evaluation of the effect of three doses of zolpidem (solid lines) or vehicle (dashed lines) on immobility-defined sleep determined using digital video analysis. Zolpidem was dosed i.p at A) 10 mg/kg, B) 5mg/kg and C) 1mg/kg at ZT14. Zolpidem dosed at 10 and 5 mg/kg resulted in a significant increase in the amount of immobility-defined sleep (to around 90%) compared to vehicle (F1,10=22.2,P<0.001 at 10mg/kg and F1,10=11.8, P<0.01 at 5mg/kg). In addition, there were significant changes in sleep duration over the time course studied with all doses tested (F5,50=6.1, P<0.001 at 10mg/kg; F5,50=11.7, P<0.001 at 5mg/kg; F5,50 =7.7, P<0.001 at 1mg/kg). At 10mg/kg and 5mg/kg there was also a significant interaction, with differences in sleep over the time course being dependent upon the vehicle or zolpidem treatment (F5,50=2.6, P<0.05 at 10mg/kg; F5,50=3.1, P<0.05 at 5mg/kg). A dose of 1 mg/kg zolpidem did not produce a significant effect on sleep duration from the vehicle. The solid black arrows indicate the time of drug/vehicle administration. Data points represent mean vales ± SEM for 6 mice. Bar graphs depict the total duration of immobility-defined sleep in hourly intervals where * denotes P< 0.05 and ** denotes P<0.01. Note: A separate vehicle condition was used for each of the doses of zolpidem. In all cases sleep per 10min interval is shown and sensitivity was set at 95%.

Table 1.

Dose-dependent effects of zolpidem on immobility-defined sleep onset latency. Immobility-defined sleep onset latency (defined as the latency to 2 minutes of continuous immobility post treatment) for zolpidem dosed at 10, 5 and 1 mg/kg and respective vehicle treatments. Data represents mean ± SEM, n = 6. Vehicle and zolpidem values were analysed using Students t-test.

Treatment Immobility-defined sleep onset latency (min)
Vehicle 37.0 ±4.81
Zolpidem 10mg/kg 5.0 ±1.03 ***
Vehicle 36.0 ±3.09
Zolpidem 5mg/kg 6.17 ±2.18 ***
Vehicle 32.0 ±2.44
Zolpidem 1mg/kg 5.67 ±0.95 ***
**

denotes P < 0.01

***

denotes P < 0.001

Effect of caffeine on sleep

The effects of caffeine (15 mg/kg) on immobility-defined sleep were also determined using digital video analysis. There was a significant change in sleep duration over the time course studied (F35,360 =6.0, P<0.001), as would be expected for the beginning of the light period (Figure 4A). In addition, mice administered caffeine exhibited a significant reduction in the amount of sleep during the first 120 minutes post administration (F1,360=56.8, P<0.001). The amount of sleep did not return to levels comparable to the vehicle-treated mice until ~180 minutes post caffeine administration (Figure 4A). There was a significant interaction of treatment and time, with caffeine and vehicle producing different temporal effects (F35,360 =3.4, P<0.001). Caffeine was also demonstrated to significantly decrease the number of immobile episodes (F1,10=5.0, P<0.05) for up to 3 hours post administration (Figure 4B) and significantly delayed immobility-defined sleep latency (111.17 +/− 24.35 minutes, unpaired Student’s t-test P<0.01) compared to mice administered vehicle (19.67 +/− 1.89 minutes) (Figure 4C).

Figure 4.

Figure 4

Effect of caffeine (15 mg/kg) administered at ZT0 on immobility-defined sleep assessed using digital video analysis. A) Time course of drug administration displaying vehicle (open circles) and caffeine (closed circles) dosed i.p at ZT0 (10 minute resolution). There was a significant change in sleep duration over the time course studied (F35,360 =6.0, P<0.001), due to the onset of the light phase. In addition, mice administered caffeine exhibited a significant reduction in the amount of sleep during the first 120 minutes post administration (F1,360=56.8, P<0.001). There was a significant effect of caffeine from 25 mins to 105 mins (post hoc Bonferroni test P<0.05). The amount of sleep did not return to levels comparable to the vehicle-treated mice until ~180 minutes post caffeine administration. B) The number of immobile/sleep episodes represented as hourly values. C) The latency to the first immobile period (2 minutes of continuous immobility). **, P < 0.01 vehicle vs. caffeine. Data points represents mean values ± SEM, n =6. In all cases sleep per 10min interval is shown and sensitivity was set at 95%.

Effect of light on sleep

Light pulses of increasing intensity produced a dose-dependent increase in immobility-defined sleep in mice during the habitual sleep period (Figure 5). A one-way ANOVA was used to test for the acute effects of light on total immobility-defined sleep across the first 45 minutes of light exposure. This identified a strong intensity dependent sleep-promoting response to light (F2,15 =26.56, P<0.001). Decreasing light intensity from 700 to 70 lux did not reduce the initial peak of immobility-defined sleep induction but did reduce the duration of the sleep-producing effect. The 0.7 lux light pulse resulted in a relatively small transient increase in immobility-defined sleep at approximately 20 minutes into the light exposure with a second small increase in sleep induction occurring at 60 minutes. For all three light intensities there was a gradual decrease in immobility-defined sleep at approximately 70 minutes until the end of the light pulse.

Figure 5.

Figure 5

Evaluation of the effect of three different intensity light pulses on immobility-defined sleep assessed using digital video analysis. A) Time course of a 2 hour light pulse administered at ZT14 including the baseline and post-light pulse periods for 0.7, 70 and 700 lux light. Data points are plotted in 10 minute intervals as mean values ± SEM, n=6. One-way ANOVA was used to test for the acute effects of light on total immobility-defined sleep across the first 45 minutes of light exposure. This identified a strong intensity dependent sleep-promoting response to light (F2,15 =26.56, P<0.001). B) Bar graph representing the total amount of immobility-defined sleep for the 3 different light intensities in the first 45 minutes of light exposure depicted by ‘X’ on A. Data were compared using a one-way ANOVA with a Bonferroni post hoc test. ***, p<0.001 700 lux vs. 0.7 lux and **, P<0.01 70 lux vs. 0.7 lux. In all cases sleep per 10min interval is shown and sensitivity was set at 95%.

DISCUSSION

Despite the dramatic changes in sleep and wakefulness over the 24h cycle, research on biological rhythms has often focused on locomotor activity rather than sleep/wake timing as a behavioural output of the circadian system. Here we describe a high-throughput system that can provide a rapid yet robust assessment of sleep/wake behaviour in mice. This approach was compared with simultaneous EEG/EMG determined sleep under baseline conditions and following administration of the sedative-hypnotic zolpidem. Defining sleep as a period of extended immobility (>40s) during which 95% or more of the area of the animal is stationary, we obtained a 0.94 correlation with simultaneous EEG/EMG defined sleep (Figure 1C) with no significant systematic bias. This method is not only able to determine total sleep duration per time interval but also the sleep onset latency and number of immobile episodes. Rather than a gross neural correlate of sleep, this approach relies upon the pronounced differences in behaviour that define sleep. A key advantage of this automated system is that immobility detection utilises commercially available software to automatically determine a minimum duration of inactivity, enabling the simultaneous off-line analysis of up to 16 animals (per computer). As well as using the =>40 seconds of immobility identified by Pack and colleagues (Pack et al 2007), we also determined the percentage area of the mouse required to remain immobile for the accurate determination of sleep. By varying the sensitivity of this component of immobility detection and comparing this to EEG/EMG defined sleep we identified that the optimum sensitivity setting was 95% (Supplementary Figure 1). Using a sensitivity setting greater than 95% resulted in an underestimation of sleep, whereas sensitivity settings below 95% resulted in an overestimation of sleep. Using a 95% sensitivity criteria over a 24 hour light/dark cycle (12:12 L:D) the estimated bias of the method compared to EEG/EMG analysis was just +0.48 minutes/hour (Supplementary Table 1).

As well as evaluating sleep under baseline conditions, we assessed the suitability of this technique in measuring the effects of pharmacological compounds on sleep. Following the administration of zolpidem, a non-benzodiazepine hypnotic, immobility-defined sleep gave a high correlation with EEG/EMG defined sleep (0.94). The bias was again small, just +0.06 minutes (SD, 1.25 minutes) when compared against sleep assessed by EEG/EMG (Figure 2). This agreement was striking particularly as the data were analysed at a higher resolution of 10 minute intervals. To evaluate dose-dependent effects, three doses of zolpidem (10, 5 and 1 mg/kg) were measured using video tracking, each in a different groups of animals. This produced highly consistent sleep/wake profiles, demonstrating the reproducibility of the system (Figure 3). The method was also able to differentiate between the effects of relatively high and low doses of zolpidem on sleep. The higher doses of zolpidem (5 & 10 mg/kg) differed considerably from the 1 mg/kg dose in terms of the initial amount of immobility-defined sleep during the first hour and the number of immobile episodes and sleep amount 2-3 hours post injection. Only very subtle differences were evident between the effects of 5 and 10 mg/kg zolpidem on immobility-defined sleep, suggesting these doses produced near-saturating responses. Previous studies assessing the effects of zolpidem on sleep have used EEG analysis, however such studies typically administer zolpidem in the light period when sleep pressure is high in nocturnal animals (Alexandre et al 2008; Kopp et al 2004), making direct comparisons difficult. Despite this, Alexandre et al. (2008) reported no difference between the effects 10, 5 and 2 mg/kg zolpidem on NREM sleep during the first two hour post injection with all doses resulting in a significant increase in sleep induction compared to vehicle.

The effects of the caffeine on sleep/wake behaviour in mice at the beginning of the habitual rest period (ZT0) were also studied (Figure 4). Mice were administered caffeine at a dose of 15mg/kg; approximately equivalent to a human consuming six cups of strong coffee prior to sleep. Video analysis was very effective in detecting a significant increase in wakefulness for up to 3 hours post caffeine administration. A previous study using EEG-defined sleep and administering an identical dose of caffeine reported a comparable duration of wakefulness (Huang et al 2005). Collectively the data emphasise the validity of using video monitoring to assess the impact of drugs on the regulation of sleep.

Changes in environmental light exposure are an additional factor known to modulate sleep/wake behaviour either indirectly through the entrainment of circadian rhythms or directly in the form of acute sleep/wake transitions. Previous studies in nocturnal rodents have demonstrated that light exposure increases sleep whilst darkness promotes wakefulness (Benca et al 1998; Borbely et al 1975). In the current study we demonstrated that this video tracking approach could differentiate between the effects of dim and bright light on sleep induction during the habitual dark period and detect the intensity-dependent effects of light on sleep throughout the duration of the light pulse (Figure 5). Moreover, this data also demonstrates that this method is sensitive enough to discriminate between the effects of different light intensities on sleep.

All surrogate measures of sleep have inherent limitations. The primary limitation of this approach is that it is unable to determine sleep architecture (REM vs. NREM sleep). As such, we would envisage that this method is used as a first-pass assessment of sleep/wake behaviour, particularly when screening large numbers of transgenic or mutant animals, or large numbers of pharmacological compounds. This would then enable targeted selection of optimum candidates for detailed EEG/EMG assessment. Moreover, it is conceivable that the use of immobility (=>40s, 95% sensitivity) may be suboptimal under certain conditions. In the present study we administered zolpidem which exhibits preferential affinity for the alpha-1 GABA(A) receptor subtype, which is associated with sedative rather than muscle relaxant properties (Crestani et al 2000). Clearly, agents that have a strong effect on muscle tone such as high doses of GABAergic compounds may result in a degree of muscle relaxation which might be incorrectly scored as immobility-defined sleep. In addition, these studies are based on C57BL/6 mice which display relatively clear bouts of activity and inactivity. Future studies would be required to determine sleep/wake behaviour in different strains of mice (Franken et al 1999).

The system we describe here provides a robust high-throughput screen for sleep/wake behaviour which can be incorporated easily into any existing phenotyping test battery. It provides an ideal first-pass screen to evaluate transgenic/mutant mice or the effects of novel compounds prior to more focussed studies using EEG/EMG. An additional advantage of using video tracking to assess sleep is that it enables the simultaneous evaluation of additional behavioural repertoires associated with changes in sleep and wakefulness. These include parameters such as the distance travelled or the time spent in certain areas of the cage, which can provide additional data on anxiety or behavioural inhibition. An example of the extended data available over 24h is shown in Supplementary Figure 3. This degree of flexibility may be particularly valuable as part of behavioural phenotyping programmes, in that it enables archived data to be subjected to post-hoc data mining to evaluate other behaviours of interest.

EEG/EMG studies require surgical experience and an understanding of EEG data analysis. The methods described here provide a more accessible approach for assessing basic sleep/wake behaviour. Low cost miniature infrared cameras and hard drive storage make the initial setup costs under £7000 - considerably lower than EEG/EMG telemetry (excluding costs of light-tight chambers). Once the hardware is in place the costs of screening are minimal – just that required for housing animals. Whilst such an approach cannot replace the requirement for EEG/EMG in sleep research, it provides a valuable additional tool for sleep assessment in transgenic or mutant mice, or in the preliminary stages of drug development. As part of a test battery, the use of video monitoring to assess sleep/wake timing in addition to wheel-running provides additional valuable data on this fundamental biological rhythm that is often overlooked in circadian research.

A substantial advantage of the use of video tracking is that it is an entirely non-invasive method. This provides a major welfare advantage against EEG. Moreover, in certain conditions the need for a tether or implanted telemetry device can potentially affect the behaviour of the animal, particularly in mice where the implant size is typically disproportionately large compared to body mass (Leon et al 2004). The advantage of a non-invasive approach is particularly evident when evaluating sleep in mouse models of disease, as animals may be too frail to undergo invasive procedures or data may be confounded due to transgenics showing different responses to surgery or post-operative recovery rather than a real difference in sleep/wake behaviour.

Conclusions

Here we describe a low cost and high-throughput assay to assess sleep/wake behaviour in mice, based on digital video tracking using commercially-available behavioural phenotyping software. This approach is non-invasive and markedly inexpensive, yet provides an extremely high correlation with simultaneous EEG/EMG assessment of sleep. Whilst it is currently not possible to evaluate REM/non-REM sleep using this approach, it provides an ideal preliminary screen for an assessment of sleep duration, sleep fragmentation and sleep latency in response to genetic modification, environmental manipulation or compound administration. The provision of additional high-throughput tools for circadian and sleep research should improve both our understanding of the genetic mechanisms involved in sleep/wake regulation as well as facilitating drug discovery in this area.

Supplementary Material

Supplementary Material

Acknowledgements

We thank Chris Lloyd (AnyMaze) for technical assistance with the video-tracking software and members of our research group for encouragement and advice throughout. We would also like to thank Dr Silvia Gatti-MacArthur (Hoffman-La Roche) for feedback. This work was supported by a Wellcome Trust Programme Grant to RGF/SNP and EUCLOCK (FP6 IP) to RGF. SPF was supported by a Knoop Junior Research Fellowship (St Cross, Oxford). SIHG is supported by Hoffman-La Roche.

Footnotes

Competing Interests: The authors declare no competing interests.

REFERENCES

  1. Alexandre C, Dordal A, Aixendri R, Guzman A, Hamon M, Adrien J. Sleep-stabilizing effects of E-6199, compared to zopiclone, zolpidem and THIP in mice. Sleep. 2008;31:259–70. doi: 10.1093/sleep/31.2.259. [DOI] [PMC free article] [PubMed] [Google Scholar]
  2. Benca RM, Gilliland MA, Obermeyer WH. Effects of lighting conditions on sleep and wakefulness in albino Lewis and pigmented Brown Norway rats. Sleep. 1998;21:451–60. doi: 10.1093/sleep/21.5.451. [DOI] [PubMed] [Google Scholar]
  3. Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986;1:307–10. [PubMed] [Google Scholar]
  4. Borbely AA, Huston JP, Waser PG. Control of sleep states in the rat by short light-dark cycles. Brain Res. 1975;95:89–101. doi: 10.1016/0006-8993(75)90209-7. [DOI] [PubMed] [Google Scholar]
  5. Chemelli RM, Willie JT, Sinton CM, Elmquist JK, Scammell T, et al. Narcolepsy in orexin knockout mice: molecular genetics of sleep regulation. Cell. 1999;98:437–51. doi: 10.1016/s0092-8674(00)81973-x. [DOI] [PubMed] [Google Scholar]
  6. Cirelli C, Gutierrez CM, Tononi G. Extensive and divergent effects of sleep and wakefulness on brain gene expression. Neuron. 2004;41:35–43. doi: 10.1016/s0896-6273(03)00814-6. [DOI] [PubMed] [Google Scholar]
  7. Crawley JN. Behavioral phenotyping strategies for mutant mice. Neuron. 2008;57:809–18. doi: 10.1016/j.neuron.2008.03.001. [DOI] [PubMed] [Google Scholar]
  8. Crestani F, Martin JR, Mohler H, Rudolph U. Mechanism of action of the hypnotic zolpidem in vivo. Br J Pharmacol. 2000;131:1251–4. doi: 10.1038/sj.bjp.0703717. [DOI] [PMC free article] [PubMed] [Google Scholar]
  9. Donohue KD, Medonza DC, Crane ER, O’Hara BF. Assessment of a non-invasive high-throughput classifier for behaviours associated with sleep and wake in mice. Biomed Eng Online. 2008;7:14. doi: 10.1186/1475-925X-7-14. [DOI] [PMC free article] [PubMed] [Google Scholar]
  10. Flores AE, Flores JE, Deshpande H, Picazo JA, Xie XS, et al. Pattern recognition of sleep in rodents using piezoelectric signals generated by gross body movements. IEEE Trans Biomed Eng. 2007;54:225–33. doi: 10.1109/TBME.2006.886938. [DOI] [PubMed] [Google Scholar]
  11. Franken P, Chollet D, Tafti M. The homeostatic regulation of sleep need is under genetic control. J Neurosci. 2001;21:2610–21. doi: 10.1523/JNEUROSCI.21-08-02610.2001. [DOI] [PMC free article] [PubMed] [Google Scholar]
  12. Franken P, Malafosse A, Tafti M. Genetic determinants of sleep regulation in inbred mice. Sleep. 1999;22:155–69. [PubMed] [Google Scholar]
  13. Huang ZL, Qu WM, Eguchi N, Chen JF, Schwarzschild MA, et al. Adenosine A2A, but not A1, receptors mediate the arousal effect of caffeine. Nat Neurosci. 2005;8:858–9. doi: 10.1038/nn1491. [DOI] [PubMed] [Google Scholar]
  14. Kopp C, Rudolph U, Tobler I. Sleep EEG changes after zolpidem in mice. Neuroreport. 2004;15:2299–302. doi: 10.1097/00001756-200410050-00031. [DOI] [PubMed] [Google Scholar]
  15. Leon LR, Walker LD, DuBose DA, Stephenson LA. Biotelemetry transmitter implantation in rodents: impact on growth and circadian rhythms. Am J Physiol Regul Integr Comp Physiol. 2004;286:R967–74. doi: 10.1152/ajpregu.00380.2003. [DOI] [PubMed] [Google Scholar]
  16. Lo CC, Chou T, Penzel T, Scammell TE, Strecker RE, et al. Common scale-invariant patterns of sleep-wake transitions across mammalian species. Proc Natl Acad Sci U S A. 2004;101:17545–8. doi: 10.1073/pnas.0408242101. [DOI] [PMC free article] [PubMed] [Google Scholar]
  17. Lupi D, Oster H, Thompson S, Foster RG. The acute light-induction of sleep is mediated by OPN4-based photoreception. Nat Neurosci. 2008;11:1068–73. doi: 10.1038/nn.2179. [DOI] [PubMed] [Google Scholar]
  18. Maret S, Franken P, Dauvilliers Y, Ghyselinck NB, Chambon P, Tafti M. Retinoic acid signaling affects cortical synchrony during sleep. Science. 2005;310:111–3. doi: 10.1126/science.1117623. [DOI] [PubMed] [Google Scholar]
  19. Megens AA, Voeten J, Rombouts J, Meert TF, Niemegeers CJ. Behavioral activity of rats measured by a new method based on the piezo-electric principle. Psychopharmacology (Berl) 1987;93:382–8. doi: 10.1007/BF00187261. [DOI] [PubMed] [Google Scholar]
  20. Pack AI, Galante RJ, Maislin G, Cater J, Metaxas D, et al. Novel method for high-throughput phenotyping of sleep in mice. Physiol Genomics. 2007;28:232–8. doi: 10.1152/physiolgenomics.00139.2006. [DOI] [PubMed] [Google Scholar]
  21. Storch C, Hohne A, Holsboer F, Ohl F. Activity patterns as a correlate for sleep-wake behaviour in mice. J Neurosci Methods. 2004;133:173–9. doi: 10.1016/j.jneumeth.2003.10.008. [DOI] [PubMed] [Google Scholar]
  22. Tafti M, Franken P. Invited review: genetic dissection of sleep. J Appl Physiol. 2002;92:1339–47. doi: 10.1152/japplphysiol.00834.2001. [DOI] [PubMed] [Google Scholar]
  23. Tobler I. Is sleep fundamentally different between mammalian species? Behav Brain Res. 1995;69:35–41. doi: 10.1016/0166-4328(95)00025-o. [DOI] [PubMed] [Google Scholar]
  24. Tobler I, Gaus SE, Deboer T, Achermann P, Fischer M, et al. Altered circadian activity rhythms and sleep in mice devoid of prion protein. Nature. 1996;380:639–42. doi: 10.1038/380639a0. [DOI] [PubMed] [Google Scholar]
  25. Vanderwolf CH, Kolb B, Cooley RK. Behavior of the rat after removal of the neocortex and hippocampal formation. J Comp Physiol Psychol. 1978;92:156–75. doi: 10.1037/h0077447. [DOI] [PubMed] [Google Scholar]
  26. Weiergraber M, Henry M, Hescheler J, Smyth N, Schneider T. Electrocorticographic and deep intracerebral EEG recording in mice using a telemetry system. Brain Res Brain Res Protoc. 2005;14:154–64. doi: 10.1016/j.brainresprot.2004.12.006. [DOI] [PubMed] [Google Scholar]
  27. Winrow CJ, Williams DL, Kasarskis A, Millstein J, Laposky AD, et al. Uncovering the genetic landscape for multiple sleep-wake traits. PLoS One. 2009;4:e5161. doi: 10.1371/journal.pone.0005161. [DOI] [PMC free article] [PubMed] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Supplementary Materials

Supplementary Material

RESOURCES