Abstract
In a previous issue of the World Journal of Gastroenterology, we have read the article by Li et al with great interest. We would like to thank the authors for their comprehensive contribution. However, it is our wish to make minor criticism over the present study from the perspective of methodology.
Keywords: Cirrhosis, Intercostal approach, Subcostal approach, Acoustic radiation force impulse, Liver fibrosis
Core tip: Hepatitis B virus infection is still one of the leading causes of cirrhosis and hepatocellular carcinoma. Liver biopsy is the gold standard method to assess the severity of liver fibrosis. However, there are several limitations of liver biopsy, including its invasive nature, small tissue sample size, and subjective grading system. Nowadays, noninvasive parameters have been utilized to evaluate liver histology. Additionally, ultrasound-based techniques, such as acoustic radiation force impulse have gained popularity in assessing liver fibrosis. Herein, we aimed to make a minor criticism regarding this study.
TO THE EDITOR
In a previous issue of the World Journal of Gastroenterology, we have read the article by Li et al[1] with great interest. We would like to thank the authors for their comprehensive contribution. However, it is our wish to make minor criticism over the present study from the perspective of methodology.
First, the measurements of Acoustic Radiation Force Impulse Imaging were performed in the right liver lobe through the intercostal space in present study[1]. Uslu et al[2] demonstrated that subcostal approach to the liver parenchyma was significantly superior to intercostal approach for the evaluation of liver stiffness in their study. As the pressure was transmitted better to liver parenchyma and the anterior abdominal wall, we are of the opinion that subcostal approach would give better results than intercostal approach in terms of determining the elasticity of the liver.
Second, it would have been better, if the authors had stated the length of the biopsy material and the number of the pieces of the portal tracts. Fibrosis is heterogeneously distributed throughout the liver, whereas a biopsy evaluates only 1/50000 of the total volume of the liver[3]. Additionally, if the biopsy material is not long enough, appropriate evaluation cannot be done. A length of at least 25 mm is required to assess the fibrosis score accurately[3]. It would have been better, if the authors had mentioned these conditions as limitations.
Further studies are needed to indicate the role of acoustic radiation force impulse imaging method in the management of liver fibrosis and cirrhosis in patients with chronic hepatitis C.
Footnotes
Conflict-of-interest statement: The author(s) indicate no potential conflicts of interest.
Open-Access: This article is an open-access article which was selected by an in-house editor and fully peer-reviewed by external reviewers. It is distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/
Peer-review started: November 26, 2015
First decision: December 22, 2015
Article in press: January 19, 2016
P- Reviewer: Grassi A, Wang K S- Editor: Qi Y L- Editor: A E- Editor: Liu SQ
References
- 1.Li SM, Li GX, Fu DM, Wang Y, Dang LQ. Liver fibrosis evaluation by ARFI and APRI in chronic hepatitis C. World J Gastroenterol. 2014;20:9528–9533. doi: 10.3748/wjg.v20.i28.9528. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 2.Uslu A, Batur A, Biyik M, Acikgozoglu S. Non-Invasive Evaluation of Liver Fibrosis Using Real-Time Elastography and Comparison of Intercostal and Subcostal Approaches. EJGM. 2015;12:109–113. [Google Scholar]
- 3.Frulio N, Trillaud H, Perez P, Asselineau J, Vandenhende M, Hessamfar M, Bonnet F, Maire F, Delaune J, De Ledinghen V, et al. Acoustic Radiation Force Impulse (ARFI) and Transient Elastography (TE) for evaluation of liver fibrosis in HIV-HCV co-infected patients. BMC Infect Dis. 2014;14:405. doi: 10.1186/1471-2334-14-405. [DOI] [PMC free article] [PubMed] [Google Scholar]