Skip to main content
Journal of Clinical Pathology logoLink to Journal of Clinical Pathology
. 1970 Sep;23(6):540–544. doi: 10.1136/jcp.23.6.540

A new rapid method for automatic complement-fixation tests

R Vargues 1, C Studievic 1, Ph Maupas 1
PMCID: PMC476827  PMID: 5529255

Abstract

Several automatic methods have been described for complement-fixation tests. However, each of these methods presents some inconvenience either due to cross contamination or to limited sensitivity. The new method consists basically in separating clearly the fixation stage from the haemolytic stage by using two different sampler plates placed on the same sampler. By this procedure, it becomes possible to obtain a very high sensitivity. The serologist may set the temperature and the duration of the reaction according to the properties of the tests under study. In addition, the sampling rate can be raised to 120 analyses per hour.

Full text

PDF
540

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Irvine W. J. Automated determinations of thyroid and gastric complement-fixing antibody; comparison with the fluorescent antibody and manual complement-fixation methods. Clin Exp Immunol. 1966 Jul;1(3):341–354. [PMC free article] [PubMed] [Google Scholar]
  2. Pugh V. W., Gaze R. W. Automated screening method for the Wassermann reaction. Br J Vener Dis. 1965 Sep;41(3):221–227. doi: 10.1136/sti.41.3.221. [DOI] [PMC free article] [PubMed] [Google Scholar]
  3. Pugh V. W., Gaze R. W. The Reiter protein complement-fixation test using the Auto-Analyzer. J Clin Pathol. 1966 Nov;19(6):595–599. doi: 10.1136/jcp.19.6.595. [DOI] [PMC free article] [PubMed] [Google Scholar]
  4. Roumiantzeff M. Amélioration de la méthode automatique Technicon de fixation du complément dite de dilution exponentielle. Ann Biol Clin (Paris) 1969 Jan-Feb;27(1):11–20. [PubMed] [Google Scholar]
  5. Taylor C. E., Kershaw J. W., Heimer G. V. An evaluation of the Technicon Autoanalyzer for automating complement-fixation tests. J Clin Pathol. 1968 Jul;21(4):521–526. doi: 10.1136/jcp.21.4.521. [DOI] [PMC free article] [PubMed] [Google Scholar]
  6. Vargues R. Eléments de cinétique immunologique. Biol Med (Paris) 1966 Nov-Dec;55(6):529–555. [PubMed] [Google Scholar]
  7. Vargues R. Principles and technique of a simple method to automate the complement fixation reactions. Bibl Haematol. 1968;29:958–967. doi: 10.1159/000384730. [DOI] [PubMed] [Google Scholar]
  8. Vargues R., Studievic C., Ripault C. L'automatisation de la réaction de Bordet-Wassermann. Ann Biol Clin (Paris) 1965 May-Jun;23(5):623–640. [PubMed] [Google Scholar]
  9. Vargues R. The use of the autoanalyzer for the automatic titration of antigenic preparations by means of complement-fixation. Ann N Y Acad Sci. 1965 Nov 9;130(2):819–826. doi: 10.1111/j.1749-6632.1965.tb12625.x. [DOI] [PubMed] [Google Scholar]

Articles from Journal of Clinical Pathology are provided here courtesy of BMJ Publishing Group