Automated technique for the estimation of fetal haemoglobin

S R Brook 1,2, R S Crane 1,2, R G Huntsman 1,2, T D De C Marshall 1,2, D S McLellan 1,2, M J Semple 1,2
PMCID: PMC478159  PMID: 4412142

Abstract

An automated alkali denaturation technique which measures fetal haemoglobin is described. This method offers greater speed and a lower standard deviation than comparable manual methods.