. 2016 Jan 1;22(1):63–69. doi: 10.1089/tmj.2015.0026

Body-Worn Sensors in Parkinson's Disease: Evaluating Their Acceptability to Patients

James M Fisher 1,, Nils Y Hammerla 2, Lynn Rochester 3, Peter Andras 4, Richard W Walker 1
PMCID: PMC4739122  PMID: 26186307

Abstract

Background: Remote monitoring of symptoms in Parkinson's disease (PD) using body-worn sensors would assist treatment decisions and evaluation of new treatments. To date, a rigorous, systematic evaluation of the acceptability of body-worn sensors in PD has not been undertaken. Materials and Methods: Thirty-four participants wore bilateral wrist-worn sensors for 4 h in a research facility and then for 1 week at home. Participants' experiences of wearing the sensors were evaluated using a Likert-style questionnaire after each phase. Qualitative data were collected through free-text responses. Differences in responses between phases were assessed by using the Wilcoxon rank-sum test. Content analysis of qualitative data was undertaken. “Non–wear time” was estimated via analysis of accelerometer data for periods when sensors were stationary. Results: After prolonged wearing there was a negative shift in participants' views on the comfort of the sensor; problems with the sensor's strap were highlighted. However, accelerometer data demonstrated high patient concordance with wearing of the sensors. There was no evidence that participants were less likely to wear the sensors in public. Most participants preferred wearing the sensors to completing symptom diaries. Conclusions: The finding that participants were not less likely to wear the sensors in public provides reassurance regarding the ecological validity of the data captured. The validity of our findings was strengthened by “triangulation” of data sources, enabling patients to express their agenda and repeated assessment after prolonged wearing. Long-term monitoring with wrist-worn sensors is acceptable to this cohort of PD patients. Evaluation of the wearer's experience is critical to the development of remote monitoring technology.

Key words: : Parkinson's disease, body-worn sensors, home monitoring

Introduction

The motor symptoms of Parkinson's disease (PD) include tremor, rigidity, and bradykinesia. With prolonged levodopa therapy, motor complications such as dyskinesia (additional, involuntary movements) may develop.1 The fluctuations seen in PD render quantification of symptoms challenging. Current gold-standard assessment methods include clinical rating scales2 and patient-completed symptom diaries, both of which are inherently subjective.3–5

Body-worn accelerometers have shown great promise as an objective measure of PD symptoms. Accurate detection of tremor,6 bradykinesia,7 and dyskinesia8 has previously been demonstrated, and accelerometers have been used for prolonged periods of remote symptom monitoring.9 Remote monitoring of patients' symptoms may enable more informed treatment decisions to be made, and the field has been identified as a key research area for the PD community.10 These methods may also yield data for use as an outcome measure for evaluation of new treatments.11 It is recognized that adoption of remote monitoring technology is dependent on perceptions of the user,12 yet a recent review article highlighting the growing interest of such technology in PD made no reference to any work evaluating the acceptability of such sensors to the wearers.13

No previous work has formally evaluated whether participants are truly concordant with the wearing of such sensors. Establishing the acceptability of long-term use of body-worn sensors in the home is therefore essential if remote monitoring technology is to be successfully implemented. We therefore aimed to evaluate the acceptability of wrist-worn sensors in a PD population following assessment after both brief and prolonged periods of wearing.

Materials and Methods

Ethical Approval

This study underwent full ethical review and was given a favourable ethical opinion by County Durham and Tees Valley Research Ethics Committee. This study was therefore performed in accordance with the ethical standards laid down in the 1964 Declaration of Helsinki and its later amendments.

Subjects and Recruitment

Thirty-four subjects were recruited, all of whom provided informed written consent. This study forms part of research exploring the use of accelerometers to assess upper limb motor symptoms in PD, the analysis of which is ongoing. Patients from the Northumbria PD service who fulfilled the following inclusion criteria were recruited: >18 years of age, diagnosis of idiopathic PD (United Kingdom Brain Bank Criteria14), stages I–IV of Hoehn and Yahr,15 not significantly cognitively impaired (Mini-Mental State Examination16 of >24), and taking immediate-release levodopa medication.

Body-Worn Sensor

The sensor (AX3 data logger; Axivity, Newcastle upon Tyne, United Kingdom)17 is a waterproof triaxial accelerometer, which was attached by an adjustable Velcro® (Velcro Industries B.V., Onbekend, The Netherlands) strap (overall weight, 35 g). It allows continuous sensing for up to 12 days without the need for recharging. Participants wore a sensor on each wrist (Fig. 1) in two different study phases.

Fig. 1.

Fig. 1.

The wrist-worn sensors used.

Phase 1

Participants attended Newcastle University's Clinical Ageing Research Unit (CARU) and wore the sensors continuously for approximately 4 h while undergoing clinical assessments.

Phase 2

Participants wore the sensors continuously at home with no clinician input for 1 week, while also completing symptom diaries. Participants were briefed to wear the sensors continuously and to go about their daily activities as normal, but were advised to discontinue wearing them should they become burdensome. Despite the sensors being waterproof, participants were invited to remove the sensors during washing/bathing if they preferred to do so.

Outcome Measures

A questionnaire was developed to capture participants' opinions regarding the sensors. The questionnaire was piloted on a volunteer participant to ensure clarity and readability and adapted in response to feedback. The questionnaire included nine items (Table 1), and for each item participants indicated their level of agreement on a symmetrical 5-point Likert scale. The questionnaire also included a space for participants to provide free-text feedback about the sensors. The same questionnaire was administered on completion of both study phases and was returned to researchers in a prepaid envelope.

Table 1.

Frequency of Responses to Questionnaire After Clinical Ageing Research Unit and Home Phases

  FREQUENCY OF RESPONSE
ITEM STRONGLY AGREE AGREE NEITHER AGREE NOR DISAGREE DISAGREE STRONGLY DISAGREE
1. The sensor looks like it is well made.a
 CARU 13 21 0 0 0
 Home 4 28 1 0 1
2. The sensor is comfortable to wear.a
 CARU 12 21 1 0 0
 Home 3 25 3 3 0
3. The sensor feels heavy on my arm.
 CARU 0 0 3 19 12
 Home 0 1 4 15 14
4. Performing the assessments was made more difficult by wearing the sensor.
 CARU 0 0 0 17 16
 Homeb          
5. I would be happy to wear the sensor around the house.a
 CARU 15 18 1 0 0
 Home 9 23 1 1 0
6. I would rather keep a regular diary of my symptoms for a week than wear the sensor for a week.
 CARU 0 0 5 18 11
 Home 0 1 6 18 9
7. If the sensor was incorporated into a working wristwatch I would be more likely to wear it.
 CARU 4 16 5 8 1
 Home 5 13 7 6 2
8. The sensor is easy to take on and off.
 CARU 8 19 5 1 0
 Home 5 24 2 2 0
9. I would be happy to wear the sensor in public.
 CARU 10 23 1 0 0
 Home 7 22 3 2 0
a

Statistically significant difference in responses for Clinical Ageing Research Unit (CARU)–home (p<0.05).

b

Question excluded as not relevant to the home phase of the study.

The amount of time that the sensors were not worn during the home monitoring period was estimated by analysis of accelerometer data. Data were examined for minute-long periods for which no orientation change of the sensor was seen. If 10 or more such minutes occurred consecutively, then the full period was classified as time when the sensor was not being worn. To avoid inadvertent classification of sleep as periods where sensors were not worn, analysis of accelerometer data was restricted to waking hours (defined as 08:00–22:00 h).

Data Analysis

IBM-SPSS software (IBM, Armonk, NY) was used to collate responses and to produce descriptive statistics. Likert response categories were treated as ordinal data because the intervals between categories cannot be assumed to be of equal magnitude. Significant differences between participants' Phase 1 and 2 responses were assessed by using the Wilcoxon rank-sum test. Content analysis of free text responses was undertaken. All free-text responses provided were transcribed verbatim. A coding framework was developed to describe the content of the responses (by J.M.F.). Comments were categorized by overarching theme, sentiment (positive or negative), and study phase (CARU or home). An experienced qualitative researcher (Kate Greenwell) who had no prior involvement with this project also performed content analysis. The second researcher received transcripts of the free-text comments but was blinded to the content analysis performed by the first researcher. Thereafter, both researchers met to compare analyses and to explore alternate interpretations/coding strategies, a process recognized as improving rigor in content analysis.18 Consensus opinion was reached on the most appropriate content analysis themes from the data captured.

Results

Questionnaire: Quantitative Data

A total of 34 participants completed the questionnaire after both study phases. The mean age of the study cohort was 69 years (range, 50–86 years), and the average duration of PD was 10 years (range, 2–26 years). Mean Mini-Mental State Examination score was 28.6 (range, 26–30). All participants wore the sensors for the duration of Phase 1; 32 did so for the entirety of Phase 2. Two patients did not complete Phase 2: 1 withdrew after 5 days (unwell) and 1 after 4 days (discomfort wearing the sensor); however, both participants completed the Phase 2 questionnaire. Of note, 10 patients did decline participation in the study; none cited unwillingness to wear the sensors as their reason for nonparticipation.

Six hundred eight (99.3%) of a possible 612 responses to the questionnaire items from both phases were completed, with only four invalid responses (three blank, one dual-selection). The frequencies of responses to items for each phase are presented in Table 1.

Only one participant reported a preference for keeping a symptom diary as opposed to wearing the sensors; this was the participant who withdrew due to sensor discomfort. After completion of Phase 2, 32/34 (94.1%) participants agreed that they were willing to wear the sensors at home, and 29/34 (85.3%) participants agreed that they were willing to wear the sensors in public.

Analysis of participants' responses between study phases revealed a statistically significant (p<0.05) change (toward less agreement) in the responses to Items 1 (the sensor looks like it is well made), 2 (the sensor is comfortable to wear), and 5 (I would be happy to wear the sensor around the house). Table 2 displays the magnitude and frequency of change for these three items. On further examination it was evident that the majority of participants showed no change in their responses. For participants whose responses declined in agreement, it is evident that the majority did so only by one category, with more pronounced swings in opinion (change by two or more categories) being rare. A change in opinion of two or more categories was only expressed by 2/34 (5.9%) of participants to Item 1, 3/34 (8.8%%) to Item 2, and 2/34 (5.9%) to Item 5. There was no significant difference between the study phases for the responses to the remaining five items considered for both phases of the study.

Table 2.

Scale and Frequency of the Change in Response for Items Where a Significant Difference Was Detected

  FREQUENCY
CHANGE IN RESPONSE THE SENSOR LOOKS LIKE IT IS WELL MADE (ITEM 1) THE SENSOR IS COMFORTABLE TO WEAR (ITEM 2) I WOULD BE HAPPY TO WEAR THE SENSOR AROUND THE HOUSE (ITEM 5)
More positive
 +4 0 0 0
 +3 0 0 0
 +2 0 0 0
 +1 0 1 2
0 (no change) 24 19 24
More negative
 −1 8 11 6
 −2 1 2 2
 −3 1 1 0
 −4 0 0 0

For Items 1, 2, and 5, further analysis was undertaken following contraction of the 5-point Likert scale into a 3-point scale: the responses strongly agree and agree were combined to “agreement,” strongly disagree and disagree to “disagreement,” and neither agree nor disagree remained unchanged. Analysis using the 3-point scale found no statistically significant change in participants' responses between study phases for Items 1 and 5 (p=0.180 and 0.414 respectively). A statistically significant decrease (toward less agreement) in the responses to Item 2 was evident (p=0.023).

Questionnaire: Qualitative Data

Thirteen participants (38.2%) provided free-text feedback in the post-CARU questionnaire; 18 (52.9%) did so in the questionnaire completed after the home monitoring period. In total, 25 different participants (73.5%) provided free-text feedback on at least one occasion during the study.

Content analysis, performed as described above, revealed three overarching themes: “Appearance” (Table 3), “Usability” (Table 4), and “Comfort” (Table 5). “Appearance” was subdivided into “Physical properties” and “Wearing in public.” Both “Usability” and “Comfort” were subdivided according to sentiment (positive or negative).

Table 3.

Content Analysis: Appearance

CONTENT, PATIENT ID PHASE COMMENT
Physical properties
 GHRS Home “Would prefer it to be a little smaller and with watch face as keep thinking it was a watch I was wearing”
 UVTR Home “The only problem was that I kept looking to find the time!”
Wearing in public
 MZGE Home “Wore it for a week, did not cover it up”
 GHRS Home “I would not like to wear in warm summer months as more noticeable to people and questions”
 GHRS CARU “Happy to wear (in public) but would not like members of public questioning what it is for as illness is private”

CARU, Clinical Ageing Research Unit.

Table 4.

Content Analysis: Usability

CONTENT, PATIENT ID PHASE COMMENT
Positive
 MXRL Home “I had expected it to interfere with my everyday life but that did not happen”
 WDSJ CARU “Someone will do [put on/off] for me”
 MUCL CARU “The sensor was very easy to have on”
 MUCL Home “The sensor I found easy to wear”
 ATYY Home “The sensor is easy to take on and off”
Negative
 PQEP Home “Because I have small wrists the sensors were swinging around and it was difficult to keep them in the upright position. After a couple of hours I used some surgical tape to stick it down where the strap fastens underneath—they are in the same position after one week including daily showers
 GHRS Home “Found it restricts you wearing tight sleeves on clothes”
 MUCL Home “Felt a little nervous having a shower”
 WDSJ Home “The left, blue sensor did not always stay securely in position and so needed occasional readjustment”
 FRMQ Home “I removed them whilst having a bath/shower because they became soggy”
 FRMQ Home “For someone with a tremor they are a little awkward”
 BRCN Home “Maybe stronger pins in the sensor would help, one came out”
 NRWL Home “Sensor a little awkward to fasten the strap…when feeling off”

CARU, Clinical Ageing Research Unit.

Table 5.

Content Analysis: Comfort

CONTENT, PATIENT ID PHASE COMMENT
Positive
 CGLT CARU “It feels no different to wearing a watch”
 QXLL CARU “Feels comfortable, don't mind having it on”
 MXRL Home “Found the sensor quite comfortable to wear”
 QXZV Home “Very comfortable to wear - just like wearing a watch”
 MZGE Home “No problem. Forgot it was there”
 QXLL Home “No problems with sensor, almost forgot it was on”
Negative
 UGNK CARU “Strap would be more comfortable if leather”
 LAPC Home “Velcro slightly uncomfortable”
 FRMQ Home “The sensor is slightly scratchy especially when wearing a watch as well”
 ATYY Home “It is always on your skin, also, when it gets wet it is very uncomfortable to wear generally and I don't like it very much”
 GHRS Home “Comfortable to wear, however, after a week of constant wear feeling a little irritating”
 JKVJ Home “If strap were more comfortable would make wearing very easy”

CARU, Clinical Ageing Research Unit.

Accelerometer Data

The mean duration of “non–wear time” (time during home monitoring waking hours where the sensors were not worn) was 228.2 min (SD=385.3 min), equivalent to 32.6 min/day. The large SD value is in part explained by one participant who represents a clear outlier. This participant discontinued home monitoring after 4 days, citing sensor discomfort, and wore the sensors for only 40.3% of home monitoring waking hours. When this outlier was excluded, the mean duration of “non-wear” time was 159.7 min (SD=150.9 min), equivalent to 22.8 min/day (2.72% of waking hours).

Discussion

This is the first study to our knowledge to carry out a thorough, detailed evaluation of the acceptability of body-worn sensors in PD. Our research suggests that long-term monitoring with body-worn sensors is acceptable to PD patients—a critical finding—because patient nonconcordance with the wearing of a sensor renders even the most sensitive and accurate device virtually useless.

Strengths of the work include the tripartite approach to data collection (qualitative wearer data, quantitative wearer data, and accelerometer data). This approach enabled us to obtain more detailed insight into participants' experiences of wearing the sensors because participants were provided with an opportunity to voice their agenda.19 Evaluation revealed themes common to both qualitative and quantitative participant datasets and also allowed corroboration of acceptability through analysis of accelerometer “wear-time” data. This “triangulation” process between datasets helped strengthen the validity of our findings. A further strength is that acceptability was evaluated after both short and prolonged periods of wearing. After prolonged wearing participants were less likely to agree that the sensors were comfortable to wear. Qualitative data revealed that the main source of sensor discomfort related to the strap. Furthermore, some participants reported problems with ill-fitting straps that resulted in relative motion between the sensor and the body—the resulting extraneous signal artifact may have adversely affected the quality of data captured.20 As a consequence of these findings the strap material, as well as the method for adjusting the sizing of it, was modified for the latest iteration of the sensor.

Previous research in PD has invariably failed to consider the views of the wearer; van Someren et al.,21 for example, suggested that wearing a wrist-worn sensor for several weeks would be “no more uncomfortable than wearing a wrist-watch.” This is a gross oversimplification and fails to appreciate the psychology associated with the wearing of a medical device.

Despite a decline in patients' views on sensor comfort and their willingness to wear them at home, this did not translate into patients not wearing the sensors because concordance, as evidenced by the accelerometer-derived wear-time data, was high. On average (excluding an outlier), participants only removed the sensors for approximately 22 min/day—participants were invited to remove the sensors during washing/bathing, and this period of non–wear time may represent such activities. Lehoux22 suggested that user acceptance may also depend on the context in which a sensor is worn, with patients often more self-conscious outside their “private sphere.” Social embarrassment and the feeling that wearing such a product marked a person as “old” have been highlighted as a major factor affecting acceptability of body-worn sensors.23 Our findings suggest that long-term monitoring with body-worn sensors is acceptable to PD patients and that the vast majority of participants were willing to wear the sensor both at home and in public, a critical component of ensuring ecological validity of the recorded data.

The only detailed previous work on sensor acceptability in PD24 showed, in contrast to our findings, a large disparity between participants' willingness to wear sensors at home and in public (94% and 55% yes, respectively). If the wearing of a sensor results in modification of the wearer's behavior, then the ecological validity of the data collected is limited. Critically, Giuffrida et al.24 polled participants' views in the presence of researchers, in a research facility, and did so after participants had only worn the sensors for a short period. It is possible that these factors may have introduced bias, resulting in false reassurance about the sensors' acceptability. It is recognized that a degree of obtrusiveness is inevitable with even the most well-designed sensor, and this may be magnified by more prolonged monitoring periods.25 In our study, polling views after the period of prolonged monitoring did not reveal marked deterioration in the wearability of the sensor, as might be expected if the sensor was not user-friendly.25

It is well recognized that patient concordance with home diaries, the current gold standard for home monitoring in PD, can be poor and that entries are often not made contemporaneously.26 Our work revealed that participants overwhelmingly preferred wearing the sensor to completing a diary. Cognitive impairment is common in PD27 and may impact on a person's ability to accurately complete a home diary; consequently, such patients are frequently underrepresented in clinical trials. Body-worn sensors may in the future enable remote monitoring of patients who are unable to maintain symptom diaries. It is, however, acknowledged that the acceptability of sensors in this group is not yet established because cognitively impaired patients were not involved in this work.

A potential limitation of our work is that the study population may not be truly reflective of the wider PD population. Those engaging with such a research project may be more willing to wear such a sensor. We believe that this effect is likely to be minimal because the study inclusion criteria were broad, thus reflecting a spectrum of disease, and the study protocol was not particularly arduous. For those who opted not to participate in the study, none reported unwillingness to wear the sensors as their reason for nonparticipation. Second, this research used only wrist-worn sensors, and thus our conclusions may not be applicable to sensors worn elsewhere on the body; less conspicuous sensor placement may further improve acceptability.

This research has highlighted the central importance of patient acceptability to home-monitoring systems. A recent United Kingdom Department of Health mandate28 targeted increased availability of home monitoring of chronic long-term health conditions by 2017. In this respect, prolonged monitoring requires a sensor to be as unobtrusive and as wearable as possible to avoid declining patient concordance during the monitoring period.25 Our work has demonstrated the acceptability of the sensors used and has highlighted the need to consider patients' views when such systems are trialed. Further research might explore the acceptability of sensors worn in other body areas or modification of the wrist-worn sensor to include a functioning watch face, which may improve acceptability further.

Conclusions

  • • The wearer's perspective must be considered when body-worn technology is being developed and evaluated.

  • • Bilateral wrist-worn sensors were acceptable to our population of patients with PD, even after a period of prolonged wearing.

  • • There was no evidence that participants were less likely to wear the sensors in public, a key finding to support the ecological validity of the data captured.

  • • A tripartite approach to data collection allowed triangulation of data relating to the patient experience and has directly informed further development of the sensor.

Acknowledgments

We would like to acknowledge the help of all the participants in the trial. We would like to acknowledge the help of Kate Greenwell with the qualitative analysis in this work. This study was funded by the Northumbria Healthcare NHS Foundation Trust. L.R. is supported by the National Institute for Health Research (NIHR) Newcastle Biomedical Research Unit based at Newcastle upon Tyne Hospitals NHS Foundation Trust and Newcastle University. The research was also supported by NIHR Newcastle CRF Infrastructure funding.

Disclosure Statement

No competing financial interests exist.

References

  • 1.Rascol O, Brooks DJ, Korczyn AD, De Deyn PP, Clarke CE, Lang AE. A five-year study of the incidence of dyskinesia in patients with early Parkinson's disease who were treated with ropinirole or levodopa. N Engl J Med 2000;342:1484–1491 [DOI] [PubMed] [Google Scholar]
  • 2.Goetz CG, Tilley BC, Shaftman SR, Stebbins GT, Fahn S, Martinez-Martin P, et al. . Movement Disorder Society-sponsored revision of the Unified Parkinson's Disease Rating Scale (MDS-UPDRS): Scale presentation and clinimetric testing results. Move Disord 2008;23:2129–2170 [DOI] [PubMed] [Google Scholar]
  • 3.Post B, Merkus MP, de Bie RMA, de Haan RJ, Speelman JD. Unified Parkinson's Disease Rating Scale motor examination: Are ratings of nurses, residents in neurology, and movement disorders specialists interchangeable? Move Disord 2005;20:1577–1584 [DOI] [PubMed] [Google Scholar]
  • 4.Vitale C, Pellecchia MT, Grossi D, Fragassi N, Cuomo T, Di Miao L, et al. . Unawareness of dyskinesias in Parkinson's and Huntington's diseases. Neurol Sci 2001;22:105–106 [DOI] [PubMed] [Google Scholar]
  • 5.Reimer J, Grabowski M, Lindvall O, Hagell P. Use and interpretation of on/off diaries in Parkinson's disease. J Neurol Neurosurg Psychiatry 2004;75:396–400 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 6.Hoff JI, Wagemans EA, van Hilten BJ. Ambulatory objective assessment of tremor in Parkinson's disease. Clin Neuropharmacol 2001;24:280–283 [DOI] [PubMed] [Google Scholar]
  • 7.Cancela J, Pansera M, Arredondo MT, Estrada JJ, Pastorino M, Pastor-Sanz L, et al. . A comprehensive motor symptom monitoring and management system: The bradykinesia case. Conf Proc IEEE Eng Med Biol Soc 2010;2010:1008–1011 [DOI] [PubMed] [Google Scholar]
  • 8.Keijsers NLW, Horstink MWIM, Gielen SCAM. Automatic assessment of levodopa-induced dyskinesias in daily life by neural networks. Move Disord 2003;18:70–80 [DOI] [PubMed] [Google Scholar]
  • 9.Griffiths RI, Kotschet K, Arfon S, Xu ZM, Johnson W, Drago J, et al. . Automated assessment of bradykinesia and dyskinesia in Parkinson's disease. J Parkinsons Dis 2012;2:47–55 [DOI] [PubMed] [Google Scholar]
  • 10.Deane KHO, Flaherty H, Daley DJ, Pascoe R, Penhale B, Clarke V, et al. . Priority setting partnership to identify the top 10 research priorities for the management of Parkinson's disease. BMJ Open 2014;4(12):e006434. doi: 10.1136/bmjopen-2014-006434 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 11.Evans JR, Barker RA. Defining meaningful outcome measures in trials of disease-modifying therapies in Parkinson's disease. Expert Opin Pharmacother 2011;12:1249–1258 [DOI] [PubMed] [Google Scholar]
  • 12.Davis MM, Freeman M, Kaye J, Vuckovic N, Buckley DI. A systematic review of clinician and staff views on the acceptability of incorporating remote monitoring technology into primary care. Telemed J E Health 2014;20:428–438 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 13.Maetzler W, Domingos J, Srulijes K, Ferreira JJ, Bloem BR. Quantitative wearable sensors for objective assessment of Parkinson's disease. Move Disord 2013;28:1628–1637 [DOI] [PubMed] [Google Scholar]
  • 14.Gibb WR, Lees AJ. The relevance of the Lewy body to the pathogenesis of idiopathic Parkinson's disease. J Neurol Neurosurg Psychiatry 1988;51:745–752 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 15.Hoehn MM, Yahr MD. Parkinsonism: Onset, progression and mortality. Neurology 1967;17:427–442 [DOI] [PubMed] [Google Scholar]
  • 16.Folstein MF, Folstein SE. “Mini-Mental State.” A practical method for grading the cognitive state of patients for the clinician. J Psychiatr Res 1975;12:189–198 [DOI] [PubMed] [Google Scholar]
  • 17.Axivity. AX3 3 axis logging accelerometer: Data sheet 2013. Available at http://axivity.com/v2/products/AX3/AX3-1.7-Datasheet.pdf (last accessed December21, 2013)
  • 18.Barbour RS. Checklists for improving rigour in qualitative research: A case of the tail wagging the dog? BMJ 2001;322:1115–1117 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 19.O'Cathain A, Thomas K. “Any other comments?” Open questions on questionnaires—A bane or a bonus to research? BMC Med Res Methodol 2004;4:25. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 20.Yang C-C, Hsu Y-L. A review of accelerometry-based wearable motion detectors for physical activity monitoring. Sensors 2010;10:7772–7788 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 21.van Someren EJW, van Gool WA, Vonk BFM, Mirmiran M, Speelman JD, Bosch DA, et al. . Ambulatory monitoring of tremor and other movements before and after thalamotomy: A new quantitative technique. J Neurol Sci 1993;117:16–23 [DOI] [PubMed] [Google Scholar]
  • 22.Lehoux P. Patients' perspectives on high-tech home care: A qualitative inquiry into the user-friendliness of four technologies. BMC Health Serv Res 2004;4:28. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 23.Peeters PHF. Design criteria for an automatic safety-alarm system for elderly. Technol Health Care 2000;8:81–91 [PubMed] [Google Scholar]
  • 24.Giuffrida JP, Riley DE, Maddux BN, Heldmann DA. Clinically deployable kinesia technology for automated tremor assessment. Move Disord 2009;24:723–730 [DOI] [PubMed] [Google Scholar]
  • 25.Bonato P. Advances in wearable technology and its medical applications. Conf Proc IEEE Eng Med Biol Soc 2010;2010:2021–2024 [DOI] [PubMed] [Google Scholar]
  • 26.Stone AA, Shiffman S, Schwartz JE, Broderick JE, Hufford MR. Patient non-compliance with paper diaries. BMJ 2002;324:1193–1194 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 27.Weintraub D, Burn DJ. Parkinson's disease: The quintessential neuropsychiatric disorder. Move Disord 2011;26:1022–1031 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 28.Department of Health. The Mandate: A mandate from the Government to the NHS Commissioning Board: April 2013 to March 2015. London: Williams Lea, 2012 [Google Scholar]

Articles from Telemedicine Journal and e-Health are provided here courtesy of Mary Ann Liebert, Inc.