Abstract
The use of human serum albumin labelled with iodine-131 (RIHSA) as the radioactive indicator in the measurement of cardiac output by the external counting technique is not ideal since the emission characteristics, physical half-life, and physiological fate restrict the amount that can be administered. A more suitable material, especially because of the short physical half-life of the isotope involved, is albumin labelled with technetium-99m.
This communication describes a simple three-stage process for the preparation of such a complex which was then tested in subjects with no impairment of cardiac performance for its suitability in assays of cardiac output by the external counting method. Values were within the same range as those obtained with RIHSA in comparable subjects. Blood volumes estimated with 99mTc-albumin were within the limits of physiological variation of values derived with RIHSA in the same subjects.
Serial blood samplings and urine collection during a period of 24 hours after administration showed that the preparation was lost continuously from the circulation at a more rapid rate than RIHSA. The greatest loss was in the first few hours when most of the urinary excretion of the isotope occurred. Comparison of the present data with published results using an alternative preparation suggests that our product may be more stable.
Full text
PDF





Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- ALLEN T. H., PENG M. T., CHEN K. P., HUANG T. F., CHANG C., FANG H. S. Prediction of blood volume and adiposity in man from body weight and cube of height. Metabolism. 1956 May;5(3):328–345. [PubMed] [Google Scholar]
- Beazley J. M., Matthews J. C., Leaver E. P., Smith G. M. Placental localization using 99m technetium-labelled serum albumin. J Obstet Gynaecol Br Commonw. 1968 Apr;75(4):470–473. doi: 10.1111/j.1471-0528.1968.tb00146.x. [DOI] [PubMed] [Google Scholar]
- HUFF R. L., FELLER D. D., JUDD O. J., BOGARDUS G. M. Cardiac output of men and dogs measured by in vivo analysis of iodinated (I 131) human serum albumin. Circ Res. 1955 Nov;3(6):564–569. doi: 10.1161/01.res.3.6.564. [DOI] [PubMed] [Google Scholar]
- Herbert R. J., Hibbard B. M., Sheppard M. A. Metabolic behavior and radiation dosimetry of 99mTc-albumin in pregnancy. J Nucl Med. 1969 May;10(5):224–232. [PubMed] [Google Scholar]
- Kloster F. E., Bristow J. D., Starr A., McCord C. W., Griswold H. E. Serial cardiac output and blood volume studies following cardiac valve replacement. Circulation. 1966 Apr;33(4):528–539. doi: 10.1161/01.cir.33.4.528. [DOI] [PubMed] [Google Scholar]
- MCAFEE J. G., STERN H. S., FUEGER G. F., BAGGISH M. S., HOLZMAN G. B., ZOLLE I. 99M-TC LABELED SERUM ALBUMIN FOR SCINTILLATION SCANNING OF THE PLACENTA. J Nucl Med. 1964 Dec;5:936–946. [PubMed] [Google Scholar]
- SORENSEN L. B., ARCHAMBAULT M. VISUALIZATION OF THE LIVER BY SCANNING WITH MO99 (MOLYBDATE) AS TRACER. J Lab Clin Med. 1963 Aug;62:330–340. [PubMed] [Google Scholar]
- STERN H. S., ZOLLE I., MCAFEE J. G. PREPARATION OF TECHNETIUM (TC99M)-LABELED SERUM ALBUMIN (HUMAN). Int J Appl Radiat Isot. 1965 Apr;16:283–288. doi: 10.1016/0020-708x(65)90182-1. [DOI] [PubMed] [Google Scholar]
- Walker R. H., Kohorn E. I. Placental localization by scintillation scanning using 99m technetium labelled human serum albumin. J Obstet Gynaecol Br Commonw. 1968 Apr;75(4):464–469. doi: 10.1111/j.1471-0528.1968.tb00145.x. [DOI] [PubMed] [Google Scholar]
