Abstract
Background
Most antibodies recognize conformational or discontinuous epitopes that have a specific 3-dimensional shape; however, determination of discontinuous B-cell epitopes is a major challenge in bioscience. Moreover, the current methods for identifying peptide epitopes often involve laborious, high-cost peptide screening programs. Here, we present a novel microarray method for identifying discontinuous B-cell epitopes in celiac disease (CD) by using a silicon-based peptide array and computational methods.
Methods
Using a novel silicon-based microarray platform with a multi-pillar chip, overlapping 12-mer peptide sequences of all native and deamidated gliadins, which are known to trigger CD, were synthesized in situ and used to identify peptide epitopes.
Results
Using a computational algorithm that considered disease specificity of peptide sequences, 2 distinct epitope sets were identified. Further, by combining the most discriminative 3-mer gliadin sequences with randomly interpolated3- or 6-mer peptide sequences, novel discontinuous epitopes were identified and further optimized to maximize disease discrimination. The final discontinuous epitope sets were tested in a confirmatory cohort of CD patients and controls, yielding 99% sensitivity and 100% specificity.
Conclusions
These novel sets of epitopes derived from gliadin have a high degree of accuracy in differentiating CD from controls, compared with standard serologic tests. The method of ultra-high-density peptide microarray described here would be broadly useful to develop high-fidelity diagnostic tests and explore pathogenesis.
Introduction
Antibody detection is one of the main approaches for the diagnosis of many diseases, including autoimmune disorders, infectious diseases, and cancers.[1–3] Indeed, the development of antibody-based assays has been intensively pursued for the diagnosis and treatment of many diseases; however, only a small number of biomarkers have been identified as effective.[1, 4] With peptide arrays, the overlapping synthetic peptide approach has been used as an effective way to map the epitope specificity of antibodies.[5–7] This method is especially effective for identifying linear antigenic epitopes derived from known target proteins, but has been restricted by the expense and logistics of acquiring and handling large numbers of peptides. Recent advances in semiconductor methods and the generation of high-throughput peptide microarrays using a combination of lithography and biochemistry for peptide synthesis have opened the door to a new era in the identification of novel biomarkers of disease.[5, 8, 9] Here, we describe a novel method for silicon-based peptide microarray with computational algorithm to identify the discontinuous epitopes from native and modified gliadin peptides that glutamic acid was substituted for glutamine, which are highly reactive in patients with celiac disease (CD).
CD is an autoimmune disease of the gastrointestinal tract that is triggered by exposure to dietary gluten, which is a group of storage proteins from wheat, barley, and rye.[10–12] While the pathogenesis of CD appears to be mediated by T cells reactive to gluten,[13–15] the serologic diagnosis relies on the presence of self-reactive antibodies or antibodies to exogenous antigens. However, it is not clear how the pathogenic epitopes are recognized by B cells during the development of CD. This interaction between B and T lymphocytes, which may play a central role in causing tissue destruction, would be crucial to understanding of the mechanism of disease initiation and to development of better clinical tools. We hypothesized that enzymatic modification of gliadin peptides and subsequent discontinuous transformation lead to recognition of the host immune system. Thus, we aimed to describe the novel platform and technology that uses a high-volume manufacturing and computational process derived from semiconductor industrial design to identify highly predictive biomarkers in a common chronic immune disease.
Materials and Methods
Population
To discover a novel biomarker for the diagnosis of CD, sera were collected from 3 sources: a cohort that was part of a previous study (48 biopsy-proven CD cases and 50 controls), [2] a cohort from ARUP Laboratories (42 biopsy-proven CD cases and 29 controls), and a commercially obtained cohort (12 rheumatoid arthritis cases and 7 systemic lupus erythematosus cases). In addition, sera of a confirmatory cohort (306 CD cases and 1,590 controls), which was assembled in the previous study in a community,[16] were used for evaluating the diagnostic utility of identified or newly developed peptide sets from the exploratory cohort. The demographic characteristics of the exploratory and confirmatory cohorts can be found as Table 1. All samples were handled according to standard procedures and stored at -80°C. All samples were probed using 1:101 primary antibody dilution and 1:2,000 secondary antibody dilution and scanned on a Nikon total solution platform consisting of a Hamilton fluidics station and second-generation microarray fluorescence scanner.
Table 1. Clinical Characteristics of the study Population.
N | Age, mean (Range) | Sex, male (%) | Sex, female (%) | |
---|---|---|---|---|
Exploratory population | ||||
Celiac disease | 90 | 39.4 (19.5–60.2) | 43% | 57% |
Rheumatoid arthritis | 12 | 40.6 (20.1–68.8) | 50% | 50% |
Systemic Lupus Erythematosus | 7 | 34.5 (25.7–57.0) | 43% | 57% |
Healthy controls | 79 | 40.2 (19.7–63.3) | 48% | 52% |
Confirmatory population | ||||
Celiac disease | 306 | 35.2 (18.1–49.9) | 38% | 62% |
Rheumatoid arthritis | 75 | 39.0 (20.1–56.7) | 50% | 50% |
Systemic Lupus Erythematosus | 40 | 36.5 (25.3–45.6) | 38% | 62% |
Healthy controls | 1475 | 35.3 (18.5–69.8) | 34% | 66% |
Study Approval
This study was conducted according to the principles expressed in the Declaration of Helsinki. Ethical approval, including informed consent, was obtained from the Mayo Clinic Institutional Review Board. All informed consents were documented by a written consent form approved by the IRB and signed by the subject or the subject's legally authorized representative.
Wafer Substrate Preparation
Fig 1A shows the schematic process of the wafer substrate preparation. Prime-grade 300-mm silicon wafers with p-type boron, (1 0 0) orientation, 1 to 5 Ω·cm-1, and 725-μm thickness were obtained from Process Specialties. The wafers were deposited with 100 nm thermal oxide by dry oxidation at 1,000°C in a furnace under pure oxygen atmosphere for 2 hours. Commercial photoresist P5107 (Rohm and Haas Chemicals) was spin coated on the wafers at 2,000 rpm for 40 seconds using the RF3S Coat/Develop Track (Sokudo). The wafers were exposed with an inverse zero layer mask using the 248-nm wavelength NSR-S205 KrF Scanner (Nikon). This was followed by post-exposure baking at 110°C for 90 seconds and then developing for 30 seconds using the developer NMD-3 2.38% (TOK America). Wet oxide etching of the wafers was performed using buffered hydrofluoric acid, which was prepared by mixing 5 parts of 40 wt% of ammonium fluoride (Sigma-Aldrich) with 1 part of 49 wt% of hydrofluoric acid (Sigma-Aldrich) for 1 minute. This was followed by stripping the wafers with Nano-Strip (KMG Electronic Chemicals, formerly Cyantek) for 24 hours. Wafers were finally washed with deionized water and sonicated in deionized water for 10 minutes. This results in the completion of substrate preparation in which the feature area has height of 100 nm and contains thermal oxide and the non-feature area contains silicon. The Dimension 5000 AFM system (Veeco) was used to measure the roughness and calculate the density of the substrate. Fig 1A shows the process of silicon wafers preparation, and Fig 1B shows the pillars formed after the process was completed. Fig 1C shows the root mean square roughness of the substrate evaluated by Atomic force microscopy (Digital Instruments, Nanoscope III A). The density of the substrate was calculated to be approximately 100 to 150 pM.
The method used to derivatize the wafer and the details of preparing amino acid activation solution cocktails are described in supporting information (S1 Text).
Peptide Array Synthesis
The process for 1-step amine side peptide synthesis is shown in Fig 2. A base resist solution containing 1 wt% of polymer and 3 wt% of piperidine dissolved in N-methylpyrrolidone (NMP) is spin coated onto the wafer at 3,000 rpm for 30 seconds and soft baked at 65°C for 1 minute in a hot plate. Then the wafer is baked at 80°C for 300 seconds. Fluorenylmethyloxycarbonyl (Fmoc) protection is removed in all features, leaving the unprotected amine group. The incoming amino acid activation solution cocktail is spin coated onto a wafer at 3,000 rpm for 30 seconds and soft baked at 65°C for 1 minute in a hot plate. Then the wafer is exposed using a reticle which exposes desired features for which the incoming amino acid needs to be coupled at an exposure dose of 120 mJ/cm2 and then hard baked at 85°C for 90 seconds in a hot plate. On exposure, tetrazole thione releases a carbodiimide, and selective activation of amino acid is achieved in the exposed features. Therefore, the incoming Fmoc amino acid present in the cocktail is activated and coupled to the unprotected amine present on the wafer in the same step, completing the coupling of 1 layer of amino acid. Each layer of coupling comprises reticles for each incoming Fmoc amino acid to be coupled, which exposes features independent of the rest of the reticles used for the same layer. After the completion of all amino acids for a particular layer, the wafer is then spin coated with a solution of 50 wt% of NMP and 50 wt% of acetic anhydride to cap any unprotected amines remaining in any part of the wafer which have not been coupled with the next amino acid in the layer. The wafer is stripped in acetone and isopropyl alcohol (BDH Chemicals) to remove any resist present on the surface after each step. The whole process is repeated for each individual layer of amino acid designed to be coupled to complete the synthesis of all peptides designed using the reticles. The method used to verify the purity level of the synthesized peptide and the details of fluorescein quality control are described in supporting information (S2 Text).
Side Chain Protection Removal
After the completion of peptide synthesis, the side group protection present for some amino acids needs to be removed to enable biological activity of the peptide. Side chain Protection Removal cocktail is prepared by mixing 95 weight % Trifluoroacetic Acid [TFA] (Sigma Aldrich) and 5 weight % DI Water. Wafers are reacted with side chain protection removal cocktail for 90mins. This is followed by washing the chips successively with TFA (5mins), isopropyl alcohol (5mins), NMP (5mins), neutralize with 5 wt% of Ν,Ν-Diisopropylethylamine (Alfa Aesar) in NMP (5mins) followed by washing the wafer successively with NMP (5mins) and isopropyl alcohol (5mins).
Peptide Array—Gliadin and modified gliadin Synthesis
We constructed a library of gliadin peptides by building each 12-mer-long peptide with a lateral shift of 2 amino acids of α, β, γ, and Ω fractions of gliadin (Fig 3A). Moreover, we also established a library of modified gliadin peptides with deamidation sites incorporated into the gliadin sequences taken from the aforementioned library of gliadin peptides. In synthesizing the peptides for the library of modified sequences, glutamic acid (E) was inserted in place of glutamine (Q) reflecting the deamidation process and this was done 1, 2, and 3 at a time (Fig 3B). For example, for the original sequence, FLQQPQQPSP, the following sequences were synthesized: FLEQPQQPSP, FLQEPQQPSP, FLEEPQQPSP, FLEEPEQPSP, FLQQPQEPSP and so on (Fig 3B). Original sequences are termed as native gliadin sequences and those sequences in which glutamic acid are incorporated in place of glutamine, are referred to as modified gliadin peptides. These gliadin peptide sequences from the gliadin peptides library were all synthesized using a proprietary combinatorial photolithographic process which was explained in Fig 2 as described above. The amino acid sequences of α, β, γ, and Ω gliadin used for this process are shown in S1 Table.
Peptide Array Analyzer
To determine the immune-reactive peptide sets, immunologic binding assays with clinically proven celiac positive samples, which were from the exploratory cohort, were performed on an array that included the overlapping peptide sequences of α, β, γ, and Ω gliadin. Using the fluorescence microarray scanner, immunoassay binding activity was scanned. The scanned immunoassay binding data were analyzed to differentiate the substantial levels of binding, which referred to the mean signal binding intensity of the subsequences. After the completion of bioassay, fluorescent binding intensities obtained are converted to antibody-binding units after normalizing the values for each peptide. Peptide values are normalized using a least variant set method of normalization algorithm. Further analysis for determining the sensitivity and specificity of each peptide is done using the receiver operating characteristic (ROC) curve. Threshold value for the ROC curve for each peptide is determined by choosing the value which has the highest sensitivity and specificity.
Overall sensitivity and specificity are calculated as follows. For a given specificity range, a sample is considered to be positive if any one of the peptides belonging in the specificity set has antibody normalized units greater than twice the maximum control sample antibody normalized units, which are calculated based on each specificity set.
Results
Algorithm to Determine B-cell Epitopes
Fig 4 shows an algorithm to determine B-cell epitopes from native and modified gliadin-derived peptides (MDPs, substitution of glutamine with glutamic acid). The 110K Ver2.0 (Vibrant Sciences), a peptide microarray consisting of 110,000 overlapping peptides (12-mer sequences) that represent gliadins and MGPs in duplicates (Fig 3A), was synthesized and picked and placed onto 96 pillar plates. Using this peptide microarray, 188 serum samples from a set consisting of 90 CD patients and 98 controls were tested for IgG and IgA reactivity to synthesized gliadin peptides to determine the key set of sequences (3-mer peptides) with the highest occurrences among celiac samples (Fig 5). First, each 12-mer sequence on the peptide microarray was assessed for binding by sera from celiac positive individuals. Within the set of all 12-mer sequences that showed weakly or strongly positive binding signals to sera from celiac patients, the most frequently occurring subsequences (3-mer) were determined using a computer program. Fig 5 shows the nine most frequently occurring 3-mer sequences, relative to IgA (Fig 5A) or IgG (Fig 5B) isotype. A matrix table (Fig 5) shows the percentage of occurrence of these sequences in a specific order. After identifying the most informative, frequent 3-mer subsequences, these 3-mer peptides were paired into 6-mers in forward and reverse combinations and then in situ synthesized into the second phase of arrays. Forward combination refers to the peptides with informative subsequence at the beginning of the sequence preceding a random subsequence. Reverse combination refers to sequences designed by having the random portion at the beginning followed by the informative subsequence. For example: QPFQPEAGLTHG is forward combination sequence whereas AGLTHGQPFQPE is a reverse combination sequence-thick letters designate the informative sequences. These highly reactive sequences could then be synthesized with learning from the first library; this set is continually evolving as more samples are run. Interestingly, reversing the sequences substantially impairs the recognition (S2 Table). This suggests that antibody recognition of epitopes of DGPs in CD is highly sequence-specific and only a few sequences are recognized across the entire spectrum of patients with CD. However, we cannot exclude the possibility that low reactivity in reversed sequences may be related to sterical hindrance imposed by peptide anchoring to the chip. Finally, 2 distinct consensus gliadin peptide sets (#1 and #2, S3 Table) were identified for discriminating patients with CD from controls in the cohort; peptide set 1 (IgG) exhibited 80% (95% CI, 71–87) sensitivity and 85% (95% CI, 76–91) specificity, and peptide set 2 (IgA) exhibited 86% (95% CI, 77–91) sensitivity and 89% (95% CI, 82–94) specificity. Table 2 shows the detailed discriminant power of these identified peptide sets for the diagnosis of CD in the exploratory cohort.
Table 2. Discriminant Power of Identified Peptide Sets (Continuous Gliadin Sequences) for the Diagnosis of CD in the Training Cohort.
Peptide Set | Celiac disease* N = 90 | Controls N = 98 | Total (n) |
---|---|---|---|
Peptide Set #1 (IgG) | |||
Positive | 72 | 15 | 87 |
Negative | 18 | 83 | 101 |
Peptide Set #2 (IgA) | |||
Positive | 77 | 11 | 88 |
Negative | 13 | 87 | 100 |
*Celiac Disease was defined by the current standard diagnosis of CD, composed of CD serology and duodenal biopsy.
Determination of Novel Discontinuous B-cell Epitopes
To improve diagnostic accuracy for CD, we assembled a novel set of sequences by combining sequences with identified high frequency of 3-mer sequences in the first step and random 3-mer and 6-mer peptides to form peptides between 6 and 15 amino acids in length (Fig 4). Examples of discontinuous peptide sequences, which were combination of the frequent 3-mer sequences from DGP and randomly assigned peptides, are presented in S3 Fig. With the ROC curves for discriminating patients with CD from controls, which were constructed for each synthesized peptide, high sensitive and highly specific peptide sets were identified. To evaluate the accuracies of these selected peptide biomarkers for the diagnosis of CD, we used Random Forest,[17] a statistical algorithm that creates voting classes of decision-making trees to evaluate the significance of each marker and classify samples. We identified 2 distinct discontinuous gliadin sequence sets that, when combined, significantly improved the sensitivity (IgG, 97%; IgA, 99%) and specificity (IgG, 98%; IgA, 100%) (P < .001) for the diagnosis of CD, in contrast to the first sets of peptides of gliadin sequences or current standard CD serologic testing with enzyme-linked immunosorbent assay kits, and the sensitivity and specificity of these current standard CD serologic testing shown in Fig 6A are similar to other previous studies.[18] These 2 distinct peptide sets are shown in S3 Table. The cross-validated area under the curve of a ROC curve using modified sequences, which glutamic acid was substituted for glutamine, for predicting CD was 0.99 (Fig 6B). Synthesis of these two distinct peptide sets of sequences was done on a silicon-based peptide array platform to confirm the discriminative power in another CD cohort.
Confirmation of the Novel B-cell Epitopes
To confirm the discriminative power of the novel discontinuous peptides from the exploratory cohort, we assayed sera from a population cohort of 1,896 persons in a blinded test. This cohort comprised 306 persons who were seropositive to CD and 1,590 controls. “Seropositive to CD” was defined as positivity for both anti–tissue transglutaminase IgA and anti-endomysial antibodies, which together have a high predictive value for biopsy-proven CD[19, 20]; assays of these antibodies are the current standard serologic tests for CD. Two novel synthetic peptides sets comprising discontinuous gliadin sequences showed a high accuracy for distinguishing CD cases from controls, achieving 100% agreement for the positive CD cases (Fig 7A and 7B). More interestingly, CD cases could be separated into a lower- or a higher-reactivity group on the basis of antibody-binding intensity (Fig 7C); the sera of all 33 patients who subsequently had clinically diagnosed CD exhibited higher-intensity binding and belonged to a higher-reactivity group. Further, to evaluate the correlation between duodenal pathologic findings of CD and immune reactivity to the identified peptide sets, we used the sera of 48 biopsy-proven CD cases and 33 CD cases that were subsequently diagnosed by duodenal pathology during follow-up (of the 306 seropositive CD cases). None of the first synthesized peptide sets from gliadin sequences could categorize serum samples based on the Marsh Score for small-intestinal pathology; however, newly assembled peptide sets with discontinuous gliadin sequences could clearly distinguish between less severe duodenal lesions and Marsh stage 3 (Fig 8).
Discussion
In CD, some B-cell epitopes of gliadin are linear.[21, 22] It is well known that antibodies primarily recognize 3-dimensional structures as opposed to linear structures, such as peptides presented by MHC molecules on antigen presenting cells to T cells. Knowing as we do that the immune response typifying CD requires proteins from wheat and like grains, we have been able to use the discovery power of this novel ultra-throughput platform to systematically search linear continuous and discontinuous peptides derived from all of the proteins known to be immunogenic for CD. Here, using this powerful new method, we identified a set of novel epitopes, which are recognized by the circulating antibodies found in the sera of patients with CD. These novel peptides are derived from modified gliadin (substitution of glutamic acid for glutamine) and show high sensitivity and specificity for discriminating patients with CD from controls. These 9-mer to 15-mer sequences, which are different from the known 33-mer gliadin sequence,[23] represent novel and heretofore unidentified B-cell epitopes of gliadin. The identified peptides were subjected to a rigorous test of significance and predictive values by testing serum samples from a confirmatory community-based cohort. We found that the identified novel epitopes from gliadin have a high accuracy in distinguishing patients with CD from controls, showing 99% sensitivity and 100% specificity.
The biomarker discovery via the platform of highly efficient mass manufacturing of ultra-high-density peptide microarrays presented here provides an efficient method to determine novel epitopes through mapping of antigens and combining the immunopotent sequences with random peptides. Indeed, the silicon-based platform allows several million peptides to be synthesized in parallel and makes it possible to apply the known antigens with overlapping peptides on a single microarray. We have used peptide arrays based on 2.1 million 9-mer to 15-mer peptides, each overlapping with 3 or 6 amino acids, to cover the immunogenic proteins with very high density, maximizing our ability to identify informative peptides, and we showed the effectiveness and utility of this technology in identification of unknown but novel epitopes that are recognized by patients with autoimmune disease. This advance will allow for the development of more precise diagnostic tests that can be incorporated into panels of testing for autoimmune diseases, including CD. Moreover, we have also evaluated the contribution of the individual amino acids of the antigen for antibody binding by designing microarrays of peptides containing lateral shifts of 1 amino acid, achieving higher mapping resolution for the target antigen.
All previous photolithography-based microarray in situ synthesis methods [5, 24–26] are based on individually addressable de-protection steps and then coupling of monomers to those selective de-protected sites. Despite advances in peptide microarray technology, specifically using photolithography on silicon chips to selectively de-protect amino acids that follow generalized activation, peptide microarrays are still challenging because of low yields, less fidelity, and time-consuming production methods. In contrast, the novel method described here involves generalized de-protection with selective activation; similar to the protein synthesis process that occurs in nature, in which generalized de-protection is followed by selective activation. This provides 2 major advantages: 1) a far-higher fidelity of peptide synthesis, and 2) a greatly reduced time requirement for each step. This can also permit a much higher number of steps, as many as 400, in the synthesis of the peptide array, resulting in a very low loss of yield. Prior methods, which work on selective de-protection followed by generalized activation, have a lower fidelity over time and lead to much higher loss of yield and less accuracy in the production of peptides. It is this combination of high fidelity and much shorter production time that results in a much higher yield and the ability to generate a large number of chips quite inexpensively with the very high fidelity required for biomarker discovery and ultimately for high-throughput diagnostic testing. Moreover, we developed the software algorithms with an evolutionary computational approach that is used to predict and then manufacture the appropriate matrices of combinations of peptide sequences. This highly efficient multi-step process combines off-the-shelf software (described in the Materials and Methods section) and a proprietary algorithm. Our method uses the state-of-the-art 248-nm semiconductor lithography tools on a proven 300-mm silicon wafer platform. Our very high microarray density enables not only the molecular diversity needed for biomarker discovery but also large-scale biomarker validation. In addition, this method is well suited for mass manufacturing for routine diagnostics, since the chip size can scale down to 0.5X 0.5 mm2 to fit any diagnostics well plate format (eg, 96, 384, 1396). This also enables smaller samples to be used for routine diagnostics.
In summary, because the prevalence of CD is increasing, the development of high-fidelity diagnostic tests with a high degree of accuracy that can be undertaken on a large scale will be an important addition to the diagnostic armamentarium for CD and potentially other immune diseases. Such a test will be important not only for clinical care but also for understanding the pathogenesis of disease. The relative noninvasiveness, broad availability, and versatility of the high-throughput peptide microarrays make this technology well suited for incorporation into routine health care and also provide a promising new tool for biomarker discovery.
Supporting Information
Acknowledgments
We thank Deborah I. Frank for her assistance in the preparation of the manuscript.
Data Availability
All relevant data are within the paper and its Supporting Information files.
Funding Statement
JAM and RSC were supported by the Mayo Foundation. Vibrant Sciences LLC provided support in the form of salaries for authors JR, VJ, KB, TW, HKK and KK, but did not have any additional role in the study design, data collection and analysis, decision to publish, or preparation of the manuscript. The specific roles of these authors are articulated in the ‘author contributions’ section.
References
- 1.Kijanka G, Murphy D. Protein arrays as tools for serum autoantibody marker discovery in cancer. J Proteomics. 2009;72: 936–44. 10.1016/j.jprot.2009.02.006 [DOI] [PubMed] [Google Scholar]
- 2.Ballew JT, Murray JA, Collin P, Maki M, Kagnoff MF, Kaukinen K, et al. Antibody biomarker discovery through in vitro directed evolution of consensus recognition epitopes. Proc Natl Acad Sci U S A. 2013;110: 19330–5. 10.1073/pnas.1314792110 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 3.Lewis JD. The utility of biomarkers in the diagnosis and therapy of inflammatory bowel disease. Gastroenterology. 2011;140: 1817–26 e2. 10.1053/j.gastro.2010.11.058 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 4.Solier C, Langen H. Antibody-based proteomics and biomarker research—current status and limitations. Proteomics. 2014;14: 774–83. 10.1002/pmic.201300334 [DOI] [PubMed] [Google Scholar]
- 5.Price JV, Tangsombatvisit S, Xu G, Yu J, Levy D, Baechler EC, et al. On silico peptide microarrays for high-resolution mapping of antibody epitopes and diverse protein-protein interactions. Nat Med. 2012;18: 1434–40. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 6.Beyer M, Nesterov A, Block I, Konig K, Felgenhauer T, Fernandez S, et al. Combinatorial synthesis of peptide arrays onto a microchip. Science. 2007;318: 1888 [DOI] [PubMed] [Google Scholar]
- 7.Dam CE, Houen G, Hansen PR, Trier NH. Identification and fine mapping of a linear B cell epitope of human vimentin. Scand J Clin Lab Invest. 2014;74: 506–14. 10.3109/00365513.2014.908474 [DOI] [PubMed] [Google Scholar]
- 8.Singh-Gasson S, Green RD, Yue Y, Nelson C, Blattner F, Sussman MR, et al. Maskless fabrication of light-directed oligonucleotide microarrays using a digital micromirror array. Nat Biotechnol. 1999;17: 974–8. [DOI] [PubMed] [Google Scholar]
- 9.Buus S, Rockberg J, Forsstrom B, Nilsson P, Uhlen M, Schafer-Nielsen C. High-resolution mapping of linear antibody epitopes using ultrahigh-density peptide microarrays. Mol Cell Proteomics. 2012;11: 1790–800. 10.1074/mcp.M112.020800 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 10.Rubio-Tapia A, Hill ID, Kelly CP, Calderwood AH, Murray JA. ACG clinical guidelines: diagnosis and management of celiac disease. Am J Gastroenterol. 2013;108: 656–76; quiz 77. 10.1038/ajg.2013.79 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 11.Norris JM, Barriga K, Hoffenberg EJ, Taki I, Miao D, Haas JE, et al. Risk of celiac disease autoimmunity and timing of gluten introduction in the diet of infants at increased risk of disease. Jama. 2005;293: 2343–51. [DOI] [PubMed] [Google Scholar]
- 12.Osorio C, Wen N, Gemini R, Zemetra R, von Wettstein D, Rustgi S. Targeted modification of wheat grain protein to reduce the content of celiac causing epitopes. Funct Integr Genomics. 2012;12: 417–38. 10.1007/s10142-012-0287-y [DOI] [PubMed] [Google Scholar]
- 13.Molberg O, Kett K, Scott H, Thorsby E, Sollid LM, Lundin KE. Gliadin specific, HLA DQ2-restricted T cells are commonly found in small intestinal biopsies from coeliac disease patients, but not from controls. Scand J Immunol. 1997;46: 103–8. [PubMed] [Google Scholar]
- 14.Sollid LM, Qiao SW, Anderson RP, Gianfrani C, Koning F. Nomenclature and listing of celiac disease relevant gluten T-cell epitopes restricted by HLA-DQ molecules. Immunogenetics. 2012;64: 455–60. 10.1007/s00251-012-0599-z [DOI] [PMC free article] [PubMed] [Google Scholar]
- 15.Sollid LM, Jabri B. Triggers and drivers of autoimmunity: lessons from coeliac disease. Nat Rev Immunol. 2013;13: 294–302. 10.1038/nri3407 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 16.Rubio-Tapia A, Kyle RA, Kaplan EL, Johnson DR, Page W, Erdtmann F, et al. Increased prevalence and mortality in undiagnosed celiac disease. Gastroenterology. 2009;137: 88–93. 10.1053/j.gastro.2009.03.059 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 17.Breiman L. Random Forests. Machine Learning. 2001;45: 5–32. [Google Scholar]
- 18.Clinical utility of serologic testing for celiac disease in ontario: an evidence-based analysis. Ont Health Technol Assess Ser. 2010;10: 1–111. [PMC free article] [PubMed] [Google Scholar]
- 19.Walker MM, Murray JA, Ronkainen J, Aro P, Storskrubb T, D'Amato M, et al. Detection of celiac disease and lymphocytic enteropathy by parallel serology and histopathology in a population-based study. Gastroenterology. 2010;139: 112–9. 10.1053/j.gastro.2010.04.007 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 20.Katz KD, Rashtak S, Lahr BD, Melton LJ 3rd, Krause PK, Maggi K, et al. Screening for celiac disease in a North American population: sequential serology and gastrointestinal symptoms. Am J Gastroenterol. 2011;106: 1333–9. 10.1038/ajg.2011.21 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 21.Osman AA, Gunnel T, Dietl A, Uhlig HH, Amin M, Fleckenstein B, et al. B cell epitopes of gliadin. Clin Exp Immunol. 2000;121: 248–54. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 22.ten Dam M, Van De Wal Y, Mearin ML, Kooy Y, Pena S, Drijfhout JW, et al. Anti-alpha-gliadin antibodies (AGA) in the serum of coeliac children and controls recognize an identical collection of linear epitopes of alpha-gliadin. Clin Exp Immunol. 1998;114: 189–95. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 23.Aleanzi M, Demonte AM, Esper C, Garcilazo S, Waggener M. Celiac disease: antibody recognition against native and selectively deamidated gliadin peptides. Clin Chem. 2001;47: 2023–8. [PubMed] [Google Scholar]
- 24.Fodor SP, Read JL, Pirrung MC, Stryer L, Lu AT, Solas D. Light-directed, spatially addressable parallel chemical synthesis. Science. 1991;251: 767–73. [DOI] [PubMed] [Google Scholar]
- 25.Gao X, Zhou X, Gulari E. Light directed massively parallel on-chip synthesis of peptide arrays with t-Boc chemistry. Proteomics. 2003;3: 2135–41. [DOI] [PubMed] [Google Scholar]
- 26.Pawloski AR, McGall G, Kuimelis RG, Baron D, Cuppoletti A, Ciccolella P, et al. Photolithographic synthesis of high-density DNA probe arrays: Challenges and opportunities. J Vac Sci Technol. 2007;B 25: 2537–46. [Google Scholar]
- 27.Szekely GJ, Rizo ML. Hierarchical clustering via joint between-within distances: extending Ward's minimum variance method. Journal of Classification. 2005;22: 151–83. [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Supplementary Materials
Data Availability Statement
All relevant data are within the paper and its Supporting Information files.