Abstract
The apparent volumes of distribution of Evans blue and 59Fe-dextran were determined in 18 studies.
59Fe-dextran volume was 5% lower than Evans blue volume, a highly significant difference.
The rate of loss of 59Fe dextran from the circulation was significantly less than that of Evans blue.
Full text
PDF




Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- ANDERSEN S. B., GABUZDA T. G. SIMULTANEOUS DETERMINATION OF PLASMA VOLUME WITH T-1824 AND 131-I-LABELLED AUTOLOGOUS AND HOMOLOGOUS PARAPROTEIN. Clin Sci. 1964 Feb;26:41–45. [PubMed] [Google Scholar]
- ANDERSEN S. B. Simultaneous determination of plasma volume with 131-I-labelled gamma-globulin, 131-I-labelled albumin and T-1824. Clin Sci. 1962 Oct;23:221–228. [PubMed] [Google Scholar]
- Andersen S. B., Jarnum S. Gastrointestinal protein loss measured with 59Fe-labelled iron-dextran. Lancet. 1966 May 14;1(7446):1060–1062. doi: 10.1016/s0140-6736(66)91008-7. [DOI] [PubMed] [Google Scholar]
- BAKER C. H., WYCOFF H. D. Time-concentration curves and dilution spaces of T-1824 and I-1824 and I-131-labeled proteins in dogs. Am J Physiol. 1961 Dec;201:1159–1163. doi: 10.1152/ajplegacy.1961.201.6.1159. [DOI] [PubMed] [Google Scholar]
- COOLEY G. Some observations on impurities present in samples of Evan's blue (T 1824) and their influence on blood-volume determinations effected by the dye method. J Physiol. 1954 Jan;123(1):16–21. doi: 10.1113/jphysiol.1954.sp005030. [DOI] [PMC free article] [PubMed] [Google Scholar]
- JAENIKE J. R., SCHREINER B. F., Jr, WATERHOUSE C. The relative volumes of distribution of I131-tagged albumin and high molecular weight dextran in normal subjects and patients with heart disease. J Lab Clin Med. 1957 Feb;49(2):172–181. [PubMed] [Google Scholar]
- JARNUM S. A new diagnostic test in amyloidosis. Lancet. 1960 May 7;1(7132):1007–1008. doi: 10.1016/s0140-6736(60)90891-6. [DOI] [PubMed] [Google Scholar]
- LEESON D., REEVE E. B. A method for testing the purity of commercial samples of T 1824 with observations on the amounts of colored impurities present and the errors in plasma volume estimation caused by them. J Physiol. 1949 Aug;109(1-2):170–176. doi: 10.1113/jphysiol.1949.sp004382. [DOI] [PMC free article] [PubMed] [Google Scholar]
- MACKENZIE A., TINDLE J. Determination of plasma-volume using intravenous iron dextran. Lancet. 1959 Feb 14;1(7068):333–335. doi: 10.1016/s0140-6736(59)90313-7. [DOI] [PubMed] [Google Scholar]
- MILLS I. H., DE WARDENER H. E., HAYTER C. J., CLAPHAM W. F. Studies on the afferent mechanism of the sodium chloride diuresis which follows intravenous saline in the dog. Clin Sci. 1961 Oct;21:259–264. [PubMed] [Google Scholar]
- POSEN S., CLUBB J. S., NEALE F. C., HOTCHKIS D. THE MEASUREMENT OF PLASMA VOLUME BY ENZYME DILUTION. J Lab Clin Med. 1965 Mar;65:530–538. [PubMed] [Google Scholar]
- Ricketts C. R., Cox J. S., Fitzmaurice C., Moss G. F. The iron-dextran complex. Nature. 1965 Oct 16;208(5007):237–239. doi: 10.1038/208237a0. [DOI] [PubMed] [Google Scholar]
- SCHULTZ A. L., HAMMARSTEN J. F., HELLER B. I., EBERT R. V. A critical comparison of the T-1824 dye and iodinated albumin methods for plasma volume measurement. J Clin Invest. 1953 Feb;32(2):107–112. doi: 10.1172/JCI102717. [DOI] [PMC free article] [PubMed] [Google Scholar]
- SEMPLE R. E., THOMSEN A. E., BALL A. J. Description and evaluation of a dextran-dilution technique for the determination of plasma volume in the dog and man. Clin Sci. 1958 Aug;17(3):511–518. [PubMed] [Google Scholar]
- VEREL D. Simultaneous measurement of plasma volume with dextran and Evans Blue: evidence for increased vascular permeability in oedema and infection. Clin Sci. 1958 Nov;17(4):639–646. [PubMed] [Google Scholar]