Skip to main content
Journal of Clinical Pathology logoLink to Journal of Clinical Pathology
. 1972 Feb;25(2):155–158. doi: 10.1136/jcp.25.2.155

Clinical application and mechanization of a simple and inexpensive method for estimating T3 uptake in serum

W W Walther 1
PMCID: PMC477246  PMID: 5017444

Abstract

This very inexpensive method of estimating T3 uptake, already described (Walther, 1971), uses only 0·1 ml of patient's serum and discriminates between thyrotoxicosis and myxoedema much better than the resin sponge method. It can readily be mechanized and the `free thyroxine index' derived has normal limits of 3·0 to 8·0.

Full text

PDF
155

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Clark F., Horn D. B. Relationship between serum protein-bound iodine and resin uptake of 131-I-triiodothyronine. J Clin Endocrinol Metab. 1966 Mar;26(3):352–353. doi: 10.1210/jcem-26-3-352. [DOI] [PubMed] [Google Scholar]
  2. Walther W. W. Simple, inexpensive micro method for the estimation of T3 uptake. J Clin Pathol. 1971 Mar;24(2):177–179. doi: 10.1136/jcp.24.2.177. [DOI] [PMC free article] [PubMed] [Google Scholar]

Articles from Journal of Clinical Pathology are provided here courtesy of BMJ Publishing Group