Abstract
Red cell anisocytosis as assessed using the Coulter Channelyzer C-1000 showed an increase with progressive anaemia in 25 patients with macrocytosis due to B12 and/or folate deficiency. In deficiency of a single factor, the degree of anisocytosis increased with progressive anaemia. In five cases with B12 and folate deficiency combined, anisocytosis was markedly increased out of proportion to the degree of anaemia present. Iron stores were also reduced in four of these cases. It is suggested that objective measurement of anisocytosis is of early diagnostic value in the assessment of multiple haematinic factor deficiency, for example, in macrocytic anaemia associated with malabsorption states and unexpected multiple deficiency states.
Full text
PDF




Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Bentley S. A., Lewis S. M. The use of an image analysing computer for the quantitation of red cell morphological characteristics. Br J Haematol. 1975 Jan;29(1):81–88. doi: 10.1111/j.1365-2141.1975.tb01801.x. [DOI] [PubMed] [Google Scholar]
- Bessman J. D., Johnson R. K. Erythrocyte volume distribution in normal and abnormal subjects. Blood. 1975 Sep;46(3):369–379. [PubMed] [Google Scholar]
- Britt R. P., Bolton F. G., Cull A. C., Spray G. H. Experience with a simplified method of radio-isotopic assay of serum vitamin B 12. Br J Haematol. 1969 May;16(5):457–464. doi: 10.1111/j.1365-2141.1969.tb00424.x. [DOI] [PubMed] [Google Scholar]
- England J. M., Down M. C. Red-cell-volume distribution curves and the measurement of anisocytosis. Lancet. 1974 Apr 20;1(7860):701–703. doi: 10.1016/s0140-6736(74)92904-3. [DOI] [PubMed] [Google Scholar]
- Herbert V. Aseptic addition method for Lactobacillus casei assay of folate activity in human serum. J Clin Pathol. 1966 Jan;19(1):12–16. doi: 10.1136/jcp.19.1.12. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Hughes-Jones N. C., Norley I., Young J. M., England J. M. Differential white cell counts by frequency distribution analysis of cell volumes. J Clin Pathol. 1974 Aug;27(8):623–625. doi: 10.1136/jcp.27.8.623. [DOI] [PMC free article] [PubMed] [Google Scholar]
- LUSHBAUGH C. C., MADDY J. A., BASMANN N. J. Electronic measurement of cellular volumes. I. Calibration of the apparatus. Blood. 1962 Aug;20:233–240. [PubMed] [Google Scholar]
- Ur A., Lushbaugh C. C. Some effects of electrical fields on red blood cells with remarks on electronic red cell sizing. Br J Haematol. 1968 Dec;15(6):527–538. doi: 10.1111/j.1365-2141.1968.tb01575.x. [DOI] [PubMed] [Google Scholar]
- van der Wal G. A modified method for the determination of total iron binding capacity. Clin Chim Acta. 1972 Feb;36(2):570–571. doi: 10.1016/0009-8981(72)90038-1. [DOI] [PubMed] [Google Scholar]