Abstract
We report a stability below 7 × 10−17 of two independent optical lattice clocks operating with bosonic 88Sr isotope. The value (429 228 066 418 008.3(1.9)syst (0.9)stat Hz) of the absolute frequency of the 1S0 – 3P0 transition was measured with an optical frequency comb referenced to the local representation of the UTC by the 330 km-long stabilized fibre optical link. The result was verified by series of measurements on two independent optical lattice clocks and agrees with recommendation of Bureau International des Poids et Mesures.
Ultracold neutral atoms in an optical lattice1 are seen as an alternative to single-ions2 for development of optical frequency standards. All best present realizations of the strontium optical clocks are made with fermionic strontium isotope 87Sr3,4,5,6,7, since the bosonic isotopes are expected to have larger collisional effects on the clock transition. Additionally, the bosonic isotopes require at least one extra field to induce the clock transition, which implies careful control of this field and its respective field shift. On the other hand, the bosonic lattice clocks have some advantages over their fermionic counterpart: no first order Zeeman shift, no vector or tensor lattice Stark shifts and much higher isotopic abundance. Lack of hyperfine structures in both 1S0 and 3P0 states and higher abundance reduce the time required for one lock cycle. Furthermore, the set-up of cooling and trapping the bosonic isotope is simpler, which is important for transportable systems.
The experimental difficulties in limiting and characterising the collisional shift in bosons are the reason why there are only two reported measurements of the 1S0 − 3P0 transition in 88Sr so far8,9. To calculate the recommended frequency values for the practical realizations of the metre (MeP) and secondary representations of the second (SRS), the BIPM takes into account the weighted average of independently obtained frequencies. A limited pool of available measurements forced the BIMP to set practical relative uncertainties above the level when the 1S0 − 3P0 transition in 88Sr is used as MeP and restrain in recommending this transition as SRS10.
There are two known ways to limit the effects of the collisions: the first, the measurements in the optical lattice trap with low atomic density and high confinement to suppress tunnelling effects11; the second, the use of higher dimensional optical lattice trap9. In our system the low value of collisional shift is ensured by a large waist of the lattice and trapping only a few atoms per lattice site in a trap. We report a system of two independent bosonic strontium optical lattice standards with 88Sr probed with a single shared ultranarrow laser. The absolute frequency of the clock transition is measured by the use of a frequency-doubled Er:fibre polarization-mode-locked optical frequency comb referenced to the UTC(AOS) and UTC(PL)12,13 via the 330 km-long stabilized fibre optic link of the OPTIME network14,15.
Methods
Optical Lattice Standards
The experimental set-up of our system has been described in detail in ref. 16, so only its most essential elements are presented below.
A simplified scheme of the system of two optical lattice clocks is depicted in Fig. 1. Two optical frequency standards (Sr1 and Sr2) are based on the 1S0 − 3P0 transition in neutral 88Sr atoms. Two clouds of cold atoms in Sr1 and Sr2, trapped in the vertical optical lattices, are independently probed by an ultrastable laser with spectral width below 1 Hz. The laser beam is split into two optical paths. The frequencies of both beams are independently digitally locked to the narrow atomic resonances in each standard by feedback to the acousto-optic frequency shifters.
The short-time frequency reference of the optical standards, i.e. the ultrastable laser, is an Extended Cavity Diode Laser (ECDL) locked to the TEM00 mode of the high-Q cavity. The light from the ultrastable laser is transferred to the Sr1 and Sr2 standards and to the optical frequency comb through optical fibres. Each fibre has a system of active Doppler cancellation of the fibre-link noises to assure the transfer of stable optical frequencies17.
In both Sr1 and Sr2 systems the Fabry-Perot diode lasers are injection-locked to the light from ultrastable laser. The master-slave system filters out any power fluctuations of the injection laser. The beam is passing the acousto-optic modulator (AOM) of the digital lock and is injected to the optical lattice such that it is exactly superimposed with the lattice. The beam waist is much bigger than the size of the sample of atoms.
Stabilized fibre optic link and UTC(AOS)
The frequencies of the clock transitions can be compared by the use of an optical frequency comb with the UTC(AOS) and UTC(PL)12,13 via the OPTIME network14.
The 330 km-long time and frequency dissemination line between the Space Research Centre at Borowiec Astrogeodynamic Observatory (AOS) and KL FAMO in Toruń is electronically stabilized with the ELSTAB technology18. The underlying idea of the ELSTAB solution is to implement the compensation of the fibre delay fluctuations in the electronic domain, by using a pair of precisely matched variable delay lines. The delay lines are both placed in the forward and backward paths of the delay-locked-loop (DLL) structure (see Fig. 2, left panel).
The local module is installed at the AOS in Borowiec and the remote module is installed at the KL FAMO in Toruń. Additionally, the line contains seven specialized optical bidirectional amplifiers based on erbium-doped fibres (see Fig. 2, right panel). Thanks to bidirectional operation over the same optical path for the forward and backward directions, the propagation delay is constant for both directions. Consequently, the possible phase fluctuations compensate and the insertion of the amplifier does not destroy the symmetry of the optical path.
To estimate the quality of the link, the pre-installation tests with a 300 km-long fiber on spools and bidirectional optical amplifiers were performed. The stability of the remote 10 MHz signal was measured with respect to the local input, using the A7-MX Signal Stability Analyser. The overlapping Allan deviation is equal to for 1 s integration period, and drops down to within 1 h (Fig. 3).
The local representation of the Coordinated Universal Time (see e.g.19) at AOS in Borowiec, UTC(AOS), is realized directly in the form of a 1PPS (one-pulse-per-second) by a system of an active H-maser (CH1-75A) and an offset generator (Symmetricom Auxiliary Output Generator - AOG). The active H-maser provides good stability over measurement times of up to a few days, with an Allan deviation of at an averaging time of s and decreasing as up to the averaging time of s. The AOG compensates the linear frequency drift of the maser on a daily basis and adds corrections in respect to the UTC, extrapolated from differences UTC- UTC(AOS) and UTCr-UTC(AOS) published monthly and weekly, respectively, in Circular-T20. The details of the frequency chain at the AOS are presented in Fig. 4.
Results
Statistical stability of the system
The difference between the corrections of the digital locks in the Sr1 and Sr2 standards yields the momentary frequency difference between the two clocks. The measured frequency stability in fractional units represented by the Allan standard deviation is presented in Fig. 5 with two standards operating synchronously and asynchronously (red and green lines, respectively). The short-time stability of the standards, up to 100 s of averaging, is limited by the quality of the ultrastable laser. The synchronous operation is mostly free from ultrastable laser fluctuations, except of small residual caused by independent setting of digital locks in the two standards. The measured stability of the synchronously operated clocks, with a clock cycle time of 1.32 s and interrogation time of 40 ms, reached after 10000 s of averaging. The two fundamental limitations of the optical clock stability, i.e. the quantum projection noise (QPN) limit21 for N = 32000 atoms of an individual clock and the Dick effect limit22,23, derived from the power spectral density of the ultrastable clock laser and the clock cycle time, are also depicted in Fig. 5.
The stability of the Sr1 was also compared with the stability of the UTC(AOS) maintained by the hydrogen maser in AOS in Borowiec. The comparison was made over the dedicated 330 km-long stabilized fibre optic link (blue line in Fig. 5). This measured frequency stability provides information about the overall statistical uncertainty of the reference frequency of the hydrogen maser, the stability of the fibre link, and of optical frequency comb. For example, the plateau at around 2000 s corresponds to the ±1 °C fluctuations of temperature in the room where part of the frequency chain at the AOS in Borowiec (micro-stepper and frequency distribution amplifiers) is placed.
Accuracy budget
We have evaluated the main contributions to the frequency shifts in both Sr1 and Sr2 standards. The accuracy budgets are compared in Table 1 for typical experimental conditions: applied B-fields inducing clock transition equal to 2.725 and 2.383 mT, clock laser intensities equal to 207 and 488 mW/cm2 and resultant Rabi frequencies24 equal to 7.4 and 9.7 Hz for Sr1 and Sr2, respectively. Most of the systematic contributions presented there were evaluated by making a series of several simultaneous (interlaced) locks to the atomic line with different values of particular physical parameter in one of the standard, with the other standard serving as a stable reference. Examples of such evaluations are presented in Fig. 6. The notable exceptions were the blackbody radiation (BBR) shift, gravitational red shift and post-processed corrections between UTC(AOS), UTC and TT (the SI second on the geoid).
Table 1. Accuracy budget for typical experimental conditions used in the measurement of the absolute frequency.
Effects | Shift(Uncert.) |
|
---|---|---|
Sr1 | Sr2 | |
Quadratic Zeeman | −151.9(1.7) | −115.42(2.7) |
Probe light | −3.82(0.35) | −9.02(0.37) |
Lattice light | −0.34(0.47) | −1.55(0.48) |
Collisions | 0.35(0.52) | 0.33(0.46) |
Blackbody radiation | −2.210(0.075) | −2.405(0.075) |
Grav. red shift | 2.34(0.10) | 2.34(0.10) |
UTC(AOS) – UTC | −0.40(0.43) | −0.40(0.43) |
UTC – TT | 0.10(0.11) | 0.10(0.11) |
DDS & electronics | 0.00(0.16) | 0.00(0.12) |
Total: | −155.9(1.9) | −126.0(2.8) |
All numbers are in hertz.
The frequency stability (within 1 MHz) of the lattice 813 nm light was assured by narrowing and locking the lattice laser (pre-tuned to the magic wavelength 368 554.58(28) GHz25 with accuracy of 200 MHz by a HighFinesse WS6/200 wavemeter) to the ultrastable 689 nm laser by a Fabry-Perot transfer cavity. The length of the transfer cavity, i.e. wavelength of the cavity modes, was controlled by a piezoelectric transducer and temperature of the cavity spacer. The lattice light shift and its uncertainty are evaluated by making a series of several interlaced locks corresponding to different lattice depths. Different waists of the lattices in Sr1 and Sr2 (152 and 108 μm, respectively) and different depths of the lattices result in different values of measured residual light shift in Sr1 and Sr2.
The shift induced by the BBR can be described as a static shift with a small dynamic correction26. The static contribution is proportional to the differential static polarisability of the two clock states27,28 and the mean square value of the electric field at temperature T. The dynamic correction is calculated similarly as in ref. 27. Two transitions to the states 3P1 and 1P1 contribute to the dynamic shift of the 1S0 ground state and four transitions to the states 3D1, 3S1, 3D1 and 3D1 contribute to the dynamic shift of the 3P0 excited state (see ref. 28,29). The relevant parameters of the transitions are taken from ref. 28,30.
The temperature of crucial points of the vacuum system is monitored during the experiment cycle by calibrated thermistors. The acquired data and an accurate model of the vacuum systems and theirs surroundings are used to simulate the temperature distribution of the system (see Fig. 7). In the simulation (based on finite-element method), the atoms are represented by a small vapour ball inside the vacuum chamber. The temperature probed by this ball is used to calculate the BBR experienced by the atoms. The uncertainty of the shift is evaluated from calculations of the BBR for the maximum and minimum temperatures measured in the experiment.
The UTC(AOS) signal in AOS in Borowiec is corrected with respect to the Earth’s Geoid, therefore the measurements at KL FAMO also have to be corrected with respect to the Geoid with the gravitational red shift. The local height over the Geoid, 50(2) m, and the gravimetrically measured local value of the gravitational acceleration, 9.8127208(26) m/s2, were used for this correction.
The uncertainty of the realization of the frequency of the UTC(AOS), i.e. the difference UTC - UTC(AOS), is estimated by comparing the UTC(AOS) and UTC(PTB) by the Two Way Satellite Frequency and Time Transfer (TWSTFT) and by the proprietary GNSS time transfer system (TTS-4). The values of UTC(AOS) - UTC and UTC - TT as well as uncertainties of UTC(AOS)-UTC(PTB), UTC(AOS)-UTC and UTC - TT are reported in the Circular-T20,31.
The last evaluated uncertainty represents the finite resolution of the direct digital synthesizers (DDSs) driving the AOMs in the frequency chain of the clock lasers.
The described procedure yielded the absolute frequency of the 1S0 − 3P0 clock transition in bosonic 88Sr equal to 429 228 066 418 008.3(1.9)syst(0.9)stat Hz for Sr1 and 429 228 066 418 007.3(2.8)syst(0.9)stat Hz for Sr2. Figure 8 documents the measurement record of both Sr1 and Sr2 standards, binned at 100 s and histograms of the frequency measurements, plotted with an offset frequency νBIPM = 429 228 066 418 012 Hz, i.e the BIPM recommended value10.
Discussion
In Fig. 9 we present comparison of the 88Sr 1S0 − 3P0 transition frequency with the previously known values. The only direct measurement with 88Sr we found in the literature has the uncertainty ten times bigger than the values reported in this paper8. The most precise value of the transition frequency was evaluated based on the measurement of the isotope shift 88Sr-87Sr in ref. 9 and from the frequency of the clock transition in 87Sr4,5,6. Dashed horizontal band in Fig. 9 represents the value recommended by the BIPM10. We believe that better control of the magnetic field would enable measurement of the 88Sr 1S0 − 3P0 transition frequency with accuracy at least order of magnitude better and recommendation of this transition as SRS.
Conclusion
We have performed a series of measurements of the absolute frequency of the 1S0 − 3P0 transition in neutral 88Sr. The measurements has been made in two independent optical lattice clocks with an optical frequency comb referenced to the UTC(AOS) by a long distance stabilized fibre optic link. Our results have comparable accuracy to those indirectly derived in ref. 9 and one order of magnitude better accuracy than value measured directly and reported in ref. 8. Presented results agree with the recommendation of Bureau International des Poids et Mesures and should improve the accuracy of future recommendation. In conclusion, 1S0 − 3P0 transition in the bosonic strontium seems to be a good candidate for practical representation of the second with stability of the order of 10−17, particularly for transportable systems.
Additional Information
How to cite this article: Morzyński, P. et al. Absolute measurement of the 1S0 − 3P0 clock transition in neutral 88Sr over the 330 km-long stabilized fibre optic link. Sci. Rep. 5, 17495; doi: 10.1038/srep17495 (2015).
Acknowledgments
This work has been performed in the National Laboratory FAMO in Toruń and supported by the subsidy of the Ministry of Science and Higher Education. Individual contributors were partially supported by the Polish National Science Centre Projects No. 2012/07/B/ST2/00235, DEC-2013/11/D/ST2/02663, DEC-2012/05/D/ST2/01914 and 2012/07/B/ST2/00251 and by the Foundation for Polish Science TEAM Project co-financed by the EU within the European Regional Development Fund. The fiber optic link development and installation was supported by the Polish National Centre for Research and Development under the decision PBS1/A3/13/2012.
Footnotes
Author Contributions M.Z., P.M. and M.B.: developed the concept and designed experiments, J.Z., C.R., W.G. and R.C.: conceived the optical clocks experiment, P.M., M.B. and M.G.: performed experiments, M.Z., P.M., M.B. and R.C.: analysed data, M.B. and D.B.B.: simulated the BBR shift, M.B., P.M., M.Z., D.L., A.C., P.M., W.G., J.Z., C.R. and R.C.: contributed in construction of the optical clocks apparatus, P.K., Ł.Ś. and M.L.: maintained the fibre link KL FAMO- AOS, J.N. and P.D.: realised and provided frequency referenced to UTC, M.Z. and W.G.: prepared the manuscript, W.G., P.M. and R.C.: technical support and conceptual advice.
References
- Ido T. & Katori H.. Recoil-Free Spectroscopy of Neutral Sr Atoms in the Lamb-Dicke Regime Phys. Rev. Lett. 91, 053001–4 (2003). [DOI] [PubMed] [Google Scholar]
- Rosenband T. et al. Frequency Ratio of Al+ and Hg+ Single-Ion Optical Clocks, Metrology at the 17th Decimal Place. Science 319, 1808 (2008). [DOI] [PubMed] [Google Scholar]
- Bloom B. J. et al. An optical lattice clock with accuracy and stability at the 10−18 level. Nature 506, 71–75 (2014). [DOI] [PubMed] [Google Scholar]
- Le Targat R. et al. Experimental realization of an optical second with strontium lattice clocks. Nature Commun. 4, 2109 (2013). [DOI] [PubMed] [Google Scholar]
- Hinkley N. et al. An atomic clock with 10−18 instability Science 341, 1215–8 (2013). [DOI] [PubMed] [Google Scholar]
- Falke S. et al. A strontium lattice clock with 3×10−17 inaccuracy and its frequency. New J. Phys. 16, 073023 (2014). [Google Scholar]
- Ushijima I., Takamoto M., Das M., Ohkubo T. & Katori H.. Cryogenic optical lattice clocks. Nature Photon. 9, 185–189 (2015). [Google Scholar]
- Baillard X. et al. Accuracy Evaluation of an Optical Lattice Clock with Bosonic Atoms. Opt. Lett. 32, 1812–1814 (2007). [DOI] [PubMed] [Google Scholar]
- Akatsuka T., Takamoto M. & Katori H.. Optical lattice clocks with non-interacting bosons and fermions. Nature Physics 4, 954–959 (2008). [Google Scholar]
- Bureau International des Poids et Mesures (BIPM). Recommended Values Of Standard Frequencies For Applications Including The Practical Realization Of The Metre And Secondary Representations Of The Definition Of The Second, Strontium 88 Atom (f ≈ 429 THz) (BIPM, Sèvres, France, 2009). [Google Scholar]
- Lisdat C., Vellore Winfred J. S. R., Middelmann T., Riehle F. & Sterr U.. Collisional losses, decoherence, and frequency shifts in optical lattice clocks with bosons. Physic. Rev. Lett. 103, 090801 (2009). [DOI] [PubMed] [Google Scholar]
- Azoubib J., Nawrocki J. & Lewandowski W.. Independent atomic timescale in Poland - organization and results Metrologia 40, S245 (2003). [Google Scholar]
- Jiang Z., Czubla A., Nawrocki J., Lewandowski W. & Arias E. F.. Comparing a GPS time link calibration with an optical fibre self-calibration with 200 ps accuracy. Metrologia 52, 384 (2015). [Google Scholar]
- Śliwczyński Ł., Krehlik P., Czubla A., Buczek & Lipiński M.. Dissemination of time and RF frequency via a stabilized fibre optic link over a distance of 420 km. Metrologia 50. 133–145 (2013). [Google Scholar]
- Krehlik P., Śliwczyński Ł., Buczek Ł., Kołodziej J. & Lipiński M.. Ultrastable long-distance fibre-optic time transfer: active compensation over a wide range of delays. Metrologia 52, 82 (2015). [Google Scholar]
- Bober M. et al. Strontium optical lattice clocks for practical realization of the metre and secondary representation of the second. Meas. Sci. Technol. 26, 075201 (2015). [Google Scholar]
- Ma L. S., Jungner P., Ye J. & Hall J. H.. Delivering the same optical frequency at two places: introduced by an optical fibre or other time-varying path accurate cancellation of phase noise Opt. Lett. 19, 1777 (1994). [DOI] [PubMed] [Google Scholar]
- Śliwczyński Ł., Krehlik P., Buczek Ł. & Lipiński M.. Active propagation delay stabilization for fiber optic frequency distribution using controlled electronic delay lines. IEEE Trans. Instrum. Meas. 60, 1480 (2011). [Google Scholar]
- Whibberley P. B., Davis J. A. & Shemar S. L.. Local representations of UTC in national laboratories. Metrologia 48, S154 (2011). [Google Scholar]
- BIPM Circular T, Available at http://www.bipm.org/jsp/en/TimeFtp.jsp?TypePub=publication.
- Santarelli G. et al. Quantum Projection Noise in an Atomic Fountain: A High Stability Cesium Frequency Standard. Phys. Rev. Lett. 82, 4619 (1999). [Google Scholar]
- Dick G.. Local oscillator induced instabilities in trapped ion frequency standards Proc. Precise Time and Time Interval, Redendo Beach, CA 133 (1987). [Google Scholar]
- Santarelli G. et al. Frequency stability degradation of an oscillator slaved to a periodically interrogated atomic resonator. IEEE Trans. Ultrason. Ferroelectr. Freq. Control 45, 887 (1998). [DOI] [PubMed] [Google Scholar]
- Taichenachev A. V. et al. Magnetic field-induced spectroscopy of forbidden optical transitions with application to lattice-based optical atomic clocks. Phys. Rev. Lett. 96, 083001 (2006). [DOI] [PubMed] [Google Scholar]
- Akatsuka T., Takamoto M. & Katori H.. Three-dimensional optical lattice clock with bosonic 88Sr atoms. Phys. Rev. A 81, 023402 (2010). [Google Scholar]
- Middelmann T. et al. Tackling the blackbody shift in a strontium optical lattice clock. IEEE Trans. Instrum. Meas. 60, 2550 (2011). [Google Scholar]
- Middelmann T., Falke S., Lisdat C. & Sterr U.. High Accuracy Correction of Blackbody Radiation Shift in an Optical Lattice Clock. Phys. Rev. Lett. 109, 263004 (2012). [DOI] [PubMed] [Google Scholar]
- Safronova M. S., Porsev S. G., Safronova U. I., Kozlov M. G. & Clark C. W.. Blackbody-radiation shift in the Sr optical atomic clock. Phys. Rev. A 87, 012509 (2013). [Google Scholar]
- Porsev S. G. & Derevianko A.. Multipolar theory of blackbody radiation shift of atomic energy levels and its implications for optical lattice clocks. Phys. Rev. A 74, 020502(R) (2006). [Google Scholar]
- Sansonetti J. E. & Nave G.. Wavelengths, Transition Probabilities, and Energy Levels for the Spectrum of Neutral Strontium (Sr I). J. Phys. Chem. Ref. Data 39, 033103 (2010). [Google Scholar]
- Lewandowski W., Matsakis D., Panfilo G. & Tavella P.. The evaluation of uncertainties in [UTC - UTC(k)]. Metrologia 43, 278 (2006). [Google Scholar]