Abstract
The results of the measurement of vitamin B12 absorption by counting the radioactivity of 5 ml. serum obtained eight to 10 hours after the ingestion of an oral dose of 0·5 μg. vitamin B12 labelled with 0·5 μc. 57Co are compared with those obtained with the urinary excretion (Schilling) test. Inadequate urine collection and impaired renal function were responsible for low results in the Schilling test in four of the 12 control subjects, and an incomplete urine collection in four patients with pernicious anaemia could have led to doubt about the validity of the low result.
The measurement of serum radioactivity for 1,000 seconds gave conclusive results, the range in the patients with malabsorption of vitamin B12 being between 0 and 24 counts per minute, and in the control subjects and other patients with megaloblastic anaemia between 28 and 64 counts per minute. The highest serum radioactivity level in a patient with pernicious anaemia was 19 counts per minute.
Serum counting is simpler than the Schilling test and may be done alone when the patient's renal function is known to be poor, when urine collection is expected to be unreliable, or when the flushing dose of vitamin B12 should be avoided. Otherwise there is an advantage in doing both tests together for confirmation.
Full text
PDF



Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- BOOTH C. C., MOLLIN D. L. Plasma, tissue and urinary radioactivity after oral administration of 56Co-labelled vitamin B12. Br J Haematol. 1956 Jul;2(3):223–236. doi: 10.1111/j.1365-2141.1956.tb06695.x. [DOI] [PubMed] [Google Scholar]
- CALLENDER S. T., EVANS J. R. The urinary excretion of labelled vitamin B12. Clin Sci. 1955 May;14(2):295–302. [PubMed] [Google Scholar]
- DOSCHERHOLMEN A., HAGEN P. S. A dual mechanism of vitamin B12 plasma absorption. J Clin Invest. 1957 Nov;36(11):1551–1557. doi: 10.1172/JCI103552. [DOI] [PMC free article] [PubMed] [Google Scholar]
- GLASS G. B. J., BOYD L. J. Differentiation of macrocytic anemias and diagnosis of pernicious anemia and sprue in remission by accelerated measurement of hepatic uptake of radioactive Co60B12. Ann Intern Med. 1957 Aug;47(2):274–292. doi: 10.7326/0003-4819-47-2-274. [DOI] [PubMed] [Google Scholar]
- GOLDBERG S. R., TRIVEDI B. K., OLINER L. Radioactive vitamin B12 studies; experience with the urinary excretion test and the measurement of absorbed plasma radioactivity. J Lab Clin Med. 1957 Apr;49(4):583–589. [PubMed] [Google Scholar]
- HEINLE R. W., WELCH A. D., SCHARF V., MEACHAM G. C., PRUSOFF W. H. Studies of excretion (and absorption) of Co60 labeled vitamin B12 in pernicious anemia. Trans Assoc Am Physicians. 1952;65:214–222. [PubMed] [Google Scholar]
- MATTHEWS D. M. Observations on the estimation of serum vitamin B12 using Lactobacillus leichmannii. Clin Sci. 1962 Feb;22:101–111. [PubMed] [Google Scholar]
- MCCURDY P. R. THE DETECTION OF INTESTINAL ABSORPTION OF CO57 TAGGED VITAMIN B12 BY SERUM COUNTING. Ann Intern Med. 1965 Jan;62:97–102. doi: 10.7326/0003-4819-62-1-97. [DOI] [PubMed] [Google Scholar]
- NELP W. B., McAFEE J. G., WAGNER H. N., Jr Single measurement of plasma radioactive vitamin B12 as a test for pernicious anemia. J Lab Clin Med. 1963 Jan;61:158–165. [PubMed] [Google Scholar]
- SCHILLING R. F. Intrinsic factor studies II. The effect of gastric juice on the urinary excretion of radioactivity after the oral administration of radioactive vitamin B12. J Lab Clin Med. 1953 Dec;42(6):860–866. [PubMed] [Google Scholar]
- SPRAY G. H. MICROBIOLOGICAL ASSAY OF FOLIC ACID ACTIVITY IN HUMAN SERUM. J Clin Pathol. 1964 Nov;17:660–665. doi: 10.1136/jcp.17.6.660. [DOI] [PMC free article] [PubMed] [Google Scholar]