Skip to main content
Thorax logoLink to Thorax
. 1967 Nov;22(6):533–537. doi: 10.1136/thx.22.6.533

Asthma due to aluminium soldering flux

G M Sterling 1
PMCID: PMC471707  PMID: 6076508

Abstract

Two patients have been studied who complained of dyspnoea after the inhalation of fumes from a new soldering flux recently developed for use in jointing aluminium which has been replacing copper as a material for electric cables. A previous survey of respiratory complaints after the use of this particular flux had failed to show any objective change in lung function, and the present cases are the first to be reported. Both subjects have been investigated by means of serial spirometry, peak flow rates, and body plethysmography following inhalation of small amounts of flux fumes; delayed and prolonged bronchoconstriction has been demonstrated. Similar results have been obtained after the inhalation of one of the main constituents of the flux, namely amino-ethyl ethanolamine, which is presumably the active allergic agent. The bronchial response is unusual in being delayed in onset but otherwise resembles pollen-sensitivity asthma rather than the infiltrative process seen in farmer's lung. The type of immune mechanism involved is speculative, but it is possible that some alteration of the amino-ethyl ethanolamine is needed before it can react with reaginic antibody fixed in the bronchial tissues.

Full text

PDF
533

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. DUBOIS A. B., BOTELHO S. Y., BEDELL G. N., MARSHALL R., COMROE J. H., Jr A rapid plethysmographic method for measuring thoracic gas volume: a comparison with a nitrogen washout method for measuring functional residual capacity in normal subjects. J Clin Invest. 1956 Mar;35(3):322–326. doi: 10.1172/JCI103281. [DOI] [PMC free article] [PubMed] [Google Scholar]
  2. DUBOIS A. B., BOTELHO S. Y., COMROE J. H., Jr A new method for measuring airway resistance in man using a body plethysmograph: values in normal subjects and in patients with respiratory disease. J Clin Invest. 1956 Mar;35(3):327–335. doi: 10.1172/JCI103282. [DOI] [PMC free article] [PubMed] [Google Scholar]
  3. Hargreave F. E., Pepys J., Longbottom J. L., Wraith D. G. Bird breeder's (fancier's) lung. Lancet. 1966 Feb 26;1(7435):445–449. doi: 10.1016/s0140-6736(66)91454-1. [DOI] [PubMed] [Google Scholar]
  4. MCCANN J. K. HEALTH HAZARD FROM FLUX USED IN JOINING ALUMINIUM ELECTRICITY CABLES. Ann Occup Hyg. 1964 Sep;7:261–268. doi: 10.1093/annhyg/7.3.261. [DOI] [PubMed] [Google Scholar]
  5. NADEL J. A., COMROE J. H., Jr Acute effects of inhalation of cigarette smoke on airway conductance. J Appl Physiol. 1961 Jul;16:713–716. doi: 10.1152/jappl.1961.16.4.713. [DOI] [PubMed] [Google Scholar]
  6. PEPYS J., JENKINS P. A. PRECIPITIN (F.L.H.) TEST IN FARMER'S LUNG. Thorax. 1965 Jan;20:21–35. doi: 10.1136/thx.20.1.21. [DOI] [PMC free article] [PubMed] [Google Scholar]
  7. WIDDICOMBE J. G., KENT D. C., NADEL J. A. Mechanism of bronchoconstriction during inhalation of dust. J Appl Physiol. 1962 Jul;17:613–616. doi: 10.1152/jappl.1962.17.4.613. [DOI] [PubMed] [Google Scholar]
  8. Woolcock A. J., Read J. Improvement in bronchial asthma not reflected in forced expiratory volume. Lancet. 1965 Dec 25;2(7426):1323–1325. doi: 10.1016/s0140-6736(65)92343-3. [DOI] [PubMed] [Google Scholar]

Articles from Thorax are provided here courtesy of BMJ Publishing Group

RESOURCES