. 1976 Apr;29(4):317–321. doi: 10.1136/jcp.29.4.317

Evaluation of automated large-scale screening tests for syphilis.

D E Macfarlane, K Hare, T F Elias-Jones
PMCID: PMC476055  PMID: 777045

Abstract

Two methods of performing serological screening tests for syphilis are compared. One consisted of the Venereal Diseases Reference Laboratory (VDRL) slide test, the cardiolipin Wassermann reaction (CWR), and the Reiter protein complement fixation test (RPCFT) performed manually; the other was a fully automated system using two Technicon AutoAnalyzers (AAII), one for the automated reagin test (ART) and the other for automated complement fixation tests. The absorbed fluorescent treponemal antibody test (FTA-ABS) was used as a final arbiter in all cases found to be seropositive by either method. A pooled antigen consisting of a mixture of cardiolipin and Reiter protein was used for the automated complement fixation test, thus increasing the scope and capacity of the system. The AutoAnalyzer was shown to be capable of performing 400 cardiolipin and Reiter complement fixation tests and 700 automated reagin tests in an 8-hour day. Modification of the complement fixation test method to take advantage of the highly sensitive colorimeter resulted in a significant increase in sensitivity and a corresponding saving in reagents. Of the 7843 sera tested, 258 gave a positive result in one or more of the screening tests. The automated test detected many more Reiter positive sera (127) than the manual test (83). Conversely, fewer CWR positive sera were detected by the automated test (60) than by the manual test (82). There was little difference between the number of positive sera detected by the ART (73) and the VDRL slide test (71). In 19 instances the automated tests detected positive sera which registered as completely negative in the manual tests, and four seropositive cases which the automated tests had failed to detect were detected by the manual tests, and four seropositive cases which the automated tests had failed to detect were detected by the manual tests. It was concluded that a combination of the ART and automated Reiter protein complement fixation test (ARPCFT) would be ideal for use in a large-scale screening programme for the detection of syphilis.

Full text

PDF
317

Images in this article

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. McGrew B. E., DuCros M. J., Stout G. W., Falcone V. H. Automation of a flocculation test for syphilis. Am J Clin Pathol. 1968 Jul;50(1):52–59. doi: 10.1093/ajcp/50.1.52. [DOI] [PubMed] [Google Scholar]
  2. Pugh V. W., Gaze R. W. The Reiter protein complement-fixation test using the Auto-Analyzer. J Clin Pathol. 1966 Nov;19(6):595–599. doi: 10.1136/jcp.19.6.595. [DOI] [PMC free article] [PubMed] [Google Scholar]
  3. SEQUEIRA P. J. Serology of the venereal diseases. Br J Vener Dis. 1962 Mar;38:9–18. doi: 10.1136/sti.38.1.9. [DOI] [PMC free article] [PubMed] [Google Scholar]
  4. Schofield C. B. Serological tests for syphilis in pregnancy. False and missed positive reactions. Br J Vener Dis. 1973 Oct;49(5):420–426. doi: 10.1136/sti.49.5.420. [DOI] [PMC free article] [PubMed] [Google Scholar]
  5. Wagstaff W., Firth R., Booth J. R., Bowley C. C. Large-scale screening by the automated Wassermann reaction. J Clin Pathol. 1969 Mar;22(2):236–239. doi: 10.1136/jcp.22.2.236. [DOI] [PMC free article] [PubMed] [Google Scholar]
  6. Wilkinson A. E., Scrimgeour G., Rodin P. A comparison of the absorbed fluorescent treponemal antibody (FTA-ABS) test and other screening tests for treponemal disease in patients attending a venereal disease clinic. J Clin Pathol. 1972 May;25(5):437–440. doi: 10.1136/jcp.25.5.437. [DOI] [PMC free article] [PubMed] [Google Scholar]

Articles from Journal of Clinical Pathology are provided here courtesy of BMJ Publishing Group

RESOURCES