Skip to main content
Journal of Intensive Care logoLink to Journal of Intensive Care
. 2015 Nov 19;3:50. doi: 10.1186/s40560-015-0117-0

Fluid responsiveness in acute circulatory failure

Ahmed Hasanin 1,
PMCID: PMC4653888  PMID: 26594361

Abstract

Although fluid resuscitation of patients having acute circulatory failure is essential, avoiding unnecessary administration of fluids in these patients is also important. Fluid responsiveness (FR) is defined as the ability of the left ventricle to increase its stroke volume (SV) in response to fluid administration. The objective of this review is to provide the recent advances in the detection of FR and simplify the physiological basis, advantages, disadvantages, and cut-off values for each method. This review also highlights the present gaps in literature and provides future thoughts in the field of FR.

Static methods are generally not recommended for the assessment of FR. Dynamic methods for the assessment of FR depend on heart-lung interactions. Pulse pressure variation (PPV) and stroke volume variation (SVV) are the most famous dynamic measures. Less-invasive dynamic parameters include plethysmographic-derived parameters, variation in blood flow in large arteries, and variation in the diameters of central veins. Dynamic methods for the assessment of FR have many limitations; the most important limitation is spontaneous breathing activity.

Fluid challenge techniques were able to overcome most of the limitations of the dynamic methods. Passive leg raising is the most popular fluid challenge method. More simple techniques have been recently introduced such as the mini-fluid challenge and 10-s fluid challenge. The main limitation of fluid challenge techniques is the need to trace the effect of the fluid challenges on SV (or any of its derivatives) using a real-time monitor. More research is needed in the field of FR taking into consideration not only the accuracy of the method but also the ease of implementation, the applicability on a wider range of patients, the time needed to apply each method, and the feasibility of its application by acute care physicians with moderate and low experience.

Keywords: Fluid responsiveness, Acute circulatory failure, Heart-lung interaction, Fluid challenge

Introduction

Fluid resuscitation is the cornerstone of managing patients having acute circulatory failure. Although restoring the volume status of a shocked patient is substantial, growing evidence indicates that unnecessary administration of fluids has a deleterious outcome [1].

Fluid responsiveness (FR) is defined as the ability of the left ventricle to increase its stroke volume (SV) in response to fluid administration [2]. Assessment of patient response to volume expansion presents a daily challenge for acute care physicians. FR has been extensively evaluated in various situations with acute circulatory failure such as septic shock, cardiac surgery, and other surgical procedures.

The objective of this review is to provide the recent advances in the detection of FR and simplify the physiological basis, advantages, disadvantages, and cut-off values for each method. The review also highlights the present gaps in literature and provides future thoughts in the field of FR.

The review is organized into the following sections:

  1. Static parameters and its disadvantages

  2. Dynamic parameters: physiological basis, different varieties, and limitations

  3. Fluid challenge methods: physiological basis, different varieties, and limitations

  4. Present gaps in the literature, conclusions, and future thoughts

Review

Static measures to assess FR

Measures

Pressures

Both central venous pressure (CVP) and pulmonary artery occlusion pressure (PAOP) were reported to be of a poor value in prediction of FR in both spontaneously breathing [3] and mechanically ventilated patients [46].

Areas and volumes

Although they were considered to be good indicators of preload [7], cardiac dimensions (left ventricular end diastolic area (LVEDA) and left ventricular end diastolic volumes (LVEDV)) were reported as poor predictors of FR [3, 6, 8].

Diameters

Inferior vena cava (IVC) maximum diameter (measured by ultrasound at the subcostal area) [9, 10] and vascular pedicle width (measured from chest X-ray) [11, 12] have gained popularity in the assessment of volume status. Moderate evidence is available suggesting that IVC diameter is lower in hypovolemic patients [9, 10]. The role of vascular pedicle width is more evident in patients with volume overload [12, 13]. There is no evidence suggesting the role of absolute IVC diameter or vascular pedicle width in the prediction of FR in shocked patients.

Limitations of static methods

Many reasons described why static parameters are of poor value in the prediction of FR. First, cardiac filling pressures represent intramural pressure; however, preload is determined by transmural pressure, which is affected by both intramural and extramural pressures [14]. Second, preload alone cannot predict FR because the response of a patient to fluids depends on both preload and cardiac contractility that varies between patients. Preload will predict FR only in cases with normal ventricular contractility [15].

Dynamic measures to assess FR

Physiological basis

FR is detected by inducing a change in the preload and subsequently monitoring the corresponding change in SV or one of its derivatives. This change in preload is achieved in dynamic measures by positive pressure ventilation. Positive pressure ventilation provokes a cyclic decrease in the right ventricular (RV) SV via two mechanisms:

  1. Decreased preload (decreased venous return)

  2. Increased afterload (increased transpulmonary pressure) [16].

RV stroke volume reaches its minimum value by the end of inspiration resulting in a consequent decrease in LV filling and thus LV stroke volume after a lag period of 2–3 heartbeats [17, 18].

Two other mechanisms were mentioned to antagonize the negative effect of mechanical ventilation on SV:

  1. Squeezing of blood out of alveolar vessels and thus transiently increasing LV preload [19]

  2. Inspiratory increase in pleural pressure that decreases LV afterload, enhancing LV ejection

However, experimental data suggest that the latter two mechanisms have a minor effect on LV stroke volume. Consequently, the net effect of positive pressure ventilation is decreasing RV stroke volume, LV filling, and LV stroke volume [16]. This decrease in SV is more prominent when the patient is on the steep part of cardiac contractility “Frank-Starling” curve (fluid responder).

Measures

Systolic pressure variation (SPV)

SPV is calculated by measuring the difference between both the maximal and the minimal values of systolic blood pressure (SBP) during a single respiratory cycle and a reference value (reference value is SBP measured at end expiratory pause) [16]. SPV was reported to increase with induction of hypovolemia in mechanically ventilated dogs [20], mechanically ventilated patients after aortic surgery [21], and patients with septic shock [22]. Denault et al. [23] reported SPV to be affected by airway and pleural pressures rather than volume status; however, a meta-analysis conducted by Marik et al. showed area under receiver operating characteristics (AUROC) = 0.86 for SPV for the detection of FR [6].

Pulse pressure variation (PPV)

PPV is calculated by dividing the largest PP (PPmax − PPmin) by the average PP (PPmax + PPmin/2). PPV above 13 % [24] is a good predictor of FR [25] [6]. AUROC was reported as 0.98 in a prospective cohort study [26] and 0.94 in a meta-analysis [6]. PPV has an advantage over SPV of not being affected by airway and pleural pressure because these pressures affect both SBP and diastolic blood pressure (DBP), whereby the PP (difference between SBP and DBP) remains unaffected [27]. In the intraoperative situation, PPV showed low accuracy with patients undergoing gastrointestinal (GIT) surgery [28]. PPV was accurate after cardiac surgery only when patients with low perfusion or right ventricular dysfunction were excluded [29].

Stroke volume variation (SVV)

SVV is commonly measured by PiCCO continuous cardiac output monitoring [30] or esophageal Doppler [31, 32]. It is calculated by dividing the difference between maximum SV and minimum SV (SVmax − SVmin) by their average (SVmax + SVmin/2) in a time window of 30 s. SVV was reported as a good predictor of FR in brain surgery patients [30], general surgical patients [32], septic shock patients [33], and after cardiac surgery [34]. SVV was not accurate with patients undergoing GIT surgery [28]. A recent meta-analysis reported SVV as a reliable predictor for FR in mechanically ventilated patients on tidal volume above 8 ml/kg with AUROC 0.84 [6]. The proper cut-off value was 14 % for SVV [32, 35] and 11 % for stroke output index [31].

Plethysmographic dynamic indices

Pulse oximetry plethysmographic waveform amplitude (POP) is measured using a special pulse oximetry sensor; plethysmographic variability index (PVI) is more easily measured using Masimo device. Both POP and PVI were reported in a recent meta-analysis as good indicators for FR in mechanically ventilated patients without cardiac arrhythmias, heart failure, or spontaneous activity with cut-off value 9.1–15 % [36]. PVI measured before induction of anesthesia predicted propofol-induced hypotension during induction of anesthesia [37]. PVI showed low accuracy in the detection of FR after cardiac surgery [29].

IVC respiratory variation

IVC variation is best assessed using ultrasound in the long-axis (sagittal) view. IVC diameter is measured 1 cm distal to its junction with hepatic vein either by 2-D or M modes [38]. Although data about IVC variation in FR are heterogeneous with regard to the type of patients, type of fluid, and definition of collapsibility index, there is a consensus that a cut-off value of 12–21 % for IVC variation is useful in the detection of FR in mechanically ventilated patients [39, 40]. In spontaneously breathing patients, a more cautious use was suggested by Muller and co-workers who reported IVC variability >40 % to predict FR. They also suggested that low values (<40 %) do not exclude FR [41].

SVC respiratory variation

SVC variation (measured using TEE) predicts FR with a cut-off value that ranged between 29 [40] and 36 % [42]. Variation in the peak flow velocity in SVC predicts FR at a cut-off value of 12.7 % [43].

Internal jugular vein (IJV) and subclavian vein respiratory variation

IJV distensibility measured using ultrasound was recently reported as a predictor of FR in mechanically ventilated patients with cut-off value 18 %. The combination of IJV distensibility of 9.7 % and PPV more than 12 % reaches a sensitivity of 100 % and specificity of 95 % [44]. A recent study reported IJV collapsibility index to overestimate the collapsibility when compared with IVC; they also reported a weak correlation between IJV and IVC collapsibility, raising a controversy about IJV use in the prediction of FR [45]. Subclavian vein collapsibility was also reported as an alternative method to detect FR with the advantage of having easy and fast access than IVC [46].

Subaortic velocity time integral (VTI) variation

Subaortic VTI variation was reported by Slama et al. as a predictor for FR in experimental animals [47]. However, it has not been tried in humans yet.

Aortic velocity variation

Respiratory variation of peak aortic velocity was reported as a good indicator for FR in critically ill patients under mechanical ventilation: the best cut-off value was 18 % when measured by esophageal Doppler [48] and 12 % when measured by trans-esophageal echocardiography [49]. In a study conducted by Guinot et al., peak aortic velocity measured by esophageal Doppler did not predict FR during surgery [32].

Carotid artery peak velocity variation

Carotid artery peak velocity variation measured using ultrasound was recently reported in two observational studies to predict FR in patients undergoing coronary artery bypass grafting (CABG) surgery [50] as well as patients with septic shock [51] with cut-off values 11 and 14 %, respectively.

A comparison between different dynamic methods is presented in Table 1.

Table 1.

Dynamic methods for the detection of FR

Parameter Cut-off value (%) Evidence Limitations
SPV [6, 16, 2023] NA Cohort Affected by airway and pleural pressure [17]
PPV [6, 2429] 13 Meta-analysis Needs special monitor; needs arterial line
SVV [6, 30, 3235] 14 Cohort Needs either arterial line (plus special monitor) or esophageal Doppler
SOI [31] 11 Cohort Needs esophageal Doppler
POP [36] 9.5–15 Meta-analysis Needs special pulse oximeter
PVI [36, 37] 9.5–15 Meta-analysis Needs Masimo device
IVC variation [3841] 12–21 Meta-analysis Needs ultrasound; difficult in abdominal surgical cases; cannot be used intraoperatively
SVC variation [4042] 29–36 Cohort Needs trans-esophageal echocardiography
IJV variation [44, 45] 18 Cohort Needs ultrasound
Subaortic VTI [47] NA Animal study Needs echocardiography; needs good operator experience; not tried in humans yet
Aortic velocity variation [48, 49] 12–18 Cohort Needs echocardiography or esophageal Doppler
Carotid velocity variation [50, 51] 11–14 Cohort Needs ultrasound

SPV systolic pressure variation, PPV pulse pressure variation, SVV stroke volume variation, SOI stroke output index, POP pulse oximetry plethysmographic waveform amplitude, PVI Plethysmographic variability index, IVC inferior vena cava, SVC superior vena cava, IJV internal jugular vein, VTI velocity time integral, NA not available

Limitation of dynamic measures

Spontaneous breathing

Spontaneous breathing is the most important limitation of dynamic methods. Failure of dynamic methods in detecting FR was reported in patients with spontaneous breathing [52, 53] as well as patients on pressure support ventilation [54]. This was explained by the dependence of dynamic parameters on regular variations in intrathoracic pressure, tidal volume, and rate; all these components are highly variable in spontaneous breathing patients in addition to the effect of abdominal muscle contractions (which is common with spontaneous breathing efforts) on the preload response [55].

Ventilator-related causes

Dynamic parameters poorly detect FR with tidal volumes below 8 ml/kg [56, 57] and patients with low airway driving pressure below 20 cm/H2O [58]. This was explained by the fact that low tidal volume induces small variation in thoracic pressure and consequently small changes in preload [59]. With tidal volumes below 8 ml/kg, FR is present even with lower PPV. The cut-off value for prediction of FR with low tidal volumes should be 8 % and not 12 % as in higher tidal volumes [56]. Failure of dynamic methods was also reported in cases with high-frequency ventilation; this is because the low number of cardiac cycles per respiratory cycle will not allow respiratory variation in SV to occur [60].

Low lung compliance

Dynamic methods for the detection of FR were reported to be of low value in cases of reduced lung compliance, especially in cases of low PPV [26, 59, 61]; however, the presence of high PPV in patients of acute respiratory distress syndrome (ARDS) is an indicator of FR when patient tidal volume is above 8 ml/kg [59].

Elevated pulmonary artery pressure

PPV poorly predicted FR in patients with elevated pulmonary artery pressure. These patients usually do not respond to fluid resuscitation [62].

Cardiac causes

Dynamic measures are not valid in cases having cardiac arrhythmias [63], and variation in SV in these cases is influenced by irregular rhythm rather than heart-lung interactions. PPV was not able to predict FR in patients with elevated LV pressure (defined as E/E’ > 15) [64]. Both PVV and SVV were altered by propranolol-induced acute ventricular failure in mongrel dogs [65].

Open-chest conditions

Neither PPV nor SVV was able to predict FR under open-chest conditions; this was reported in patients undergoing CABG surgery during thoracotomy. Dynamic methods showed good performance in the same patient group after chest closure [66].

Intra-abdominal hypertension

Increased intra-abdominal pressure above 10.5 mmHg impairs the accuracy of PPV [67].

A 1-day prospective multicenter study reported that only 2 % of patients with acute circulatory failure in the ICU have fulfilled the validity criteria for valid application of PPV. This finding increases the interest in fluid challenge methods to overcome the known limitations for dynamic methods especially outside the operating room [68].

Preload and fluid challenge

Physiological basis

Fluid challenge methods are done by administration of a fluid bolus (either extrinsically or intrinsically) and monitoring the resulting effect on SV or cardiac output (CO). Fluid responders are patients with 15 % increase in SV or CO after fluid challenge [25]. SV and CO can be measured using transpulmonary thermodilution, pulse contour analysis [25], bioreactance [69], and echocardiography (through measuring subaortic VTI) [25]. Alternative parameters to detect patient response to passive leg raising (PLR) include the following: decreased PPV and SVV [70], increased radial pulse pressure (by 10 %), femoral artery peak velocity [71], carotid artery diameter, and peak velocity [69].

Recently, indirect methods of measurement of the CO response to PLR were introduced. Those include end-tidal CO2 (5 % increase) [72], mixed venous oxygen saturation (2 % increase) [73], sublingual microcirculatory perfusion, and skin perfusion [74].

Measures

Passive leg raising

PLR creates a transient increase in the preload via translocation of venous blood from the lower limbs to the thorax. It has been described as an attractive method of fluid challenge having the advantage of being a “self-volume challenge” and a “reversible fluid challenge” [53]. PLR-induced increase in SV (or its derivatives) can determine FR in most situations that dynamic methods fail to deal with such as spontaneous breathing, decreased respiratory compliance, and cardiac arrhythmias [26, 75]. The best cut-off value for detecting FR is increased in aortic blood flow by 10 % (using esophageal Doppler) [53] or increased cardiac index by 10 % (using thermodilution) [26] after PLR.

End expiratory occlusion

EEO is done by interrupting mechanical ventilation at the end expiratory pause for 15 s with monitoring SV or its derivatives [76]. EEO is considered another method for “self-fluid challenge” as it attenuates the inspiratory increase in thoracic pressure resulting in increasing the venous return [76]. EEO-induced increase in CO by 5 % was reported to predict FR in most patients in whom dynamic measures fail such as patients with arrhythmias [76], decreased respiratory compliance [26], and ARDS patients [77]. EEO can be used in patients with spontaneous breathing activity unless excessive triggering results into test interruption [78].

EEO showed the same accuracy as PLR when the response to both of them was assessed using cardiac index. EEO was superior to PLR if the response was assessed by changes in arterial pulse pressure; this was explained by PLR-induced change in arterial compliance, which impairs the ability of arterial pulse pressure to reflect the changes in SV with PLR [76]. However, PLR has the advantage over EEO in being applicable in non-intubated patients [76]. Although Guinot et al. reported a poor value for EEO in the prediction of FR in the operating theater, this finding was reported in operated patients with no signs of shock [79].

PEEP-induced hemodynamic changes

Increasing PEEP by 10 cm H2O produces a hemodynamic effect that is near to EEO. Geerts et al. reported that FR can be predicted in cardiac surgery patients if increasing PEEP by 10 cm H2O for 5 min produced an increase in CVP with AUROC = 0.99; however, no data is available about the cut-off value of the change in CVP that would predict FR [80]. This method has an advantage over EEO of not being affected by ventilator conditions, easily done in ICU patients with no need for any advanced monitors.

Another method for the detection of FR was reported by Wilkman et al. in patients with septic shock by increasing PEEP from 10 to 20 cm H2O and following their MAP. A negative predictive value was 100 %, so the absence of decrease of MAP during PEEP elevation can identify non-responders [81].

Arm occlusion pressure

Arm occlusion pressure is defined as “the radial artery pressure after 35 s occlusion by a blood pressure cuff”; it is measured using an arterial catheter. Arm occlusion pressure is considered as an indicator of mean filling pressure and volume status of the upper limb. Arm occlusion pressure less than 21.9 mmHg detected FR in cardiac surgery patients [82].

Mini-fluid challenge

Mini-fluid challenge is performed by infusing 100 ml colloids over 1 min with concomitant monitoring of aortic VTI. An increase in VTI by 10 % after mini-fluid challenge predicts FR [83].

Ten-second fluid challenge

Infusion of 50 ml crystalloids with monitoring of CO or SV was recently reported as a method for the detection of FR. The best cut-off value was 9 % increase in CO or SV after fluid administration [84].

A comparison between different methods for fluid challenge is described in Table 2.

Table 2.

Fluid challenge methods for the detection of FR

Parameter Cut-off value Evidence Limitations
PLR [26, 53, 75] 10 % increase in aortic flow or CI Meta-analysis Not feasible in intraoperative situations and some surgical patients; needs CO monitoring
EEO [26, 7679] 5 % increase in CO Cohort Needs MV; needs CO monitoring
PEEP-induced increase in CVP [80] 1.5 mmHg Cohort Tried only in cardiac surgery patients
PEEP-induced decrease in MAP [81] NA Cohort Useful only in identifying non-responders
Arm occlusion pressure [82] 21.9 mmHg Cohort Tried only in cardiac surgery patients
Mini-fluid challenge [83] 10 % increase in subaortic VTI Cohort Needs echocardiography with experienced operator
10-s fluid challenge [84] 9 % increase in CO or SV Cohort Needs CO or SV monitoring

PLR passive leg raising, EEO end expiratory occlusion, PEEP positive end expiratory pressure, CVP central venous pressure, MAP mean arterial pressure, CO cardiac output, CI cardiac index, SV stroke volume, BP blood pressure, VTI velocity time integral, NA not available

Limitations of fluid challenge techniques

The main limitation in using fluid challenge methods for the detection of FR is the need for real-time monitoring of SV or CO to differentiate fluid responders. Alternative less-invasive parameters are being introduced to trace patient response to PLR such as end-tidal CO2 [72] and peak velocity in different arteries measured by ultrasound [69, 71].

Effect of vasopressors on different methods for the detection of FR

Norepinephrine infusion decreases PPV and SVV, masking their ability for the detection of FR. This finding was addressed in two experimental animal studies on dogs [85] and pigs [86]. Moreover, measurement of SV using FloTrac/Vigileo System is not accurate under conditions with increased vasomotor tone due to phenylephrine infusion [87]. On the contrary, the PLR test kept its value as a predictor of FR in patients with septic shock even after increasing norepinephrine dose [88].

Present gaps in the literature

Four problems with FR still need to be solved:

  1. Most of the dynamic methods for the detection of FR need invasive monitoring by an arterial line (except plethysmographic indices and ultrasound indices); less-invasive methods are needed.

  2. Most of the fluid challenge techniques need real-time SV monitoring (or VTI monitoring using echocardiography); more simple monitors are needed.

  3. Methods suitable for intraoperative use are still limited.

  4. The ease of application for any method by a non-expert physician should be considered.

Conclusions

Static methods are generally not recommended for the detection of FR. Dynamic methods rely on heart-lung interactions. Dynamic methods are accurate and reliable; however, these measures are useful in few selected types of patients. PPV and SVV are the most popular dynamic methods. Further research is needed for introducing less-invasive dynamic methods with fewer limitations.

Fluid challenge methods were able to overcome most of the limitations of dynamic methods; however, these methods need a real-time monitoring for SV or one of its derivatives. PLR is considered to be the standard method for fluid challenge. Recent publications described more simple methods (e.g., 10-s fluid challenge, carotid artery peak velocity variation). These new methods still need more validation in different types of patients. Validation is also needed for more simple methods for tracing SV response to fluids.

Comparing various methods for the detection of FR should take into consideration not only the accuracy of the method but also the ease of implementation, the applicability on a wider range of patients, the time needed to apply each method, and the feasibility of its application by acute care physicians with moderate and low experience.

Acknowledgements

I would like to thank Dr Ahmed Mukhtar, professor of Anesthesia and Critical Care Medicine, and Dr Amr Kamal, assistant lecturer of Anesthesia and Critical Care Medicine, for their kind help in writing this article.

Abbreviations

ABP

arterial blood pressure

ARDS

acute respiratory distress syndrome

AUROC

area under receiver operating characteristics

CABG

coronary artery bypass grafting

CO

cardiac output

Co2

carbon dioxide

CVP

central venous pressure

DBP

diastolic blood pressure

EEO

end expiratory occlusion

FR

fluid responsiveness

ICU

intensive care unit

IVC

inferior vena cava

LV

left ventricular

LVEDA

left ventricular end diastolic area

LVEDV

left ventricular end diastolic volumes

MAP

mean arterial pressure

PAOP

pulmonary artery occlusion pressure

PEEP

positive end expiratory pressure

PLR

passive leg raising

POP

pulse oximetry plethysmographic waveform amplitude

PPV

pulse pressure variation

PVI

plethysmographic variability index

RV

right ventricular

SBP

systolic blood pressure

SPV

systolic pressure variation

SV

stroke volume

SVC

superior vena cava

Svo2

ventral venous oxygen saturation

SVV

stroke volume variation

TEE

trans-esophageal echocardiography

TTE

trans-thoracic echocardiography

VTI

velocity time integral

Footnotes

Competing interests

The author declares that he has no competing interests.

References

  • 1.Vincent J-L, Sakr Y, Sprung CL, Ranieri VM, Reinhart K, Gerlach H, et al. Sepsis in European intensive care units: results of the SOAP study. Crit Care Med. 2006;34:344–53. doi: 10.1097/01.CCM.0000194725.48928.3A. [DOI] [PubMed] [Google Scholar]
  • 2.Huang C-C, Fu J-Y, Hu H-C, Kao K-C, Chen N-H, Hsieh M-J, et al. Prediction of fluid responsiveness in acute respiratory distress syndrome patients ventilated with low tidal volume and high positive end-expiratory pressure. Crit Care Med. 2008;36:2810–6. doi: 10.1097/CCM.0b013e318186b74e. [DOI] [PubMed] [Google Scholar]
  • 3.Coudray A, Romand J-A, Treggiari M, Bendjelid K. Fluid responsiveness in spontaneously breathing patients: a review of indexes used in intensive care. Crit Care Med. 2005;33:2757–62. doi: 10.1097/01.CCM.0000189942.24113.65. [DOI] [PubMed] [Google Scholar]
  • 4.Osman D, Ridel C, Ray P, Monnet X, Anguel N, Richard C, et al. Cardiac filling pressures are not appropriate to predict hemodynamic response to volume challenge. Crit Care Med. 2007;35:64–8. doi: 10.1097/01.CCM.0000249851.94101.4F. [DOI] [PubMed] [Google Scholar]
  • 5.Marik PE, Cavallazzi R. Does the central venous pressure predict fluid responsiveness? An updated meta-analysis and a plea for some common sense. Crit Care Med. 2013;41:1774–81. doi: 10.1097/CCM.0b013e31828a25fd. [DOI] [PubMed] [Google Scholar]
  • 6.Marik PE, Cavallazzi R, Vasu T, Hirani A. Dynamic changes in arterial waveform derived variables and fluid responsiveness in mechanically ventilated patients: a systematic review of the literature. Crit Care Med. 2009;37:2642–7. doi: 10.1097/CCM.0b013e3181a590da. [DOI] [PubMed] [Google Scholar]
  • 7.Kumar A, Anel R, Bunnell E, Habet K, Zanotti S, Marshall S, et al. Pulmonary artery occlusion pressure and central venous pressure fail to predict ventricular filling volume, cardiac performance, or the response to volume infusion in normal subjects. Crit Care Med. 2004;32:691–9. doi: 10.1097/01.CCM.0000114996.68110.C9. [DOI] [PubMed] [Google Scholar]
  • 8.Lamia B, Ochagavia A, Monnet X, Chemla D, Richard C, Teboul J-L. Echocardiographic prediction of volume responsiveness in critically ill patients with spontaneously breathing activity. Intensive Care Med. 2007;33:1125–32. doi: 10.1007/s00134-007-0646-7. [DOI] [PubMed] [Google Scholar]
  • 9.Dipti A, Soucy Z, Surana A, Chandra S. Role of inferior vena cava diameter in assessment of volume status: a meta-analysis. Am J Emerg Med. 2012;30:1414–9. doi: 10.1016/j.ajem.2011.10.017. [DOI] [PubMed] [Google Scholar]
  • 10.Zengin S, Al B, Genc S, Yildirim C, Ercan S, Dogan M, et al. Role of inferior vena cava and right ventricular diameter in assessment of volume status: a comparative study: ultrasound and hypovolemia. Am J Emerg Med. 2013;31:763–7. doi: 10.1016/j.ajem.2012.10.013. [DOI] [PubMed] [Google Scholar]
  • 11.Miller RR, Ely EW. Radiographic measures of intravascular volume status: the role of vascular pedicle width. Curr Opin Crit Care. 2006;12:255–62. doi: 10.1097/01.ccx.0000224871.31947.8d. [DOI] [PubMed] [Google Scholar]
  • 12.Wichansawakul S, Vilaichone W, Tongyoo S, Permpikul C, Wonglaksanapimol S, Daengnim K, et al. Evaluation of correlation between vascular pedicle width and intravascular volume status in Thai critically ill patients. J Med Assoc Thai. 2011;94(Suppl 1):S181–7. [PubMed] [Google Scholar]
  • 13.Wang H, Shi R, Mahler S, Gaspard J, Gorchynski J, D’Etienne J, et al. Vascular pedicle width on chest radiograph as a measure of volume overload: meta-analysis. West J Emerg Med. 2011;12:426–32. doi: 10.5811/westjem.2011.3.2023. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 14.Cherpanath TG V, Lagrand WK, Schultz MJ, Groeneveld ABJ. Cardiopulmonary interactions during mechanical ventilation in critically ill patients. Netherlands Hear J. 2013;21:166–72. doi: 10.1007/s12471-013-0383-1. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 15.Braunwald E, Sonnenblick EH RJ. Mechanisms of cardiac contraction and relaxation. In: Braunwald E, editor. heart disease. Philadelphia: Saunders; 1998. pp. 389–425. [Google Scholar]
  • 16.Michard F, Teboul JL. Using heart-lung interactions to assess fluid responsiveness during mechanical ventilation. Crit Care. 2000;4:282–9. doi: 10.1186/cc710. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 17.Jardin F, Farcot JC, Gueret P, Prost JF, Ozier Y, Bourdarias JP. Cyclic changes in arterial pulse during respiratory support. Circulation. 1983;68:266–74. doi: 10.1161/01.CIR.68.2.266. [DOI] [PubMed] [Google Scholar]
  • 18.Scharf SM, Brown R, Saunders N, Green LH. Hemodynamic effects of positive-pressure inflation. J Appl Physiol. 1980;49:124–31. doi: 10.1152/jappl.1980.49.1.124. [DOI] [PubMed] [Google Scholar]
  • 19.Brower R, Wise RA, Hassapoyannes C, Bromberger-Barnea B, Permutt S. Effect of lung inflation on lung blood volume and pulmonary venous flow. J Appl Physiol. 1985;58:954–63. doi: 10.1063/1.336172. [DOI] [PubMed] [Google Scholar]
  • 20.Perel A, Pizov R, Cotev S. Systolic blood pressure variation is a sensitive indicator of hypovolemia in ventilated dogs subjected to graded hemorrhage. Anesthesiology. 1987;67:498–502. doi: 10.1097/00000542-198710000-00009. [DOI] [PubMed] [Google Scholar]
  • 21.Coriat P, Vrillon M, Perel A, Baron JF, Le Bret F, Saada M, et al. A comparison of systolic blood pressure variations and echocardiographic estimates of end-diastolic left ventricular size in patients after aortic surgery. Anesth Analg. 1994;78:46–53. doi: 10.1213/00000539-199401000-00009. [DOI] [PubMed] [Google Scholar]
  • 22.Tavernier B, Makhotine O, Lebuffe G, Dupont J, Scherpereel P. Systolic pressure variation as a guide to fluid therapy in patients with sepsis-induced hypotension. Anesthesiology. 1998;89:1313–21. doi: 10.1097/00000542-199812000-00007. [DOI] [PubMed] [Google Scholar]
  • 23.Denault AY, Gasior TA, Gorcsan J, Mandarino WA, Deneault LG, Pinsky MR. Determinants of aortic pressure variation during positive-pressure ventilation in man. Chest. 1999;116:176–86. doi: 10.1378/chest.116.1.176. [DOI] [PubMed] [Google Scholar]
  • 24.Goarin JP, Lehot J, Ph D, Vallet B, Tavernier B. Assessing the diagnostic accuracy of pulse pressure. Anesthesiology. 2011;89:231–41. doi: 10.1097/ALN.0b013e318225b80a. [DOI] [PubMed] [Google Scholar]
  • 25.Yang X, Du B. Does pulse pressure variation predict fluid responsiveness in critically ill patients? A systematic review and meta-analysis. Crit Care. 2014;18:650. doi: 10.1186/s13054-014-0650-6. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 26.Monnet X, Bleibtreu A, Ferré A, Dres M, Gharbi R, Richard C, et al. Passive leg-raising and end-expiratory occlusion tests perform better than pulse pressure variation in patients with low respiratory system compliance. Crit Care Med. 2012;40:152–7. doi: 10.1097/CCM.0b013e31822f08d7. [DOI] [PubMed] [Google Scholar]
  • 27.Theres H, Binkau J, Laule M, Heinze R, Hundertmark J, Blobner M, et al. Phase-related changes in right ventricular cardiac output under volume-controlled mechanical ventilation with positive end-expiratory pressure. Crit Care Med. 1999;27:953–8. doi: 10.1097/00003246-199905000-00033. [DOI] [PubMed] [Google Scholar]
  • 28.MacDonald N, Ahmad T, Mohr O, Kirk-Bayley J, Moppett I, Hinds CJ, et al. Dynamic preload markers to predict fluid responsiveness during and after major gastrointestinal surgery: an observational substudy of the OPTIMISE trial. Br J Anaesth. 2014;114:598–604. doi: 10.1093/bja/aeu398. [DOI] [PubMed] [Google Scholar]
  • 29.Fischer M-O, Pelissier A, Bohadana D, Gérard J-L, Hanouz J-L, Fellahi J-L. Prediction of responsiveness to an intravenous fluid challenge in patients after cardiac surgery with cardiopulmonary bypass: a comparison between arterial pulse pressure variation and digital plethysmographic variability index. J Cardiothorac Vasc Anesth. 2013;27:1087–93. doi: 10.1053/j.jvca.2013.02.024. [DOI] [PubMed] [Google Scholar]
  • 30.Berkenstadt H, Margalit N, Hadani M, Friedman Z, Segal E, Villa Y, et al. Stroke volume variation as a predictor of fluid responsiveness in patients undergoing brain surgery. Anesth Analg. 2001;92:984–9. doi: 10.1097/00000539-200104000-00034. [DOI] [PubMed] [Google Scholar]
  • 31.Vallée F, Fourcade O, De Soyres O, Angles O, Sanchez-Verlaan P, Pillard F, et al. Stroke output variations calculated by esophageal Doppler is a reliable predictor of fluid response. Intensive Care Med. 2005;31:1388–93. doi: 10.1007/s00134-005-2768-0. [DOI] [PubMed] [Google Scholar]
  • 32.Guinot PG, De Broca B, Abou Arab O, Diouf M, Badoux L, Bernard E, et al. Ability of stroke volume variation measured by oesophageal Doppler monitoring to predict fluid responsiveness during surgery. Br J Anaesth. 2013;110:28–33. doi: 10.1093/bja/aes301. [DOI] [PubMed] [Google Scholar]
  • 33.Khwannimit B, Bhurayanontachai R. Prediction of fluid responsiveness in septic shock patients: comparing stroke volume variation by FloTrac/Vigileo and automated pulse pressure variation. Eur J Anaesthesiol. 2012;29:64–9. doi: 10.1097/EJA.0b013e32834b7d82. [DOI] [PubMed] [Google Scholar]
  • 34.Reuter DA, Kirchner A, Felbinger TW, Weis FC, Kilger E, Lamm P, et al. Usefulness of left ventricular stroke volume variation to assess fluid responsiveness in patients with reduced cardiac function. Crit Care Med. 2003;31:1399–404. doi: 10.1097/01.CCM.0000059442.37548.E1. [DOI] [PubMed] [Google Scholar]
  • 35.Cannesson M, Tran NP, Cho M, Hatib F, Michard F. Predicting fluid responsiveness with stroke volume variation despite multiple extrasystoles. Crit Care Med. 2012;40:193–8. doi: 10.1097/CCM.0b013e31822ea119. [DOI] [PubMed] [Google Scholar]
  • 36.Sandroni C, Cavallaro F, Marano C, Falcone C, De Santis P, Antonelli M. Accuracy of plethysmographic indices as predictors of fluid responsiveness in mechanically ventilated adults: a systematic review and meta-analysis. Intensive Care Med. 2012;38:1429–37. doi: 10.1007/s00134-012-2621-1. [DOI] [PubMed] [Google Scholar]
  • 37.Tsuchiya M, Yamada T, Asada A. Pleth variability index predicts hypotension during anesthesia induction. Acta Anaesthesiol Scand. 2010;54:596–602. doi: 10.1111/j.1399-6576.2010.02225.x. [DOI] [PubMed] [Google Scholar]
  • 38.Evans D, Ferraioli G, Snellings J, Levitov A. Volume responsiveness in critically ill patients. J Ultrasound Med. 2014;33:3–7. doi: 10.7863/ultra.33.1.3. [DOI] [PubMed] [Google Scholar]
  • 39.Zhang Z, Xu X, Ye S, Xu L. Review ultrasonographic measurement of the respiratory variation in the inferior vena cava diameter is predictive of fluid responsiveness in critically ill patients : systematic review and meta-analysis. Ultrasound Med Biol. 2014;40:845–53. doi: 10.1016/j.ultrasmedbio.2013.12.010. [DOI] [PubMed] [Google Scholar]
  • 40.Charbonneau H, Riu B, Faron M, Mari A, Kurrek MM, Ruiz J, et al. Predicting preload responsiveness using simultaneous recordings of inferior and superior vena cavae diameters. Crit Care. 2014;18:473. doi: 10.1186/s13054-014-0473-5. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 41.Muller L, Bobbia X, Toumi M, Louart G, Molinari N, Ragonnet B, et al. Respiratory variations of inferior vena cava diameter to predict fluid responsiveness in spontaneously breathing patients with acute circulatory failure: need for a cautious use. Crit Care. 2012;16:R188. doi: 10.1186/cc11672. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 42.Vieillard-Baron A, Chergui K, Rabiller A, Peyrouset O, Page B, Beauchet A, et al. Superior vena caval collapsibility as a gauge of volume status in ventilated septic patients. Intensive Care Med. 2004;30:1734–9. doi: 10.1007/s00134-004-2361-y. [DOI] [PubMed] [Google Scholar]
  • 43.Guo Z, He W, Hou J, Li T, Zhou H, Xu Y, et al. The assessment of ultrasonic measurement of superior vena cava blood flow for the volume responsiveness of patients with mechanical ventilation. Zhonghua Wei Zhong Bing Ji Jiu Yi Xue. 2014;26:624–8. doi: 10.3760/cma.j.issn.2095-4352.2014.09.004. [DOI] [PubMed] [Google Scholar]
  • 44.Guarracino F, Ferro B, Forfori F, Bertini P, Magliacano L, Pinsky MR. Jugular vein distensibility predicts fluid responsiveness in septic patients. Crit Care. 2014;18:647. doi: 10.1186/s13054-014-0647-1. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 45.Kent A, Patil P, Davila V, Bailey JK, Jones C, Evans DC, et al. Sonographic evaluation of intravascular volume status: can internal jugular or femoral vein collapsibility be used in the absence of IVC visualization? Ann Thorac Med. 2015;10:44–9. doi: 10.4103/1817-1737.146872. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 46.Kent A, Bahner DP, Boulger CT, Eiferman DS, Adkins EJ, Evans DC, et al. Sonographic evaluation of intravascular volume status in the surgical intensive care unit: a prospective comparison of subclavian vein and inferior vena cava collapsibility index. J Surg Res. 2013;184:561–6. doi: 10.1016/j.jss.2013.05.040. [DOI] [PubMed] [Google Scholar]
  • 47.Slama M, Masson H, Teboul J-L, Arnout M-L, Susic D, Frohlich E, et al. Respiratory variations of aortic VTI: a new index of hypovolemia and fluid responsiveness. Am J Physiol Hear Circ Physiol. 2002;283:1729–33. doi: 10.1152/ajpheart.00308.2002. [DOI] [PubMed] [Google Scholar]
  • 48.Monnet X, Rienzo M, Osman D, Anguel N, Richard C, Pinsky MR, et al. Esophageal Doppler monitoring predicts fluid responsiveness in critically ill ventilated patients. Intensive Care Med. 2005;31:1195–201. doi: 10.1007/s00134-005-2731-0. [DOI] [PubMed] [Google Scholar]
  • 49.Feissel M, Michard F, Mangin I, Ruyer O, Faller JP, Teboul JL. Respiratory changes in aortic blood velocity as an indicator of fluid responsiveness in ventilated patients with septic shock. Chest. 2001;119:867–73. doi: 10.1378/chest.119.3.867. [DOI] [PubMed] [Google Scholar]
  • 50.Song Y, Kwak YL, Song JW, Kim YJ, Shim JK. Respirophasic carotid artery peak velocity variation as a predictor of fluid responsiveness in mechanically ventilated patients with coronary artery disease. Br J Anaesth. 2014;113:61–6. doi: 10.1093/bja/aeu057. [DOI] [PubMed] [Google Scholar]
  • 51.Ibarra-estrada MÁ, López-pulgarín JA, Mijangos-méndez JC, Díaz-gómez JL. Respiratory variation in carotid peak systolic velocity predicts volume responsiveness in mechanically ventilated patients with septic shock: a prospective cohort study. Crit Ultrasound J. 2015;7:29. doi: 10.1186/s13089-015-0029-1. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 52.Heenen S, De Backer D, Vincent J. How can the response to volume expansion in patients with spontaneous respiratory movements be predicted? Crit Care. 2006;10:R102. doi: 10.1186/cc4970. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 53.Monnet X, Rienzo M, Osman D, Anguel N, Richard C, Pinsky MR, et al. Passive leg raising predicts fluid responsiveness in the critically ill. Crit Care Med. 2006;34:1402–7. doi: 10.1097/01.CCM.0000215453.11735.06. [DOI] [PubMed] [Google Scholar]
  • 54.Perner A, Faber T. Stroke volume variation does not predict fluid responsiveness in patients with septic shock on pressure support ventilation. Acta Anaesthesiol Scand. 2006;50:1068–73. doi: 10.1111/j.1399-6576.2006.01120.x. [DOI] [PubMed] [Google Scholar]
  • 55.De Backer D, Pinsky MR. Can one predict fluid responsiveness in spontaneously breathing patients? Intensive Care Med. 2007;33:1111–3. doi: 10.1007/s00134-007-0645-8. [DOI] [PubMed] [Google Scholar]
  • 56.De Backer D, Heenen S, Piagnerelli M, Koch M, Vincent J-L. Pulse pressure variations to predict fluid responsiveness: influence of tidal volume. Intensive Care Med. 2005;31:517–23. doi: 10.1007/s00134-005-2586-4. [DOI] [PubMed] [Google Scholar]
  • 57.Charron C, Fessenmeyer C, Cosson C, Mazoit J-X, Hebert J-L, Benhamou D, et al. The influence of tidal volume on the dynamic variables of fluid responsiveness in critically ill patients. Anesth Analg. 2006;102:1511–7. doi: 10.1213/01.ane.0000209015.21418.f4. [DOI] [PubMed] [Google Scholar]
  • 58.Muller L, Louart G, Bousquet P-J, Candela D, Zoric L, de La Coussaye J-E, et al. The influence of the airway driving pressure on pulsed pressure variation as a predictor of fluid responsiveness. Intensive Care Med. 2010;36:496–503. doi: 10.1007/s00134-009-1686-y. [DOI] [PubMed] [Google Scholar]
  • 59.Teboul JL, Monnet X. Pulse pressure variation and ARDS. Minerva Anestesiol. 2013;79:398–407. [PubMed] [Google Scholar]
  • 60.De Backer D, Taccone FS, Holsten R, Ibrahimi F, Vincent J-L. Influence of respiratory rate on stroke volume variation in mechanically ventilated patients. Anesthesiology. 2009;110:1092–7. doi: 10.1097/ALN.0b013e31819db2a1. [DOI] [PubMed] [Google Scholar]
  • 61.Lefrant J-Y, De Backer D. Can we use pulse pressure variations to predict fluid responsiveness in patients with ARDS? Intensive Care Med. 2009;35:966–8. doi: 10.1007/s00134-009-1479-3. [DOI] [PubMed] [Google Scholar]
  • 62.Wyler Von Ballmoos M, Takala J, Roeck M, Porta F, Tueller D, Ganter CC, et al. Pulse-pressure variation and hemodynamic response in patients with elevated pulmonary artery pressure: a clinical study. Crit Care. 2010;14:R111. doi: 10.1186/cc9060. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 63.Cherpanath TG V, Geerts BF, Lagrand WK, Schultz MJ, Groeneveld ABJ. Basic concepts of fluid responsiveness. Neth Heart J. 2013;21:530–6. doi: 10.1007/s12471-013-0487-7. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 64.Shim J-K, Song J-W, Song Y, Kim J-H, Kang H-M, Kwak Y-L. Pulse pressure variation is not a valid predictor of fluid responsiveness in patients with elevated left ventricular filling pressure. J Crit Care. 2014;29:987–91. doi: 10.1016/j.jcrc.2014.07.005. [DOI] [PubMed] [Google Scholar]
  • 65.Mesquida J, Kim HK, Pinsky MR. Effect of tidal volume, intrathoracic pressure, and cardiac contractility on variations in pulse pressure, stroke volume, and intrathoracic blood volume. Intensive Care Med. 2011;37:1672–9. doi: 10.1007/s00134-011-2304-3. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 66.De Waal EEC, Rex S, Kruitwagen CLJJ, Kalkman CJ, Buhre WF. Dynamic preload indicators fail to predict fluid responsiveness in open-chest conditions. Crit Care Med. 2009;37:510–5. doi: 10.1097/CCM.0b013e3181958bf7. [DOI] [PubMed] [Google Scholar]
  • 67.Royer P, Bendjelid K, Valentino R, Résière D, Chabartier C, Mehdaoui H. Influence of intra-abdominal pressure on the specificity of pulse pressure variations to predict fluid responsiveness. J Trauma Acute Care Surg. 2015;78:994–9. doi: 10.1097/TA.0000000000000605. [DOI] [PubMed] [Google Scholar]
  • 68.Mahjoub Y, Lejeune V, Muller L, Perbet S, Zieleskiewicz L, Bart F, et al. Evaluation of pulse pressure variation validity criteria in critically ill patients: a prospective observational multicentre point-prevalence study. Br J Anaesth. 2014;112:681–5. doi: 10.1093/bja/aet442. [DOI] [PubMed] [Google Scholar]
  • 69.Marik PE, Levitov A, Young A, Andrews L. The use of bioreactance and carotid Doppler to determine volume responsiveness and blood flow redistribution following passive leg raising in hemodynamically unstable patients. Chest. 2013;143:364–70. doi: 10.1378/chest.12-1274. [DOI] [PubMed] [Google Scholar]
  • 70.Mallat J, Meddour M, Durville E, Lemyze M, Pepy F, Temime J, et al. Decrease in pulse pressure and stroke volume variations after mini-fluid challenge accurately predicts fluid responsiveness. Br J Anaesth. 2015;115:449–56. doi: 10.1093/bja/aev222. [DOI] [PubMed] [Google Scholar]
  • 71.Préau S, Saulnier F, Dewavrin F, Durocher A, Chagnon J-L. Passive leg raising is predictive of fluid responsiveness in spontaneously breathing patients with severe sepsis or acute pancreatitis. Crit Care Med. 2010;38:819–25. doi: 10.1097/CCM.0b013e3181c8fe7a. [DOI] [PubMed] [Google Scholar]
  • 72.Monnet X, Bataille A, Magalhaes E, Barrois J, Le Corre M, Gosset C, et al. End-tidal carbon dioxide is better than arterial pressure for predicting volume responsiveness by the passive leg raising test. Intensive Care Med. 2013;39:93–100. doi: 10.1007/s00134-012-2693-y. [DOI] [PubMed] [Google Scholar]
  • 73.Kuiper AN, Trof RJ, Groeneveld ABJ. Mixed venous O2 saturation and fluid responsiveness after cardiac or major vascular surgery. J Cardiothorac Surg. 2013;8:189. doi: 10.1186/1749-8090-8-189. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 74.Klijn E, van Velzen MHN, Lima AP, Bakker J, van Bommel J, Groeneveld ABJ. Tissue perfusion and oxygenation to monitor fluid responsiveness in critically ill, septic patients after initial resuscitation: a prospective observational study. J Clin Monit Comput. 2015 Jan 20; [Epup ahead of print] [DOI] [PMC free article] [PubMed]
  • 75.Cavallaro F, Sandroni C, Marano C, La Torre G, Mannocci A, De Waure C, et al. Diagnostic accuracy of passive leg raising for prediction of fluid responsiveness in adults: systematic review and meta-analysis of clinical studies. Intensive Care Med. 2010;36:1475–83. doi: 10.1007/s00134-010-1929-y. [DOI] [PubMed] [Google Scholar]
  • 76.Monnet X, Osman D, Ridel C, Lamia B, Richard C, Teboul J. Predicting volume responsiveness by using the end-expiratory occlusion in mechanically ventilated intensive care unit patients. Crit Care Med. 2009;37:951–6. doi: 10.1097/CCM.0b013e3181968fe1. [DOI] [PubMed] [Google Scholar]
  • 77.Silva S, Jozwiak M, Teboul J, Persichini R, Richard C, Monnet X. End-expiratory occlusion test predicts preload responsiveness independently of positive end-expiratory pressure during acute respiratory distress syndrome. Crit Care Med. 2013;41:1692–701. doi: 10.1097/CCM.0b013e31828a2323. [DOI] [PubMed] [Google Scholar]
  • 78.Monnet X, Teboul JL. Assessment of volume responsiveness during mechanical ventilation: recent advances. Crit Care. 2013;17:217. doi: 10.1186/cc12526. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 79.Guinot P-G, Godart J, de Broca B, Bernard E, Lorne E, Dupont H. End-expiratory occlusion manoeuvre does not accurately predict fluid responsiveness in the operating theatre. Br J Anaesth. 2014;112:1050–4. doi: 10.1093/bja/aet582. [DOI] [PubMed] [Google Scholar]
  • 80.Geerts BF, Aarts LPHJ, Groeneveld AB, Jansen JRC. Predicting cardiac output responses to passive leg raising by a PEEP-induced increase in central venous pressure, in cardiac surgery patients. Br J Anaesth. 2011;107:150–6. doi: 10.1093/bja/aer125. [DOI] [PubMed] [Google Scholar]
  • 81.Wilkman E, Kuitunen A, Pettilä V, Varpula M. Fluid responsiveness predicted by elevation of PEEP in patients with septic shock. Acta Anaesthesiol Scand. 2014;58:27–35. doi: 10.1111/aas.12229. [DOI] [PubMed] [Google Scholar]
  • 82.Geerts BF, Maas J, de Wilde RBP, Aarts LPHJ, Jansen JRC. Arm occlusion pressure is a useful predictor of an increase in cardiac output after fluid loading following cardiac surgery. Eur J Anaesthesiol. 2011;28:802–6. doi: 10.1097/EJA.0b013e32834a67d2. [DOI] [PubMed] [Google Scholar]
  • 83.Muller L, Toumi M, Bousquet P-J, Riu-Poulenc B, Louart G, Candela D, et al. An increase in aortic blood flow after an infusion of 100 ml colloid over 1 minute can predict fluid responsiveness: the mini-fluid challenge study. Anesthesiology. 2011;115:541–7. doi: 10.1097/ALN.0b013e318229a500. [DOI] [PubMed] [Google Scholar]
  • 84.Wu Y, Zhou S, Zhou Z, Liu B. A 10 second fluid challenge guided by transthoracic echocardiography can predict fluid responsiveness. Crit Care. 2014;18:R108. doi: 10.1186/cc13891. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 85.Nouira S, Elatrous S, Dimassi S, Besbes L, Boukef R, Mohamed B, et al. Effects of norepinephrine on static and dynamic preload indicators in experimental hemorrhagic shock. Crit Care Med. 2005;33:2339–43. doi: 10.1097/01.CCM.0000182801.48137.13. [DOI] [PubMed] [Google Scholar]
  • 86.Giraud R, Siegenthaler N, Arroyo D, Bendjelid K. Impact of epinephrine and norepinephrine on two dynamic indices in a porcine hemorrhagic shock model. J Trauma Acute Care Surg. 2014;77:564–9. doi: 10.1097/TA.0000000000000409. [DOI] [PubMed] [Google Scholar]
  • 87.Suehiro K, Tanaka K, Mikawa M, Uchihara Y, Matsuyama T, Matsuura T, et al. Improved performance of the fourth-generation FloTrac/Vigileo System for tracking cardiac output changes. J Cardiothorac Vasc Anesth. 2015;29:656–62. doi: 10.1053/j.jvca.2014.07.022. [DOI] [PubMed] [Google Scholar]
  • 88.Monnet X, Jabot J, Maizel J, Richard C, Teboul J-L. Norepinephrine increases cardiac preload and reduces preload dependency assessed by passive leg raising in septic shock patients. Crit Care Med. 2011;39:689–94. doi: 10.1097/CCM.0b013e318206d2a3. [DOI] [PubMed] [Google Scholar]

Articles from Journal of Intensive Care are provided here courtesy of BMC

RESOURCES