Ebola virus is one cause of viral hemorrhagic fever (VHF) and the cause of the current outbreak in West Africa. Diagnostic modalities vary in detecting VHF, and this article reviews current assays available for diagnosing suspected VHF.
Keywords: viral hemorrhagic fever, diagnostics, Ebola
Abstract
There are 4 families of viruses that cause viral hemorrhagic fever (VHF), including Filoviridae. Ebola virus is one virus within the family Filoviridae and the cause of the current outbreak of VHF in West Africa. VHF-endemic areas are found throughout the world, yet traditional diagnosis of VHF has been performed in large reference laboratories centered in Europe and the United States. The large amount of capital needed, as well as highly trained and skilled personnel, has limited the availability of diagnostics in endemic areas except in conjunction with governmental and nongovernmental entities. However, rapid diagnosis of VHF is essential to efforts that will limit outbreaks. In addition, increased global travel suggests VHF diagnoses may be made outside of the endemic areas. Thus, understanding how to diagnose VHF is imperative for laboratories worldwide. This article reviews traditional and current diagnostic modalities for VHF.
INTRODUCTION
Viral hemorrhagic fevers (VHFs) are caused by 4 families of viruses (Arenaviridae, Bunyaviridae, Filoviridae, and Flaviviridae), with multiple genera and species causing disease (Table 1). All 4 viral families are single-stranded RNA viruses that have a lipid envelope, which makes them susceptible to detergents and environments with low pH; however, they are stable in blood and cold storage [1]. The 4 families of viruses are zoonoses, with reservoirs recognized for all species except for Ebola virus (EBOV). Fruit bats are assumed to be the reservoir, but only serological evidence and viral sequences of EBOV have been detected [2]. Arenaviruses, Crimean-Congo hemorrhagic fever virus (CCHFV), and filoviruses can be transmitted from human to human by contact with blood and other body fluids, potentially expanding exposed individual cases into epidemic outbreaks, including the current EBOV disease outbreak in western Africa [3].
Table 1.
Family | Genus | Species | Virus Member Abbreviation |
---|---|---|---|
Arenaviridae | |||
Mammarenavirus (Old World) | Lassa mammarenavirus | LASV | |
Lujo mammarenavirus | LUJV | ||
Mammarenavirus (New World) | Chapare mammarenavirus | CHPV | |
Guanarito mammarenavirus | GTOV | ||
Junín mammarenavirus | JUNV | ||
Machupo mammarenavirus | MACV | ||
Sabiá mammarenavirus | SABV | ||
Bunyaviridae | |||
Nairovirus | Crimean-Congo hemorrhagic fever virus | CCHFV | |
Phlebovirus | Henan fever virusa | HNFV | |
Huaiyangshan virusa | HYSV | ||
Rift Valley fever virus | RVFV | ||
Severe fever and thrombocytopenia syndrome virusa | SFTSV | ||
Hantavirus | Dobrava-Belgrade virus | DOBV | |
Hantaan virus | HTNV | ||
Puumalavirus | PUUV | ||
Saaremaa virus | SAAV | ||
Seoul virus | SEOV | ||
Sin Nombre virus | SNV | ||
Tula virus | TULV | ||
Filoviridae | |||
Ebolavirus | Bundibugyo ebolavirus | BDBV | |
Sudan ebolavirus | SUDV | ||
Taï Forest ebolavirus (formerly Cote d'Ivoire) | TAFV | ||
Zaire ebolavirus | EBOV | ||
Marburgvirus | Marburg marburgvirus | MARV | |
Flaviviridae | |||
Flavivirus | Dengue virus | DENV-1-4 | |
Kyasanur forest disease virus | KFDV | ||
Omsk hemorrhagic fever virus | OHFV | ||
Yellow fever virus | YFV |
a Virus not classified as a species in the International Committee of Taxonomy of Viruses, 2014 release [8].
Signs and Symptoms of Viral Hemorrhagic Fevers
VHFs were initially classified together due to the common signs and symptoms of the disease processes. Patients may initially present with fever and general malaise similar to what is seen with other common tropical diseases, including malaria and typhoid. The rarity of VHF, along with indiscriminating symptoms, make diagnosing VHF problematic, even after the fulminant disease process has begun. Distinguishing VHF from other tropical diseases is important, not only for isolation and infection control procedures, which can help stop the spread of VHF, but for proper management of VHF and/or coexisting diseases.
Several groups have looked at common laboratory parameters to determine if specific laboratory values may help delineate VHF from other diseases. Blood urea nitrogen and creatinine were elevated in patients with hemorrhagic fever with renal syndrome caused by Hantaan virus and Seoul virus, while Huaiyangshan hemorrhagic fever virus–infected patients were found to have leukopenia and increased creatine kinase and alanine aminotransferase (ALT) [4]. Leukopenia, thrombocytopenia, and increased ALT and aspartate aminotransferase (AST) have been observed in patients with CCHFV [5], Sudan virus disease, and EBOV disease [6, 7]. Hematology parameters in areas endemic for Dengue hemorrhagic fever indicated that platelet counts of <100 × 109/L, a prolonged activated partial thromboplastin time, normal prothrombin time, and elevated aspartate aminotransferase and ALT are useful in evaluating the likelihood of Dengue hemorrhagic fever [9]. Other studies have shown a high C-reactive protein concentration (>5 mg/L) is more predictive of malaria than Dengue hemorrhagic fever [10]. These laboratory values are not highly specific for diagnosing VHF. However, in areas where direct diagnostic techniques for VHF are not readily available, laboratory markers may offer guidance and direction for identifying patients with VHF. Higher sensitivity and specificity in detecting VHF is demonstrated in laboratory methods that directly detect virus or humoral immune response to virus from patient specimens. Serological markers for measuring virus-specific immunoglobulin M (IgM) and IgG in patient serum offer a potential delineator of disease that lacks the technical and logistical restraints of the gold standard of molecular detection. This has been effectively demonstrated for Lassa and the early detection of IgM for Lassa virus (LASV) and IgG for Rift Valley fever virus (RVFV) infections [11, 12].
DIAGNOSTIC METHODS
Laboratory Diagnosis
Laboratory diagnosis of VHF has traditionally taken place in highly specialized reference laboratories. These laboratories have been classified with biosafety levels (BSL) ranging from 1 to 4 by the World Health Organization. The laboratories are categorized according to the laboratory design, containment facility, and handling of biological agents classified into 4 specific risk groups (RG 1–4) [13]. RG-1 contains pathogens not likely to cause disease in healthy individuals. Organisms that can cause disease in humans but are not likely to be a serious threat to laboratory workers are in RG-2. Known treatment regimens or preventive measures are available for these organisms. RG-3 contains organisms that can cause serious diseases in humans but do not ordinarily spread from one person to another. These pathogens have known prevention and treatment measures. Lastly, pathogens that are likely to cause serious disease in humans and can be readily transmitted from one person to another are classified as RG-4 agents. Usually no approved treatment or preventive measures are available for this RG [13]. According to the Centers for Disease Control and Prevention, the VHF viruses are members of RG-2 through RG-4 [14]. Dengue virus (DENV) is the only organism that does not fall into BSL-3 or BSL-4 laboratory practices. There are a limited number of BSL-4 laboratories throughout Europe, the United States, and Africa, and the distance of BSL-4 laboratories from endemic areas often lengthens time to diagnosis when most needed. Some countries, but not all with endemic VHF, often make diagnoses in their laboratories, but they are not BSL-4 certified. Financial means and lack of highly trained personnel, equipment, and supply lines that would ensure maintenance of a cold-chain system limit the capabilities of these laboratories. Personal protective equipment can be modified to be effective in these resource-limited environments.
Virus Culture and Electron Microscopy
Culture of live agents was considered the gold standard but is rapidly being challenged by polymerase chain reaction (PCR) and next generation sequencing [15]. Culture of live agents remains helpful for characterization of new or divergent viruses, but next generation sequencing can also aid in identifying these viruses. Electron microscopy (EM) may be used to identify virus based on structural characteristics from clinical materials or culture [16]. Agent-specific antibodies in conjunction with EM may be used to further identify or classify an agent and to increase the sensitivity of this method, depending on the protocol used. Culture of live virus and preparation of samples for EM requires access to highly specialized laboratories, and completion of these procedures can be lengthy, taking weeks for the virus to grow and additional time to perform the microscopy. As a result, these methods are no longer used as a first line of diagnosis in many instances.
Nucleic Acid Detection
Nucleic acid detection has become a common diagnostic tool for identifying viral diseases, including VHF. Such detection surpasses the limit of detection for many culture methods and eliminates the need for the virus to be viable at the time of testing. Nucleic acid extraction techniques vary, but 2 common reagents—TRIzol (Life Technologies, Grand Island, New York) reagent and AVL plus ethanol buffer (Qiagen, Germany)—were shown to inactivate filoviruses, flaviviruses, and bunyaviruses [17], decreasing exposure to live virus for laboratory personnel once placed into these buffers. In addition, another group found their system (Tripure, Roche, Switzerland) could also inactivate filoviruses when used per manufacturer guidelines [18]. The RNA extracted after these methods are performed is fairly stable, which facilitates the ease of shipping and transport to other laboratories.
Reverse transcription PCR (RT-PCR) has become the cornerstone for molecular diagnosis, and RT-PCR assays have been developed for the majority of VHF-associated viruses [19–22]. Detecting 1 pathogen at a time using these assays has had limitations in areas where more than 1 VHF pathogen is endemic. Multiplex assays for VHF were first described in 2002 with the ability to detect EBOV, Marburg virus (MARV), LASV, CCHFV, RVFV, DENV, and yellow fever virus (YFV) [22]. Multiplex assays have now been developed for a range of VHFs with sensitivity and specificity comparable to other RT-PCR assays; 1 study showed a limit of detection ranging from 1 × 10−2 to 1 × 105 copies/mL [23] and another study detected viruses at 0.0001 to 10 plaque forming units (PFU)/mL [24]. Assays available at standard reference laboratories, such as Associated Regional and University Pathologists Laboratories (Salt Lake City, Utah) and Mayo Medical Laboratories (Rochester, Minnesota), include serologic testing for DENV and Hanta virus and RT-PCR for DENV.
Microarrays are a specialized type of multiplex PCR that uses a solid matrix spotted with oligonucleotides that represent specific genes of different organisms. An unknown fluorescently labeled DNA anneals and releases a positive signal that is compared with the intensity of known positive signals. Microarrays have a high specificity and sensitivity to detect all 4 virus families that encompass VHF [25]. FilmArray (Biofire, Salt Lake City, Utah) has developed a qualitative biodefense panel for detecting EBOV and MARV [26] that has the capability of rapid field diagnostics. Implementation of this panel in the field would necessitate investment in capital equipment related to this test, as well as an investment in the test pouches, which are used once and discarded. The advantages of the test pouches are that they are lyophilized and stable; the disadvantage is that the pouches have a short shelf life (6 months after the date of manufacture).
Field Diagnostics
In outbreak settings, results from RT-PCR were traditionally sent to international reference laboratories [27] with a long turnaround time. Towner et al developed a protocol for field diagnostics in a mobile laboratory unit using quantitative RT-PCR [18]. The mobile laboratory unit (which was co-located with the hospital) was implemented during an outbreak of MARV in Angola and had the ability to diagnose patients in less than 4 hours [27]. Serum or plasma, collected as whole blood in EDTA-coated tubes (heparin is avoided since it inhibits PCR), has been the specimen of choice for nucleic acid testing; however, in some countries, phlebotomy is not culturally acceptable [27, 28]. Oral and nasal swabs have been used but can be insensitive depending on the variability in the swabbing technique that resulted from lack of training. Suspected patients who are negative by swab still need to be tested by more sensitive quantitative molecular testing [27, 28]. Use of rapid diagnostic tests in outbreak settings makes contact tracing in a timely manner. Rather than waiting days for results after shipping specimens to a laboratory and waiting for transmission of results back to the field, results are available within a few hours. This allows for more rapid identification of individuals who have had contact with patients with disease and helps prevent further transmission [27]. In addition to the MARV outbreak, a portable thermocycler helped diagnose patients in as little as 3 hours of arrival to a hospital during a RVFV outbreak, leading to quick and appropriate treatment for patients with disease [29].
Another molecular assay with potential for field diagnostics is loop-mediated isothermal amplification (LAMP). This method amplifies nucleic acids using 2 nested primers, and the reaction takes place at a single temperature (65°C), omitting the need for expensive thermocyclers [30, 31]. The product can be measured in real time by turbidometry or through an intercalating dye [30]. One LAMP assay that has been developed for RVFV produces results within 2 hours, including RNA extraction [31]. LAMP assays have been developed for detection of severe fever and thrombocytopenia syndrome virus, YFV, CCHFV, MARV, DENV, and EBOV [32–37]. LAMP and other RT-PCR assays are becoming more widely available; however, the capability for diagnostic testing with RT-PCR is not always an option in endemic areas, due to lack of funding and infrastructure.
Diagnostics that use antigen detection by immunochromatography require little training, use minimal amounts of patient sample, and do not require electricity. These antigen assays are also less susceptible to viral drift or evolution, since accumulated mismatches in the RT-PCR primers and probes can impact the performance of molecular tests. An immunofiltration test is available for EBOV and can detect viral proteins from urine within 30 minutes. The sensitivity is less than that of RT-PCR but comparable to that of other available antigen tests [38]. A rapid diagnostic kit for DENV that can detect both the NS1 antigen and antibodies to DENV by immunochromatography was tested in Cambodia during an outbreak and had high sensitivity but low negative predictive value [39]. Immunochromatographic techniques have also been developed for RVFV and Hanta virus but have not been used in diagnosing human infections [40, 41]. A lateral flow immunoassay has been developed and used in diagnosing LASV when patients are viremic [42]. Currently, an emergency use authorization has been issued for the ReEBO Antigen Rapid (15 minutes) Test (Corginex, Broomfield, Colorado), a lateral flow assay developed for detection of EBOV and Sudan ebolavirus VP40 antigen with a sensitivity found acceptable in preliminary studies (Table 2) [43–45]. The Defense Science and Technology Laboratory of the United Kingdom deployed a lateral flow assay in the current EBOV disease outbreak in Sierra Leone [46].
Table 2.
Test | Manufacturer | Target | Method of Detection | Machine | EUA (Date) | EUA Link |
---|---|---|---|---|---|---|
EZ-1 | DOD | GP | qRT-PCR | ABI 7500, light cycler, JBAIDS | Yes (10 October 2014) | EZ-1.pdf |
CDC VP40 | CDC | VP40 | qRT-PCR | ABI 7500 fast DX | Yes (10 October 2014) | CDC VP40.pdf |
CDC NP | CDC | NP | qRT-PCR | ABI 7500 fast DX | Yes (10 October 2014) | CDC NP.pdf |
Biothreat E-test | Biofire | Not identified | qRT-PCR | Film array instrument | Yes (25 October 2014) | Biothreat E-test.pdf |
NGDS BT-E Assay | Biofire | Not identified | qRT-PCR | Film array instrument | Yes (25 October 2014) | NGDS BT-E Assay.pdf |
RealStar Ebolavirus Kit 1.0 | Altona Diagnostics GMBH | Ebola L gene (RDRP) | qRT-PCR | ABI 7500, LightCycler 480, CFX96 | Yes (26 November 2014) | RealStar Ebolavirus Kit 1.0.pdf |
LightMix Ebola Zaire rRT-PCR | Roche | Ebola L gene (RDRP) | qRT-PCR | LightCycler 480 instrument and/or COBAS z 480 analyzer | Yes (23 December 2014) | LightMix Ebola Zaire rRT-PCR.pdf |
ReEBOV Antigen Rapid Test | Corgenix Inc. | VP40 | Lateral flow immunoassay | N/A | Yes (24 February 2015) | ReEBOV Antigen Rapid Test.pdf |
US Food and Drug Administration EUA approvals: http://www.fda.gov/MedicalDevices/Safety/EmergencySituations/ucm161496.htm.
Abbreviations: CDC, Centers for Disease Control and Prevention; DOD, Department of Defense; EUA, emergency use authorization; GP, glycoprotein; JBAIDS, Joint Biological Agent Identification and Diagnostic System; NP, nucleoprotein; qRT-PCR, quantitive real-time reverse transcription polymerase chain reaction; RDRP, RNA-dependent RNA polymerase; VP40, viral matrix protein.
Other Diagnostic Modalities
Enzyme-linked immunosorbent assay is the most common method for detecting IgM and IgG antibodies. Serology is not useful in diagnosing acute VHF illness, as the presence of IgM antibodies can represent different stages of disease or a prior symptomatic or asymptomatic infection. The diagnosis of recent VHF may need additional blood draws to determine if the patient has an increasing IgM titer [47]. In endemic areas, a positive IgG may mean little in trying to diagnose an acute infection [48]. Serologic diagnosis often lacks specificity with high cross-reactivity between closely related viruses, especially within Bunyaviridae and Flaviviridae [49]. Despite the issues with serologic methods, including known cross-reactivity among the family of viruses [50], serology is the gold standard and the most common method for diagnosing bunyaviruses, due to short viremic periods and rapid clearance of the virus by the immune system [47, 49].
Immunohistochemistry
Immunohistochemical staining of skin biopsies infected with EBOV described by Zaki et al was concordant with other diagnostic modalities used for confirming EBOV disease [51]. A skin biopsy is fixed in formalin, which renders the virus noninfectious. The specialized laboratory processes required for this procedure do not allow for a rapid diagnosis but could be used as a surveillance tool or an alternative to autopsy in deceased patients.
LABORATORY INFECTION PREVENTION
Diagnosing VHF can cause anxiety for laboratory personnel [52], who fear they will become infected while working with contagious laboratory specimens. In areas with appropriate resources, including heat and detergent, laboratory specimens can be inactivated by gamma irradiation [53] and with RNA extraction techniques [17]. Even without inactivation, procedures for proper use of protective equipment and training have helped to stop transmission during VHF outbreaks [54] and, hence, to limit transmission to laboratory personnel.
CONCLUSION
Molecular detection by RT-PCR in blood is the most sensitive assay for diagnosing known VHF in symptomatic patients. However, these assays have traditionally not been widely available outside of BSL-4 reference laboratories. Recent advances in field testing have made assays for VHF available to those in endemic areas but still require capital investment, highly trained personnel, and advanced technology from outside nations. Future advancements in diagnostic testing may occur as a result of biomarkers or other host signatures that can predict active disease [55].
Future test development needs to include increasing the sensitivity and specificity of rapid testing that can be performed in resource-limited settings, where humidity and temperature stability are not favorable. These tests are critical to rapid triage and care of patients, where individuals with a positive result can be quarantined and other individuals with compelling symptoms can be retested or undergo more sensitive molecular testing. These approaches will ultimately lead to faster contact tracing and containment of disease outbreaks.
Notes
Acknowledgments. The authors acknowledge Laura Bollinger for editing the manuscript.
Disclaimer. Funding organizations were not involved in the preparation, review, or approval of the manuscript. The content is solely the responsibility of the authors and does not represent the official views of the National Institutes of Health.
Potential conflicts of interest. All authors: No reported conflicts. All authors have submitted the ICMJE Form for Disclosure of Potential Conflicts of Interest. Conflicts that the editors consider relevant to the content of the manuscript have been disclosed.
References
- 1.Marty AM, Jahrling PB, Geisbert TW. Viral hemorrhagic fevers. Clin Lab Med 2006; 26:345–86, viii. [DOI] [PubMed] [Google Scholar]
- 2.Leroy EM, Kumulungui B, Pourrut X, et al. Fruit bats as reservoirs of Ebola virus. Nature 2005; 438:575–6. [DOI] [PubMed] [Google Scholar]
- 3.Baize S, Pannetier D, Oestereich L, et al. Emergence of Zaire Ebola virus disease in Guinea. N Engl J Med 2014; 371:1418–25. [DOI] [PubMed] [Google Scholar]
- 4.Chen ZH, Qin XC, Song R, et al. Co-circulation of multiple hemorrhagic fever diseases with distinct clinical characteristics in Dandong, China. PloS One 2014; 9:e89896. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 5.Mostafavi E, Pourhossein B, Chinikar S. Clinical symptoms and laboratory findings supporting early diagnosis of Crimean-Congo hemorrhagic fever in Iran. J Med Virol 2014; 86:1188–92. [DOI] [PubMed] [Google Scholar]
- 6.Rollin PE, Bausch DG, Sanchez A. Blood chemistry measurements and D-dimer levels associated with fatal and nonfatal outcomes in humans infected with Sudan Ebola virus. J Infect Dis 2007; 196(suppl 2):S364–71. [DOI] [PubMed] [Google Scholar]
- 7.Kraft CS, Hewlett AL, Koepsell S, et al. The use of TKM-100802 and convalescent plasma in 2 patients with Ebola virus disease in the United States. Clin Infect Dis 2015; 61:496–502. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 8.International Committee of Taxonomy of Viruses, 2014 release. Available at: http://www.ictvonline.org/virusTaxonomy.asp. Accessed 11 September 2015. [Google Scholar]
- 9.Liu JW, Lee IK, Wang L, Chen RF, Yang KD. The usefulness of clinical-practice-based laboratory data in facilitating the diagnosis of dengue illness. Biomed Res Int 2013; doi:10.1155/2013/198797. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 10.Epelboin L, Boulle C, Ouar-Epelboin S, et al. Discriminating malaria from dengue fever in endemic areas: clinical and biological criteria, prognostic score and utility of the C-reactive protein: a retrospective matched-pair study in French Guiana. PLoS Negl Trop Dis 2013; 7:e2420. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 11.Bukbuk DN, Fukushi S, Tani H, et al. Development and validation of serological assays for viral hemorrhagic fevers and determination of the prevalence of Rift Valley fever in Borno State, Nigeria. Trans R Soc Trop Med Hyg 2014; 108:768–73. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 12.Ibekwe TS, Nwegbu MM, Asogun D, Adomeh DI, Okokhere PO. The sensitivity and specificity of Lassa virus IgM by ELISA as screening tool at early phase of Lassa fever infection. Niger Med J 2012; 53:196–9. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 13.World Health Organization. Laboratory Biosafety Manual. Geneva, CH: World Health Organization, 2004. Available at: http://www.who.int/csr/resources/publications/biosafety/Biosafety7.pdf?ua=1 Accessed 9 June 2015. [Google Scholar]
- 14.Chosewood LC, Wilson DE, eds. Biosafety in Microbiological and Biomedical Laboratories. 5th ed. Washington, DC: US Department of Health and Human Services, 2009. Available at: http://www.cdc.gov/biosafety/publications/bmbl5/. Accessed 4 September 2014. [Google Scholar]
- 15.Gire SK, Goba A, Andersen KG, et al. Genomic surveillance elucidates Ebola virus origin and transmission during the 2014 outbreak. Science 2014; 345:1369–72. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 16.Goldsmith CS, Ksiazek TG, Rollin PE, et al. Cell culture and electron microscopy for identifying viruses in diseases of unknown cause. Emerg Infect Dis 2013; 19:886–91. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 17.Blow JA, Dohm DJ, Negley DL, Mores CN. Virus inactivation by nucleic acid extraction reagents. J Virol Methods 2004; 119:195–8. [DOI] [PubMed] [Google Scholar]
- 18.Towner JS, Sealy TK, Ksiazek TG, Nichol ST. High-throughput molecular detection of hemorrhagic fever virus threats with applications for outbreak settings. J Infect Dis 2007; 196(suppl 2):S205–12. [DOI] [PubMed] [Google Scholar]
- 19.Towner JS, Rollin PE, Bausch DG, et al. Rapid diagnosis of Ebola hemorrhagic fever by reverse transcription-PCR in an outbreak setting and assessment of patient viral load as a predictor of outcome. J Virol 2004; 78:4330–41. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 20.Escadafal C, Faye O, Sall AA, et al. Rapid molecular assays for the detection of yellow fever virus in low-resource settings. PLoS Negl Trop Dis 2014; 8:e2730. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 21.Mohamed N, Nilsson E, Johansson P, et al. Development and evaluation of a broad reacting SYBR-green based quantitative real-time PCR for the detection of different hantaviruses. J Clin Virol 2013; 56:280–5. [DOI] [PubMed] [Google Scholar]
- 22.Drosten C, Gottig S, Schilling S, et al. Rapid detection and quantification of RNA of Ebola and Marburg viruses, Lassa virus, Crimean-Congo hemorrhagic fever virus, Rift Valley fever virus, dengue virus, and yellow fever virus by real-time reverse transcription-PCR. J Clin Microbiol 2002; 40:2323–30. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 23.He J, Kraft AJ, Fan J, et al. Simultaneous detection of CDC category “A” DNA and RNA bioterrorism agents by use of multiplex PCR & RT-PCR enzyme hybridization assays. Viruses 2009; 1:441–59. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 24.Trombley AR, Wachter L, Garrison J, et al. Comprehensive panel of real-time TaqMan polymerase chain reaction assays for detection and absolute quantification of filoviruses, arenaviruses, and New World hantaviruses. Am J Trop Med Hyg 2010; 82:954–60. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 25.Leski TA, Lin B, Malanoski AP, et al. Testing and validation of high density resequencing microarray for broad range biothreat agents detection. PloS One 2009; 4:e6569. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 26.Southern TR, Racsa LD, Albarino CG, et al. Comparison of FilmArray(R) and qRT-PCR for the detection of Zaire ebolavirus from contrived and clinical specimens. J Clin Microbiol 2015; 53:2956–60. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 27.Grolla A, Jones SM, Fernando L, et al. The use of a mobile laboratory unit in support of patient management and epidemiological surveillance during the 2005 Marburg outbreak in Angola. PLoS Negl Trop Dis 2011; 5:e1183. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 28.Formenty P, Leroy EM, Epelboin A, et al. Detection of Ebola virus in oral fluid specimens during outbreaks of Ebola virus hemorrhagic fever in the Republic of Congo. Clin Infect Dis 2006; 42:1521–6. [DOI] [PubMed] [Google Scholar]
- 29.Njenga MK, Paweska J, Wanjala R, et al. Using a field quantitative real-time PCR test to rapidly identify highly viremic rift valley fever cases. J Clin Microbiol 2009; 47:1166–71. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 30.Wolk D, Hayden R. Quantitative molecular methods. In: Persing D, Tenover F, Tang Y, Nolte F, Hayden R, van Belkum A, eds. Molecular microbiology: diagnostic principles and practice. 2nd ed. Washington, DC: ASM Press, 2011:38–46. [Google Scholar]
- 31.Le Roux CA, Kubo T, Grobbelaar AA, et al. Development and evaluation of a real-time reverse transcription-loop-mediated isothermal amplification assay for rapid detection of Rift Valley fever virus in clinical specimens. J Clin Microbiol 2009; 47:645–51. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 32.Kwallah A, Inoue S, Muigai AW, et al. A real-time reverse transcription loop-mediated isothermal amplification assay for the rapid detection of yellow fever virus. J Virol Methods 2013; 193:23–7. [DOI] [PubMed] [Google Scholar]
- 33.Xu H, Zhang L, Shen G, et al. Establishment of a novel one-step reverse transcription loop-mediated isothermal amplification assay for rapid identification of RNA from the severe fever with thrombocytopenia syndrome virus. J Virol Methods 2013; 194:21–5. [DOI] [PubMed] [Google Scholar]
- 34.Osman HA, Eltom KH, Musa NO, Bilal NM, Elbashir MI, Aradaib IE. Development and evaluation of loop-mediated isothermal amplification assay for detection of Crimean Congo hemorrhagic fever virus in Sudan. J Virol Methods 2013; 190:4–10. [DOI] [PubMed] [Google Scholar]
- 35.Kurosaki Y, Grolla A, Fukuma A, Feldmann H, Yasuda J. Development and evaluation of a simple assay for Marburg virus detection using a reverse transcription-loop-mediated isothermal amplification method. J Clin Microbiol 2010; 48:2330–6. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 36.Parida M, Horioke K, Ishida H, et al. Rapid detection and differentiation of dengue virus serotypes by a real-time reverse transcription-loop-mediated isothermal amplification assay. J Clin Microbiol 2005; 43:2895–903. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 37.Kurosaki Y, Takada A, Ebihara H, et al. Rapid and simple detection of Ebola virus by reverse transcription-loop-mediated isothermal amplification. J Virol Methods 2007; 141:78–83. [DOI] [PubMed] [Google Scholar]
- 38.Lucht A, Formenty P, Feldmann H, et al. Development of an immunofiltration-based antigen-detection assay for rapid diagnosis of Ebola virus infection. J Infect Dis 2007; 196(suppl 2):S184–92. [DOI] [PubMed] [Google Scholar]
- 39.Andries AC, Duong V, Ngan C, et al. Field evaluation and impact on clinical management of a rapid diagnostic kit that detects dengue NS1, IgM and IgG. PLoS Negl Trop Dis 2012; 6:e1993. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 40.Wanja E, Parker Z, Rowland T, et al. Field evaluation of a wicking assay for the rapid detection of Rift Valley fever viral antigens in mosquitoes. J Am Mosq Control Assoc 2011; 27:370–5. [DOI] [PubMed] [Google Scholar]
- 41.Sirola H, Kallio ER, Koistinen V, et al. Rapid field test for detection of hantavirus antibodies in rodents. Epidemiol Infect 2004; 132:549–53. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 42.Shaffer JG, Grant DS, Schieffelin JS, et al. Lassa fever in post-conflict Sierra Leone. PLoS Negl Trop Dis 2014; 8:e2748. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 43.Oottamasathien D, Jones A, Boisen M, et al. Development of a point-of-care diagnostic for Ebola and Sudan virus detection [abstract B-068]. In: Presented at the American Association for Clinical Chemistry 2014 Annual Meeting and Clinical Lab Expo (Chicago): Clin Chem, 2014; 60 (10 Supplement):s151 Available at: https://www.aacc.org/science-and-research/annual-meeting-abstracts/2014-annual-meeting-abstracts Accessed 9 June 2015. [Google Scholar]
- 44.Hamburg M. ReEBOV Antigen Rapid Test (Corgenix Inc.) Ebola Virus Emergency Use Authorization, March 26, 2015. Silver Spring, MD: Food and Drug Administration, 2015. Available at: http://www.fda.gov/medicaldevices/safety/emergencysituations/ucm161496.htm#ebola Accessed 9 June 2015. [Google Scholar]
- 45.World Health Organization. WHO Emergency Use Authorization and Listing for Ebola Virus Disease IVDs. Public Report. Product: ReEBOV Antigen Rapid Test Kit. Geneva, CH: World Health Organization, 2015. Available at: http://www.who.int/medicines/ebola-treatment/1st_antigen_RT_Ebola/en/ Accessed 9 June 2015. [Google Scholar]
- 46.Walker NF, Brown CS, Youkee D, et al. Evaluation of a point-of-care blood test for identification of Ebola virus disease at Ebola holding units, Western Area, Sierra Leone, January to February 2015. Euro Surveill 2015; 20:pii:21073. [DOI] [PubMed] [Google Scholar]
- 47.Drosten C, Kummerer BM, Schmitz H, Gunther S. Molecular diagnostics of viral hemorrhagic fevers. Antiviral Res 2003; 57:61–87. [DOI] [PubMed] [Google Scholar]
- 48.Jeffs B. A clinical guide to viral haemorrhagic fevers: Ebola, Marburg and Lassa. Trop Doct 2006; 36:1–4. [DOI] [PubMed] [Google Scholar]
- 49.Fajfr M, Ruzek D. Laboratory diagnosis of viral hemorrhagic fevers. In: Singh S, Ruzek D, eds. Viral hemorrhagic fevers. Boca Raton, FL: CRC Press, 2014:183–203. [Google Scholar]
- 50.Papa A, Karabaxoglou D, Kansouzidou A. Acute West Nile virus neuroinvasive infections: cross-reactivity with dengue virus and tick-borne encephalitis virus. J Med Virol 2011; 83:1861–5. [DOI] [PubMed] [Google Scholar]
- 51.Zaki SR, Shieh WJ, Greer PW, et al. A novel immunohistochemical assay for the detection of Ebola virus in skin: implications for diagnosis, spread, and surveillance of Ebola hemorrhagic fever. Commission de Lutte contre les Epidemies a Kikwit. J Infect Dis 1999; 179(suppl 1):S36–47. [DOI] [PubMed] [Google Scholar]
- 52.Parkes-Ratanshi R, Elbireer A, Mbambu B, Mayanja F, Coutinho A, Merry C. Ebola outbreak response; experience and development of screening tools for viral haemorrhagic fever (VHF) in a HIV center of excellence near to VHF epicentres. PloS One 2014; 9:e100333. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 53.Elliott LH, McCormick JB, Johnson KM. Inactivation of Lassa, Marburg, and Ebola viruses by gamma irradiation. J Clin Microbiol 1982; 16:704–8. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 54.Feldmann H, Geisbert TW. Ebola haemorrhagic fever. Lancet 2011; 377:849–62. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 55.Yen JY, Garamszegi S, Geisbert JB, et al. Therapeutics of Ebola hemorrhagic fever: whole-genome transcriptional analysis of successful disease mitigation. J Infect Dis 2011; 204(suppl 3):S1043–52. [DOI] [PubMed] [Google Scholar]