Abstract
Henderson, B. J., Mitha, A. S., le Roux, B. T., and Gotsman, M. S. (1973).Thorax, 28, 488-491. Haemolysis related to mitral valve replacement with the Beall valve prothesis. Experience of valve replacement with the Beall compressed Teflon disc valve in 59 patients confirms that the incidence of clinically significant late red cell destruction is high. An apparently previously unrecorded high incidence of early haemolysis, so severe in one patient as to be directly the cause of death, is reported. In 29 patients there was massive haemolysis in early convalescence, not recognized in urine from some hours after the end of bypass and never encountered with other designs of prosthetic valve or homograft valve.
Full text
PDF



Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Beall A. C., Jr, Bricker D. L., Messmer B. J. Results of mitral valve replacement with dacron velour-covered teflon-disc prosthesis. Ann Thorac Surg. 1970 Mar;9(3):195–202. doi: 10.1016/s0003-4975(10)65489-6. [DOI] [PubMed] [Google Scholar]
- Berroya R. B., Escano F. B., Jr Mitral disc-valve variance. Thorax. 1972 Jan;27(1):87–89. doi: 10.1136/thx.27.1.87. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Crexells C., Aerichide N., Bonny Y., Lepage G., Campeau L. Factors influencing hemolysis in valve prosthesis. Am Heart J. 1972 Aug;84(2):161–170. doi: 10.1016/0002-8703(72)90330-4. [DOI] [PubMed] [Google Scholar]
- Javier R. P., Hildner F. J., Berry W., Greenberg J. J., Samet P. Systemic embolism and the Beall mitral valve prosthesis. Ann Thorac Surg. 1970 Jul;10(1):20–26. doi: 10.1016/s0003-4975(10)65560-9. [DOI] [PubMed] [Google Scholar]
- Magovern G. J., Begg F. J., Kent E. M., Cushing W. B., Gerber M. L., Fisher D. L. The experimental and clinical results of a modified cage disc mitral prosthesis. J Thorac Cardiovasc Surg. 1970 Jan;59(1):109–116. [PubMed] [Google Scholar]
- Vogel J. H., Paton B. C., Overy H. R., Pappas G., Davies D. H., Blount S. G., Jr Advantages of the Beall valve prosthesis. Chest. 1971 Mar;59(3):249–253. doi: 10.1378/chest.59.3.249. [DOI] [PubMed] [Google Scholar]
- Williams J. C., Jr, Vernon C. R., Daicoff G. R., Bartley T. D., Wheat M. W., Jr, Ramsey H. W. Hemolysis following mitral valve replacement with the Beall valve prosthesis. J Thorac Cardiovasc Surg. 1971 Mar;61(3):393–396. [PubMed] [Google Scholar]
- eall A. C., Jr, Bloodwell R. D., Liotta D., Cooley D. A., De Bakey M. E. Clinical experience with a dacron velour-covered teflon-disc mitral-valve prosthesis. Ann Thorac Surg. 1968 May;5(5):402–410. doi: 10.1016/s0003-4975(10)66371-0. [DOI] [PubMed] [Google Scholar]
