Oxygen toxicity during artificial ventilation

R A L Brewis 1
PMCID: PMC472069  PMID: 4900444

Abstract

Repeated pulmonary collapse and changes suggestive of a severe alveolar-capillary diffusion defect were observed over a period of 20 days in a patient who was receiving artificial ventilation because of status epilepticus. Profound cyanosis followed attempts to discontinue assisted ventilation. The Bird Mark 8 respirator employed was found to be delivering approximately 90% oxygen on the air-mix setting and pulmonary oxygen toxicity was suspected. Radiological improvement and progressive resolution of the alveolar-capillary block followed gradual reduction of the inspired concentration over nine days. The management and prevention of this complication are discussed. The inspired oxygen concentration should be routinely monitored in patients receiving intermittent positive pressure ventilation, and the concentration should not be higher than that required to maintain adequate oxygenation. The Bird Mark 8 respirator has an inherent tendency to develop high oxygen concentrations on the air-mix setting, and the machine should therefore be driven from a compressed air source unless high concentrations of oxygen are essential.

Full text

PDF
656

Images in this article

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Ashbaugh D. G., Bigelow D. B., Petty T. L., Levine B. E. Acute respiratory distress in adults. Lancet. 1967 Aug 12;2(7511):319–323. doi: 10.1016/s0140-6736(67)90168-7. [DOI] [PubMed] [Google Scholar]
  2. BENDIXEN H. H., HEDLEY-WHYTE J., LAVER M. B. IMPAIRED OXYGENATION IN SURGICAL PATIENTS DURING GENERAL ANESTHESIA WITH CONTROLLED VENTILATION. A CONCEPT OF ATELECTASIS. N Engl J Med. 1963 Nov 7;269:991–996. doi: 10.1056/NEJM196311072691901. [DOI] [PubMed] [Google Scholar]
  3. Cederberg A., Hellsten S., Miörner G. Oxygen treatment and hyaline pulmonary membranes in adults. Acta Pathol Microbiol Scand. 1965;64(4):450–458. doi: 10.1111/apm.1965.64.4.450. [DOI] [PubMed] [Google Scholar]
  4. DONALD K. W. Oxygen poisoning in man. Br Med J. 1947 May 17;1(4506):667–passim. [PMC free article] [PubMed] [Google Scholar]
  5. Déry R., Pelletier J., Jacques A., Clavet M., Houde J. Alveolar collapse induced by denitrogenation. Can Anaesth Soc J. 1965 Nov;12(6):531–557. doi: 10.1007/BF03004416. [DOI] [PubMed] [Google Scholar]
  6. FAIRLEY H. B., BRITT B. A. THE ADEQUACY OF THE AIR-MIX CONTROL IN VENTILATORS OPERATED FROM AN OXYGEN SOURCE. Can Med Assoc J. 1964 Jun 20;90:1394–1396. [PMC free article] [PubMed] [Google Scholar]
  7. Green I. D. Choice of method for administration of oxygen. Br Med J. 1967 Sep 2;3(5565):593–596. doi: 10.1136/bmj.3.5565.593. [DOI] [PMC free article] [PubMed] [Google Scholar]
  8. Nash G., Blennerhassett J. B., Pontoppidan H. Pulmonary lesions associated with oxygen therapy and artifical ventilation. N Engl J Med. 1967 Feb 16;276(7):368–374. doi: 10.1056/NEJM196702162760702. [DOI] [PubMed] [Google Scholar]
  9. PRATT P. C. Pulmonary capillary proliferation induced by oxygen inhalation. Am J Pathol. 1958 Nov-Dec;34(6):1033–1049. [PMC free article] [PubMed] [Google Scholar]
  10. Stoddart J. C. Some observations on the function of the Bird Mark 8 ventilator. Br J Anaesth. 1966 Dec;38(12):977–980. doi: 10.1093/bja/38.12.977. [DOI] [PubMed] [Google Scholar]

Articles from Thorax are provided here courtesy of BMJ Publishing Group

RESOURCES