Abstract
Difficulties experienced by the newcomer to the fluorescent antibody staining method largely arise from two causes: (1) the many modifications in the procedure which have been suggested over the last decade; (2) the variability of the basic reagent, fluorescent conjugate, in terms of potency and specificity. The ensuing problem of non-reproducibility is clearly an important factor for clinical laboratories now faced with increasing demands for routine tests involving immunofluorescence. In this paper a simple approach to standardization is described which, if adopted, would lead to a more efficient use of the method.
Full text
PDF



Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Beck J. S., Paterson J. C. Nuclear antigens in normal and leukaemic leucocytes: a histochemical study using human auto-immune antinuclear antibodies. J Pathol Bacteriol. 1965 Oct;90(2):567–578. doi: 10.1002/path.1700900225. [DOI] [PubMed] [Google Scholar]
- Beutner E. H., Holborow E. J., Johnson G. D. A new fluorescent antibody method: mixed antiglobulin immunofluorescence or labelled antigen indirect immunofluorescence staining. Nature. 1965 Oct 23;208(5008):353–355. doi: 10.1038/208353a0. [DOI] [PubMed] [Google Scholar]
- Brighton W. D. Assay of materials used in immunofluorescence techniques. J Clin Pathol. 1966 Sep;19(5):456–460. doi: 10.1136/jcp.19.5.456. [DOI] [PMC free article] [PubMed] [Google Scholar]
- CLARK H. F., SHEPARD C. C. A DIALYSIS TECHNIQUE FOR PREPARING FLUORESCENT ANTIBODY. Virology. 1963 Aug;20:642–644. doi: 10.1016/0042-6822(63)90292-7. [DOI] [PubMed] [Google Scholar]
- COONS A. H., KAPLAN M. H. Localization of antigen in tissue cells; improvements in a method for the detection of antigen by means of fluorescent antibody. J Exp Med. 1950 Jan 1;91(1):1–13. doi: 10.1084/jem.91.1.1. [DOI] [PMC free article] [PubMed] [Google Scholar]
- GOLDSTEIN G., SLIZYS I. S., CHASE M. W. Studies on fluorescent antibody staining. I. Non-specific fluorescence with fluorescein-coupled sheep anti-rabbit globulins. J Exp Med. 1961 Jul 1;114:89–110. doi: 10.1084/jem.114.1.89. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Goudie R. B., Horne C. H., Wilkinson P. C. A simple method for producing antibody specific to a single selected diffusible antigen. Lancet. 1966 Dec 3;2(7475):1224–1226. doi: 10.1016/s0140-6736(66)92305-1. [DOI] [PubMed] [Google Scholar]
- HOLBOROW E. J., BROWN P. C., ROITT I. M., DONIACH D. Cytoplasmic localization of "complement-fixing" auto-antigen in human thyroid epithelium. Br J Exp Pathol. 1959 Dec;40:583–588. [PMC free article] [PubMed] [Google Scholar]
- MCKINNEY R. M., SPILLANE J. T., PEARCE G. W. DETERMINATION OF PURITY OF FLUORESCEIN ISOTHIOCYANATES. Anal Biochem. 1964 Jan;7:74–86. doi: 10.1016/0003-2697(64)90121-6. [DOI] [PubMed] [Google Scholar]