Skip to main content
Frontiers in Oncology logoLink to Frontiers in Oncology
. 2016 Feb 18;6:32. doi: 10.3389/fonc.2016.00032

Corrigendum: A Simpler Energy Transfer Efficiency Model to Predict Relative Biological Effect for Protons and Heavier Ions

Bleddyn Jones 1,*
PMCID: PMC4757668  PMID: 26925387

An error was caused by inaccurate transcription of one equation from the computer programmes in the above paper (1). On page 4 of the above article, in the paragraph before Eq. 9, the biological ‘inefficiency’ should be expressed by (LETx − LETU)/(LETx − LETC), that is the local energy deposition (LETx) in excess of the maximum efficiency energy deposition (LETU), divided by the local energy deposition that exceeds that imparted by the control radiation (LETC).

This means that Eq. 9 should be modified to be:

αH=αL+(1LETxLETULETxLETC)(αUαL)

The author apologises for this error, although is pleased to state that the graphical displays were all achieved using the correct equation as given above.

Conflict of Interest Statement

The author declares that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

Reference

  • 1.Jones BA. Simpler energy transfer efficiency model to predict relative biological effect for protons and heavier ions. Front Oncol (2015) 5:184. 10.3389/fonc.2015.00184 [DOI] [PMC free article] [PubMed] [Google Scholar]

Articles from Frontiers in Oncology are provided here courtesy of Frontiers Media SA

RESOURCES