Abstract
Mitral valve replacement using pig aortic valve heterografts has been performed in 27 dogs, siting the grafts in the `atrial position'. Buffered acid formaldehyde sterilization offered the advantages that it is simple and, by de-naturing the proteins of the graft, may minimize `rejection' phenomena. It may offer some self-sterilizing property to the graft within the host post-operatively. The question whether heterograft valves will ultimately calcify remains unanswered. The aortic valve has been shown to function satisfactorily in place of the mitral valve for up to four months, producing normal haemodynamic studies. The `atrial position' of the graft has the advantage that the left ventricular cavity becomes totally available for its pumping activities. The fate of these animals depended upon developing mitral incompetence around the grafts and thrombus, leading to mitral stenosis, rather than to rejection phenomena. The operation described requires accuracy in orientating the graft. Mounting heterografts (with almost the whole of the aortic wall cut away) in a Dacron-covered metal frame pre-operatively provided a valve in a range of sizes which can be inserted in the same manner as any prosthesis in current use. Methods of sterilization and storage and the ultimate fate of heterografts in vivo require further study. Failure such as calcification will probably not develop suddenly. Such a valve could be replaced if necessary. The continued investigation and clinical use of heterografts appears to be justified when viewed against the uncertain outcome of the other methods of valve replacement.
Full text
PDF









Images in this article
Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- BARRATT-BOYES B. G. HOMOGRAFT AORTIC VALVE REPLACEMENT IN AORTIC INCOMPETENCE AND STENOSIS. Thorax. 1964 Mar;19:131–150. doi: 10.1136/thx.19.2.131. [DOI] [PMC free article] [PubMed] [Google Scholar]
- DURAN C. G., GUNNING A. J. A method for placing a total homologous aortic valve in the subcoronary position. Lancet. 1962 Sep 8;2(7254):488–489. doi: 10.1016/s0140-6736(62)90346-x. [DOI] [PubMed] [Google Scholar]
- Hubka M., Siska K., Brozman M., Holec V. Replacement of mitral and tricuspid valves by mitral homograft. J Thorac Cardiovasc Surg. 1966 Feb;51(2):195–204. [PubMed] [Google Scholar]
- Ionescu M. I., Wooler G. H., Smith D. R., Grimshaw V. A. Mitral valve replacement with aortic heterografts in humans. Thorax. 1967 Jul;22(4):305–313. doi: 10.1136/thx.22.4.305. [DOI] [PMC free article] [PubMed] [Google Scholar]
- LOWER R. R., STOFER R. C., SHUMWAY N. E. Total excision of the mitral valve and replacement with the autologous pulmonic valve. J Thorac Cardiovasc Surg. 1961 Nov;42:696–702. [PubMed] [Google Scholar]
- McKenzie M. B., Titus J. L., Rastelli G. C., Pappas G., Ellis F. H., Jr Replacement of the canine mitral valve with semilunar valves. J Thorac Cardiovasc Surg. 1966 Feb;51(2):168–179. [PubMed] [Google Scholar]
- O'Brien M. F., Clarebrough J. K., McDonald I. G., Hale G. S., Bray H. S., Cade J. F. Heterograft aortic valve replacement: initial follow-up studies. Thorax. 1967 Sep;22(5):387–396. doi: 10.1136/thx.22.5.387. [DOI] [PMC free article] [PubMed] [Google Scholar]
- O'Brien M. F. Heterograft aortic valves for human use. Valve bank, techniques of measurement, and implantation. J Thorac Cardiovasc Surg. 1967 Mar;53(3):392–397. [PubMed] [Google Scholar]
- ROSS D. N. Homograft replacement of the aortic valve. Lancet. 1962 Sep 8;2(7254):487–487. doi: 10.1016/s0140-6736(62)90345-8. [DOI] [PubMed] [Google Scholar]
- Suzuki A., Kay E. B. A new technique of mitral valve replacement with a homologous aortic valve. Jpn Circ J. 1966 Sep;30(9):1193–1202. doi: 10.1253/jcj.30.1193. [DOI] [PubMed] [Google Scholar]












