Skip to main content
Thorax logoLink to Thorax
. 1981 Nov;36(11):828–834. doi: 10.1136/thx.36.11.828

Occupational asthma in a factory making flux-cored solder containing colophony.

P S Burge, G Edge, R Hawkins, V White, A J Taylor
PMCID: PMC471823  PMID: 7330804

Abstract

The prevalence of work-related wheeze and breathlessness was measured in factory employees manufacturing flux-cored solder. The flux contained colophony which was heated in the production process, exposing the workers to colophony fumes. Measurement of colophony in the breathing zone defined three grades of exposure with median levels of 1.92 mg/m3 (six subjects), 0.02 mg/m3 (14 subjects), and less than 0.01 mg/m3 (68 subjects). All but two workers in the first two groups, and 90% of a random sample of the last group, were studied. Occupational asthma was present in 21% of the higher two exposure groups and 4% of the lowest exposure group. Mean values of FEV1 and FVC fell with increasing exposure. The prevalence of upper and lower respiratory symptoms was only one-third to a half that found in a previous study of shop floor electronics workers, whose work raised the flux to a higher temperature and produced higher concentrations of colophony fume. Total IgM levels were higher in the solder manufacturers than in unexposed controls, and were higher still in the electronics workers. The solder manufacturers were exposed to colophony fumes at 140 degrees C, below the temperature at which the resin acids decompose, supporting the hypothesis that it is the whole resin acids rather than decomposition products which cause occupational asthma. The threshold limit value should be based on the resin acid content of the fume, and not the aldehyde content as at present. The survey suggests that sensitisation will not be prevented unless exposure is kept well below the present threshold limit value.

Full text

PDF
828

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Burge P. S., Harries M. G., O'Brien I. M., Pepys J. Respiratory disease in workers exposed to solder flux fumes containing colophony (pine resin). Clin Allergy. 1978 Jan;8(1):1–14. doi: 10.1111/j.1365-2222.1978.tb00441.x. [DOI] [PubMed] [Google Scholar]
  2. Burge P. S., Harries M. G., O'Brien I., Pepys J. Bronchial provocation studies in workers exposed to the fumes of electronic soldering fluxes. Clin Allergy. 1980 Mar;10(2):137–149. doi: 10.1111/j.1365-2222.1980.tb02091.x. [DOI] [PubMed] [Google Scholar]
  3. Burge P. S., Perks W. H., O'Brien I. M., Burge A., Hawkins R., Brown D., Green M. Occupational asthma in an electronics factory: a case control study to evaluate aetiological factors. Thorax. 1979 Jun;34(3):300–307. doi: 10.1136/thx.34.3.300. [DOI] [PMC free article] [PubMed] [Google Scholar]
  4. Burge P. S., Perks W., O'Brien I. M., Hawkins R., Green M. Occupational asthma in an electronics factory. Thorax. 1979 Feb;34(1):13–18. doi: 10.1136/thx.34.1.13. [DOI] [PMC free article] [PubMed] [Google Scholar]
  5. Fawcett I. W., Taylor A. J., Pepys J. Asthma due to inhaled chemical agents--fumes from 'Multicore' soldering flux and colophony resin. Clin Allergy. 1976 Nov;6(6):577–585. doi: 10.1111/j.1365-2222.1976.tb01944.x. [DOI] [PubMed] [Google Scholar]
  6. McKerrow C. B., Rossiter C. E. An annual cycle in the ventilatory capacity of men with pneumoconiosis and of normal subjects. Thorax. 1968 Jul;23(4):340–349. doi: 10.1136/thx.23.4.340. [DOI] [PMC free article] [PubMed] [Google Scholar]
  7. Perks W. H., Burge P. S., Rehahn M., Green M. Work-related respiratory disease in employees leaving an electronics factory. Thorax. 1979 Feb;34(1):19–22. doi: 10.1136/thx.34.1.19. [DOI] [PMC free article] [PubMed] [Google Scholar]

Articles from Thorax are provided here courtesy of BMJ Publishing Group

RESOURCES