Skip to main content

Some NLM-NCBI services and products are experiencing heavy traffic, which may affect performance and availability. We apologize for the inconvenience and appreciate your patience. For assistance, please contact our Help Desk at info@ncbi.nlm.nih.gov.

PLOS ONE logoLink to PLOS ONE
. 2016 Feb 3;11(2):e0148188. doi: 10.1371/journal.pone.0148188

Systematic Review of Inhaled Bronchodilator and Corticosteroid Therapies in Infants with Bronchopulmonary Dysplasia: Implications and Future Directions

Brian J Clouse 1,*, Sudarshan R Jadcherla 1,2,3, Jonathan L Slaughter 1,2,3
Editor: Josué Sznitman4
PMCID: PMC4740433  PMID: 26840339

Abstract

Background

There is much debate surrounding the use of inhaled bronchodilators and corticosteroids for infants with bronchopulmonary dysplasia (BPD).

Objective

The objective of this systematic review was to identify strengths and knowledge gaps in the literature regarding inhaled therapies in BPD and guide future research to improve long-termoutcomes.

Methods

The databases of Academic Search Complete, CINAHL, PUBMED/MEDLINE, and Scopus were searched for studies that evaluated both acute and long-term clinical outcomes related to the delivery and therapeutic efficacy of inhaled beta-agonists, anticholinergics and corticosteroids in infants with developing and/or established BPD.

Results

Of 181 articles, 22 met inclusion criteria for review. Five evaluated beta-agonist therapies (n = 84, weighted gestational age (GA) of 27.1(26–30) weeks, weighted birth weight (BW) of 974(843–1310) grams, weighted post menstrual age (PMA) of 34.8(28–39) weeks, and weighted age of 53(15–86) days old at the time of evaluation). Fourteen evaluated inhaled corticosteroids (n = 2383, GA 26.2(26–29) weeks, weighted BW of 853(760–1114) grams, weighted PMA of 27.0(26–31) weeks, and weighted age of 6(0–45) days old at time of evaluation). Three evaluated combination therapies (n = 198, weighted GA of 27.8(27–29) weeks, weighted BW of 1057(898–1247) grams, weighted PMA of 30.7(29–45) weeks, and age 20(10–111) days old at time of evaluation).

Conclusion

Whether inhaled bronchodilators and inhaled corticosteroids improve long-term outcomes in BPD remains unclear. Literature regarding these therapies mostly addresses evolving BPD. There appears to be heterogeneity in treatment responses, and may be related to varying modes of administration. Further research is needed to evaluate inhaled therapies in infants with severe BPD. Such investigations should focus on appropriate definitions of disease and subject selection, timing of therapies, and new drugs, devices and delivery methods as compared to traditional methods across all modalities of respiratory support, in addition to the assessment of long-term outcomes of initial responders.

Introduction

Many pharmacological interventions are used to treat BPD in preterm infants with the aim of optimizing pulmonary function as well as reducing concomitant co-morbidities [14]. The chronic pulmonary insufficiency associated with BPD often has a deleterious effect on the normal development of multiple organ systems, making the overall illness difficult to manage [5, 6].

Inhaled medications such as beta-agonists, anticholinergics and corticosteroids (ICS) have been used to treat airway disease in infants with BPD. Beta-agonists and anticholinergics and have been shown to acutely improve pulmonary function. However, the prescription of such therapies remains highly variable due to insufficient evidence to support improved long-term outcomes [612]. Several heterogeneous factors such as disease severity, variation in response among subjects, differences in aerosol delivery methods, choice of therapeutic agents, dose prescribed or actual dose delivered to the targeted site could potentially affect the interpretation of clinical outcomes. The purpose of this critical review is to identify therapeutic effect-influencing factors among existing randomized control trials that assessed inhaled bronchodilator and corticosteroid use among infants with BPD, so as to guide future research protocols aimed to improve long-term outcomes.

Methods

Literature Search

The databases of Academic Search Complete, CINAHL, PUBMED/MEDLINE, and Scopus were searched using the Boolean phrase: ((bronchopulmonary dysplasia AND (inhaled bronchodilators OR inhaled beta agonists OR inhaled corticosteroids OR inhaled anticholinergics NOT nitric oxide))). The databases were searched from their earliest indexed dates to December 1, 2015. The reference lists of included manuscripts were reviewed in search of sources that may have been missed.

Selection Criteria

A search filter was applied to limit results to include studies of randomized controlled design. Two reviewers (BJC and JLS) independently appraised the literature. Completed studies with a purpose of assessing delivery, efficacy, and clinical outcomes of beta-agonists, anticholinergics and inhaled corticosteroids (ICS) in infants with developing and/or established BPD (as evident by chest radiograph [13] or current definition [14]) were selected for inclusion in this review.

Data Collection and Appraisal

The guidelines of the PRISMA Statement for presentation of systematic reviews were followed to report the findings of this systematic review (see S1 File) [15]. The Matrix Method was used to organize, extract, and appraise data compiled from included studies [16]. Specific data extracted included subject demographics, inhaled drug classifications, dosages, delivery methods, aerosol characteristics, outcome measures (short-term vs. long-term), and results. Short-term outcomes were defined as a subject’s response to a single treatment session, whereas long-term outcomes were defined a subject’s response to multiple treatment sessions.

The methodological quality of the data was appraised for potential biases. Details pertaining to randomization (listed method or unclear), allocation concealment (listed method or unclear), double blinding (yes, no, or unclear), power calculation (yes or no) and reporting of exact point statistical methods (yes or no) were collected. Each study [1738] was scored for three levels of potential bias (low, high, or unclear). A “no” answer in any category was scored as a high risk for potential bias, whereas one “unclear” with otherwise all “yes” answers was scored as an unclear risk of bias. In order to classified as a low risk of potential bias, all methods assessed had to be clear, the study had to be double blinded, a power calculation performed, and exact point statistics used.

Results

Database searches with the Boolean phrase (as described above) yielded 168 results. Thirteen additional studies were identified from the reference lists of select articles. A total of 181 articles were screened. After filtering to exclude studies of non-randomized controlled design, thirty-five articles remained. Thirteen articles were excluded during appraisal (4 duplicates, 3 did not focus on BPD, 3 did not evaluate inhaled medications, 2 were incomplete, and 1 evaluated inhaled medications other than bronchodilators, or ICS), leaving 22 articles included in the review (Fig 1). Characteristics of the 22 included studies [1738] can be found in Table 1. Quality assessment of the data revealed an overall high risk for potential bias in the included studies as shown in Table 2.

Fig 1. PRISMA Flow Diagram.

Fig 1

Flow diagram of the systematic review revealing the pathway to the included studies.

Table 1. Characteristics of Included Randomized Control Trials (n = 22).

First Author (year) Inclusion Criteria* n GA (wk) BW (g) Age (d) Inhaled Medication Delivery Device/Dose MDI Particle Size (MMAD) Resp. Support Outcome Type§ Outcome Measures Summary of Findings
Inhaled Beta-agonists
Fok[17] 1996 age>2wk, BPD, on resp. support during first wk of life 23 28 1097 82 salbutamol jet neb, 100μg/kg, MDI(CFC) 200μg 2.3μm mech. vent. & spont. breathing short-term gamma imaging aerosol deposition small and variable MDI delivery > jet neb.
Fok[18] 1998 GA<32 wk, BW<1500g, age>2wk, BPD on resp. support during first week of life 20 27 843 51 salbutamol MDI(CFC), ultrasonic neb., jet neb., 200μg 2.3μm mech. vent. short-term HR, TCCO2, TCO2, Crs, Rrs aerosol delivery order of efficiency: ultrasonic>MDI>jet neb.
Gappa[19] 1997 responsive to inhaled therapies or established BPD 13 27 903 69 salbutamol jet neb., 600μg, MDI(CFC) 200μg 2.3μm spont. breathing short-term CL,dyn, RL,dyn inhaled salbutamol improves lung mechanics with jet neb. & MDI being equally efficient
Pfenninger[20] 1993 BPD, on mech. vent. 8 30 1310 48 salbutamol MDI(CFC) 200μg, IV, 10μg/kg 2.3μm mech. vent. short-term HR, BP, CBG, TCO2, Crs, Rrs inhaled & IV salbutamol improves lung mechanics equally with comparable cardiac side effects
Rotschild[21] 1989 GA = preterm, BW<1500, BPD on mech. vent. 20 26 875 15 salbutamol jet neb., 2.5mg NA mech. vent. short-term HR, BP, PO2, PCO2, Crs, Rrs early bronchodilator therapy may be beneficial in preterm infants with BPD
Inhaled Corticosteroids
Bassler[22] 2015 GA ≥23 <28wk, age≤12h, on positive pressure 863 26 801 0 budesonide MDI(HFA), 800μg/d x 14d, then 400μg/d from 15d to 32 wk PMA 3.9μm mech. vent. & spont. breathing long-term death or BPD at 36wk PMA incidence of BPD was less in treatment group vs placebo, budesonide may increase mortality
Cole[23] 1999 GA<33wk, BW<1251g, age 3–14d on mech. vent. 253 26 801 6 beclometh. MDI(CFC), 1000μg/kg/d 4wk taper to 125μg/kg/d 3.5μm mech. vent. long-term BPD early ICS in infants at risk for BPD was associated with less subsequent systemic steroid use, bronchodilator use, & mech. vent. on DOL 28
Cole[24] 1999 GA<33wk, BW<1251g, age 3–14d. 148 26 838 27 beclometh. MDI(CFC), 1000μg/kg/d 4wk taper to 125μg/kg/d 3.5μm mech. vent. long-term plasma cortisol levels ICS was associated with mildly reduced plasma cortisol levels, no adrenal suppression on cosyntropin stimulation
Dimitriou[25] 1997 GA<32wk, on mech. vent. = 5d or suppl. O2 = 14d BW<1251g, age 3–14d. 40 27 834 27 budesonide MDI(CFC), 400μg/d 4.0μm mech. vent. & spont. breathing long-term duration of resp. support, Crs, BP, adverse events systemic steroids have a faster onset of action versus ICS
Dugas[26] 2005 GA<32wk, age 28–60d, BPD, on resp. support 32 27 961 45 fluticasone MDI(CFC), 250μg/d x 3wk, 125μg/d x 1wk|| 2.6μm mech. vent. & spont. breathing long-term duration of O2, survival with O2 fluticasone does not reduce O2 need in infants with moderate BPD
Fok[27] 1999 GA<32wk, BW<1500g, age = 1d, RDS, on mech. vent 53 28 987 1 fluticasone MDI(CFC), 1000μg/d x 2wk 2.6μm mech. vent long-term extubation at 7&14d, Crs, Rrs, death, BPD more cases versus controls extubated on DOL 14 & had increased Crs, no difference in need for systemic steroids or the development of BPD
Merz[28] 1999 GA = 25–32wk, BW = 750–1500g, age = 3d, on mech. vent. 23 29 1114 3 budesonide MDI(CFC), 1600μg/d x 10d or extubation 4.5μm mech. vent long-term duration of resp. support, BPD, inflammatory markers, endocrine funct. no outcome differences between cases & controls including side effects
Giep[29] 1996 BW<1500g, age≥2wk, RDS or evolving BPD, on mech. vent. 19 26 768 5 beclometh. MDI(CFC), 1mg/kg/d 3.5μm mech. vent long-term BP, HR, resp. support, cortisol levels, etc. inhaled beclometh. can be safely delivered to intubated neonates
Gupta[30] 2000 GA<33wk, BW≤ 1250g, age 3–14d, on mech. vent. 161 26 794 5 beclometh. MDI(CFC), 1000μg/kg/d 4wk taper to 125μg/kg/d 3.5μm mech. vent long-term tracheal aspirates IL-8, IL-1ra being a case was associated with decreased inflammation following 1 week of therapy, less systemic steroid use, & less incidence of BPD
Halliday[31] 2001 GA<30wk, age<72hr and/or>15d on mech. vent. 570 27 1007 2 budesonide MDI(CFC), 800μg/kg/d x 12d 4.5μm mech. vent. long-term death, O2 at 36wk PMA, duration of O2, adverse events inhaled budesonide may be safer but no clear evidence regarding effectiveness versus dexamethasone
Kovács[32] 1998 GA<30, BW≤1500g, age = 7d 60 26 764 7 budesonide jet neb. 1000μg/d x 18d NA mech. vent. long-term incidence of BPD ICS not as effective as systemic steroids & do not improve BPD outcomes
LaForce[33] 1993 BW<1500g, age = 14d, RDS or BPD on mech. vent. 13 ND ND 14 beclometh. jet neb. 150μg/d x 28d NA mech. vent. & spont. breathing long-term Crs, Rrs, tracheal aspirate, blood/urin/CSF cultures cases showed improved pulmonary mechanics following 3weeks of therapy
Rozycki[34] 2003 age = 14d at risk for BPD on mech. vent 61 26 760 14 beclometh. MDI(CFC), 3 dose ranges, 17–129μg/kg/d 3.5μm mech. vent. long-term extubation within 7d low dose ICS was less effective than systemic steroids to facilitate extubation
Suchomski[35] 2002 GA<30wk, BW≤1500g, age = 12–21d 78 26 844 17 beclometh. MDI(CFC), 2 dose levels 400 and 800μg/kg/d 3.5μm mech. vent. long-term changes in vent settings, duration of resp support, BPD, LOS, adverse events with delayed onset ICSs offer no advantage over systemic steroids and have similar risks
Combination Therapies
Denjean[36] 1998 GA<31wk, age = 10d, RDS, on mech. vent. 173 28 1050 10 salbutamol & beclometh. MDI(CFC), 1200μg/d & 1000μg/d taper over 8d 2.3μm & 3.5μm mech. vent. & spont. breathing long-term BPD or death no significant outcome differences among groups
Kao[37] 1989 BPD 15 29 1247 111 metaproterenol & atropine jet neb., 1mg/kg & 0.8mg/kg NA spont. breathing short-term RR, Raw, Crs, VmaxFRC, TGV metaproterenol and atropine independently had a positive effect on lung mechanics, however there were no synergistic effects
Kugelman[38] 2006 GA = preterm, spont. breathing with evolving BPD on inhaled medications 10 27 898 66 terbutaline & budesonide jet neb., 2mg & 0.5ml NA spont. breathing short-term infant tolerance, user choice, respir. scores, HR, RR, SPO2, FIO2 hood therapy took less time, was better tolerated and as effective as mask therapy

*common exclusion criteria included but was not limited to congenital anomalies, pulmonary infection, sepsis, treatment with corticosteroids and bronchodilators, air leak disorders, etc.

combined value from cases & controls, in some cases estimated based on reported data,

estimated dose emitted from canister for all MDI delivery methods,

MMAD emitted from MDI actuator,values derived from references [3941],

§ short-term outcome = single dose response, long-term outcome = outcome based on multiple treatment sessions (e.g. time to extubation, duration of therapy, development of BPD, length of stay, death, etc), || dose doubled if greater than 1200g

Table 1 abbreviations. beclomethasone (beclometh.), blood pressure (BP), bronchopulmonary dysplasia (BPD), birth weight (BW), capillary blood gas (CBG), lung compliance (CL,dyn), chlorofluorocarbon propellant (CFC), respiratory system compliance (Crs), cerebrospinal fluid (CSF), day (d), days of life (DOL), fraction of inspired oxygen (FIO2), gestational age (GA), hour (h), hydrofluoroalkane propellant (HFA), heart rate (HR), interleukin -1 receptor agonist (Il-1ra), interleukin-8 (IL-8), intravenous (IV), length of stay (LOS), minute (min), mechanical ventilation (mech. vent.), mass median aerodynamic diameter (MMAD), not applicable (NA), not defined (ND), nebulizer (neb.), partial pressure of carbon dioxide (PCO2), post menstrual age (PMA), partial pressure of oxygen (PO2), airway resistance (Raw), respiratory distress syndrome (RDS), lung resistance (RL,dyn), respiratory (resp.) respiratory rate (RR), respiratory system resistance (Rrs), seconds (s), oxygen saturation by pulse oximetry (SPO2), supplemental (suppl.), thoracic gas volume (TGV), treatment (TX), valved holding chamber (VHC), maximum exhaled volume from functional residual capacity (VmaxFRC)

Table 2. Quality Assessment of Included Randomized Controlled Trials (n = 22).

First author (year) Random sequence generation Allocation concealment Double Blinded Power calculation Exact point statistic reported Risk of bias
Fok [17] 1996 Computer Unclear Unclear No No High
Fok [18] 1998 Computer Unclear No No No High
Gappa [19] 1997 Unclear Unclear Unclear Yes Yes (mean,CI) Unclear
Pfenninger [20] 1993 Unclear Envelope Unclear No No High
Rotschild [21] 1989 Unclear Unclear Yes No No High
Bassler [22] 2015 Computer Envelope Yes Yes Yes (OR,CI) Low
Cole [23] 1999 3rd party Unclear Yes No Yes (RR,CI) High
Cole [24] 1999 3rd party Unclear Yes No No High
Dimitriou [25] 1997 Unclear Envelope Unclear Yes No High
Dugas [26] 2005 Block Unclear Yes Yes No High
Fok [27] 1999 Computer Envelope No Yes Yes (OR,CI) High
Merz [28] 1999 3rd party Unclear Yes No No High
Giep [29] 1996 Unclear Unclear Yes No No High
Gupta [30] 2000 3rd party Unclear Yes No No High
Halliday [31] 2001 3rd party Unclear No Yes Yes (OR,CI) High
Kovacs [32] 1998 Block Unclear Yes Yes No High
LaForce [33] 1993 Unclear Unclear No No No High
Rozycki [34] 2003 Number Table Unclear Yes Yes No High
Suchomski [35] 2002 Unclear Envelope No Yes No High
Denjean [36] 1998 Unclear Unclear Yes Yes Yes (OR,CI) Unclear
Kao [37] 1989 Unclear Unclear Yes No No High
Kugelman [38] 2006 Unclear Envelope No Yes No High

Inhaled Beta-Agonists

Five studies evaluated inhaled beta-agonist therapy with salbutamol (International Nonproprietary Name), also known as albuterol (United States Adopted Name) [1721]. The combined characteristics of these studies are summarized in Table 3. These studies included 84 subjects with a weighted gestational age (GA) of 27.1 (26–30) weeks, weighted birth weight (BW) of 974 (843–1310) grams, weighted postmenstrual age (PMA) of 34.8 (28–39) weeks, and a weighted age of 53 (15–86) days old at the time of evaluation. Doses of 200 μg by metered dose inhaler (MDI) and 100μg/kg to 2.5 mg nebulized solution were used. Delivery methods included metered dose inhaler MDI, jet nebulizer, and ultrasonic nebulizer to both mechanically ventilated and spontaneously breathing subjects.

Table 3. Summary of Subject and Study Characteristics of 22 Randomized Control Trials of Inhaled Therapies in Bronchopulmonary Dysplasia.

Beta-agonists Inhaled Corticosteroids Combination Therapies
Number of randomized control trials 5 14 3
Subject Characteristics
Total number of subjects (n) 84 2383 198
Subjects who were treated (n) 84 1212 155
Gestational age*, range (weeks) 27.1(26–30) 26.2(26–29) 27.8(27–29)
Birth weight*, range (g) 974(843–1310) 853(760–1114) 1057(898–1247)
Post menstrual age at time of study* (weeks) 34.8(28–39) 27.0(26–31) 30.7(29–45)
Chronological age at time of study*, range (d) 53(15–86) 6(0–45) 20(10–111)
Duration of therapy*, range (d) 7(1–28) 27(7–56) 25(1–28)
Mechanically Ventilated (%) 76.2 86.4 57.6
Delivery Devices
MDI (%) 40 96.3 87.4
Jet Nebulizer (%) 47.5 3.4 12.6
Ultra Sonic Nebulizer (%) 12.5 0 0
Outcomes Assessed
Short-term (%) 100 0 12.6
Long-term (%) 0 100 87.4

* Weighted average

Short-term outcome = single dose response

Long-term outcome = outcome based on multiple treatment sessions (e.g. time to extubation, duration of therapy, development of BPD, length of stay, death, etc)

Beta-agonist delivery

Salbutamol delivery devices were evaluated in 3 of the 5 included beta-agonist studies [1719]. Methods to assess delivery included radio-labeled aerosol with gamma imaging,[17] measurements of respiratory system compliance (Crs) and resistance (Rrs),[18] and measurements of lung compliance (CL,dyn) and resistance (RL,dyn) [19]. One study compared MDI and jet nebulizer efficacy in both spontaneously breathing and mechanically ventilated infants and concluded that larger doses, as measured by radio-labeled aerosol deposition, were delivered to both subject groups by MDI and holding chamber [17]. However, a similar study limited to spontaneously breathing subjects with BPD at 36 weeks postmenstrual age concluded there were no differences in delivery efficacy, measured as lung compliance and resistance, between the two modalities [19]. In the third study, an ultrasonic nebulizer, MDI, and jet nebulizer were compared in mechanically ventilated subjects [18]. Deposition to the periphery as determined by physiologic changes seemed to be greatest with an ultrasonic nebulizer placed 20 cm from the endotracheal tube, followed by the MDI with holding chamber, then the jet nebulizer respectively [18]. Studies assessing delivery of inhaled salbutamol demonstrate that aerosol delivery to the lower airways in both spontaneously breathing and mechanically ventilated infants is highly variable [1719].

Short-term beta-agonist efficacy

The short-term efficacy of inhaled salbutamol was assessed in 2 of the 5 beta-agonist studies [20, 21]. The first study evaluated inhaled salbutamol MDI in comparison to systemic delivery by the IV route in mechanically ventilated subjects [20]. Analysis of Crs and Rrs following drug delivery revealed that both methods were equally efficacious showing Crs and Rrs improvements; both methods had a similar effect on heart rate. The second study assessed the efficacy of inhaled salbutamol by jet nebulizer compared to an inhaled placebo in mechanically ventilated preterm infants with evolving BPD [21]. Changes in partial pressure of carbon dioxide, Crs and Rrs following delivery were evaluated. This study concluded that inhaled beta agonists started as early as the second week of life may be beneficial in the treatment of evolving BPD.

Inhaled Corticosteroids

Fourteen studies evaluated ICS therapy (beclomethasone, budesonide, fluticasone) [2235]. See Fig 2 for the medication distribution of the inhaled corticosteroids used. The combined characteristics of these studies are summarized in Table 3. They included 2383 subjects with a weighted GA of 26.2 (26–29) weeks, weighted BW of 853 (760–1114) grams, weighted PMA of 27.0 (26–31) weeks, and had a weighted age of 6 (0–45) days old at time of evaluation. Dosing regimens varied greatly as described in Table 1. Delivery methods included MDI and jet nebulizer to both mechanically ventilated and spontaneously breathing subjects.

Fig 2. Distribution of Inhaled Medications.

Fig 2

Distribution by drug classification of the inhaled therapies used among the 22 randomized control trials.

The safety of inhaled beclomethasone was evaluated in 2 of the 14 studies [24, 29]. Each used an estimated MDI emitted dose of 1000 μg/kg/d using and assessed for the presence of adrenal suppression as a safety outcome marker. One study found no difference between plasma cortisol levels between the treatment and control groups and concluded that beclomethasone MDI can be delivered safely to neonates [29]. However, mildly reduced plasma cortisol levels were found in the other study, but they found no evidence of adrenal suppression during cosyntropin stimulation [24]. This study suggests further research is needed to clarify ICS therapy in neonates and such studies should focus on a variety of formulations, regimens, and delivery systems.

Therapeutic efficacy of ICS was assessed in 12 of the 14 studies [22, 23, 2528, 3035]. Two of these studies [32, 33] used a jet nebulizer, while the remaining utilized a MDI and holding chamber. Various outcome measure were assessed including changes in Crs, Rrs, inflammatory markers, and clinical outcomes such as duration of treatment, oxygen days, time to extubation, the development of BPD, length of stay, and death. Five of these studies compared ICS (budesonide [25, 31, 32] and beclomethasone [34, 35]) to systemically administered dexamethasone for infants with evolving BPD. Four of the studies included only mechanically ventilated subjects, [31, 32, 34, 35] whereas one study included both mechanically ventilated and spontaneously breathing subjects [26]. These studies revealed that ICS therapy had a slower onset of action, and was less effective in treating pulmonary inflammation as compared to systemic therapy. However, ICSs offered the benefit of fewer adverse side effects. The other seven studies evaluated the efficacy of ICS therapies (beclomethasone, [23, 30, 33] fluticasone, [26, 27] and budesonide [22, 28]) compared against inhaled placebo. Four of the studies included only mechanically ventilated subjects, [23, 27, 28, 30] whereas three studies included both mechanically ventilated and spontaneously breathing subjects [22, 26, 33]. In all but two studies [26, 28], subjects who were treated with ICS therapy exhibited improved outcomes over those treated with placebo. Noted improvements included earlier extubation [23, 27], reduced supplemental oxygen need [22], less systemic steroid use [23, 30], increased Crs[27, 33]and decreased Rrs [33], and reduced risk of BPD [22,30].

Combination Therapies

Three studies evaluated combination therapies [3638]. See Fig 2 for the medication distribution of the inhaled combination therapies used. The combined characteristics of these studies are summarized in Table 3. They included 198 subjects with a weighted GA of 27.8 (27–29) weeks, weighted BW of 1057 (898–1247) grams, weighted PMA of 30.7(29–45) weeks and had a weighted age of 20 (10 to 111) days old at time of evaluation. Beta agonist and ICS combinations were assessed in 2 of the 3 studies [36, 38]. The third study assessed the combination of a beta agonist and an anticholinergic [37]. Delivery methods included MDI for mechanically ventilated subjects, whereas MDI (mask with spacer) [36] and jet nebulizer (mask [37, 38] and/or hood [38]) were used for spontaneously breathing subjects.

In the first study evaluating the combination of a beta agonist and ICS (salbutamol, 1200 μg/kg/d and beclomethasone, 1000 μg/kg/d), the effectiveness of treatment was assessed using long-term outcomes such as BPD and death, and no significant differences were found between treatment groups and placebo [36]. The second beta agonist/ICS (terbutaline, 2 mg and budesonide, 0.5ml in 2ml of sodium chloride) combination study evaluated the delivery methods of aerosol hood and mask with a jet nebulizer [38]. In this study, patient tolerance and user preferences were assessed as primary outcomes. Secondary outcomes evaluated the efficacy of each delivery method. Results revealed that patients tolerated hood delivery better and users preferred this method over aerosol mask, additionally, the hood delivery was found to be at least as efficacious as the mask.

The remaining study assessed the combination of metaproterenol, 1 mg and atropine, 0.8 mg/kg [37]. This study used a jet nebulizer to deliver the combination therapy to spontaneously breathing subjects. Both metaproterenol and atropine individually had a positive effect on Rrs and maximum exhaled volume from functional residual capacity. However, there was no synergistic response when the drugs were combined.

Discussion

Review of these 22 randomized control trials suggest flow obstruction associated with airway smooth muscle constriction and inflammation in infants on supplemental oxygen and mechanical ventilation can be alleviated through inhaled therapies. Evidence of such benefit is documented with improvements in Crs and Rrs following beta agonists, anticholinergics, and ICS therapies. However, clinically relevant long-term benefits such as reduced BPD, time to extubation, duration of supplemental oxygen, and length of stay remain unclear or absent. Additionally, variables such as age at study enrollment, point of BPD progression, and aerosol delivery methods, dose, etc. could potentially affect interpretation of study results.

This review is not without limitations. Limitations mostly involve adherence to strict inclusion criteria. Over 140 manuscripts were excluded for not meeting the minimum requirement of being randomized control design. Additionally, some studies could have been missed that were not indexed in the Academic Search Complete, CINAHL, PUBMED/MEDLINE, and Scopus databases. Including only studies of randomized control design, we attempted to minimize unmeasured bias; however, the quality assessment of data revealed an overall high risk of potential bias still remained.

Recent systematic reviews have provided insight to specific outcomes related to inhaled bronchodilator and ICS therapies in BPD, however, strict inclusion criteria of these reviews limit the ability to consider the complete body of work done in this area [10,11]. In order to meet our objective of identifying strengths and knowledge gaps in the literature regarding inhaled therapies in BPD and guide future research, we had to take a liberal approach and include within the analysis a wide range of outcomes, this created heterogeneity. Based on the National Academy of Medicine’s (formerly known as Institute of Medicine) guidelines [42], no quantitative synthesis (meta-analysis) was attempted due to the large degree of heterogeneity and quality assessment of included studies.

Despite a lack of evidence to support long-term use of bronchodilators, review of these randomized control studies has revealed that beta-agonists and anticholinergic therapies can acutely improve lung function in infants with evolving BPD [1821, 37]. This is further supported in other observational studies [4348]. Included in this review, Kao and colleagues (1989) used a jet nebulizer to deliver metaproterenol and atropine to fifteen spontaneously breathing subjects, nine of which remained on supplemental oxygen support [37]. Improvements in pulmonary function were noted by reduced Rrs and increased exhaled volume from functional residual capacity after administration of each inhaled medication independently. However, no synergistic effect was noted. Similarly, in an observational study DeBoeck and colleagues (1998) evaluated the combination of salbutamol and ipratropium bromide by jet nebulizer and face mask to twenty spontaneously breathing subjects with BPD [47]. Evaluating Rrs, they did not observe a synergistic benefit of combined therapy. However, Brundage and colleagues (1990) were able to achieve a synergistic effect when the dose of ipratropium bromide was increased above the standard dose [46]. Fok et al. [18] and Kao et al. [37] revealed through measurements of Rrs that the bronchodilator effect of salbutamol subsides after two and three hours respectively. Brundage et al. demonstrated that the synergistic effect of combined salbutamol and ipratropium bromide can promote a longer bronchodilator effect than each drug given independently [46]. They observed a continued effect at four hours post treatment. Due to a relatively short duration of bronchodilation with beta agonist therapy, further research is warranted to evaluate other combination therapies such as the long acting bronchodilator formoterol in combination with budesonide.

There are mixed results regarding the efficacy of ICS therapy in this review. Some studies suggest that they provide no benefit, [26, 28, 31, 32, 34, 35] whereas, others reveal ICS therapy can be safe and beneficial [22, 23, 27, 29 30, 33]. Studies do show that ICSs have a slower onset of action as compared to systemic steroids and can have similar side effects [24, 25, 31, 34, 35]. Careful review of the literature included in this paper suggests that ICS effectiveness may directly increase with prescribed dose. Seven ICS studies had prescribed doses of ≥ 1000 μg/day [23, 24, 2730, 32]. Giep and colleagues (1996) found no short-term adverse effects at this dose level of MDI beclomethasone in nineteen mechanically ventilated subjects [29]. Three of these studies (beclomethasone [23, 30] & fluticasone [27]) that reported improved outcomes with ICS therapy had prescribed these higher doses [23, 24, 27, 30]. Two studies with no noted improvements at that ≥ 1000 μg/day dose level differed from the other studies [28, 32]. Kovács and colleagues (1998) used a jet nebulizer to deliver budesonide to mechanically ventilated subjects [32]. In comparison to other studies where improvements were noted, [23, 24, 27, 30] their study differed from others in both study medication and delivery method. In the remaining study that utilized a higher dose, but did not see improved outcomes, Merz and colleagues (1999) used a MDI, spacer and hand ventilation to deliver budesonide to mechanically ventilated subjects [28]. The duration of treatment in their study only lasted for 10 days, whereas, studies that showed improvements at this dose range reported treatment durations from 14 to 28 days in length [23, 24, 27, 30]. In regard to lower (<1000 μg/day) doses, one study (budesonide [22]) reported improved outcomes at a dose of 800 μg/day, whereas two studies (beclomethasone [34] & fluticasone [26]) report no benefit of ICS therapy with doses of 17 to 250 μg [26, 34]. Further research is needed to explore the safe and effective dosages in ICS therapy for infants with BPD. Despite having some evidence that ICS therapy can be beneficial in regards to improving outcomes such as duration of respiratory support, improvements in long-term outcomes of ICS therapy such as reduced length of stay, mortality, etc. are still lacking [22, 2528, 31, 32, 35]. Denjean and colleagues (1998) in a randomized double blind trial evaluated combined salbutamol, 1200μg/d and beclomethasone, 1000μg/d [36]. They found no differences in development of BPD or mortality in a sample of 173 subjects [36]. In a recent trial, the largest to date (n = 863 infants), Bassler and colleagues (2015) aimed to maximize budesonide delivery to infants on CPAP and mechanical ventilation with a spacer device, in order to evaluate its effectiveness in reducing BPD and 18–22 month neurodevelopmental outcome [22, 49, 50]. They found no significant change in mortality following budesonide randomization at 12 hours of age until infants were either off supplementary oxygen and positive pressure support or had reached a gestational age of 32 0/7 weeks, but found a reduction of BPD at 36-weeks (relative risk 74 (0.60–0.91)) [22]. In addition to a large sample size, they conclude possible factors attributing to their positive findings could include a modest dose of ICS to augment lung deposition and early versus late initiation of therapy [22]. Additionally, they used a budesonide MDI formulation with valved holding chamber for delivery that was previously unavailable [22, 40, 51]. They were able to show a therapeutic benefit at a lower dose than previous studies [22]. Responses to therapies are dependent on the amount of aerosol delivered to the peripheral airways. Aerosol with a mass median aerodynamic diameter of 1–5 μm are capable of reaching the periphery [52]. Deposition can be effected by many variables such as aerosol composition, infant anatomy, the presence of an artificial airway, aerosol delivery devices, etc. [3941, 5255]. Due to the Montreal Protocol (1987), pharmaceutical companies were forced to develop MDIs with an environmental friendly propellant [56]. As a result, newly developed hydrofluoroalkane propelled formulations have a smaller mass median aerodynamic diameter as compared to traditional chlorofluorocarbon propelled devices [3941]. The study conducted by Bassler et. al (2015) is the only study in this review conducted in the hydrofluoroalkane era [22].

There were multiple methods in which aerosols were delivered in this review. Four studies specifically evaluated delivery methods [1719, 38]. Fok and colleagues (1996) used radiolabeled salbutamol and gamma imaging to evaluate two standardized delivery methods in spontaneously breathing and mechanically ventilated subjects [17]. Although lung deposition was small and variable, they found the MDI with a chamber spacing device placed inline to be a more efficacious method of delivery when compared to a jet nebulizer. However, Gappa and colleagues (1997) found the two devices to be equally efficient in delivery of salbutamol to spontaneously breathing subjects by measures of pulmonary mechanics [19]. Fok and colleagues (1998) again evaluated salbutamol delivery methods in a follow-up study of mechanically ventilated subjects [18]. The same two delivery methods were assessed as in their previous study, however, a third method; the ultrasonic nebulizer was added for evaluation. Findings revealed that the ultrasonic nebulizer out performed both the MDI and jet nebulizer with greater reductions in Rrs. Kugelman and colleagues (2006) evaluated terbutaline and budesonide combination therapy in spontaneously breathing subjects delivered by both hood and mask nebulization [38]. They concluded that hood nebulization was better tolerated by infants and was preferred over mask nebulization by users administering the aerosol treatments. Additionally, they concluded that hood nebulization was at least as effective as mask delivery based on respiratory assessment scores. Such scores rely on caregiver observations of retractions, assessment of breath sounds, and other measures that can be subjective and highly variable between scorers [57, 58]. Caution is necessary when drawing conclusions based on such observations. Future studies should focus on using clear objective physiological data when analyzing outcomes. Considering that there were only four studies [1719, 38] with randomized design that evaluated the effectiveness of delivery methods to infants with BPD, it remains unclear which methods are optimal. Furthermore, these studies are now one to two decades old. Technology across this time frame has brought about many new products aimed at improving aerosol delivery. Specially designed masks with reduced dead space, innovative nebulizers, and redesigned MDI spacers are examples of new products that may prove beneficial in this select patient population [51, 5962]. It is likely that the most optimal method of aerosol delivery will vary per the infant’s modality of respiratory support (e.g. infants on supplemental oxygen vs. nasal continuous positive airway pressure vs. mechanical ventilation) [51, 6366]. Future research should focus on the evaluation of new and existing devices across different modalities of respiratory support. Additionally, new drugs and novel use of existing medications should be evaluated. Inhaled agents such as nitric oxide, furosemide, and pentoxifylline have been studied in infants with or at risk of developing BPD [6769]. Due to a limited number of randomized control studies, no clear conclusions can be made regarding these novel drugs in infants with BPD.

Subjects’ ages at time of evaluation were well defined in all but one study in this review [33]. Based on the mean GA and age at time of evaluation, only one study evaluated inhaled medications in BPD beyond age corrected to term GA [37]. Given variability in age at time of evaluation, we should be cautious in making generalized statements that inhaled beta agonists, muscarinic antagonists, corticosteroids, or any combination of these therapies are ineffective in treating BPD. There are many variations in the clinical presentation and characteristics in infants who have evolving versus established BPD. Likewise, there are also many differences in degrees of BPD severity [14]. Since the majority of these past studies evaluated aerosol therapy in evolving BPD, it remains unclear whether or not such therapies are beneficial for post-term infants with chronic stable disease.

The pulmonary function measures used to assess response to therapy in this review are predominantly measures of Crs and Rrs. These measures can be highly variable and not as sensitive to changes in airway flow resistance [44, 47, 70]. “Adult-type” infant pulmonary function methods and equipment have become available for use infants since the studies included in this review, these tests are highly reproducible [71, 72]. De Boeck and colleagues (1998) noted that pulmonary function measures of forced flow may be a more sensitive and appropriate measures of airway response compared to Rrs [47]. Equally important, they concluded that not all infants with BPD respond to aerosol therapy, therefore, infants should be screened before starting treatments. Robin and colleagues (2004) assessed bronchodilator responsiveness in twenty-eight subjects with chronic stable BPD [73]. MDI albuterol was delivered by chamber and facemask to seventeen subjects who underwent pre and post bronchodilator response testing during infant pulmonary function testing. Only thirty five percent of patients had a significant positive response measured by forced expiratory flow analysis. In a longitudinal study evaluating lung volumes and forced flows by pulmonary function testing of forty four subjects with moderate to severe BPD at six, twelve, and twenty four months after discharge; Fakhourly and colleagues (2010) reported that response to bronchodilators was at thirty percent at six months post discharge and tapered to twenty percent by the end of the study at twenty four months post discharge [74]. This phenomenon could be related to tachyphylaxis, better control of airway hyper-reactivity though the use of controller medications such as ICS, or to new lung growth and healing associated with increasing age. These changes in response further suggest that children with BPD have a variable response to inhaled medications, which could be related to disease progression and severity. Since bronchodilators are short-acting medications and used as rescue medications in obstructive lung diseases as opposed to controller medications that aim to improve longer-term outcomes, future studies of their effectiveness in bronchodilator responders with BPD might consider physiologic symptom relief and patient comfort as a relevant and important patient-centered outcome.

Considering only approximately thirty percent of children with BPD are responders to bronchodilators, [73, 74] subjects should be carefully screened for responsiveness before being treated or enrolled in research evaluating the outcomes of such therapies [75]. We should be hesitant of past studies where subjects were treated without being screened for responsiveness. Inclusion of non-responders in treatments groups could potentially mask benefits of therapy in true responders and affect the outcome and interpretation of results. Future research should focus on evaluating bronchodilator/ICS therapies and their effect on long-term outcomes in subjects who are known responders to such therapies. This can be accomplished by utilizing infant pulmonary function testing methodology with a bronchodilator challenge [72, 76]. This would allow researchers to stratify subjects into responder and non-responder groups. Additional repeated measures after the initiation of ICS therapies could provide valuable insight to those with flow obstruction due to reactive airways and inflammation.

Summary

In summary, this review reports on twenty-two randomized control trials pertaining to the use of inhaled beta agonists, anticholinergics, and corticosteroids in infants with BPD. Although these inhaled therapies seem to have some benefit, there is very limited data to suggest these treatments improve long-term outcomes in infants with BPD. The majority of existing literature focuses on evolving BPD. Further research is needed to evaluate bronchodilator use in infants with chronic stable BPD. New inhaled drugs and devices have been developed since the publication of much of the literature included in this review. Future studies should evaluate new drug combinations and devices as compared to traditional methods. These studies should aim to find the optimal method of delivery across all modalities of respiratory support. Finally, infants should be stratified into responder and non-responder groups so that potential benefits of therapy are not masked by non-responders.

Supporting Information

S1 File. PRISMA Checklist.

(DOC)

Acknowledgments

We are indebted to the guidance and insight provided by Robert G Castile, MD, MS of The Research Institute at Nationwide Children’s Hospital.

Abbreviations

BPD

bronchopulmonary dysplasia

BW

birth weight

CL, dyn

lung compliance

Crs

respiratory system compliance

GA

gestational age

ICS

inhaled corticosteroids

MDI

metered dose

RL, dyn

lung resistance

Rrs

respiratory system resistance

Data Availability

All relevant data are within the paper and its Supporting Information files.

Funding Statement

The authors have no support or funding to report.

References

  • 1.Tin W, Wiswell TE. Adjunctive therapies in chronic lung disease: examining the evidence. Semin Fetal Neonatal Med. 2008;13(1):44–52. Epub 2007/11/07. [DOI] [PubMed] [Google Scholar]
  • 2.Tin W, Wiswell TE. Drug therapies in bronchopulmonary dysplasia: debunking the myths. Semin Fetal Neonatal Med. 2009;14(6):383–90. Epub 2009/09/15. 10.1016/j.siny.2009.08.003 [DOI] [PubMed] [Google Scholar]
  • 3.Fok TF. Adjunctive pharmacotherapy in neonates with respiratory failure. Semin Fetal Neonatal Med. 2009;14(1):49–55. Epub 2008/10/15. 10.1016/j.siny.2008.08.002 [DOI] [PubMed] [Google Scholar]
  • 4.Bancalari E, Wilson-Costello D, Iben SC. Management of infants with bronchopulmonary dysplasia in North America. Early Hum Dev. 2005;81(2):171–9. Epub 2005/03/08. [DOI] [PubMed] [Google Scholar]
  • 5.Allen J, Zwerdling R, Ehrenkranz R, Gaultier C, Geggel R, Greenough A, et al. ATS statement on the care of the child with chronic lung disease of infancy and childhood. Am J Respir Crit Care Med. 2003;168(3):356–96. Epub 2003/07/31. [DOI] [PubMed] [Google Scholar]
  • 6.Cuevas Guaman M, Gien J, Baker CD, Zhang H, Austin ED, Collaco JM. Point prevalence, clinical characteristics, and treatment variation for infants with severe bronchopulmonary dysplasia. Am J Perinatol. 2015. Epub 2015/03/05. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 7.Slaughter JL, Stenger MR, Reagan PB, Jadcherla SR. Utilization of inhaled corticosteroids for infants with bronchopulmonary dysplasia. PloS One. 2014;9(9):e106838 Epub 2014/09/06. 10.1371/journal.pone.0106838 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 8.Slaughter JL, Stenger MR, Reagan PB, Jadcherla SR. Inhaled bronchodilator use for infants with bronchopulmonary dysplasia. J Perinatol. 2015;35(1):61–6. Epub 2014/08/08. 10.1038/jp.2014.141 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 9.Ballard J, Lugo RA, Salyer JW. A survey of albuterol administration practices in intubated patients in the neonatal intensive care unit. Respir Care. 2002;47(1):31–8. Epub 2001/12/26. [PubMed] [Google Scholar]
  • 10.Ng GY, da S, Ohlsson A. Bronchodilators for the prevention and treatment of chronic lung disease in preterm infants. Cochrane Database Syst Rev. 2001(3):CD003214 Epub 2001/11/01. [DOI] [PubMed] [Google Scholar]
  • 11.Onland W, Offringa M, van Kaam A. Late (>/ = 7 days) inhalation corticosteroids to reduce bronchopulmonary dysplasia in preterm infants. Cochrane Database Syst Rev. 2012(4):CD002311. Epub 2012/04/20. [DOI] [PubMed] [Google Scholar]
  • 12.Maas C, Poets CF, Bassler D. Survey of practices regarding utilization of inhaled steroids in 223 German neonatal units. Neonatology. 2010;98(4):404–8. Epub 2010/11/06. 10.1159/000316978 [DOI] [PubMed] [Google Scholar]
  • 13.Northway WH Jr., Rosan RC, Porter DY. Pulmonary disease following respirator therapy of hyaline-membrane disease: bronchopulmonary dysplasia N Engl J Med. 1967;276(7):357–68. [DOI] [PubMed] [Google Scholar]
  • 14.Jobe AH, Bancalari E. Bronchopulmonary dysplasia. Am J Respir Crit Care Med. 2001;163(7):1723–9. Epub 2001/06/13. [DOI] [PubMed] [Google Scholar]
  • 15.Moher D, Liberati A, Tetzlaff J, Altman DG. Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement. BMJ. 2009;339:b2535 Epub 2009/07/23. 10.1136/bmj.b2535 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 16.Garrard J. Health sciences literature review made easy: the matrix method. 3rd ed Sudbury, MA: Jones and Bartlett Publishers; 2011. xi, 211 p. p. [Google Scholar]
  • 17.Fok TF, Monkman S, Dolovich M, Gray S, Coates G, Paes B, et al. Efficiency of aerosol medication delivery from a metered dose inhaler versus jet nebulizer in infants with bronchopulmonary dysplasia. Pediatr Pulmonol. 1996;21(5):301–9. Epub 1996/05/01. [DOI] [PubMed] [Google Scholar]
  • 18.Fok TF, Lam K, Ng PC, So HK, Cheung KL, Wong W, et al. Randomised crossover trial of salbutamol aerosol delivered by metered dose inhaler, jet nebuliser, and ultrasonic nebuliser in chronic lung disease. Arch Dis Child Fetal Neonatal Ed. 1998;79(2):F100–4. Epub 1998/11/26. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 19.Gappa M, Gartner M, Poets CF, von der Hardt H. Effects of salbutamol delivery from a metered dose inhaler versus jet nebulizer on dynamic lung mechanics in very preterm infants with chronic lung disease. Pediatr Pulmonol. 1997;23(6):442–8. Epub 1997/06/01. [DOI] [PubMed] [Google Scholar]
  • 20.Pfenninger J, Aebi C. Respiratory response to salbutamol (albuterol) in ventilator-dependent infants with chronic lung disease: pressurized aerosol delivery versus intravenous injection. Intensive Care Med. 1993;19(5):251–5. Epub 1993/01/01. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 21.Rotschild A, Solimano A, Puterman M, Smyth J, Sharma A, Albersheim S. Increased compliance in response to salbutamol in premature infants with developing bronchopulmonary dysplasia. J Pediatr. 1989;115(6):984–91. Epub 1989/12/01. [DOI] [PubMed] [Google Scholar]
  • 22.Bassler D, Plavka R, Shinwell ES, Hallman M, Jarreau PH, Carnielli V, et al. Early Inhaled Budesonide for the Prevention of Bronchopulmonary Dysplasia. N Engl J Med. 2015;373(16):1497–506. Epub 2015/10/16. 10.1056/NEJMoa1501917 [DOI] [PubMed] [Google Scholar]
  • 23.Cole CH, Colton T, Shah BL, Abbasi S, MacKinnon BL, Demissie S, et al. Early inhaled glucocorticoid therapy to prevent bronchopulmonary dysplasia. N Engl J Med. 1999;340(13):1005–10. Epub 1999/04/01. [DOI] [PubMed] [Google Scholar]
  • 24.Cole CH, Shah B, Abbasi S, Demissie S, MacKinnon B, Colton T, et al. Adrenal function in premature infants during inhaled beclomethasone therapy. J Pediatr. 1999;135(1):65–70. Epub 1999/07/07. [DOI] [PubMed] [Google Scholar]
  • 25.Dimitriou G, Greenough A, Giffin FJ, Kavadia V. Inhaled versus systemic steroids in chronic oxygen dependency of preterm infants. Eur J Pediatr. 1997;156(1):51–5. Epub 1997/01/01. [DOI] [PubMed] [Google Scholar]
  • 26.Dugas MA, Nguyen D, Frenette L, Lachance C, St-Onge O, Fougeres A, et al. Fluticasone inhalation in moderate cases of bronchopulmonary dysplasia. Pediatrics. 2005;115(5):e566–72. Epub 2005/04/19. [DOI] [PubMed] [Google Scholar]
  • 27.Fok TF, Lam K, Dolovich M, Ng PC, Wong W, Cheung KL, et al. Randomised controlled study of early use of inhaled corticosteroid in preterm infants with respiratory distress syndrome. Arch Dis Child Fetal Neonatal Ed. 1999;80(3):F203–8. Epub 1999/04/22. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 28.Merz U, Kusenbach G, Hausler M, Peschgens T, Hornchen H. Inhaled budesonide in ventilator-dependent preterm infants: a randomized, double-blind pilot study. Biology of the Neonate. 1999;75(1):46–53. Epub 1998/11/30. [DOI] [PubMed] [Google Scholar]
  • 29.Giep T, Raibble P, Zuerlein T, Schwartz ID. Trial of beclomethasone dipropionate by metered-dose inhaler in ventilator-dependent neonates less than 1500 grams. Am J Perinatol. 1996;13(1):5–9. Epub 1996/01/01. [DOI] [PubMed] [Google Scholar]
  • 30.Gupta GK, Cole CH, Abbasi S, Demissie S, Njinimbam C, Nielsen HC, et al. Effects of early inhaled beclomethasone therapy on tracheal aspirate inflammatory mediators IL-8 and IL-1ra in ventilated preterm infants at risk for bronchopulmonary dysplasia. Pediatr Pulmonol. 2000;30(4):275–81. Epub 2000/10/03. [DOI] [PubMed] [Google Scholar]
  • 31.Halliday HL, Patterson CC, Halahakoon CW, European Multicenter Steroid Study G. A multicenter, randomized open study of early corticosteroid treatment (OSECT) in preterm infants with respiratory illness: comparison of early and late treatment and of dexamethasone and inhaled budesonide. Pediatrics. 2001;107(2):232–40. Epub 2001/02/07. [DOI] [PubMed] [Google Scholar]
  • 32.Kovacs L, Davis GM, Faucher D, Papageorgiou A. Efficacy of sequential early systemic and inhaled corticosteroid therapy in the prevention of chronic lung disease of prematurity. Acta Paediatrica. 1998;87(7):792–8. Epub 1998/08/29. [DOI] [PubMed] [Google Scholar]
  • 33.LaForce WR, Brudno DS. Controlled trial of beclomethasone dipropionate by nebulization in oxygen- and ventilator-dependent infants. J Pediatr. 1993;122(2):285–8. Epub 1993/02/01. [DOI] [PubMed] [Google Scholar]
  • 34.Rozycki HJ, Byron PR, Elliott GR, Carroll T, Gutcher GR. Randomized controlled trial of three different doses of aerosol beclomethasone versus systemic dexamethasone to promote extubation in ventilated premature infants. Pediatr Pulmonol. 2003;35(5):375–83. Epub 2003/04/11. [DOI] [PubMed] [Google Scholar]
  • 35.Suchomski SJ, Cummings JJ. A randomized trial of inhaled versus intravenous steroids in ventilator-dependent preterm infants. J Perinatol. 2002;22(3):196–203. Epub 2002/04/12. [DOI] [PubMed] [Google Scholar]
  • 36.Denjean A, Paris-Llado J, Zupan V, Debillon T, Kieffer F, Magny JF, et al. Inhaled salbutamol and beclomethasone for preventing broncho-pulmonary dysplasia: a randomised double-blind study. Eur J Pediatr. 1998;157(11):926–31. Epub 1998/12/03. [DOI] [PubMed] [Google Scholar]
  • 37.Kao LC, Durand DJ, Nickerson BG. Effects of inhaled metaproterenol and atropine on the pulmonary mechanics of infants with bronchopulmonary dysplasia. Pediatr Pulmonol. 1989;6(2):74–80. Epub 1989/01/01. [DOI] [PubMed] [Google Scholar]
  • 38.Kugelman A, Amirav I, Mor F, Riskin A, Bader D. Hood versus mask nebulization in infants with evolving bronchopulmonary dysplasia in the neonatal intensive care unit. J Perinatol. 2006;26(1):31–6. Epub 2005/12/13. [DOI] [PubMed] [Google Scholar]
  • 39.Cheng YS, Fu CS, Yazzie D, Zhou Y. Respiratory deposition patterns of salbutamol pMDI with CFC and HFA-134a formulations in a human airway replica. J Aerosol Med. 2001;14(2):255–266. [DOI] [PubMed] [Google Scholar]
  • 40.Clearie KL, Williamson PA, Meldrum K, Gillen M, Carlsson LG, Carlholm M, et al. Pharmacokinetic and pharmacodynamic comparison of hydrofluoroalkane and chlorofluorocarbon formulations of budesonide. British Journal of Clinical Pharmacology. 2011;71(4):504–13. Epub 2011/03/15. 10.1111/j.1365-2125.2010.03857.x [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 41.Leach C, Colice GL, Luskin A. Particle size of inhaled corticosteroids: does it matter? The Journal of allergy and clinical immunology. 2009;124(6 Suppl):S88–93. Epub 2010/01/09. 10.1016/j.jaci.2009.09.050 [DOI] [PubMed] [Google Scholar]
  • 42.Committee on Standards for Systematic Reviews of Comparative Effectiveness Research, Institute of Medicine. Finding What Works in Health Care: standards for systematic reviews. Washington, DC: National Academy Press; 2011. [Google Scholar]
  • 43.Kao LC, Warburton D, Platzker AC, Keens TG. Effect of isoproterenol inhalation on airway resistance in chronic bronchopulmonary dysplasia. Pediatrics. 1984;73(4):509–14. Epub 1984/04/01. [PubMed] [Google Scholar]
  • 44.Motoyama EK, Fort MD, Klesh KW, Mutich RL, Guthrie RD. Early onset of airway reactivity in premature infants with bronchopulmonary dysplasia. The American Review of Respiratory Disease. 1987;136(1):50–7. Epub 1987/07/01. [DOI] [PubMed] [Google Scholar]
  • 45.Wilkie RA, Bryan MH. Effect of bronchodilators on airway resistance in ventilator-dependent neonates with chronic lung disease. J Pediatr. 1987;111(2):278–82. Epub 1987/08/01. [DOI] [PubMed] [Google Scholar]
  • 46.Brundage KL, Mohsini KG, Froese AB, Fisher JT. Bronchodilator response to ipratropium bromide in infants with bronchopulmonary dysplasia. The American Review of Respiratory Disease. 1990;142(5):1137–42. Epub 1990/11/01. [DOI] [PubMed] [Google Scholar]
  • 47.De Boeck K, Smith J, Van Lierde S, Devlieger H. Response to bronchodilators in clinically stable 1-year-old patients with bronchopulmonary dysplasia. Eur J Pediatr. 1998;157(1):75–9. Epub 1998/02/14. [DOI] [PubMed] [Google Scholar]
  • 48.Nguyen P., Fitzgerald D., Davis MG. Response of very premature infants with bronchopulmonary dysplasia to inhaled salbutamol. Mcgill J Med. 1997;3(1):19–23. [Google Scholar]
  • 49.Bassler D, Halliday HL, Plavka R, Hallman M, Shinwell ES, Jarreau PH, et al. The Neonatal European Study of Inhaled Steroids (NEUROSIS): an eu-funded international randomised controlled trial in preterm infants. Neonatology. 2010;97(1):52–5. Epub 2009/07/11. 10.1159/000227294 [DOI] [PubMed] [Google Scholar]
  • 50.Bassler D. Inhalation or instillation of steroids for the prevention of bronchopulmonary dysplasia. Neonatology. 2015;107(4):358–9. Epub 2015/06/06. 10.1159/000381132 [DOI] [PubMed] [Google Scholar]
  • 51.DiBlasi RM, Coppolo DP, Nagel MW, Doyle CC, Avvakoumova VI, Ali RS, et al. A novel, versatile valved holding chamber for delivering inhaled medications to neonates and small children: laboratory simulation of delivery options. Respir Care. 2010;55(4):419–26. Epub 2010/04/22. [PubMed] [Google Scholar]
  • 52.Labiris NR, Dolovich MB. Pulmonary drug delivery. Part I: physiological factors affecting therapeutic effectiveness of aerosolized medications. British journal of clinical pharmacology. 2003;56(6):588–99. Epub 2003/11/18. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 53.Ari A, Atalay OT, Harwood R, Sheard MM, Aljamhan EA, Fink JB. Influence of nebulizer type, position, and bias flow on aerosol drug delivery in simulated pediatric and adult lung models during mechanical ventilation. Respir Care. 2010;55(7):845–51. Epub 2010/07/01. [PubMed] [Google Scholar]
  • 54.Ari A, Harwood RJ, Sheard MM, Fink JB. An in vitro evaluation of aerosol delivery through tracheostomy and endotracheal tubes using different interfaces. Respir Care. 2012;57(7):1066–70. Epub 2012/01/26. 10.4187/respcare.01167 [DOI] [PubMed] [Google Scholar]
  • 55.Xi J, Si X, Zhou Y, Kim J, Berlinski A. Growth of nasal and laryngeal airways in children: implications in breathing and inhaled aerosol dynamics. Respir Care. 2014;59(2):263–73. Epub 2013/07/04. 10.4187/respcare.02568 [DOI] [PubMed] [Google Scholar]
  • 56.United Nations Environment Programme. The Montreal Protocol on Substances that Deplete the Ozone Layer. 1987; Available: http://ozone.unep.org/en/handbook-montreal-protocol-substances-deplete-ozone-layer/5.
  • 57.Bekhof J, Reimink R, Brand PL. Systematic review: insufficient validation of clinical scores for the assessment of acute dyspnoea in wheezing children. Paediatr Respir Rev. 2014;15(1):98–112. Epub 2013/10/15. 10.1016/j.prrv.2013.08.004 [DOI] [PubMed] [Google Scholar]
  • 58.Bekhof J, Reimink R, Bartels IM, Eggink H, Brand PL. Large observer variation of clinical assessment of dyspnoeic wheezing children. Arch Dis Child. Epub 2015/02/24. [DOI] [PubMed] [Google Scholar]
  • 59.Amirav I, Luder AS, Halamish A, Raviv D, Kimmel R, Waisman D, et al. Design of aerosol face masks for children using computerized 3D face analysis. J Aerosol Med Pulm Drug Deliv. 2014;27(4):272–8. Epub 2013/10/01. 10.1089/jamp.2013.1069 [DOI] [PubMed] [Google Scholar]
  • 60.Sidler-Moix AL, Di Paolo ER, Dolci U, Berger-Gryllaki M, Cotting J, Pannatier A. Physicochemical aspects and efficiency of albuterol nebulization: comparison of three aerosol types in an in vitro pediatric model. Respir Care. 2015;60(1):38–46. Epub 2014/12/18. 10.4187/respcare.02490 [DOI] [PubMed] [Google Scholar]
  • 61.Mazela J, Chmura K, Kulza M, Henderson C, Gregory TJ, Moskal A, et al. Aerosolized albuterol sulfate delivery under neonatal ventilatory conditions: in vitro evaluation of a novel ventilator circuit patient interface connector. J Aerosol Med Pulm Drug Deliv. 2014;27(1):58–65. Epub 2013/03/21. 10.1089/jamp.2012.0992 [DOI] [PubMed] [Google Scholar]
  • 62.Longest PW, Tian G. Development of a new technique for the efficient delivery of aerosolized medications to infants on mechanical ventilation. Pharm Res. 2015;32(1):321–36. Epub 2014/08/12. 10.1007/s11095-014-1466-4 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 63.Farney KD, Kuehne BT, Gibson LA, Nelin LD, Shepherd EG. In vitro evaluation of radio-labeled aerosol delivery via a variable-flow infant CPAP system. Respir Care. 2014;59(3):340–4. Epub 2013/08/08. 10.4187/respcare.01904 [DOI] [PubMed] [Google Scholar]
  • 64.Sunbul FS, Fink JB, Harwood R, Sheard MM, Zimmerman RD, Ari A. Comparison of HFNC, bubble CPAP and SiPAP on aerosol delivery in neonates: An in-vitro study. Pediatr Pulmonol. Epub 2014/12/11. [DOI] [PubMed] [Google Scholar]
  • 65.Bar-Yishay E, Avital A, Springer C, Amirav I. Lung function response to bronchodilator nebulization via hood in wheezy infants: a pilot study. Isr Med Assoc J. 2011;13(1):39–43. Epub 2011/03/31. [PubMed] [Google Scholar]
  • 66.Sivakumar D, Bosque E, Goldman SL. Bronchodilator delivered by metered dose inhaler and spacer improves respiratory system compliance more than nebulizer-delivered bronchodilator in ventilated premature infants. Pediatr Pulmonol. 1999;27(3):208–12. Epub 1999/04/23. [DOI] [PubMed] [Google Scholar]
  • 67.Di Fiore JM, Hibbs AM, Zadell AE, Merrill JD, Eichenwald EC, Puri AR, et al. The effect of inhaled nitric oxide on pulmonary function in preterm infants. J Perinatol. 2007;27(12):766–71. Epub 2007/09/07. [DOI] [PubMed] [Google Scholar]
  • 68.Kugelman A, Durand M, Garg M. Pulmonary effect of inhaled furosemide in ventilated infants with severe bronchopulmonary dysplasia. Pediatrics. 1997;99(1):71–5. Epub 1997/01/01. [DOI] [PubMed] [Google Scholar]
  • 69.Lauterbach R, Szymura-Oleksiak J, Pawlik D, Warchol J, Lisowska-Miszczyk I, Rytlewski K. Nebulized pentoxifylline for prevention of bronchopulmonary dysplasia in very low birth weight infants: a pilot clinical study. J Matern Fetal Neonatal Med. 2006;19(7):433–8. Epub 2006/08/23. [DOI] [PubMed] [Google Scholar]
  • 70.Denjean A, Guimaraes H, Migdal M, Miramand JL, Dehan M, Gaultier C. Dose-related bronchodilator response to aerosolized salbutamol (albuterol) in ventilator-dependent premature infants. J Pediatr. 1992;120(6):974–9. Epub 1992/06/01. [DOI] [PubMed] [Google Scholar]
  • 71.Jones M, Castile R, Davis S, Kisling J, Filbrun D, Flucke R, et al. Forced expiratory flows and volumes in infants: normative data and lung growth. Am J Respir Crit Care Med. 2000;161(2 Pt 1):353–9. Epub 2000/02/15. [DOI] [PubMed] [Google Scholar]
  • 72.Castile R, Filbrun D, Flucke R, Franklin W, McCoy K. Adult-type pulmonary function tests in infants without respiratory disease. Pediatr Pulmonol. 2000;30(3):215–27. Epub 2000/09/06. [DOI] [PubMed] [Google Scholar]
  • 73.Robin B, Kim YJ, Huth J, Klocksieben J, Torres M, Tepper RS, et al. Pulmonary function in bronchopulmonary dysplasia. Pediatr Pulmonol. 2004;37(3):236–42. Epub 2004/02/18. [DOI] [PubMed] [Google Scholar]
  • 74.Fakhoury KF, Sellers C, Smith EO, Rama JA, Fan LL. Serial measurements of lung function in a cohort of young children with bronchopulmonary dysplasia. Pediatrics. 2010;125(6):e1441–7. Epub 2010/05/05. 10.1542/peds.2009-0668 [DOI] [PubMed] [Google Scholar]
  • 75.Mavunda K. Effects of inhaled metaproteronol and atropine on the pulmonary mechanics of infants with bronchopulmonary dysplasia (letter). Pediatr Pulmonol. 1989;7(4):284 Epub 1989/01/01. [DOI] [PubMed] [Google Scholar]
  • 76.Goldstein AB, Castile RG, Davis SD, Filbrun DA, Flucke RL, McCoy KS, et al. Bronchodilator responsiveness in normal infants and young children. Am J Respir Crit Care Med. 2001;164(3):447–54. Epub 2001/08/1. [DOI] [PubMed] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Supplementary Materials

S1 File. PRISMA Checklist.

(DOC)

Data Availability Statement

All relevant data are within the paper and its Supporting Information files.


Articles from PLoS ONE are provided here courtesy of PLOS

RESOURCES