Abstract
Accurate enumeration of cells in the cerebrospinal fluid is not feasible with the current method of counting cells in the Fuchs Rosenthal or Neubauer chamber when the count is near normal since the volume of fluid examined is too small. A sample of adequate volume to permit such accurate assessment may be collected from the lumbar puncture needle into a syringe through a ruled membrane filter in a Swinney cartridge. A study of 291 samples shows that the upper limit of the normal cerebrospinal fluid count is 2000 cells/ml (2/cmm) and not 5000/ml (5/cmm) as is currently accepted.
Full text
PDF




Images in this article
Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Jéquier M., Dufresne J. J. Diagnosis of cryptococal meningitis. N Engl J Med. 1972 Apr 6;286(14):785–786. doi: 10.1056/NEJM197204062861425. [DOI] [PubMed] [Google Scholar]
- KLINE T. S. Cytological examination of the cerebrospinal fluid. Cancer. 1962 May-Jun;15:591–597. doi: 10.1002/1097-0142(196205/06)15:3<591::aid-cncr2820150320>3.0.co;2-8. [DOI] [PubMed] [Google Scholar]
- Wertlake P. T., Markovits B. A., Stellar S. Cytologic evaluation of cerebrospinal fluid with clinical and histologic correlation. Acta Cytol. 1972 May-Jun;16(3):224–239. [PubMed] [Google Scholar]