Abstract
The blood of 104 medical inpatients was examined at various intervals during storage for 72 hours using a Coulter S counter. Over this period remarkable stability of the white cell count, red cell count, haemoglobin, and mean cell haemoglobin was demonstrated. This permits a useful interpretation of indices obtained in routine postal samples sent to the laboratory by general practitioners for screening. Furthermore, the implications of high correlations between red cell indices in freshly examined blood are considered and the regression line MCV = 2·5 MCH + 16 is derived. Using this relationship the normal range of the Coulter S MCHC is defined as 32·6-33·7 g/dl. The significance of the Coulter MCHC in present-day practice is reassessed and the importance of recognizing values for MCV and MCH not coinciding with the regression line is briefly discussed.
Full text
PDF





Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Barnard D. F., Carter A. B., Crosland-Taylor P. J., Stewart J. W. An evaluation of the Coulter model S. J Clin Pathol Suppl Coll Pathol. 1969;3:26–33. doi: 10.1136/jcp.s2-3.1.26. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Black P. J. Epitaph for the M.C.H.C. Br Med J. 1971 Nov 20;4(5785):492–493. doi: 10.1136/bmj.4.5785.492-c. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Brittin G. M., Brecher G. Instrumentation and automation in clinical hematology. Prog Hematol. 1971;7:399–341. [PubMed] [Google Scholar]
- England J. M., Walford D. M., Waters D. A. Re-assessment of the reliability of the haematocrit. Br J Haematol. 1972 Aug;23(2):247–256. doi: 10.1111/j.1365-2141.1972.tb03477.x. [DOI] [PubMed] [Google Scholar]
- MATTERN C. F., BRACKETT F. S., OLSON B. J. Determination of number and size of particles by electrical gating: blood cells. J Appl Physiol. 1957 Jan;10(1):56–70. doi: 10.1152/jappl.1957.10.1.56. [DOI] [PubMed] [Google Scholar]
- Okuno T. Red cell size as measured by the Coulter model S. J Clin Pathol. 1972 Jul;25(7):599–602. doi: 10.1136/jcp.25.7.599. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Pinkerton P. H., Spence I., Ogilvie J. C., Ronald W. A., Marchant P., Ray P. K. An assessment of the Coulter counter model S. J Clin Pathol. 1970 Feb;23(1):68–76. doi: 10.1136/jcp.23.1.68. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Rose M. S. Epitaph for the M.C.H.C. Br Med J. 1971 Oct 16;4(5780):169–169. doi: 10.1136/bmj.4.5780.169. [DOI] [PMC free article] [PubMed] [Google Scholar]