Abstract
A method is described using Triton X-100 scintillant to simplify liquid scintillation counting of 55Fe alone or in combination with 59Fe. The Triton acts as an efficient solubilizing agent allowing small volumes of aqueous solutions of iron compounds in hydrochloric acid to be counted. The efficiencies achieved are comparable with those of previously described methods whilst the technique is less time-consuming and the scintillant-aqueous mixture is stable at low temperatures. Reproducible quantitative recovery of radioactivity has been obtained.
Full text
PDF![304](https://cdn.ncbi.nlm.nih.gov/pmc/blobs/cd93/476748/344054ff8d99/jclinpath00084-0024.png)
![305](https://cdn.ncbi.nlm.nih.gov/pmc/blobs/cd93/476748/dac161d01ccd/jclinpath00084-0025.png)
![306](https://cdn.ncbi.nlm.nih.gov/pmc/blobs/cd93/476748/87daa22254d5/jclinpath00084-0026.png)
![307](https://cdn.ncbi.nlm.nih.gov/pmc/blobs/cd93/476748/e37cadd53c88/jclinpath00084-0027.png)
![308](https://cdn.ncbi.nlm.nih.gov/pmc/blobs/cd93/476748/42ba2dbb2967/jclinpath00084-0028.png)
Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- DERN R. J., HART W. L. Studies with doubly labeled iron. I. Simultaneous liquid scintillation counting of isotopes Fe55 and Fe59 as ferrous perchlorate. J Lab Clin Med. 1961 Feb;57:322–330. [PubMed] [Google Scholar]
- Eakins J. D., Brown D. A. An improved method for the simultaneous determination of iron-55 and iron-59 in blood by liquid scintillation counting. Int J Appl Radiat Isot. 1966 Jul;17(7):391–397. doi: 10.1016/0020-708x(66)90065-2. [DOI] [PubMed] [Google Scholar]
- Graber S. E., McKee L. C., Heyssel R. M. The use of benzene phosphinic acid to prepare mixed samples of 55Fe and 59Fe for liquid scintillation counting. J Lab Clin Med. 1967 Jan;69(1):170–176. [PubMed] [Google Scholar]
- HALLBERG L., BRISE H. Determination of Fe55 and Fe59 in blood. Int J Appl Radiat Isot. 1960 Dec;9:100–108. doi: 10.1016/0020-708x(60)90014-4. [DOI] [PubMed] [Google Scholar]
- KATZ J. H., ZOUKIS M., HART W. L., DERN R. J. A SIMPLIFIED PROCEDURE FOR THE SIMULTANEOUS ASSAY OF FE55 AND FE59 IN A LIQUID SCINTILLATION SYSTEM. J Lab Clin Med. 1964 May;63:885–893. [PubMed] [Google Scholar]
- PATTERSON M. S., GREENE R. C. MEASUREMENT OF LOW ENERGY BETA-EMITTERS IN AQUEOUS SOLUTION BY LIQUID SCINTILLATION COUNTING OF EMULSIONS. Anal Chem. 1965 Jun;37:854–857. doi: 10.1021/ac60226a017. [DOI] [PubMed] [Google Scholar]
- PERRY S. W., WARNER G. T. A METHOD OF SAMPLE PREPARATION FOR THE ESTIMATION OF FE55 IN WHOLE BLOOD BY THE LIQUID SCINTILLATION COUNTING TECHNIQUE. Int J Appl Radiat Isot. 1963 Sep;14:397–400. doi: 10.1016/0020-708x(63)90020-6. [DOI] [PubMed] [Google Scholar]
- Peacock W. C., Evans R. D., Irvine J. W., Good W. M., Kip A. F., Weiss S., Gibson J. G. THE USE OF TWO RADIOACTIVE ISOTOPES OF IRON IN TRACER STUDIES OF ERYTHROCYTES. J Clin Invest. 1946 Jul;25(4):605–615. doi: 10.1172/JCI101743. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Pitcher C. S., Williams H. S., Parsonson A., Williams R. The measurement of iron absorption by the double isotope technique. Br J Haematol. 1965 Nov;11(6):633–641. doi: 10.1111/j.1365-2141.1965.tb00111.x. [DOI] [PubMed] [Google Scholar]
- Turner J. C. Triton X-100 scintillant for carbon-14 labelled materials. Int J Appl Radiat Isot. 1968 Jul;19(7):557–563. doi: 10.1016/0020-708x(68)90065-3. [DOI] [PubMed] [Google Scholar]