Skip to main content
Journal of Clinical Pathology logoLink to Journal of Clinical Pathology
. 1976 Dec;29(12):1101–1104. doi: 10.1136/jcp.29.12.1101

A modified rubella HI test using prestandardized reagents.

G E Urquhart, D A Worswick, N R Grist
PMCID: PMC476311  PMID: 1010879

Abstract

A modified haemagglutination inhibition test for rubella antibodies using prestandardized freeze-dried reagents was compared to a "standard" method. Tests of 707 serum samples showed that the modified test was sensitive and reliable by both macrotitration and microtitration techniques. The minor disadvantages of some reduction in antibody level when rubella sera were tested within one week of the rash and of spontaneous sheep erythrocyte agglutination in 0-7% of sera were out-weighed by the increased speed of the new test and the fact that it was carried out at room temperature.

Full text

PDF
1101

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Stewart G. L., Parkman P. D., Hopps H. E., Douglas R. D., Hamilton J. P., Meyer H. M., Jr Rubella-virus hemagglutination-inhibition test. N Engl J Med. 1967 Mar 9;276(10):554–557. doi: 10.1056/NEJM196703092761006. [DOI] [PubMed] [Google Scholar]
  2. van Weemen B., Kacaki J. A modified haemagglutination inhibition test for rubella antibodies, using standardized, freeze-dried reagents. Report of a comparative multi-centre trial. J Hyg (Lond) 1976 Aug;77(1):31–42. doi: 10.1017/s0022172400055480. [DOI] [PMC free article] [PubMed] [Google Scholar]

Articles from Journal of Clinical Pathology are provided here courtesy of BMJ Publishing Group