Skip to main content
Journal of Clinical Pathology logoLink to Journal of Clinical Pathology
. 1974 Sep;27(9):751–756. doi: 10.1136/jcp.27.9.751

Collimation and surface counting in haematology

C S Bowring 1, H I Glass 1
PMCID: PMC475466  PMID: 4426984

Abstract

The effect on the results obtained in surface counting investigations of using a dual detector counting system and multihole collimators has been investigated. The use of the additional detector results in smoother curves for the uptake of the radionuclide and the use of multihole collimators increases the discrimination of the counting system against the effects of radioactivity outside the region of interest. In a clinical trial to compare multihole collimation with conventional single hole collimation it was found that increased excess counts were obtained over the spleen with the multihole collimators in eight of ten cases.

Full text

PDF
751

Images in this article

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. CROOK A., SZUR L. A simple method for the in vivo discrimination of chromium 51 and iron 59. Br J Radiol. 1960 Jul;33:447–450. doi: 10.1259/0007-1285-33-391-447. [DOI] [PubMed] [Google Scholar]
  2. HUGHES JONES N. C., SZUR L. Determination of the sites of red-cell destruction using 51Cr-labelled cells. Br J Haematol. 1957 Jul;3(3):320–331. doi: 10.1111/j.1365-2141.1957.tb05802.x. [DOI] [PubMed] [Google Scholar]
  3. JANDL J. H., GREENBERG M. S., YONEMOTO R. H., CASTLE W. B. Clinical determination of the sites of red cell sequestration in hemolytic anemias. J Clin Invest. 1956 Aug;35(8):842–867. doi: 10.1172/JCI103338. [DOI] [PMC free article] [PubMed] [Google Scholar]
  4. LEWIS S. M., SZUR L., DACIE J. V. The pattern of erythrocyte destruction in haemolytic anaemia, as studied with radioactive chromium. Br J Haematol. 1960 Apr;6:122–139. doi: 10.1111/j.1365-2141.1960.tb06224.x. [DOI] [PubMed] [Google Scholar]
  5. Simons H. A. A computer method for calculation of the point source response of a focusing collimator. Phys Med Biol. 1970 Jan;15(1):57–70. doi: 10.1088/0031-9155/15/1/002. [DOI] [PubMed] [Google Scholar]
  6. Szur L., Glass H. I., Lewis S. M., Grammaticos P., de Garreta A. C., Fisicas C. S. Quantitative estimation of red-cell uptake in the spleen using 81Rb- and 51Cr-labelled red cells. Br J Radiol. 1968 Nov;41(491):819–825. doi: 10.1259/0007-1285-41-491-819. [DOI] [PubMed] [Google Scholar]
  7. Szur L. Surface counting in the assessment of sites of red cell destruction. Br J Haematol. 1970 Jun;18(6):591–596. doi: 10.1111/j.1365-2141.1970.tb01583.x. [DOI] [PubMed] [Google Scholar]
  8. Williams E. D., Szur L., Glass H. I., Lewis S. M., Pettit J. E., Ahuja S. Measurement of red cell destruction in the spleen. J Lab Clin Med. 1974 Jul;84(1):134–146. [PubMed] [Google Scholar]

Articles from Journal of Clinical Pathology are provided here courtesy of BMJ Publishing Group

RESOURCES