Abstract
The use of a single pair of magnetometer coils placed centrally on the trunk to record tidal volumes and breath times has been evaluated in five normal subjects in five positions. Breath times were accurate in all positions tested but tidal volumes were only reliable with the subjects lying and the backrest raised to 45° or in the supine position only for volumes up to 1000 ml. Using this system, recordings have been made in seven patients with barbiturate overdose, five with salicylate overdose, and five undergoing anaesthesia with thiopentone. The single pair of coils was satisfactory for measuring changes in the pattern of breathing in these patients. In barbiturate overdose in five patients there was initially an increase in respiratory frequency with a decrease in tidal volume. As these patients recovered the tidal volume increased and the respiratory rate slowed. In two patients who had a raised PaCO2 there was initially reduction of both tidal volume and respiratory rate, both increasing as the patients recovered. Monitoring respiratory rate appears to be a useful guide in barbiturate overdose; a slowing of the rate without recovery of consciousness warrants further investigation to assess the need for ventilatory support. The single pair of coils were also satisfactory for measuring the increased tidal volume in salicylate overdose. As after other respiratory stimuli in man, increased ventilation occurred predominantly through changes in tidal volume and expiratory time while inspiratory time changed very little.
Full text
PDF




Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Ashutosh K., Gilbert R., Auchincloss J. H., Erlebacher J., Peppi D. Impedance pneumograph and magnetometer methods for monitoring tidal volume. J Appl Physiol. 1974 Dec;37(6):964–966. doi: 10.1152/jappl.1974.37.6.964. [DOI] [PubMed] [Google Scholar]
- Clark F. J., von Euler C. On the regulation of depth and rate of breathing. J Physiol. 1972 Apr;222(2):267–295. doi: 10.1113/jphysiol.1972.sp009797. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Gautier H., Gaudy J. H. Changes in ventilatory pattern induced by intravenous anesthetic agents in human subjects. J Appl Physiol Respir Environ Exerc Physiol. 1978 Aug;45(2):171–176. doi: 10.1152/jappl.1978.45.2.171. [DOI] [PubMed] [Google Scholar]
- Gilbert R., Auchincloss J. H., Jr, Brodsky J., Boden W. Changes in tidal volume, frequency, and ventilation induced by their measurement. J Appl Physiol. 1972 Aug;33(2):252–254. doi: 10.1152/jappl.1972.33.2.252. [DOI] [PubMed] [Google Scholar]
- Gillam P. M. Patterns of respiration in human beings at rest and during sleep. Bull Physiopathol Respir (Nancy) 1972 Sep-Oct;8(5):1059–1070. [PubMed] [Google Scholar]
- Higenbottam T., Allen D., Loh L., Clark T. J. Abdominal wall movement in normals and patients with hemidiaphragmatic and bilateral diaphragmatic palsy. Thorax. 1977 Oct;32(5):589–95-09ENG. doi: 10.1136/thx.32.5.589. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Konno K., Mead J. Measurement of the separate volume changes of rib cage and abdomen during breathing. J Appl Physiol. 1967 Mar;22(3):407–422. doi: 10.1152/jappl.1967.22.3.407. [DOI] [PubMed] [Google Scholar]
- Mead J., Peterson N., Grimby G., Mead J. Pulmonary ventilation measured from body surface movements. Science. 1967 Jun 9;156(3780):1383–1384. doi: 10.1126/science.156.3780.1383. [DOI] [PubMed] [Google Scholar]
- Peyrot A. H., Hertel G. A., Siebens A. A. Pulmonary ventilation measured by a single linear displacement transducer. Med Biol Eng. 1969 Mar;7(2):233–234. doi: 10.1007/BF02474180. [DOI] [PubMed] [Google Scholar]
- Stagg D., Goldman M., Davis J. N. Computer-aided measurement of breath volume and time components using magnetometers. J Appl Physiol Respir Environ Exerc Physiol. 1978 Apr;44(4):623–633. doi: 10.1152/jappl.1978.44.4.623. [DOI] [PubMed] [Google Scholar]