ABSTRACT
Purpose: To describe the technique of deep sclerectomy with the new Esnoper-Clip® implant, the clinical outcome and the anatomic characteristics of filtering blebs, using anterior segment optical coherence tomography (AS-OCT).
Methods: A prospective case-series study was conducted in five eyes (5 patients) with open angle glaucoma. The fornix-based deep sclerectomy with Esnoper-Clip® implant was done by the same surgeon. In one case, mitomycin C was used during surgery. All participants underwent a complete ophthalmic examination and AS-OCT (Visante®) preoperatively, then at each follow-up visit, at 1 day, 1 week, 1 month, 6 months and 1 year postoperatively. Scans were obtained through sagittal and transversal plans to the implant.
Results: Intraocular pressure (IOP) was significantly reduced (p < 0.05) from a mean preoperative value of 23.4 ± 8.6 mm Hg (n = 3.8 glaucoma medications) to a postoperative value of 6.0 ± 2.5 (n = 0), 10.6 ± 5.4 (n = 0), 13 ± 1.6 (n = 0.4), 12.4 ± 2.1 (n = 0.2) and 14.4 ± 1.5 (n = 0.2) at 1 day, 1 week, 1 month, 6 months and 1 year respectively. AS-OCT allowed the visualization of the two plates of the implant (scleral and suprasciliary), the trabeculodescemetic membrane and the hyporeflective spaces in the bleb wall thickness and in suprascleral and suprachoroidal localizations. An immediate postoperative hypotony and an anteriorization of the implant associated to trabeculodescemetic membrane rupture, were detected, although without significant clinical repercussions.
Conclusion: Our first five deep sclerectomy with Esnoper-Clip implantation analysis suggest an effective and well-tolerated method to reduce IOP. AS-OCT is a noninvasive imaging technique that allows the anatomic analysis of the drainage mechanisms after glaucoma surgery.
How to cite this article: Vieira L, Noronha M, Lemos V, Reina M, Gomes T. Anterior Segment Optical Coherence Tomography Imaging of Filtering Blebs after Deep Sclerectomy with Esnoper-Clip Implant: One-year Follow-up. J Curr Glaucoma Pract 2014;8(3):91-95.
Keywords: Deep sclerectomy, Intraocular pressure, Esnoper-Clip implant, AS-OCT.
INTRODUCTION
In the last years, deep sclerectomy (DS) has gained importance in glaucoma surgical treatment. In contrast to trabeculectomy, it enhances aqueous humor outflow acting on the major resistance site without entering the anterior chamber, thus reducing the incidence of intra and postoperative overfiltration, hypotony and its potential sequelae.1-8 Moreover, the incidence of cataract,8-10 hyphema,5 endothelial damage11 and macular edema is lower5 with DS. Although it is widely accepted that the DS is safer, remains some controversy about the intraocular pressure (IOP)-lowering effects. Chiselita et al12 and Cheng et al1 described lower efficacy than trabeculectomy, in contrast to El Sayyad et al13 that described similar efficacy. Mitomycin-C and many types of implants (Aquaflow,® SK-Gel,® T-flux,® Esnoper®)2 have been used to improve the efficacy of this technique, with reported similar results to trabeculectomy,4,5,14 although it is not consensual.6,8 Esnoper-Clip® is a nonreabsorbable implant, which objective is to maximize all aqueous humor drainage pathways.
Anterior segment optical coherence tomography (AS-OCT) is a noninvasive, noncontact imaging technology that provides high-resolution cross-sectional images of anterior segment.15 It has been used to evaluate filtering blebs after trabeculectomy16-19 and DS,16,17,20-23 allowing a better understanding about aqueous humor drainage pathways and its function.
The purpose of this study was to describe the technique of deep sclerectomy with the new Esnoper-Clip® implant, the clinical outcome (IOP decrease and complications with one year follow-up) and the anatomic characteristics of filtering blebs, using AS-OCT. To our knowledge, this is the first clinical study to evaluate this new implant.
METHODS
Participant Selection
A prospective case-series study was conducted in five eyes of five patients (4♂: 1♀), with a mean age of 61 ± 15.6 years, followed in Glaucoma Section of Ophthalmology Department of Central Lisbon Hospital Center (Table 1). Three patients had primary open-angle glaucoma (POAG) and two pseudoexfoliative glaucoma (PEXG), with characteristic structural and functional findings. Two of them had previous cataract surgery for more than 6 months. All patients had uncontrolled glaucoma despite being on maximal medical therapy.
Table 1: Patients’ features
| Patient | Age | Gender | Eye |
Type of glaucoma |
Previous ocular surgeries |
||||||
| 1 | 58 | ♂ | Right | POAG | Cataract | ||||||
| 2 | 71 | ♀ | Left | PEXG | No | ||||||
| 3 | 51 | ♂ | Left | POAG | No | ||||||
| 4 | 43 | ♂ | Right | PEXG | No | ||||||
| 5 | 82 | ♂ | Left | POAG | Cataract |
PROCEDURES
Esnoper-Clip® is a nonabsorbable foldable implant with two plates (scleral and supraciliary), composed by 2-hydroxyethyl methacrylate, a nonionic polymer with low tendency for protein deposits. Its length, unfolded, is 5.5 mm (3 mm scleral plate and 2.5 mm supraciliary plate), the base width is 2.2 mm and the thickness is 0.2 mm (Fig. 1).
Fig. 1.

Esnoper-Clip® implant
The fornix-based deep sclerectomy with Esnoper-Clip® implant was done by the same surgeon. After scleral exposure, a superficial flap of a 1/3 of sclera thickness was created (5.0 × 5.0 mm), 1 mm beyond the limbus. Then, a second deeper flap was done (4.0 × 4.0 mm), the peeling of Schlemm’s canal was completed and the deepest sclera flap was excised, leaving the trabeculodescemetic membrane patent. Esnoper-Clip® implant was inserted, one plate in the intrascleral space and the other in the supraciliary space. At last, the scleral flap was sutured with monofilament 10-0 as long as the conjunctiva. In one case, mitomycin C was used during surgery (ethnic and inflammatory factors).
All participants underwent a full ophthalmologic examination (including measurement of IOP with Goldmann tonometer) and AS-OCT (Visante®) preope-ratively, then at 1 day, 1 week, 1 month, 6 months and 1 year postoperatively. Scans were done through sagittal and transversal plans to the implant (Fig. 2).
Fig. 2.

Anterior segment optical coherence tomography scans were done through sagittal and transversal plans to the implant (as shown by lines)
The number of glaucoma medications needed to lower IOP, after the surgical procedure, was documented.
STATISTICAL ANALYSIS
Statistical analysis was conducted using SPSS Statistics version 20.0. The average and standard deviation (SD) of IOP and number of glaucoma medications were calculated. These values were compared between the different follow-up times using Mann-Whitney test. p-values less than 0.05 were considered statistically significant.
Ethics Statement
The study was approved by the Human Research Ethics Committee of the Central Lisbon Hospital Center and followed the tenets of the Declaration of Helsinki. Written informed consent was obtained from all participants.
RESULTS
Intraocular pressure and number of glaucoma medications were significantly reduced (p < 0.05) from a preoperative value of 23.4 ± 8.6 mm Hg (n = 3.8 glaucoma medications) to a postoperative value of 6.0 ± 2.5 (n = 0), 10.6 ± 5.4 (n = 0), 13 ± 1.6 (n = 0.4), 12.4 ± 2.1 (n = 0.2) and 14.4 ± 1.5 (n = 0.2) at 1 day, 1 week, 1 month, 6 months and 1 year respectively (Table 2).
Table 2: Intraocular pressure and number of glaucoma medications (n) preoperatively and at 1 day, 1 week, 1 month, 6 months and 1 year postoperatively
| Preiperatively | 1 day | 1 week | 1 month | 6 months | 1 year | ||||||||||||||||||||
| IOP | n | IOP | n | IOP | n | IOP | n | IOP | n | IOP | n | ||||||||||||||
| Average ± | 23.4 | 3.8 | 6.0 ± | 0 ± | 10.6 | 0 ± | 13 ± | 0.4 ± | 12.4 ± | 0.2 ± | 14.4 ± | 0.2 ± | |||||||||||||
| standard | ± | ± | 2.5 | 0 | ± | 0 | 1.6 | 0.9 | 2.1 | 0.4 | 1.5 | 0.5 | |||||||||||||
| deviation | 8.6 | 0.4 | 5.4 | ||||||||||||||||||||||
Anterior segment optical coherence tomography allowed the visualization of the two plates of the implant (scleral and supraciliary), the trabeculodescemetic membrane and the hyporeflective spaces in the bleb wall thickness and in suprascleral and supra-choroidal localizations (Figs 3A to C).
Figs 3A to C.

Anterior segment optical coherence tomography: (A) Longitudinal scan showing the double plate of Esnoper-Clip® implant (arrow) and an intact trabeculodescemetic membrane (arrow head), (B) transversal scan showing the double plate of the Esnoper-Clip® implant (arrow) and an hyporeactive space suggestive of a scleral route (arrow head) between intrascleral space and suprascleral space, (C) longitudinal scan showing hyporeactive spaces in the bleb wall thickness (arrow) and in suprascleral (arrow head) and suprachoroidal localizations (empty arrow head)
As complications we have registered one eye with immediate postoperative hypotony, which was solved in 9 days, without sequelae. In other patient, we verified the anteriorization of the Esnoper-Clip® implant associated to trabeculodescemetic membrane rupture at 6-month follow-up (Figs 4A and B).
Figs 4A and B.

Anteriorization of the Esnoper-Clip® implant: (A) Image of the implant in the anterior chamber seen by gonioscopy, (B) longitudinal scan of AS-OCT showing the double plate of Esnoper-Clip® implant (arrow) and the ruptured trabeculodescemetic membrane (arrow head)
DISCUSSION
Previous studies suggested that DS with the use of implants have good efficacy and low rate of perioperative complications.1-8,14 During the first year of follow-up, we found a maintained postoperative IOP decrease after DS with Esnoper-Clip® implant, similar to the values published with other implants,20,22 with almost no need of glaucoma medications. The hypotony reported happened in the only patient in which mitomycin C was used, and so it may be correlated with its use. The anteriorization of the implant with trabeculodescemetic membrane rupture, registered at 6-month follow-up, did not show significant clinical repercussions or at the aqueous humor drainage, as noticed by the low IOP values measured. In contrast to other implants, such as Esnoper®, Esnoper-Clip® is not sutured to sclera so it may predispose to implant dislocation, a complication that was never been documented in 5 years of experience of the authors with the first implant.
In the last few years, with new technological advances, filtering bleb structure has been studied [by confocal microscopy,24,25 ultrasound biomicroscopy (UBM)20 and AS-OCT16-24] in order to better understand the drainage pathways and its role on glaucoma surgery success. In this study, AS-OCT allowed to analyze the localization of the implant, the trabeculodescemetic membrane and hyporeflective spaces suggesting liquid content and so its drainage pathways, as already described in the literature.16,17,19,20 Esnoper-Clip® implant acts as a space maintainer and leads to the aqueous humor drainage to suprachoroidal, supraescleral and intraconjunctival spaces, as suggested by the images captured by AS-OCT. Therefore, this high-resolution imaging method may complement the clinical evaluation during the follow-up time.
In order to understand the relevance of this new implant in the clinical practice, further prospective, controlled, randomized and multicenter studies, with larger samples and longer follow-up, would be important. Moreover, studies should be done to compare DS with Esnoper-Clip® with the use of other implants and with trabeculectomy with or without antimetabolites. Also, structure-function correlation studies, using AS-OCT, would be of value, as is already described for other implants.17,19-21,23,24
CONCLUSION
Our first five DS with Esnoper-Clip® implant analysis suggest an effective and well-tolerated method to reduce IOP. AS-OCT is a noninvasive imaging technique that allows morphological analysis of the drainage mechanisms after glaucoma surgery.
Footnotes
Source of support: Nil
Conflict of interest: None
Contributor Information
Luisa Vieira, Resident, Department of Ophthalmology, Central Lisbon Hospital Center Lisbon, Portugal.
Manuel Noronha, Resident, Department of Ophthalmology, Central Lisbon Hospital Center Lisbon, Portugal.
Vanessa Lemos, Resident, Department of Ophthalmology, Central Lisbon Hospital Center Lisbon, Portugal.
Maria Reina, Consultant, Department of Ophthalmology, Central Lisbon Hospital Center Lisbon, Portugal.
Teresa Gomes, Consultant, Department of Ophthalmology, Central Lisbon Hospital Center Lisbon, Portugal.
REFERENCES
- 1. Cheng JW, Xi GL, Wei RL, Cai JP, Li Y. Efficacy and tolerability of nonpenetrating filtering surgery in the treatment of open-angle glaucoma: a meta-analysis. Ophthalmologica. 2010;224(3):138–146. doi: 10.1159/000236039. [DOI] [PubMed] [Google Scholar]
- 2. Mendrinos E, Shaarawy T. The current situation in nonpenetrating glaucoma surgery. European Ophthalmic Review. 2009;2(1):35–38. [Google Scholar]
- 3. Rulli E, Biagioli E, Riva I, Gambirasio G, De Simone I, Floriani I, Quaranta L. Efficacy and safety of trabeculectomy vs nonpenetrating surgical procedures: a systematic review and meta-analysis. JAMA Ophthalmol. 2013 Dec;131(12):1573–1582. doi: 10.1001/jamaophthalmol.2013.5059. [DOI] [PubMed] [Google Scholar]
- 4. Leszczynski R, Forminska-Kapuscik M, Bubala-Stachowicz B, Mrukwa-Kominek E, Filipek E, Pawlicki K. Nonpenetrating very deep sclerectomy with hyaluronic acid implant vs trabeculectomy-a 2-year follow-up. Graefes Arch Clin Exp Ophthalmol. 2012 Dec;250(12):1835–1841. doi: 10.1007/s00417-012-1985-9. [DOI] [PubMed] [Google Scholar]
- 5. Mesci C, Erbil HH, Karakurt Y. Akχakaya AA. Deep sclerectomy augmented with combination of absorbable biosynthetic sodium hyaluronate scleral implant and mitomycin C or with mitomycin C versus trabeculectomy: long-term results. Clin Experiment Ophthalmol. 2012 May-Jun;40(4):e197–e207. doi: 10.1111/j.1442-9071.2011.02611.x. [DOI] [PubMed] [Google Scholar]
- 6. Russo V, Scott IU, Stella A, Balducci F, Cosma A, Barone A, Delle Noci N. Nonpenetrating deep sclerectomy with reticulated hyaluronic acid implant versus punch trabeculectomy: a prospective clinical trial. Eur J Ophthalmol. 2008 Sep-Oct;18(5):751–757. doi: 10.1177/112067210801800515. [DOI] [PubMed] [Google Scholar]
- 7. Cillino S, Di Pace F, Casuccio A, Cillino G, Lodato G. Deep sclerectomy versus trabeculectomy with low-dosage mitomycin C: four-year follow-up. Ophthalmologica. 2008;222(2):81–87. doi: 10.1159/000112623. [DOI] [PubMed] [Google Scholar]
- 8. Eldaly MA, Bunce C, Elsheikha OZ, Wormald R. Non-penetrating filtration surgery versus trabeculectomy for open-angle glaucoma. Cochrane Database Syst Rev. 2014 Feb;15(2):CD007059. doi: 10.1002/14651858.CD007059.pub2. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 9.AIGS Investigators. The Advanced Glaucoma Intervention Study: 8. Risk of cataract formation after trabeculectomy. Arch Ophthalmol. 2001;119(12):1771–1779. doi: 10.1001/archopht.119.12.1771. [DOI] [PubMed] [Google Scholar]
- 10. Roy S, Mermoud A. Complications de la sclerectomie profonde non perforante [Complications of deep nonpenetrating sclerectomy]. J Fr Ophtalmol. 2006 Dec;29(10):1180–1197. doi: 10.1016/s0181-5512(06)73918-3. [DOI] [PubMed] [Google Scholar]
- 11. Arnavielle S, Lafontaine PO, Bidot S, Creuzot-Garcher C, D’Athis P, Bron AM. Corneal endothelial cell changes after trabeculectomy and deep sclerectomy. J Glaucoma. 2007 May;16(3):324–328. doi: 10.1097/IJG.0b013e3180391a04. [DOI] [PubMed] [Google Scholar]
- 12. Chiselita D. Non-penetrating deep sclerectomy versus trabeculectomy in primary open-angle glaucoma surgery. Eye(Lond) 2001 Apr;15(Pt 2):197–201. doi: 10.1038/eye.2001.60. [DOI] [PubMed] [Google Scholar]
- 13. El Sayyad F, Helal M, El-Kholify H, Khalil M, El-Maghraby A. Nonpenetrating deep sclerectomy versus trabeculectomy in bilateral primary open angle glaucoma. Ophthalmology. 2000 Sep;107(9):1671–1674. doi: 10.1016/s0161-6420(00)00263-3. [DOI] [PubMed] [Google Scholar]
- 14. Mermoud A, Schnyder CC, Sickenberg M, Chiou AG, Hediguer SE, Faggioni R. Comparison of deep sclerectomy with collagen implant and trabeculectomy in open-angle glaucoma. J Cataract Refract Surg. 1999 Mar;25(3):323–331. doi: 10.1016/s0886-3350(99)80079-0. [DOI] [PubMed] [Google Scholar]
- 15. Ramos JL, Li Y, Huang D. Clinical and research applications of anterior segment optical coherence tomography―a review. Clin Experiment Ophthalmol. 2009 Jan;37(1):81–89. doi: 10.1111/j.1442-9071.2008.01823.x. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 16. Konstantopoulos A, Yadegarfar ME, Yadegarfar G, Stinghe A, Macleod A, Jacob A, Hossain P. Deep sclerectomy versus trabeculectomy: a morphological study with anterior segment optical coherence tomography. Br J Ophthalmol. 2013 Jun;97(6):708–714. doi: 10.1136/bjophthalmol-2012-301926. [DOI] [PubMed] [Google Scholar]
- 17. Labbe A, Hamard P, Iordanidou V, Dupont-Monod S, Baudouin C. Utility of the Visante OCT in the follow-up of glaucoma surgery. J Fr Ophthalmol. 2007 Mar;30(3):225–231.(Fren). doi: 10.1016/s0181-5512(07)89582-9. [DOI] [PubMed] [Google Scholar]
- 18. Singh M, Chew PT, Friedman DS, Nolan WP, See JL, Smith SD, Zheng C, Foster PJ, Aung T. Imaging of trabeculectomy blebs using anterior segment optical coherence tomography. Ophthalmology. 2007 Jan;114(1):47–53. doi: 10.1016/j.ophtha.2006.05.078. [DOI] [PubMed] [Google Scholar]
- 19. Park HY, Ahn MD. Imaging of trabeculectomy blebs with Visante anterior segment optical coherence tomography after digital ocular compression. Jpn J Ophthalmol. 2012 Jan;56(1):38–45. doi: 10.1007/s10384-011-0101-8. [DOI] [PubMed] [Google Scholar]
- 20. Aptel F, Dumas S, Denis P. Ultrasound biomicroscopy and optical coherence tomography imaging of filtering blebs after deep sclerectomy with new collagen implant. Eur J Ophthalmol. 2009 Mar-Apr;19(2):223–230. doi: 10.1177/112067210901900208. [DOI] [PubMed] [Google Scholar]
- 21. Mavrakanas N, Mendrinos E, Shaarawy T. Postoperative IOP is related to intrascleral bleb height in eyes with clinically fllat blebs following deep sclerectomy with collagen implant and mitomycin. Br J Ophthalmol. 2010 Apr;94(4):410–413. doi: 10.1136/bjo.2008.150318. [DOI] [PubMed] [Google Scholar]
- 22. Fernandez-Buenaga R, Rebolleda G, Casas-Llera P, Munoz-Negrete FJ, Perez-Lopez M. A comparison of intrascleral bleb height by anterior segment OCT using three different implants in deep sclerectomy. Eye (Lond) 2012 Apr;26(4):552–556. doi: 10.1038/eye.2011.358. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 23. Chihara E, Hayashi K. Relation between the volume of the lake and intraocular pressure reduction after nonfiltering glaucoma surgery: a spectral-domain anterior segment optical coherence tomography study. J Glaucoma. 2011 Oct;20(8):497–501. doi: 10.1097/IJG.0b013e3181f4649f. [DOI] [PubMed] [Google Scholar]
- 24. Ciancaglini M, Carpineto P, Agnifili L, Nubile M, Lanzini M, Fasanella V, Mastropasqua L. Filtering bleb functionality: a clinical, anterior segment optical coherence tomography and in vivo confocal microscopy study. J Glaucoma. 2008 Jun-Jul;17(4):308–317. doi: 10.1097/IJG.0b013e31815c3a19. [DOI] [PubMed] [Google Scholar]
- 25. Hamard P, Sourdille P, Valtot F, Baudouin C. Evaluation of confocal microscopy in the analysis of the external trabecular membrane during deep nonpenetrating sclerectomy. J Fr Ophthalmol. 2001 Jan;24(1):29–35. [PubMed] [Google Scholar]