Diagnostic Performance of Five Assays for Anti-Hepatitis E Virus IgG and IgM in a Large Cohort Study

Heléne Norder a,, Marie Karlsson a, Åsa Mellgren b, Jan Konar c, Elisabeth Sandberg a, Anders Lasson d, Maria Castedal e, Lars Magnius f, Martin Lagging a
Editor: Y-W Tang
PMCID: PMC4767966  PMID: 26659210

Abstract

Determination of anti-hepatitis E virus (anti-HEV) antibodies is still enigmatic. There is no gold standard, and results obtained with different assays often diverge. Herein, five assays were compared for detection of anti-HEV IgM and IgG. Serum samples from 500 Swedish blood donors and 316 patients, of whom 136 had suspected HEV infection, were analyzed. Concordant results for IgM and IgG with all assays were obtained only for 71% and 70% of patients with suspected hepatitis E, respectively. The range of sensitivity for anti-HEV detection was broad (42% to 96%); this was reflected in the detection limit, which varied up to 19-fold for IgM and 17-fold for IgG between assays. HEV RNA was analyzed in all patients and in those blood donors reactive for anti-HEV in any assay, and it was found in 26 individuals. Among all of the assays, both anti-HEV IgG and IgM were detected in 10 of those individuals. Twelve had only IgG and, in 7 of those 12, IgG was only detected with the two most sensitive assays. Three of the HEV-RNA-positive samples were negative for anti-HEV IgM and IgG in all assays. With the two most sensitive assays, anti-HEV IgG was identified in 16% of the blood donor samples and in 66% of patients with suspected HEV infection. Because several HEV-RNA-positive samples had only anti-HEV IgG without anti-HEV IgM or lacked anti-HEV antibodies, analysis for HEV RNA may be warranted as a complement in the laboratory diagnosis of ongoing HEV infection.

INTRODUCTION

Hepatitis E virus (HEV) is transmitted via the fecal-oral route and, globally, is a frequent cause of acute hepatitis. HEV is classified into the Hepeviridae family within the genera Orthohepevirus. Orthohepevirus consists of four species, A through D, infecting mammals and chickens, and Piscihepevirus infects trout (1). Four out of seven genotypes of Orthohepevirus A are known to infect humans, and genotypes 1 and 2 are endemic in Asia and Africa causing large recurrent outbreaks. Genotype 3 is endemic in Europe, Japan, and the United States. Infection by direct or indirect contact with living animals or with food products contaminated with HEV is probably the most common route of infection with this genotype, but blood transmissions also occur (2).

Hepatitis E virus infection is usually mild or asymptomatic without sequelae, and less than 5% of exposed individuals develop hepatitis (35). However, fulminant infection sporadically occurs, and in some patients, chronic infection may ensue, often with rapid fibrosis progression leading to cirrhosis; this most commonly occurs in immunocompromised individuals, such as solid organ recipients and patients receiving chemotherapy (611). Additionally, hepatitis E may be associated with neurological manifestations, such as Guillain-Barré syndrome (12), neuralgic amyotrophy (13), and meningitis (14, 15).

Acute, chronic, and past HEV infection can be diagnosed by immunoassays for detection of anti-HEV IgM and IgG in serum as well as by assays for HEV RNA (16). Despite improvements to the assays, their specificities have been difficult to determine, and several studies have evaluated up to seven different assays with anti-HEV serum panels from immunocompetent and immunocompromised patients (1723). However, many issues remain unresolved regarding the sensitivity and specificity of these assays, and the confirmatory immunoblot is reported unreliable (24). Not surprisingly, discordant results are reported regarding anti-HEV seroprevalence (25, 26).

In the present study, the performances of five commercial assays for the detection of anti-HEV IgM and IgG were compared in a clinical setting using samples from blood donors and patients with liver disease.

MATERIALS AND METHODS

Serum samples.

Serum samples from 500 Swedish blood donors sampled at the Department of Transfusion Medicine at Sahlgrenska University Hospital, Gothenburg in 2012 were evaluated. The samples were anonymized with only gender and age known. Another 137 serum samples were derived from patients with suspected hepatitis E that was based on negativity for markers indicative of ongoing hepatitis A, B, or C, who were hospitalized or attending outpatient clinics throughout Sweden. Serum samples from these patients were sent to the Department of Clinical Microbiology/Virology at Sahlgrenska University Hospital, which is the Swedish referral laboratory for hepatitis E. Another 156 patients had liver disease with other etiologies and were attending the Department of Infectious Diseases or the Department of Internal Medicine at Södra Älvsborgs Hospital in Borås. Serum samples from 23 patients who had undergone liver transplantation at the Transplant Institute at Sahlgrenska University Hospital were also investigated. One to three additional serum samples from 27 patients sampled 1 month to 5 years apart were also analyzed. All serum samples were analyzed at the Department of Clinical Microbiology/Virology. All patients presented with liver disease, and the liver transplant recipients had given their consent to participate in the study, which was approved by the Regional Ethical Review Board in Gothenburg (registration number 737-12).

Enzyme-linked immunosorbent assays.

Five commercial assays were used for anti-HEV IgM and IgG detection in the 851 samples. The assays were selected based on routine use in the laboratory and on availability and prior publications (1720). The selected assays were as follows: (i) recomWell HEV IgG/IgM (Mikrogen Diagnostik, Neuried, Germany), (ii) DS-EIA-ANTI-HEV-G/M (DSI Srl, Milan, Italy), (iii) Anti-Hepatitis E Virus (HEV) ELISA (IgG/IgM) (Euroimmun, Lübeck, Germany), (iv) HEV Ab/HEV IgM EIA (Axiom Diagnostics, Worms, Germany), and (v) HEV IgM/HEV IgG (DiaPro, Milan, Italy). DS-EIA corresponds to an assay produced by RPC Diagnostic Systems (Nizhny Novgorod, Russia), and the Axiom assay corresponds to an assay produced by Wantai (Beijing, China). The formats of the assays are given in Table 1. All serum samples were kept frozen at −20°C until tested for anti-HEV IgM and IgG in parallel. The cutoff of each assay was calculated according to the manufacturer's instructions, and the optical density (OD) value for each sample was divided by the cutoff value of the assay (sample OD/cutoff OD of the assay). All samples with OD values above or at the cutoff were reanalyzed in duplicate for that particular assay, and the reactivity of the sample was determined by the mean OD value of the reanalyzed duplicates. Due to the highly different numbers of anti-HEV IgG-reactive samples in different assays, the cutoff values were analyzed with the receiver operating characteristic (ROC) curve using GraphPad Prism version 6.04 (GraphPad Software Inc., CA, USA).

TABLE 1.

Antigens used for coating and systems used for anti-HEV detection in the different assays

Assay Antigen for coating Detection
Mikrogen Recombinant partial ORF2 and ORF3 genotypes 1 and 3 Labeled anti-human IgG or IgM antibodies
DSI Recombinant ORF2 and ORF3 peptides cross neutralizing genotypes 1, 2, and 3 Labeled mouse anti-human IgG or IgM antibodies
Euroimmun Mixture of recombinant partial ORF2 genotype 1 and 3 antigens Labeled rabbit anti-human IgG or IgM antibodies
Axiom IgG Recombinant carboxy terminal of ORF2 genotype 1 Burmese strain Labeled second recombinant ORF 2 antigens
Axiom IgM Anti-human IgM antibodies Labeled recombinant ORF 2 antigens
DiaPro Four synthetic peptides with conservative epitopes of ORF2 and ORF3 in genotypes 1, 2, 3, and 4 Labeled goat anti-human IgG or IgM

To determine the detection limit, serial two-step dilutions (from 1/2 to 1/64) of the WHO reference reagent for hepatitis E virus (National Institute for Biological Standards and Control [NIBSC] code 95/584 [27]) containing 100 IU/ml anti-HEV IgG and IgM were performed in anti-HEV and HEV-RNA-negative serum. Two serum samples that were positive for anti-HEV IgM and IgG in all assays were also diluted in negative serum. Each dilution was divided into six aliquots, and these were frozen at −20°C and thawed only once before being analyzed in duplicate. For determination of endpoint titers, linear regression was performed on the log(mean OD/cutoff OD) of each dilution versus the log(dilution of the sample) using the GraphPad Prism program.

HEV RNA detection by real-time PCR.

All blood donor samples that were reactive for anti-HEV IgG and/or IgM in any assay and all patient samples were analyzed for HEV RNA. The RNA was extracted from a 250-μl serum sample mixed with 2 ml lysis buffer (NucliSENS easyMag; bioMérieux SA, France). The mixture was incubated for 10 min at room temperature before the addition of 50 μl of NucliSENS easyMag magnetic silica and was incubated for an additional 10 min. RNA was eluted in 110 μl distilled water by using the NucliSENS easyMag instrument according to the manufacturer's instructions (bioMérieux SA, France).

Real-time PCR was performed on 20 μl extracted RNA in 30 μl master mix consisting of 25 μl 2× reaction mix with ROX, 1 μl SuperScript III RT/Platinum Taq mix, 1 μl RNaseOUT (Invitrogen), and 200 nM each of the forward primer (JVHEVF), reverse primer (JVHEVR), and probe (HEVP). Cycling conditions were performed as previously described (28).

Statistical analysis.

All statistical analyses were performed using the GraphPad Prism version 6.04 (GraphPad software Inc., CA, USA). Specificity and sensitivity of the assays were calculated according to Baratloo et al. (29).

RESULTS

There were considerable differences in reactivity when using the recommended cutoffs at the initial testing of the material. The highest reactivity was obtained using DiaPro with 49 serum samples that were reactive for anti-HEV IgM and 255 samples that were reactive for anti-HEV IgG. The lowest reactivity was noted with Euroimmun, with 16 and 79 serum samples reactive for anti-HEV IgM and IgG, respectively (see Fig. S1 in the supplemental material). The values of the log(sample OD/cutoff OD of the assay) obtained for each sample and for each patient category from two assays were plotted on a scatter plot, with the values obtained with one assay on the x axis and the values obtained with another assay on the y axis (see Fig. S1). Because the plot of Mikrogen and Euroimmun formed a straight line below the origin, these two assays appeared to have similar reactivity for each sample. However, the cutoff seemed to be set too low for Euroimmun (see Fig. S1). Most samples with low levels of reactivity slightly above the cutoff were obtained with DiaPro. Therefore, all assays were subject to ROC curve analyses, and based on these results, optimal cutoff values of 0.8 for Euroimmun and 1.3 for DiaPro for anti-HEV IgG were found and used in further analyses (see Table S1 in the supplemental material). Otherwise, the recommended cutoffs were used.

After adjustment of the cutoff values, reactivity in two or more assays for the same marker (i.e., anti-HEV IgG or IgM) was considered a specific outcome. Hepatitis E virus infection was also considered confirmed for patients with serum samples reactive for both IgG and IgM with different assays or with positive results in HEV PCR.

Anti-HEV IgM.

Analysis of the dilution series of the WHO reference reagent and two patient serum samples revealed a detection limit from 5.1 to 23.8 IU/ml, with Axiom and DiaPro being the most sensitive (Table 2; see also Fig. S2 in the supplemental material). There was also an up to 19-fold difference in the detection limit for the diluted patient serum samples, with Axiom being the most sensitive followed by DiaPro and DSI (Table 2).

TABLE 2.

Detection limits and endpoint titers obtained from analyzing the dilution series of the WHO reference reagent 95/584 and two patient serum samples in five anti-HEV assays

Reference reagent or patient sample Detection limit for assay:
Mikrogen DSI Euroimmun Axiom DiaPro
Anti-HEV IgM
    WHO 95/584 100 IU/ml (IU/ml) 16 8.5 24 5.1 5.4
    Sample 17176/13 1/53 1/220 1/35 1/270 1/140
    Sample 4290/14 1/43 1/110 1/22 1/420 1/360
Anti-HEV IgG
    WHO 95/584 100 IU/ml (IU/ml) 0.9 0.4 2.2 0.2 0.2
    Sample 17176/13 1/86 1/190 1/27 1/430 1/480
    Sample 4290/14 1/230 1/480 1/130 1/630 1/880

For 749 (92%) of the 816 samples, there were concordant results for anti-HEV IgM with all five assays (see Table S2 in the supplemental material). IgM reactivity was confirmed for 68 of the 80 IgM-reactive samples (85%) by anti-HEV IgM reactivity with more than one assay and/or with anti-HEV IgG or HEV RNA (Table 3). Forty-six of these 68 confirmed anti-HEV IgM samples were from patients with suspected hepatitis E (Table 3). The sensitivity for anti-HEV IgM detection was low and varied from 24% for the Euroimmun assay to 72% for the DiaPro assay.

TABLE 3.

Reactivity for anti-HEV IgG and IgM in respective assays for 66 serum samples confirmed reactive for anti-HEV IgM, 12 of which were positive for HEV RNA, and for 216 serum samples confirmed reactive for anti-HEV IgG, 22 of which were positive for HEV RNA

Assay and reactivity No. HEV IgM (HEV RNA positive) No. HEV IgG (HEV RNA positive) Sensitivity IgM/IgG (%) Specificity IgM/IgG (%)
Mikrogen
    Reactive also in other assay(s) 22 (9) 134 (14) 38 IgM 99 IgM
    Confirmed singly reactive 4a (1) 0 62 IgG 99 IgG
    Not confirmed singly reactive 9 4
DSI
    Reactive also in other assay(s) 33 (9) 156 (14) 63 IgM 99 IgM
    Confirmed singly reactive 10b (1) 1c (0) 72 IgG 99 IgG
    Not confirmed singly reactive 3 3
Euroimmun
    Reactive also in other assay(s) 16 (10) 91 (15) 24 IgM 100 IgM
    Confirmed singly reactive 0 0 42 IgG 99 IgG
    Not confirmed singly reactive 0 4
Axiom
    Reactive also in other assay(s) 19 (10) 203 (22) 29 IgM 99 IgM
    Confirmed singly reactive 1d (0) 3e (0) 95 IgG 98 IgG
    Not confirmed singly reactive 1 9
DiaPro
    Reactive also in other assay(s) 31 (10) 209 (22) 72 IgM 100 IgM
    Confirmed singly reactive 18f (1) 2g (0) 98 IgG 96 IgG
    Not confirmed singly reactive 0 22
a

Four serum samples were reactive for anti-HEV IgG, two with all of the assays and one each with DSI and DiaPro.

b

Ten serum samples were reactive for anti-HEV IgG, five with all of the assays, two with Axiom and DiaPro, two with Axiom only, and one with DiaPro only.

c

One serum sample was positive for anti-HEV IgM with Microgen.

d

One serum sample was positive for anti-HEV IgG with all five assays.

e

Three serum samples were positive for anti-HEV IgM, one with DSI, Axiom, and DiaPro, and two with DSI only.

f

All serum samples were positive for anti-HEV IgG, 17 with all five assays and one with Axiom and DiaPro.

g

Two serum samples were positive for anti-HEV IgM, one with Microgen and one with DSI.

Anti-HEV IgG.

The detection limit for anti-HEV IgG was determined as for anti-HEV IgM and revealed up to 11-fold differences between the assays (from 0.2 to 2.2 IU/ml) and up to 17-fold differences in the endpoint titers of the diluted serum samples, with the Axiom and DiaPro assays being the most sensitive (Table 2).

More samples were reactive for anti-HEV IgG than for IgM. Concordant results were obtained for 644 (79%) of the 816 samples (see Table S3 in the supplemental material). The highest concordance in anti-HEV IgG reactivity was found with the Axiom and DiaPro assays and was 99% for serum samples from patients with suspected hepatitis E and 96% for all serum samples.

There were 216 samples with confirmed anti-HEV IgG reactivity. All 22 HEV-RNA-positive samples with anti-HEV IgG were reactive with Axiom and DiaPro (Table 3). The highest number of anti-HEV IgG singly reactive samples was obtained with DiaPro, with 22 out 235 positive serum samples in just one assay. The lowest reactivity was obtained with Euroimmun, which had 94 reactive samples; 91 of those were confirmed, and 15 of those were confirmed by the presence of HEV RNA. The sensitivity for anti-HEV IgG detection was higher than that for IgM detection and varied from 42% with Euroimmun to 98% with DiaPro (Table 3).

HEV RNA.

Five blood donor samples and 21 patient samples had detectable HEV RNA (Table 4). Ten of these 26 samples were reactive for anti-HEV IgM and IgG in all five assays. For the other 16 HEV-RNA-containing samples, 12 were reactive for anti-HEV IgG. Four of these were reactive for anti-HEV IgG with all five assays, one was reactive with all of the assays except Microgen, and seven were only reactive with Axiom and DiaPro.

TABLE 4.

Summarized results for anti-HEV and HEV RNA for 500 blood donors, 137 patients with suspected hepatitis E, 156 patients with other forms of liver disease, and 23 liver transplant recipientsa

Group No. (%) No. (%) HEV IgM reactive No. (%) HEV IgG reactive No. (%) HEV RNA reactive
Blood donors 500 5 (1)
    Positive for two or more HEV markers or HEV RNA only 81 (16) 13 (2.6) 81 (16) 5
    Reactive in one assay only 29 (6) 4 25 0
    Negative for HEV markers 390 (78)
Suspected hepatitis E 137 16 (12)
    Positive for two or more HEV markers or HEV RNA only 93 (68) 45 (33) 91 (66) 16
    Reactive in one assay only 7 (5.1) 5 2 0
    Negative for HEV markers 37 (27)
Other liver disease 156 3 (2)
    Positive for two or more HEV markers or HEV RNA only 39 (25) 8 (5.1) 38 (24) 3
    Reactive in one assay only 14 (9) 2 12 0
    Negative for HEV markers 103 (66)
Liver transplant recipients 23 2 (9)
    Positive for two or more HEV markers or HEV RNA only 7 (30) 0 6 (26) 2
    Reactive in one assay only 4 (17) 1 3 0
    Negative for HEV markers 12 (53)
Total 816 26 (3)
    Positive for two or more HEV markers or HEV RNA only 220 (27) 66 (8) 216 (26) 26 (3)
    Reactive in one assay only 54 (7) 12 (1.5) 42 (5) 0
    Negative for HEV markers 542 (66)
a

Samples reactive for one of the markers anti-IgG or IgM in more than one assay or only reactive for HEV RNA are regarded as having an acute or as having had a past HEV infection.

Blood donor serum samples.

The mean age of the 500 blood donors was 42 years, 44 years for males (range, 18 to 75) and 41 years for females (range, 19 to 74). The seroprevalence of anti-HEV IgG varied from 5% to 19% depending on the assay used and was 16% when confirmed by reactivity in two assays (17% for males and 13% for females). There was a significantly higher seroprevalence in donors older than 50 years for the two sexes, 57/170 (34%) versus 16/330 (5%) (P < 0.001; Fisher's exact test).

Patient serum samples.

A total of 216 (26%) of the samples had hepatitis E markers (i.e., anti-HEV IgM, IgG, and/or HEV RNA). Anti-HEV IgM was identified in 66 (31%) of those samples (Tables 3 and 4). Among the 316 patients, the seroprevalence of anti-HEV IgG was more than twice as high in patients older than 50 years (99/187, 53%) compared to those younger than 50 years (32/129, 25%) (P < 0.0001; Fisher's exact test). There was no difference in prevalence between the genders, with seroprevalences of 66/171 (38%) among males and of 65/145 (45%) among females (P = 0.30; Fisher's exact test). Anti-HEV IgM and HEV RNA were equally prevalent in patients younger and older than 50 years (9% and 8% versus 8% and 6%) with no gender difference (see Fig. S3 in the supplemental material).

The 137 patients with suspected hepatitis E had the highest anti-HEV prevalence, and 93 (68%) had more than one marker for hepatitis E indicating ongoing infection (Table 5). Another 32% had confirmed anti-HEV IgG indicating recent HEV infection. The patients with suspected HEV infection had the highest rate of confirmed HEV IgM reactivity (46/66; 68%). Forty-two of 45 patients (93%) were reactive with DiaPro followed by 27/45 (60%) reactive with DSI. Most HEV-RNA-positive serum samples in this group (14/16) had detectable HEV markers with DiaPro and Axiom assays followed by the DSI assay (13 serum samples) (Table 5). Additionally, patients with liver disease (39/156, 25%) and liver transplant recipients (7/23; 30%) had a higher seroprevalence against hepatitis E than blood donors (P = 0.02; Fisher′s exact test) (Table 4).

TABLE 5.

Sensitivity for anti-HEV IgG and/or IgM detection in 221 patients with confirmed ongoing or passed hepatitis E, i.e., positive for two or more HEV markers or HEV RNA

Patient group and assay (no. of patients with HEV markers) HEV IgM positive; % (HEV RNA positive) HEV IgG positive; % (HEV RNA positive) IgM and/or IgG positive; % (HEV RNA positive)
Blood donors (82) 13 (1) 82 (5) 82 (5)
    DiaPro 7; 54 (1) 80; 98 (5) 81; 99 (5)
    Axiom 3; 23 (0) 76; 93 (5) 76; 93 (5)
    DSI 11; 85 (0) 51; 62 (1) 56; 68 (1)
    Mikrogen 1; 8 (0) 33; 40 (0) 33; 40 (0)
    Euroimmun 1; 8 (0) 23; 28 (1) 23; 28 (1)
Confirmed hepatitis E (93a) 45 (12) 91 (15) 92 (15)
    DiaPro 42; 93 (10) 90; 99 (14) 90; 97 (14)
    Axiom 15; 33 (10) 90; 99 (14) 90; 97 (14)
    DSI 27; 60 (11) 77; 85 (12) 77; 83 (13)
    Mikrogen 19; 42 (11) 74; 81 (12) 74; 80 (12)
    Euroimmun 15; 33 (10) 54; 59 (12) 55; 59 (12)
Other liver disease (39a) 8 (0) 38 (2) 38 (2)
    DiaPro 0 35; 92 (2) 35; 90 (2)
    Axiom 1; 12 (0) 33; 87 (2) 33; 84 (2)
    DSI 6; 75 (0) 25; 66 (1) 26; 67 (1)
    Mikrogen 4; 50 (0) 23; 61 (1) 25; 64 (1)
    Euroimmun 0 11; 29 (1) 11; 28 (1)
Liver transplanted (7a) 0 6 (1) 6 (1)
    DiaPro 0 6 (1) 6; 86 (1)
    Axiom 0 6 (1) 6; 86 (1)
    DSI 0 4 (1) 4; 57 (1)
    Mikrogen 0 4 (1) 4; 57 (1)
    Euroimmun 0 4 (1) 4; 57 (1)
Total (221) 66 (13) 217 (22) 218 (23)
    DiaPro 49; 75 (11) 210; 97 (22) 211; 97 (22)
    Axiom 19; 29 (10) 205; 94 (22) 205; 94 (22)
    DSI 44; 67 (11) 153; 71 (15) 163; 75 (16)
    Mikrogen 24; 36 (11) 134; 62 (14) 136; 62 (14)
    Euroimmun 16; 24 (10) 92; 42 (15) 93; 43 (15)
a

One patient has HEV RNA only as a marker for HEV infection.

The sensitivity for detection of past or present HEV infection in all patient groups varies from 43% to 97% (Table 5), and the specificity varies from 96.6% to 99.5% (Table 6) between the assays.

TABLE 6.

Specificity for anti-HEV IgG and IgM detection based on 595 sera from patients without markers for HEV infection or reactive in only one assay and regarded as nonspecific.

Patient group (no.) and assay No. nonreactive for HEV IgM (%) No. nonreactive for HEV IgG (%) No. nonreactive for both markers (%)
Blood donors (418)
    DiaPro 418 (100) 403 (96.4) 403 (96.4)
    Axiom 418 (100) 414 (99.0) 414 (99.0)
    DSI 417 (99.8) 417 (99.8) 416 (99.5)
    Mikrogen 415 (99.3) 418 (100) 412 (98.6)
    Euroimmun 418 (100) 417 (99.8) 417 (99.8)
Suspected hepatitis E (44)
    DiaPro 44 (100) 43 (97.7) 43 (97.7)
    Axiom 43 (97.7) 44 (100) 43 (97.7)
    DSI 43 (97.7) 44 (100) 43 (97.7)
    Mikrogen 41 (93.2) 44 (100) 41 (93.2)
    Euroimmun 44 (100) 43 (97.7) 43 (97.7)
Other liver disease (117)
    DiaPro 117 (100) 113 (96.6) 113 (96.6)
    Axiom 117 (100) 113 (96.6) 113 (96.6)
    DSI 117 (100) 115 (98.3) 115 (98.3)
    Mikrogen 115 (98.3) 116 (99.1) 114 (97.4)
    Euroimmun 117 (100) 116 (99.1) 116 (99.1)
Transplant recipients (16)
    DiaPro 16 (100) 15 (93.8) 15 (93.8)
    Axiom 16 (100) 15 (93.8) 15 (93.8)
    DSI 16 (100) 16 (100) 16 (100)
    Mikrogen 15 (93.8) 16 (100) 15 (93.8)
    Euroimmun 16 (100) 15 (93.8) 15 (93.8)
Total (595)
    DiaPro 595 (100) 574 (96.5) 575 (96.6)
    Axiom 594 (99.8) 586 (98.5) 586 (98.5)
    DSI 593 (99.7) 592 (99.5) 591 (99.3)
    Mikrogen 586 (98.5) 594 (99.8) 583 (98.0)
    Euroimmun 595 (100) 591 (99.3) 592 (99.5)

Follow-up serum samples.

To investigate possible differences due to time between the assays in the detection of anti-HEV IgG or IgM, serial samples were investigated for 27 patients, 15 of whom showed the same reactivity with all assays in serum samples drawn 2 weeks to 2 years apart (see Table S4 in the supplemental material). Anti-HEV IgM was shown to persist in patient 1 for at least 7 months with all assays, in patient 23 for at least 5 months with the Axiom assay, and in patient 13 for 2 months with the DiaPro assay. Patient 115 was consistently reactive for anti-HEV IgM in two serum samples drawn 2 weeks apart with the Mikrogen assay. Anti-HEV IgG was shown to persist with all assays for at least 5 years in patient 51 and for at least 1 year in three other patients.

DISCUSSION

In our comparison of anti-HEV IgM assays, concordant results were obtained with 71% to 81% of the serum samples from patients with suspected hepatitis E. This indicates that most of these assays can diagnose acute HEV infection because generally high titers of anti-HEV IgM are present before the onset of symptoms. The level of anti-HEV IgM decreases with time and becomes undetectable 4 to 6 months after acute infection (16, 30). Anti-HEV IgM may therefore become undetectable earlier after an acute infection when using the less sensitive assays. Sensitivity for anti-HEV IgM varied up to 19-fold between the assays, which may be reflected in the observed persistence of anti-HEV IgM, which varied from a few weeks to 3 months. However, follow-up samples were available for only a few patients. All samples that were single reactive for anti-HEV IgM with the DiaPro assay were also reactive for other hepatitis E markers, suggesting that the more sensitive assays may diagnose a hepatitis E virus infection for a longer period after onset. This is important for the clinician because most patients are sampled rather late after the onset due to lack of awareness among physicians in Nordic countries of endemic hepatitis E. Therefore, a higher sensitivity for anti-HEV IgM may not always result in a higher number of early diagnosed infections. Most of the singly reactive and unconfirmed anti-HEV IgM results were obtained with the Mikrogen and DSI assays, which may indicate nonspecific reactions. It may also indicate that these assays detect preformed anti-HEV IgM due to immature B lymphocytes unrelated to previous exposure to HEV, as has been shown for IgM against hepatitis B virus core antigen (31).

Acute hepatitis E may be diagnosed not only by IgM but also by HEV RNA, which is detectable 1 to 2 weeks before the onset of symptoms and persists for 1 week in serum and for another 2 weeks in feces (16). Due to this short duration of the viremic period, undetectable HEV RNA may not exclude acute hepatitis E. Although HEV RNA was detected in 10 samples that were highly reactive for anti-HEV IgM with all five assays, HEV RNA was also present in 13 samples lacking anti-HEV IgM, which indicates that there may be either a weak response that is not detected by the most sensitive assays or perhaps that there is a lack of IgM response in some patients. Our results indicate that patients with elevated transaminases or suspected ongoing HEV infection should be tested for anti-HEV and HEV RNA. Previously, nonreactivity for anti-HEV has been reported in Swedish blood donors with 1 per 7,980 donations having detectable HEV RNA, most without other HEV markers (32).

Anti-HEV IgG appears shortly after IgM, increases from the acute through the convalescent phase, and may be detected up to 4.5 years after acute infection (18, 33). When comparing the endpoints of a dilution series, the sensitivity of anti-HEV IgG detection with the compared assays differed by up to 17 times. This was reflected when testing samples for anti-HEV IgG with 70% to 99% concordant results, which is important not only for the determination of previous exposure to HEV or seroprevalence of anti-HEV in different populations but also for the detection of replicating HEV infection as shown by the presence of HEV RNA. It is notable that 7 of the 12 samples with HEV RNA and anti-HEV IgG were reactive only with the Axiom and DiaPro assays. The high prevalence of HEV RNA in samples with only detectable anti-HEV IgG may indicate a low sensitivity for the detection of anti-HEV IgM during acute infection.

The assays may include viral antigens common for only one or two genotypes and, due to considerable cross-reactivity between the genotypes, are able to detect antibodies directed against other genotypes. The compared assays had similar recombinant antigens, although Axiom differed by having labeled recombinant HEV antigens instead of labeled anti-human antibodies as used in the other assays. Additionally, the DiaPro assay was based on peptides corresponding to open reading frame 2 (ORF2) and three of the genotypes 1 to 4. This may, to some extent, explain the higher sensitivity with these assays.

The divergent positive results with the less sensitive assays indicate nonspecific reactivity because 5% of the serum samples were reactive for anti-HEV IgG in just one assay, and none of these singly reactive samples had detectable HEV RNA. Singly reactive serum samples with either of the two most sensitive assays may have had nonspecific results. However, this was not the case because the majority of singly reactive results with these assays could be confirmed by another HEV marker. There were concordant results with DiaPro and Axiom for IgG in 99% of the samples from patients with suspected hepatitis E, so any of these assays may be used to confirm the result obtained by the other. Despite the high sensitivity for anti-HEV detection, there were serum samples from immunocompetent patients with HEV RNA lacking serological markers for HEV. The significance of this finding needs further investigation.

Supplementary Material

Supplemental material

ACKNOWLEDGMENTS

The project PREDEMICS (7th Framework Program) provided funding under grant agreement 278433; Sahlgrenska University Hospital provided funding under grant (51590-6326), The Health and Medical Care Committee of the Regional Executive Board, Region Västra Götaland provided funding under grant VGFOUREG-474431, and FoU-rådet Södra Älvsborg provided funding under grant VGFOUSA-418021.

We declare no conflicts of interest.

Footnotes

Supplemental material for this article may be found at http://dx.doi.org/10.1128/JCM.02343-15.

REFERENCES

  • 1.Smith DB, Simmonds P, Jameel S, Emerson SU, Harrison TJ, Meng XJ, Okamoto H, Van der Poel WH, Purdy MA. 2015. Consensus proposals for classification of the family Hepeviridae. J Gen Virol 96:1191–1192. doi: 10.1099/vir.0.000115. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 2.Laperche S, Izopet J, Lefrere JJ. 2014. Safety measures to prevent hepatitis E virus transmission by blood transfusion. Transfusion 54:2134–2135. doi: 10.1111/trf.12735. [DOI] [PubMed] [Google Scholar]
  • 3.Wedemeyer H, Pischke S, Manns MP. 2012. Pathogenesis and treatment of hepatitis E virus infection. Gastroenterology 142:1388–1397.e1381. doi: 10.1053/j.gastro.2012.02.014. [DOI] [PubMed] [Google Scholar]
  • 4.Rein DB, Stevens GA, Theaker J, Wittenborn JS, Wiersma ST. 2012. The global burden of hepatitis E virus genotypes 1 and 2 in 2005. Hepatology 55:988–997. doi: 10.1002/hep.25505. [DOI] [PubMed] [Google Scholar]
  • 5.Said B, Ijaz S, Kafatos G, Booth L, Thomas HL, Walsh A, Ramsay M, Morgan D. 2009. Hepatitis E outbreak on cruise ship. Emerg Infect Dis 15:1738–1744. doi: 10.3201/eid1511.091094. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 6.Gerolami R, Moal V, Colson P. 2008. Chronic hepatitis E with cirrhosis in a kidney-transplant recipient. N Engl J Med 358:859–860. doi: 10.1056/NEJMc0708687. [DOI] [PubMed] [Google Scholar]
  • 7.Haagsma EB, van den Berg AP, Porte RJ, Benne CA, Vennema H, Reimerink JH, Koopmans MP. 2008. Chronic hepatitis E virus infection in liver transplant recipients. Liver Transpl 14:547–553. doi: 10.1002/lt.21480. [DOI] [PubMed] [Google Scholar]
  • 8.Kamar N, Selves J, Mansuy JM, Ouezzani L, Peron JM, Guitard J, Cointault O, Esposito L, Abravanel F, Danjoux M, Durand D, Vinel JP, Izopet J, Rostaing L. 2008. Hepatitis E virus and chronic hepatitis in organ-transplant recipients. N Engl J Med 358:811–817. doi: 10.1056/NEJMoa0706992. [DOI] [PubMed] [Google Scholar]
  • 9.Halac U, Beland K, Lapierre P, Patey N, Ward P, Brassard J, Houde A, Alvarez F. 2012. Cirrhosis due to chronic hepatitis E infection in a child post-bone marrow transplant. J Pediatr 160:871–874. doi: 10.1016/j.jpeds.2012.01.028. [DOI] [PubMed] [Google Scholar]
  • 10.Ollier L, Tieulie N, Sanderson F, Heudier P, Giordanengo V, Fuzibet JG, Nicand E. 2009. Chronic hepatitis after hepatitis E virus infection in a patient with non-Hodgkin lymphoma taking rituximab. Ann Intern Med 150:430–431. doi: 10.7326/0003-4819-150-6-200903170-00025. [DOI] [PubMed] [Google Scholar]
  • 11.Tavitian S, Peron JM, Huynh A, Mansuy JM, Ysebaert L, Huguet F, Vinel JP, Attal M, Izopet J, Recher C. 2010. Hepatitis E virus excretion can be prolonged in patients with hematological malignancies. J Clin Virol 49:141–144. doi: 10.1016/j.jcv.2010.06.016. [DOI] [PubMed] [Google Scholar]
  • 12.van den Berg B, van der Eijk AA, Pas SD, Hunter JG, Madden RG, Tio-Gillen AP, Dalton HR, Jacobs BC. 2014. Guillain-Barre syndrome associated with preceding hepatitis E virus infection. Neurology 82:491–497. doi: 10.1212/WNL.0000000000000111. [DOI] [PubMed] [Google Scholar]
  • 13.van Eijk JJ, Madden RG, van der Eijk AA, Hunter JG, Reimerink JH, Bendall RP, Pas SD, Ellis V, van Alfen N, Beynon L, Southwell L, McLean B, Jacobs BC, van Engelen BG, Dalton HR. 2014. Neuralgic amyotrophy and hepatitis E virus infection. Neurology 82:498–503. doi: 10.1212/WNL.0000000000000112. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 14.Kamar N, Bendall RP, Peron JM, Cintas P, Prudhomme L, Mansuy JM, Rostaing L, Keane F, Ijaz S, Izopet J, Dalton HR. 2011. Hepatitis E virus and neurologic disorders. Emerg Infect Dis 17:173–179. doi: 10.3201/eid1702.100856. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 15.Naha K, Karanth S, Prabhu M, Sidhu MS. 2012. Dual infection with hepatitis A and E virus presenting with aseptic meningitis: a case report. Asian Pac J Trop Med 5:587–588. doi: 10.1016/S1995-7645(12)60104-7. [DOI] [PubMed] [Google Scholar]
  • 16.Huang S, Zhang X, Jiang H, Yan Q, Ai X, Wang Y, Cai J, Jiang L, Wu T, Wang Z, Guan L, Shih JW, Ng MH, Zhu F, Zhang J, Xia N. 2010. Profile of acute infectious markers in sporadic hepatitis E. PLoS One 5(10):e13560. doi: 10.1371/journal.pone.0013560. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 17.Drobeniuc J, Meng J, Reuter G, Greene-Montfort T, Khudyakova N, Dimitrova Z, Kamili S, Teo CG. 2010. Serologic assays specific to immunoglobulin M antibodies against hepatitis E virus: pangenotypic evaluation of performances. Clin Infect Dis 51:e24–e27. doi: 10.1086/654801. [DOI] [PubMed] [Google Scholar]
  • 18.Abravanel F, Chapuy-Regaud S, Lhomme S, Miedouge M, Peron JM, Alric L, Rostaing L, Kamar N, Izopet J. 2013. Performance of anti-HEV assays for diagnosing acute hepatitis E in immunocompromised patients. J Clin Virol 58:624–628. doi: 10.1016/j.jcv.2013.10.003. [DOI] [PubMed] [Google Scholar]
  • 19.Rossi-Tamisier M, Moal V, Gerolami R, Colson P. 2013. Discrepancy between anti-hepatitis E virus immunoglobulin G prevalence assessed by two assays in kidney and liver transplant recipients. J Clin Virol 56:62–64. doi: 10.1016/j.jcv.2012.09.010. [DOI] [PubMed] [Google Scholar]
  • 20.Pas SD, Streefkerk RH, Pronk M, de Man RA, Beersma MF, Osterhaus AD, van der Eijk AA. 2013. Diagnostic performance of selected commercial HEV IgM and IgG ELISAs for immunocompromised and immunocompetent patients. J Clin Virol 58:629–634. doi: 10.1016/j.jcv.2013.10.010. [DOI] [PubMed] [Google Scholar]
  • 21.Avellon A, Morago L, Garcia-Galera MD, Munoz M, Echevarria JM. 2015. Comparative sensitivity of commercial tests for hepatitis E genotype 3 virus antibody detection. J Med Virol 87:1934–1939. doi: 10.1002/jmv.24251. [DOI] [PubMed] [Google Scholar]
  • 22.Schnegg A, Burgisser P, Andre C, Kenfak-Foguena A, Canellini G, Moradpour D, Abravanel F, Izopet J, Cavassini M, Darling KE. 2013. An analysis of the benefit of using HEV genotype 3 antigens in detecting anti-HEV IgG in a European population. PLoS One 8(5):e62980. doi: 10.1371/journal.pone.0062980. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 23.Zhang H, Mohn U, Prickett JR, Schalk S, Motz M, Halbur PG, Feagins AR, Meng XJ, Opriessnig T. 2011. Differences in capabilities of different enzyme immunoassays to detect anti-hepatitis E virus immunoglobulin G in pigs infected experimentally with hepatitis E virus genotype 3 or 4 and in pigs with unknown exposure. J Virol Methods 175:156–162. doi: 10.1016/j.jviromet.2011.05.001. [DOI] [PubMed] [Google Scholar]
  • 24.Herremans M, Bakker J, Duizer E, Vennema H, Koopmans MP. 2007. Use of serological assays for diagnosis of hepatitis E virus genotype 1 and 3 infections in a setting of low endemicity. Clin Vaccine Immunol 14:562–568. doi: 10.1128/CVI.00231-06. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 25.Mansuy JM, Bendall R, Legrand-Abravanel F, Saune K, Miedouge M, Ellis V, Rech H, Destruel F, Kamar N, Dalton HR, Izopet J. 2011. Hepatitis E virus antibodies in blood donors, France. Emerg Infect Dis 17:2309–2312. doi: 10.3201/eid1712.110371. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 26.Kaba M, Moal V, Gerolami R, Colson P. 2013. Epidemiology of mammalian hepatitis E virus infection. Intervirology 56:67–83. doi: 10.1159/000342301. [DOI] [PubMed] [Google Scholar]
  • 27.Baylis SA, Blumel J, Mizusawa S, Matsubayashi K, Sakata H, Okada Y, Nubling CM, Hanschmann KM. 2013. World Health Organization international standard to harmonize assays for detection of hepatitis E virus RNA. Emerg Infect Dis 19:729–735. doi: 10.3201/eid1905.121845. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 28.Hellmer M, Paxeus N, Magnius L, Enache L, Arnholm B, Johansson A, Bergstrom T, Norder H. 2014. Detection of pathogenic viruses in sewage provided early warnings of hepatitis A virus and norovirus outbreaks. Appl Environ Microbiol 80:6771–6781. doi: 10.1128/AEM.01981-14. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 29.Baratloo A, Hosseini M, Negida A, El Ashal G. 2015. Part 1: simple definition and calculation of accuracy, sensitivity and specificity. Emerg (Tehran) 3:48–49. [PMC free article] [PubMed] [Google Scholar]
  • 30.Emerson SU, Purcell RH. 2007. Hepatitis E. Pediatr Infect Dis J 26:1147–1148. doi: 10.1097/INF.0b013e31815dd7c2. [DOI] [PubMed] [Google Scholar]
  • 31.Sallberg M, Magnius LO. 1989. Enzyme immunoassay for anti-hepatitis B core (HBc) immunoglobulin G1 and significance of low-level results in competitive assays for anti-HBc. J Clin Microbiol 27:849–853. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 32.Baylis SA, Gartner T, Nick S, Ovemyr J, Blumel J. 2012. Occurrence of hepatitis E virus RNA in plasma donations from Sweden, Germany and the United States. Vox Sang 103:89–90. doi: 10.1111/j.1423-0410.2011.01583.x. [DOI] [PubMed] [Google Scholar]
  • 33.Perez-Gracia MT, Suay B, Mateos-Lindemann ML. 2014. Hepatitis E: an emerging disease. Infect Genet Evol 22:40–59. doi: 10.1016/j.meegid.2014.01.002. [DOI] [PubMed] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Supplementary Materials

Supplemental material

Articles from Journal of Clinical Microbiology are provided here courtesy of American Society for Microbiology (ASM)

RESOURCES