Abstract
In 11 patients with bronchial asthma, lung volumes, FEV1·0, PaO2, and lung diffusing capacity (single breath CO method) were measured in status asthmaticus and after recovery.
Ventilatory capacity improved following therapy. The improvement was associated with a rise in vital capacity and a fall in residual volume, but the total lung capacity might either decrease, increase or remain unchanged.
A decreased value of PaO2 was found in all patients in status asthmaticus. After treatment PaO2 increased in all patients. In two of them PaO2 increased despite the unchanged values of the other parameters of pulmonary function. The improvement of PaO2 after treatment is considered to be the result of adjustment of perfusion to ventilation.
The lung diffusing capacity was below normal values in three patients before treatment. After treatment the diffusing capacity increased in six patients. The diffusion constant, although within the normal range in status asthmaticus, increased after treatment in one and decreased in three other patients. The decreased diffusing capacity in status asthmaticus is the consequence of a reduced effective alveolar volume due to uneven distribution of ventilation. The changes observed in the diffusion constant following corticotherapy are ascribed to a dependence of this constant on the different level of the alveolar volume at which the single breath test is performed.
Full text
PDF





Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- BERGLUND E., BIRATH G., BJURE J., GRIMBY G., KJELLMER I., SANDQVIST L., SODERHOLM B. Spirometric studies in normal subjects. I. Forced expirograms in subjects between 7 and 70 years of age. Acta Med Scand. 1963 Feb;173:185–192. [PubMed] [Google Scholar]
- BLAKEMORE W. S., FORSTER R. E., MORTON J. W., OGILVIE C. M. A standardized breath holding technique for the clinical measurement of the diffusing capacity of the lung for carbon monoxide. J Clin Invest. 1957 Jan;36(1 Pt 1):1–17. doi: 10.1172/JCI103402. [DOI] [PMC free article] [PubMed] [Google Scholar]
- BURROWS B., KASIK J. E., NIDEN A. H., BARCLAY W. R. Clinical usefulness of the single-breath pulmonucy diffusing capacity test. Am Rev Respir Dis. 1961 Dec;84:789–806. doi: 10.1164/arrd.1961.84.6.789. [DOI] [PubMed] [Google Scholar]
- Bedell G. N., Ostiguy G. L. Transfer factor for carbon monoxide in patients with airways obstruction. Clin Sci. 1967 Apr;32(2):239–248. [PubMed] [Google Scholar]
- CADIGAN J. B., MARKS A., ELLICOTT M. F., JONES R. H., GAENSLER E. A. An analysis of factors affecting the measurement of pulmonary diffusing capacity by the single breath method. J Clin Invest. 1961 Aug;40:1495–1514. doi: 10.1172/JCI104380. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Finucane K. E., Colebatch H. J. Elastic behavior of the lung in patients with airway obstruction. J Appl Physiol. 1969 Mar;26(3):330–338. doi: 10.1152/jappl.1969.26.3.330. [DOI] [PubMed] [Google Scholar]
- Fuleihan F. J., Feisal K. A., Malouf N. N. Effect of corticosteroids on pulmonary function in chronic bronchitis with airway obstruction. Am Rev Respir Dis. 1967 Oct;96(4):678–684. doi: 10.1164/arrd.1967.96.4.678. [DOI] [PubMed] [Google Scholar]
- Gold W. M., Kaufman H. S., Nadel J. A. Elastic recoil of the lungs in chronic asthmatic patients before and after therapy. J Appl Physiol. 1967 Oct;23(4):433–438. doi: 10.1152/jappl.1967.23.4.433. [DOI] [PubMed] [Google Scholar]
- JONES R. S., MEADE F. A theoretical and experimental analysis of anomalies in the estimation of pulmonary diffusing capacity by the single breath method. Q J Exp Physiol Cogn Med Sci. 1961 Apr;46:131–143. doi: 10.1113/expphysiol.1961.sp001525. [DOI] [PubMed] [Google Scholar]
- JOUASSET D. [Standardization of respiratory function tests in countries of the European coal and steel region]. Poumon Coeur. 1960 Dec;16:1145–1159. [PubMed] [Google Scholar]
- KANAGAMI H., KATSURA T., SHIROISHI K., BABA K., EBINA T. Studies on the pulmonary diffusing capacity by the carbon monoxide breath holding technique. II. Patients with various pulmonary diseases. Acta Med Scand. 1961 May;169:595–609. doi: 10.1111/j.0954-6820.1961.tb07869.x. [DOI] [PubMed] [Google Scholar]
- MORTON J. W., OSTENSOE L. G. A CLINICAL REVIEW OF THE SINGLE BREATH METHOD OF MEASURING THE DIFFUSING CAPACITY OF THE LUNGS. Dis Chest. 1965 Jul;48:44–54. doi: 10.1378/chest.48.1.44. [DOI] [PubMed] [Google Scholar]
- McFadden E. R., Jr, Lyons H. A. Arterial-blood gas tension in asthma. N Engl J Med. 1968 May 9;278(19):1027–1032. doi: 10.1056/NEJM196805092781901. [DOI] [PubMed] [Google Scholar]
- McGRATH M. W., THOMSON M. L. The effect of age, body size and lung volume change on alveolar-capillary permeability and diffusing capacity in man. J Physiol. 1959 Jun 11;146(3):572–582. doi: 10.1113/jphysiol.1959.sp006212. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Meisner P., Hugh-Jones P. Pulmonary function in bronchial asthma. Br Med J. 1968 Feb 24;1(5590):470–475. doi: 10.1136/bmj.1.5590.470. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Palmer K. N., Diament M. L. Dynamic and static lung volumes and blood-gas tensions in bronchial asthma. Lancet. 1969 Mar 22;1(7595):591–593. doi: 10.1016/s0140-6736(69)91531-1. [DOI] [PubMed] [Google Scholar]
- Pecora L. J., Bernstein I. L., Feldman D. P. Pulmonary diffusing capacity, membrane diffusing capacity, and capillary blood volume in children with intractable asthma with and without chronic overinflation of the lungs. J Allergy. 1966 Apr;37(4):204–215. doi: 10.1016/0021-8707(66)90115-8. [DOI] [PubMed] [Google Scholar]
- Piiper J., Sikand R. S. Determination of D-CO by the single breath method in inhomogeneous lungs: theory. Respir Physiol. 1966;1(1):75–87. doi: 10.1016/0034-5687(66)90030-2. [DOI] [PubMed] [Google Scholar]
- SMITH J. R., HAMILTON L. H. D-L-CO measurements with gas chromatography. J Appl Physiol. 1962 Nov;17:856–860. doi: 10.1152/jappl.1962.17.6.856. [DOI] [PubMed] [Google Scholar]
- Simpson H., Forfar J. O., Grubb D. J. Arterial blood gas tensions and pH in acute asthma in childhood. Br Med J. 1968 Aug 24;3(5616):460–464. doi: 10.1136/bmj.3.5616.460. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Stanescu D. C., Teculescu D. B., Pacuraru R., Popa V. Effect of bronchoconstrictor aerosols on the alveolar plateau of the single breath O2 test. Thorax. 1968 Nov;23(6):628–633. doi: 10.1136/thx.23.6.628. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Stănescu D. C., Teculescu D. B. Effect of acetylcholine aerosols on diffusing capacity in asthmatic and normal subjects. J Appl Physiol. 1969 Feb;26(2):197–202. doi: 10.1152/jappl.1969.26.2.197. [DOI] [PubMed] [Google Scholar]
- Tai E., Read J. Blood-gas tensions in bronchial asthma. Lancet. 1967 Mar 25;1(7491):644–646. doi: 10.1016/s0140-6736(67)92541-x. [DOI] [PubMed] [Google Scholar]
- Weng T. R., Levison H. Pulmonary function in children with asthma at acute attack and symptom-free status. Am Rev Respir Dis. 1969 May;99(5):719–728. doi: 10.1164/arrd.1969.99.5.719. [DOI] [PubMed] [Google Scholar]
- Woolcock A. J., Read J. Lung volumes in exacerbations of asthma. Am J Med. 1966 Aug;41(2):259–273. doi: 10.1016/0002-9343(66)90021-0. [DOI] [PubMed] [Google Scholar]