Abstract
The incidence and the outcome of systemic air embolism in 340 consecutive patients who underwent cardiac surgery under cardiopulmonary bypass in this unit for congenital defects of the cardiac septa and diseases involving the aortic and mitral valves have been studied. This was thought to have occurred in 40 patients, of whom 10 died. The distribution of air embolism according to the types of operation undertaken was as follows: six of 127 for atrial septal defect; six of 36 for ventricular septal defect; seven of 42 for mitral valve replacement; seven of 47 for aortic valve débridement; and 14 of 55 for aortic valve replacement. The cause was considered to have been systolic ejection of air into the aorta which, following cardiotomy, had been trapped in the pulmonary veins, the left atrium, the ventricular trabeculae, and the aortic root. Since the adoption of a more rigid `debubbling' routine, air embolism has not occurred. The incidence of pulmonary complications occurring in these patients after bypass was studied. Unilateral atelectasis, which occurred in five patients, resulted from retained bronchial secretions in all and was cured by bronchoscopic aspiration in all. The cause of bilateral atelectases, occurring in nine patients and fatal in eight of these, appeared to be related to cardiopulmonary factors and not to air embolism. Acute air injection made into the pulmonary artery of a dog resulted in pulmonary hypertension and a grossly deficient pulmonary circulation, but changes were largely resolved within a week. In view of this, it is considered that pulmonary air embolism may temporarily embarrass the right heart after the repair of a ventricular septal defect in a patient with an elevated pulmonary vascular resistance and diminished pulmonary vascular bed.
Full text
PDF






Images in this article
Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- CALLAGHAN J. C., DESPRES J. P., BENVENUTO R. A study of the causes of 60 deaths following total cardiopulmonary bypass. J Thorac Cardiovasc Surg. 1961 Oct;42:489–496. [PubMed] [Google Scholar]
- CASSIE A. B., RIDDELL A. G., YATES P. O. Hazard of antifoam emboli from a bubble oxygenator. Thorax. 1960 Mar;15:22–29. doi: 10.1136/thx.15.1.22. [DOI] [PMC free article] [PubMed] [Google Scholar]
- CLARKE F. B. MONITORING OF CORONARY ARTERY PERFUSION. J Thorac Cardiovasc Surg. 1965 Jun;49:931–936. [PubMed] [Google Scholar]
- COOLEY D. A., BELMONTE B. A., LATSON J. R., PIERCE J. F. Bubble diffusion oxygenator for cardiopulmonary by-pass. J Thorac Surg. 1958 Jan;35(1):131–134. [PubMed] [Google Scholar]
- EHRENHAFT J. L., CLAMAN M. A. Cerebral complications of open-heart surgery. J Thorac Cardiovasc Surg. 1961 Apr;41:503–508. [PubMed] [Google Scholar]
- FAZIO C., SACCHI U. Experimentally produced red softening of the brain. J Neuropathol Exp Neurol. 1954 Jul;13(3):476–481. doi: 10.1093/jnen/13.3.476. [DOI] [PubMed] [Google Scholar]
- GIBBON J. H., Jr, MILLER B. J., DOBELL A. R., ENGELL H. C., VOIGT G. B. The closure of interventricular septal defects in dogs during open cardiotomy with the maintenance of the cardiorespiratory functions by a pump-oxygenator. J Thorac Surg. 1954 Sep;28(3):235–240. [PubMed] [Google Scholar]
- GILMAN S. CEREBRAL DISORDERS AFTER OPEN-HEART OPERATIONS. N Engl J Med. 1965 Mar 11;272:489–498. doi: 10.1056/NEJM196503112721001. [DOI] [PubMed] [Google Scholar]
- GROVES L. K., EFFLER D. B. A NEEDLE-VENT SAFEGUARD AGAINST SYSTEMIC AIR EMBOLUS IN OPEN-HEART SURGERY. J Thorac Cardiovasc Surg. 1964 Mar;47:349–355. [PubMed] [Google Scholar]
- KIRKLIN J. W., PATRICK R. T., THEYE R. A. Theory and practice in the use of a pump-oxygenator for open intracardiac surgery. Thorax. 1957 Jun;12(2):93–98. doi: 10.1136/thx.12.2.93. [DOI] [PMC free article] [PubMed] [Google Scholar]
- MALONEY J. V., Jr, LONGMIRE W. P., Jr, SCHMUTZER K. J., MARABLE S. A., RASCHKE E., WATANABE Y., LOBPREIS E. L., ARZOUMAN J. E. An experimental and clinical comparison of the bubble dispersion and stationary screen pump oxygenators. Surg Gynecol Obstet. 1958 Nov;107(5):577–587. [PubMed] [Google Scholar]
- MARTIN W. B., ESSEX H. E. Experimental production and closure of atrial septal defects, with observations of physiologic effects. Surgery. 1951 Aug;30(2):283–297. [PubMed] [Google Scholar]
- MELROSE D. G., DREYER B., BENTALL H. H., BAKER J. B. Elective cardiac arrest. Lancet. 1955 Jul 2;269(6879):21–22. doi: 10.1016/s0140-6736(55)93381-x. [DOI] [PubMed] [Google Scholar]
- MILLER B. J., GIBBON J. H., Jr, GRECO V. F., COHN C. H., ALLBRITTEN F. F., Jr The use of a vent for the left ventricle as a means of avoiding air embolism to the systemic circulation during open cardiotomy with the maintenance of the cardiorespiratory function of animals by a pump oxygenator. Surg Forum. 1953 Oct;4:29–33. [PubMed] [Google Scholar]
- SWANK R. L., HAIN R. F. The effect of different sized emboli on the vascular system and parenchyma of the brain. J Neuropathol Exp Neurol. 1952 Jul;11(3):280–299. doi: 10.1097/00005072-195207000-00005. [DOI] [PubMed] [Google Scholar]
- WRIGHT E. S., SARKOZY E., DOBELL A. R., MURPHY D. R. Fat globulemia in extracorporeal circulation. Surgery. 1963 Apr;53:500–504. [PubMed] [Google Scholar]