Inverse-power-law behavior of cellular motility reveals stromal–epithelial cell interactions in 3D co-culture by OCT fluctuation spectroscopy

Amy L Oldenburg 1,2,3,*, Xiao Yu 1,2, Thomas Gilliss 1, Oluwafemi Alabi 4, Russell M Taylor II 4,1, Melissa A Troester 3,5
PMCID: PMC4783137  NIHMSID: NIHMS733443  PMID: 26973862

Abstract

The progression of breast cancer is known to be affected by stromal cells within the local microenvironment. Here we study the effect of stromal fibroblasts on the in-place motions (motility) of mammary epithelial cells within organoids in 3D co-culture, inferred from the speckle fluctuation spectrum using optical coherence tomography (OCT). In contrast to Brownian motion, mammary cell motions exhibit an inverse power-law fluctuation spectrum. We introduce two complementary metrics for quantifying fluctuation spectra: the power-law exponent and a novel definition of the motility amplitude, both of which are signal- and position-independent. We find that the power-law exponent and motility amplitude are positively (p<0.001) and negatively (p<0.01) correlated with the density of stromal cells in 3D co-culture, respectively. We also show how the hyperspectral data can be visualized using these metrics to observe heterogeneity within organoids. This constitutes a simple and powerful tool for detecting and imaging cellular functional changes with OCT.

1. INTRODUCTION

A richness of functional information can be garnered from the time-dependent properties of tissues revealed by speckle fluctuations in coherence imaging techniques, including intracellular motility [1,2], hemodynamics [3], apoptosis [4], and ciliary activity [5]. While speckle fluctuation models have been well-developed for particle flow and diffusion in OCT [6,7], we are only beginning to understand the fluctuation spectra arising from intracellular motions in living tissues. Tissue fluctuation measurements are a growing area of research for assessing drug-response in cancer models in vitro [8,9], oocyte viability [10], and cortical cell recovery after stroke in vivo [3].

Optical coherence tomography (OCT) is particularly well-suited for imaging optically thick 3D tissue culture models, which provide a microenvironment that recapitulates many in vivo features [11]. We have previously shown how OCT of 3D mammary epithelial cell (MEC) organoids provides the ability to non-invasively and longitudinally monitor the evolution of organoids over weeks [12]. We have also shown how coupling temporal fluctuation analysis with polarization-sensitive OCT in these models allows for preferential image contrast of MEC organoids against a background of diffusive gold nanorod probes [13]. In that study, we reported on the observation of a motility signal from MEC organoids with a decay constant of several seconds. We note that, in contrast to cellular migration studies, this apparent “motility” represents the rapid, in-place motions of intracellular components measured over a relatively short time scale (<5 min). In this paper, we report on a comprehensive study of this motility signal from MEC organoids without the use of any contrast agents. As part of this study we developed methods to scale up to large numbers of organoids to achieve sufficient statistics, including methods for unbiased segmentation of MEC organoids, stable parameters for describing the fluctuation spectra, and an intuitive visualization method for observing cellular-level heterogeneity within the organoids.

Here we apply these techniques to a stromal-epithelial cell signaling model relevant to breast cancer. Increasing evidence suggests that fibroblasts in the mammary stroma influence the development and progression of cancer in MEC [11, 14]. MEC with a basal-like subtype (as defined by gene expression), such as those in this study, may have unique susceptibility to fibroblast signals that are both soluble and mechanical in nature [15]. It is noted that the basal-like subtype is a type of breast cancer associated with a particularly poor prognosis [16]. We have recently shown that the morphology of basal-like MEC organoids changes with progression (normal versus pre-malignant) and depends upon the presence of fibroblasts in 3D co-culture [12]. Here we study the fluctuation spectra of MEC in the same co-culture model to understand how the apparent motility is affected by stromal cell signaling.

As will be shown, our fluctuation spectra suggest that intracellular motility in this model is well-described by an inverse power-law, and is distinct from the Lorentzian distributions expected for diffusion. Interestingly, the inverse power-law (also known as 1/f noise) is scale-invariant and arises in systems with long-range correlations or memory [17]. The power-law exponent is well-behaved in these 3D cultures and provides new insight into the effect of fibroblasts on MEC motility.

2. METHODS

A. 3D co-culture preparation

We used a 3D cell co-culture method previously described by Johnson et al [18], with specific culture methods described in our previous publication [12]. Briefly, MEC form a multicellular, polarized structure (an “organoid”) in 3D culture that exhibits many features similar to acini in the in vivo human mammary gland [19]. In this study we employed two MEC lines: MCF10A (“normal”), and MCF10DCIS.com (“pre-malignant”), the latter of which form organoids that are similar to ductal carcinoma in situ (DCIS). MEC were co-cultured with stromal cells consisting of hTERT-immortalized fibroblasts from reduction mammoplasty (RMF). All cells were maintained in 2D or 3D culture at 37°C and 5% CO2 with culture medium consisting of DMEM/F-12 and added ingredients listed in [20]. 2D cultures were used to grow a sufficient cell population to seed 3D cultures. For 3D cultures, a 1:1 mixture of collagen I (2mg/mL):Matrigel (BD Biosciences) extracellular scaffold was prepared. 10 mm diameter microwells were pre-coated with 85 μL of scaffold before the addition of 180 μL cell-scaffold mixtures on top. After gelation, 250 μL of cell medium was added and changed every 2 days.

A variety of 3D co-culture conditions were prepared. Cultures with either normal MEC (nc=10, no=46) or premalignant MEC (nc=10, no=39) were prepared, where nc represents the number of independent cultures, and no represents the total number of organoids imaged with that condition. While the seed density of MEC were kept constant at 30,000/cm3, the seed density of RMF were prepared to be 0 (nc=6, no=25), 30,000/cm3 (nc=6, no=22), 90,000/cm3 (nc=4, no=21), and 300,000/cm3 (nc=4, no=17). Culture times from 8–9 days (nc=8, no=23) and 14–18 days (nc=12, no=62) were explored. After 19 days, some cultures were formalin fixed (nc=4, no=27).

B. OCT system and data acquisition

We employed a spectral domain, polarization-sensitive OCT system, described in detail previously [21]. Briefly, the OCT system light source was a broadband Ti:Sapphire laser centered at 800 nm (Griffin, KMLabs, Inc.) providing a coherence length of 2.6 μm in air. A 30 mm focal length lens in the sample arm provided a transverse resolution of ~10 μm in aqueous media. For all studies, 6.0–7.5 mW of linearly polarized light (H) was incident upon the sample, and the co-polarized backscattered light (H) was combined with the reference beam and directed to a custom spectrometer. A 4096 pixel line scan camera (Dalsa Piranha) was used to capture spectral interferograms at an A-line rate of 2 kHz into the first 2048 pixels. Sets of 300 successive B-mode images were collected over 1.5 × 1.5 mm into 1000 × 1024 pixels in x × z, respectively, at a frame rate of 0.876 ± 0.004 Hz. We expect this frame rate to be sufficient to capture fluctuation dynamics of MEC organoids, which we have previously found to exhibit an autocorrelation decay time of 4.8 ± 2 s using the same OCT system [13]. Reference subtraction and a digital dispersion compensation method described previously [22] were employed to compute OCT images, where image pixel intensities I(x, z) were computed from the absolute value of the complex analytic signal obtained from the spectral-domain OCT data. Figure 1 displays examples from an OCT image stack collected of a 3D co-culture.

Fig. 1.

Fig. 1

(a) Example stack-averaged OCT image of four MEC organoids (normal) in 3D co-culture with RMF (seed density 30,000/cm3) at 8 days culture time. See Visualization 1 and Visualization 2 corresponding to panels (b) and (c), respectively, which display 50 frames of the image stack at 23× real-time. (The pixel intensity in panel (c) was increased 3.4× for display).

C. Image segmentation

Both manual and semi-automated segmentation methods were used to determine regions of interest (ROIs) for OCT fluctuation spectroscopic analysis. All image stacks were first divided into 3 groups of N=100 images (1–100, 101–200, 201–300 within the original stack) for independent analysis, in order to perform cross-validation. Manual segmentation was then used for the studies reported in Section 3.A below to establish the spectral processing metrics. For all subsequent studies, a semi-automated method was employed to provide unbiased identification of MEC organoids within each OCT image stack.

An overview of the semi-automated segmentation method is displayed in Figure 2. First, the stack-averaged OCT image was computed (Fig. 2a), and a pre-corrected image was generated using predetermined, row-dependent pixel offset and pixel signal amplitude curves. This pre-corrected image was displayed via a custom MATLAB GUI enabling manual selection of a region of ECM that excluded MEC organoids (Fig. 2b, red outline). By assuming a priori that the ECM comprises a region of spatially invariant contrast, the OCT image was then further corrected in depth to auto-balance the image contrast (Fig. 2c). Finally, a pixel intensity threshold of 2× the ECM level and a series of Gaussian blur and erosion operations were performed to identify potential ROIs; only ROIs greater than 800 pixels (corresponding to ~30 cells in cross-section) were kept and identified as MEC organoids (Fig. 2d, yellow regions). Importantly, other than the user identification of the ECM ROI, the method is fully automated. Only one ROI out of 86 was manually rejected due to an image artifact; otherwise all auto-segmented ROIs were included in the subsequent analyses.

Fig. 2.

Fig. 2

Example of the semi-automated segmentation method (see text for description) applied to a stack-averaged OCT image of MEC organoids (pre-malignant) in 3D co-culture with RMF (seed density 90,000/cm3) at 14 days culture time. Notably, these MEC organoids are significantly less spherical than those shown in Fig. 1 due to the different cell line (pre-malignant vs. normal), increased RMF seed density, and increased culture time, consistent with our previous findings on MEC organoid morphology [12]. The challenging MEC organoid shapes are reliably segmented into 10 ROIs in this example using the semiautomated method.

Control 3D cultures, seeded with RMF only, were also imaged. The RMF were not easily detectible in the OCT images. Therefore, we assume that segmentation of MEC:RMF co-cultures predominantly selects MEC organoids.

D. Speckle fluctuation spectroscopic analysis

The speckle fluctuation power spectral density at each image pixel I(x, z) was computed from the discrete Fourier transform, F, over time, t, according to S(x, z, f) = |F(I(x, z, t))|2. This hyperspectral data was then spatially averaged over each ROI, and the f ≤ 0 terms were omitted before model fitting. Nonlinear least-squares fitting was employed with weights given by 1/S(f) (assuming that the variance is equal to the power spectral density). Two models were fitted: a Lorentzian model, which is known to represent Brownian (diffusive) motions in OCT data [23], and an inverse power-law model, which has been used to describe self-organized critical systems [24]. The Lorentzian can be written as:

S(f)=c0γf2+γ2+n, (1)

where the free-fit parameters were taken to be the damping term, γ, a constant of proportionality, c0, and additive white noise, n, all of which were constrained to be >0 during the fitting procedure. The inverse power-law model can be written as:

S(f)=c0f-α+n, (2)

where the free-fit parameters were taken to be the exponent, α, a constant of proportionality, c0, and additive white noise, n, all of which were similarly constrained to be >0 during the fitting procedure.

E. Speckle fluctuation amplitude (“motility amplitude”) analysis

In addition to the quantification of the spectral shapes via γ or α in the models above, a measure of the overall fluctuation amplitude provides a complementary metric for cellular function. While the proportionality constant c0 in Eq. (1) and (2) might appear useful in this regard, it was found to vary strongly with the overall pixel intensity and thus is not representative of cellular function. In our previous work, we introduced the motility amplitude, M, as a normalized standard deviation as follows [13]:

M(x,z)=1Ni=1N(I(x,z,ti)-I¯(x,z))2I¯(x,z), (3)

where N is the number of images, ti are the discrete times at which each image in the stack is collected, and the overbar indicates a time average. Unfortunately, as illustrated in Fig. 3b, this metric does not provide a consistent value for organoids within the same culture condition. Despite normalization for the presumed effect of shot noise in the denominator of Eq. (3), M exhibits a strong decay with the depth of the organoid within the OCT image.

Fig. 3.

Fig. 3

Motility images of the same data as in Fig. 2. (a) Time-averaged OCT image. (b) Motility image obtained using the standard deviation method, Eq. (3), which exhibits depth-dependent roll-off. (c) Motility image obtained using the modified standard deviation method, Eq. (4), that omits random noise. Unlike the other methods, this method appears stable with depth with a value of M = 0.24 ± 0.05 (mean ± s.d.) for the 10 ROIs shown in Fig. 2d. (d) Motility image obtained using the standard deviation with stronger normalization (Eq. (3) numerator and Eq. (4) denominator), which exhibits a depth-dependent increase in M. Also note that an image artifact apparent in panels b and d (red arrow) is absent from panel c; this artifact likely arises from a strong specular reflection at the air-liquid interface.

To address this shortcoming, here we propose a new method for estimating the motility amplitude based upon a modified standard deviation as follows:

M(x,z)=ΓI(x,z,Δt)-I¯(x,z)2I¯(x,z), (4)

where ΓI is the temporal autocorrelation of I(x, z, t), and Δt is the image sampling time. Thus, we write ΓI(Δt)=1N-1i=1N-1I(ti)I(ti+1). The autocorrelation at Δt quantifies the OCT signal that persists for one sampling time, which has the important effect of omitting random noise (such as shot noise) that decorrelates instantaneously. Thus, M represents the fluctuation amplitude of signals that decorrelate at times >Δt but shorter than the total measurement time. Because cell-driven fluctuations have been shown on average to decorrelate with a decay time of ~4.8 s [13] equivalent to ~6Δt, M effectively captures the cellular fluctuation signal.

For M to be unitless and independent of pixel intensity, normalization by the average pixel intensity is used in Eq. (4). Thus, M represents a fractional fluctuation amplitude. As shown in Fig. 3c, this new metric is extremely consistent across a wide dynamic range of organoid average pixel intensities within the same culture, and thus organoids physically lower in the image (which exhibit SNR roll off) provide an M consistent with those nearer the top of the OCT image. Quantitatively, this can be stated by noting that M was independent of both average pixel intensity and depth in the image (R2 < 0.03 for both for the ten ROIs of Fig. 3), while intensity and depth were yet strongly inversely correlated (R2 > 0.9).

For completeness, we also considered renormalizing Eq. (3), the standard deviation, similarly to Eq. (4) so that it is a unitless number. Specifically, the numerator of Eq. (3) was divided by the denominator of Eq. (4). The result of this test is displayed in Fig. 3d, which clearly demonstrates that it is inadequate to provide the depth-independent results needed to represent organoid motility (and, in fact, overcompensates the data, making the lower organoids now display a higher motility value). Thus, we conclude that the modified standard deviation proposed in Eq. (4) and shown in Fig. 3c represents a significant new metric for quantifying the amplitude of cell-driven speckle fluctuations. Importantly, regions of high motility amplitude are well correlated with the ROIs determined semi-automated segmentation, as displayed in Fig. S1. This definition of M is subsequently used in all of the studies described below, where M(x, z) is spatially averaged over each ROI.

3. RESULTS AND DISCUSSION

A. Evidence for the appropriateness of the power-law exponent (α) and the motility amplitude (M) as metrics for quantifying cellular function

1. α uniquely describes live cells

The existence of a reduced set of parameters that accurately represent OCT fluctuation spectra would constitute a powerful tool for 3D cell culture analysis. We first sought to determine whether the power spectra from MEC organoids were consistent with either the Lorentzian power spectrum (Eq. (1)) or the inverse power-law model (Eq. (2)). To compare the power spectra of living and non-living samples, we evaluated ROIs to include either ECM or MEC organoids; 3 of each were manually segmented from each image stack. ROIs were of approximately equal area, but were chosen to be of varying depth within the image to vary the OCT signal intensity. All cell culture conditions described in section 2.A. above were tabulated. The results of this analysis grouped by ROI type and fixation state are summarized in Fig. 4.

Fig. 4.

Fig. 4

Box-and-whisker plots of the distribution of R2 values obtained from least-squares fitting to the Lorentzian and inverse power-law models for all cell culture conditions. Only live cells exhibited a preference for the inverse power law model (red arrow). (ECM unfixed nR=180, ECM fixed nR=36, MEC unfixed nR=153, MEC fixed nR=33, where nR is the number of manually-selected ROIs of each condition).

Figure 4 shows the coefficient of determination (R2) values obtained from the model fittings of fluctuation spectra within ROIs comprised of ECM or MEC organoids. Regions of ECM exhibited lower R2 overall, and thus were less consistent with both models in comparison to organoids. This may be due to the fact that ECM has lower OCT signal intensity, causing its diffusive motions to lie below the noise level. Within organoids, both models exhibited R2 distributions entirely above 0.90. Importantly, only the fluctuation spectra from live (unfixed) organoids exhibited a preference for the inverse power law model, with a median value of R2=0.99. The fact that formalin-fixed cells did not exhibit this preference suggests that the inverse power-law model only describes live cells. This is consistent with the picture that MEC exhibit self-organized criticality, i.e., tend toward a minimally stable state where small perturbations cause a scale-invariant response [24]. This scale-invariance, or fractal nature, can be seen by the fact that α in Eq. (2) is a unitless quantity. It is important to note that α is measured over a limited frequency band from 9–440 mHz in this study; in the absence of further data the inverse power-law description should not be extrapolated to all scales (a requirement for a true fractal object [25]). That said, in other areas of research, such as tissue mechanics, a fractal model is useful for describing viscoelasticity [26], which is typically employed in practice over a limited, experimentally-available frequency range [27].

2. Both α and M are independent of OCT signal and depth

One of the most challenging aspects of quantifying OCT images is the depth roll-off in SNR which arises from a combination of limited depth-of-focus, light attenuation, multiple light scattering [28], and in spectral-domain OCT, finite spectrometer resolution [29]. In addition, the OCT system signal strength from a given object can change from day-to-day. The robustness of the power-law exponent, α, and motility amplitude, M, were tested against these potential sources of systematic error as follows. To simulate the effect of the depth roll-off, the same MEC organoids were imaged as they were translated to five different depths in random order. To simulate the day-to-day variations in OCT signal, the reference arm power was attenuated to three different settings (nominally 100%, 75%, and 50% of maximum power) while imaging the same MEC organoids. These results were then compared against the endogenous variation in the organoids, i.e., the cross-validation results obtained when dividing image stacks into 3 groups of 100 images. For this study, two additional 3D cultures each were prepared with normal MEC or premalignant MEC, both without fibroblasts, and imaged at 1 week of culture time. The depth roll-off no=6, and the OCT signal no=7, where no is the number of MEC organoids imaged.

The results of this study are summarized in Table 1 in terms of the standard deviation (as a percentage of the average value) of α and M each. Increased standard deviations due to the added variation (either by modifying the signal or the depth) are displayed in the bottom row. Initially, we found that the endogenous variation in α and M are ~3–4% and ~6–7%, respectively. When tracking the same MEC organoids at varying signal levels, the standard deviation did not significantly increase. However, varying the image depth did cause significant increases, particularly in the standard deviation of M to a value of 12.8%. Despite this effective doubling in the error of M from that endogenous to the organoids, in the context of the variability inherent to 3D tissue cultures, the metric M is yet sufficiently quantitative to evaluate cellular functional changes, as will be shown below.

Table 1.

Standard Deviation of Motility Metrics in MEC Organoids

OCT Signal Depth Roll-Off
α M α M
Endogenous 3.1% 6.5% 3.9% 5.9%
Endogenous + Variation 3.3% 7.0% 4.9% 12.8%

3. Both α and M vary with fixation

To further validate that the proposed fluctuation spectra metrics represent cellular function, we measured α and M of MEC organoids before (“live”) and after (“fixed”) exposure to formalin fixative. The same 3D cultures as described in Section 3.A.2 were used, with no=37 for both live and fixed.

The results of this study are summarized in Figure 5. Interestingly, α increases after cell fixation, which represents that the power spectral density is relatively lower at higher frequencies. It is important to remember that the inverse power law model fitting (R2 values in Fig. 4) gets worse as cells are fixed; thus, the increase in α from ~1.6 to ~2.2 may represent more Lorentzian-like (Brownian) behavior, since a Lorentzian scales approximately as f−2 for small γ.

Fig. 5.

Fig. 5

α and M of MEC organoids composed of normal or pre-malignant cell lines were quantified before and after fixation. While there is no significant difference between cell lines, both α and M are significantly different between live and fixed cells (p<10−10 for all four comparisons). Error bars indicate standard deviation.

In contrast, the value for motility amplitude decreases after cell fixation, as expected. However, M does not exactly reach zero for fixed cells, where a non-zero offset of M≈0.11 represents the noise floor remaining after rejection of the instantaneously decorrelating noise via Eq. (4).

It is important to note that the fixation process stiffens collagenous tissue via cross-linking. This could cause some of the effects observed in Fig. 5 suppressing Brownian motions in the sample. Thus, the results of this experiment are necessary but not sufficient to show that α and M represent cellular function and not just Brownian motion. Taken together with the other evidence above (Fig. 4 showing the preference for the inverse power law only for live cells, and Fig. 3c showing excellent correspondence between regions with high motility and the positions of the organoids), it seems exceedingly likely that the signals represented by α and M represent primarily ATP-driven, and not Brownian, motions Furthermore, the use of speckle fluctuations for elucidating cellular responses to a variety of conditions has been well-established by other research groups [8,30,31]. As will be demonstrated below, these metrics are useful for indicating stromal-epithelial cell interactions in 3D co-cultures.

B. The power-law exponent reveals stromal-epithelial signaling

Interactions between stromal fibroblasts and mammary epithelial cells are implicated in breast cancer tumorigenesis, and 3D tissue co-cultures have been employed to model these interactions in controlled settings [32]. Here we hypothesized that α and M of MEC organoids would exhibit fibroblast-dependent changes in co-culture, similar to morphological changes that we previously observed in the same model system [12]. Using the large data set described in the methods (no=85, 3 measurements each), we sought to determine the dependence of α and M on each of the variations explored, including the MEC cell line (normal vs. pre-malignant), the fibroblast seed density, and the culture time. We performed linear regression using R (v. 3.1.1) according to the following model:

(α,M)=β0+β1xRMF+β2nMEC+β3t+β4mg, (5)

where xRMF is the seed density of fibroblasts in 1010/m3, nMEC is a dummy variable defined as 0 for normal MEC and 1 for pre-malignant MEC, t is the culture time in days, mg is an indicator variable for group number within the stack (as an internal control), and βi are the free-fit parameters for which estimates are summarized in Table 2. Note that each measurement, including the 3 replicate measurements of each organoid, were treated as independent in this analysis.

Table 2.

Parameter Estimates for Motility Metrics in Co-Cultures

Parameters α M
Offset β0 1.34 (0.07)*** 0.29 (0.02)***
Fibroblast seed density (1010/m3) β1 9.3 (1.1)×10−3*** −9.2 (2.8)×10−4**
Cell line (0=normal, 1=pre-malignant) β2 −0.1 (2.4)×10−2 1.5 (0.6)×10−2*
Culture Time (days) β3 3.4 (3.9)×10−3 −2.0 (1.0)×10−3*
Group (internal control, n=1–3) β4 −1.9 (1.5)×10−2 −2.3 (3.7)×10−3

Estimate (standard error) obtained using linear regression according to Eq. (5). Significance levels: ***p<0.001, **p<0.01, *p<0.05, all other p≥0.05.

The results of the linear regression underscore the importance of stromal fibroblasts in MEC motility. While the order of the repeat measurements (represented by the group number, β4) did not have any significant impact on α or M, fibroblast seed density strongly predicted α and M (p=10−14 for α, and p=10−3 for M). Interestingly, increasing fibroblast density increases α (selectively suppressing higher frequency fluctuations) while decreasing M (suppressing the overall motility amplitude). Figure 6 illustrates this dependence.

Fig. 6.

Fig. 6

Box-and-whisker plots of the distribution of α and M at each fibroblast seed density (for both cell lines and all culture times). As seed density increases, α increases strongly, while M decreases slightly. The bottom panel illustrates inverse power-law model fittings of the power spectra for representative ROIs seeded with no fibroblasts (blue) compared to 300 μL−1 fibroblasts (purple); the noise constant (n in Eq. (2)) was subtracted and spectra normalized before plotting to emphasize the effects of α. As shown, a higher value of α indicates the suppression of higher frequencies relative to lower frequencies.

The observed stromal-dependence of α and M may be an effect of increasing stiffness in the co-cultures from the fibroblasts, which was qualitatively palpable when working with the co-cultures. Importantly, we note that the co-culture gels were not allowed to detach from the container walls, and therefore shrinking of the gel volume cannot explain the increase in ECM stiffness. Rather, the fibroblasts increase tension and/or remodel the ECM thereby modulating stiffness. Mechanical changes in the ECM have previously been implicated in modifying MEC organoid behavior [33], and both soluble biochemical signals and mechanical signals from fibroblasts are known to independently affect MEC activity [15].

Interestingly, α was independent of the culture time and MEC line, while M exhibited a slightly significant (p<0.05) dependence on them (Table 2). Interestingly, pre-malignant cells exhibited higher motility amplitude than normal cells, and longer culture times tended to suppress M. The fact that the cell line is not strongly indicated is somewhat unexpected, given the strong cell line dependence of organoid morphology we previously observed in this co-culture system [12]. However, we note that in the previous study, we found that the morphological changes were larger only when both fibroblast seed density was larger and cell type was pre-malignant, suggesting an interaction between these variables. Also, our other previous work has suggested that the pre-malignant MEC line (MCF10DCIS.com) may be more susceptible to signals from fibroblasts in co-culture [32]. Therefore, in a second statistical analysis, we modeled the motility amplitude according to the following, which includes an interaction term for MECs and RMFs:

M=β0+β1xRMF+β2nMEC+β3t+β5xRMFnMEC, (6)

where the new fitting parameter, β5, represents the strength of the interaction between fibroblast density and MEC line. We omitted β4 (group number) since it was previously not significant and to limit the number of parameters in the linear regression. The results are summarized in Table 3.

Table 3.

Parameter Estimates for Motility Amplitude According to Eq. (6) in Co-Cultures

Parameters M p-value
Offset β0 0.30 (0.01) <2×10−16
Fibroblast seed density (1010/m3) β1 −1.7 (0.4)×10−3 4.2×10−6
Cell line (0=normal, 1=pre-malignant) β2 −2.3 (7.9)×10−3 0.77
Culture Time (days) β3 −2.7 (1.0)×10−3 0.0051
Fibroblast/Cell line interaction term β5 1.9 (0.6)×10−3 0.0011

Estimate (standard error) obtained using linear regression according to Eq. (6).

Using a linear model with an interaction term, Eq. (6), we find that indeed, the interaction between fibroblast seed density and MEC line is significant (p=10−3), with a higher density of fibroblasts and the pre-malignant cell line being correlated with a higher motility amplitude, M. This is interesting considering that the linear term for fibroblast seed density, β1, is negative which indicates an overall suppression of M with increasing fibroblast concentration. Thus, while the overall activity of fibroblasts is to suppress motility, pre-malignant MEC organoids are differentially modulated by their presence, exhibiting larger M in their presence than do normal MEC organoids. This finding is consistent with the previous morphological study [12], and thus we propose that the model of Eq. (6) is more appropriate than that of Eq. (5) to describe M in this co-culture system.

C. Visualization of parameterized hyperspectral images

One of the advantages of OCT is the ability to visualize the spatial heterogeneity of cellular function in 3D cultures. MEC organoids are known to develop into polarized, acinar structures over time which would be expected to cause heterogeneity in the observed power spectra. Importantly, the effect of fibroblasts from discrete locations around organoids may cause heterogeneous changes in ECM structure or tension to modify the behavior of individual cells within the organoids. Current genomic profiling methods for elucidating stromal-epithelial interactions cannot readily separate genes from epithelial and stromal cells in co-cultures (or in real tissues), and cannot reveal spatial heterogeneities within organoids. Thus, visualization of OCT-based motility metrics might provide insight that is complementary to gene expression profiling.

In traditional hyperspectral imaging [34] or in spectroscopic OCT [35], individual parameters of interest (such as wavelength, or tissue oxygenation) are often displayed on the original 2D space via a straightforward color map. Here we have reduced the temporal speckle fluctuation spectra to two parameters, α and M, to describe the spectral shape and amplitude, respectively. Because the ability to describe the spectral shape by α depends on the goodness-of-fit to the inverse power-law model (Eq. (2)), the R2 of the fitting is a third parameter that should also be monitored.

When there is a need to display multiple scalar fields (such as α, R2, and M) on the same 2D surface, sparse-glyph techniques are often preferred [36]. Here we employed the open-source platform ParaView to render these 3 motility metrics onto the original B-mode OCT image space. Because spatial averaging is needed to suppress the effects of noise on α, power spectra were averaged over a pillbox region of 9 pixels in diameter centered at each pixel within the ROIs (where pixels outside the ROI were omitted from the pillbox). This pillbox diameter is equivalent to 13.5 μm, or a cross-sectional area equivalent to that of ~2.5 MEC [12]; α and the associated R2 were then computed for each spatially-averaged spectrum, while M was computed for all pixels without spatial averaging. M was then displayed as a grayscale image, with contours from the ROIs drawn in yellow. Similar to a technique presented in [37], α was presented as a glyph of varying color. The color was linearly mapped to a double-ended blue-red color map; blue being chosen to represent small values of α that have relatively higher (blue-shifted) frequencies, and red being chosen to represent larger α that have relatively lower (red-shifted) frequencies. Importantly, the sizes of the glyphs were scaled by the R2 value to indicate greater confidence as larger glyphs. The scaling was computed according to the following nonlinear expression:

d=(R2)(log10(0.5)log10(R02)), (7)

where d is the fractional diameter of the glyph, and R02 is the target value of R2 at a fractional diameter of 50%. Here we set R02 = 0.8 to emphasize that R2<0.8 indicates a poor model fit.

The results of this visualization method are illustrated in Figure 7, where we observe that there are wide variations in motility over the MEC organoids that are not captured by the ROI-averaged analyses above. First, we note that the ROIs themselves (yellow contours) do not always represent regions of high M (white background). Although the ROIs represent regions of high light scattering from the time-averaged OCT image (Fig. 2d), clearly there are regions with high OCT signal that exhibit low motility amplitude, which could be inactive cells within the organoid. Conversely, there are also regions with low OCT signal that exhibit high M, which could represent regions that the MEC are actively extending into. We also find that there is an apparent correlation between organoid regions of low M and red-shifted power spectra (high α), an example of which is apparent in Fig. 7c, suggesting that the possible inactive cells exhibit both low M and red-shifted power spectra. Interestingly, regions of high M within organoids exhibit values of α ranging from red- to blue-shifted with varying levels of confidence (R2). Because the α values represent the response of <3 cells each, it is possible that isolated red-shifted glyphs with high M represent a small cluster of cells with a different functional state.

Fig. 7.

Fig. 7

Visualization of motility metrics on the same data as in Figs. 2 and 3, where panels (b) and (c) are close-up views of organoids (yellow arrows) in panel (a). The background grayscale image indicates M, and α is overlaid as a spherical glyph colored from blue to red to represent fluctuation spectra with more high frequency or low frequency components, respectively. Blue or red hollow glyphs indicate α values beyond the scale (<1 and >2, respectively). The size of the glyph represents R2 from the power-law fitting, with larger glyphs indicating α values with greater confidence. Yellow contour lines indicate the ROIs determined from segmentation of the time-averaged OCT image.

CONCLUSIONS

Here we present biophysical evidence of stromal-epithelial interactions in 3D breast tissue co-cultures via monitoring speckle fluctuations within the 9–440 mHz band. Significant changes in the α and M of MEC organoids are observed as a function of fibroblast seed density. The signal- and position-invariance of these metrics provide a powerful tool for measuring and visualizing cell function in 3D cultures; when using OCT systems with the same wavelength and axial resolution, we expect that these metrics will be consistent across laboratories. Coupling these techniques with OCT-based morphological analysis of the MEC organoids [12] provides a comprehensive picture of stromal-epithelial signaling. In particular, we found a similar response of the motility amplitude, M, to interactions between fibroblasts and the MEC line (normal vs. pre-malignant) as we previously did with morphological metrics including organoid size and asphericity. The ability to visualize the spatial heterogeneity of the motility of small numbers of MEC (in this study, <3 MEC per averaging window) may lead to new insight such as locating cancer stem cells [38] that cannot be resolved from gene analysis. The intuitive visualization method we propose here may allow one to utilize the already effective human visual system to identify spatial trends in organoid behavior. Importantly, all of these studies can be accomplished non-invasively, without exogenous labels, and longitudinally, on live 3D cultures.

An open question remains as to the underlying mechanism of the fluctuation signals, which fundamentally arise from non-Brownian motions of light scattering components of the cells. The relevance of the inverse power-law in this study implicates biophysical processes with scale invariance (i.e., self-similarity as described by fractals) and long-range memory, although the extension of these measurements to at least 3 decades in frequency would be needed to unambiguously prove this hypothesis [25]. The particular cellular components contributing to the light scattering signal can vary widely depending upon the cell type, where organelles such as the nucleus and mitochondria are often implicated [39]. We also expect that possible changes in cellular morphology may underlie some of the observed changes in the dynamic light scattering signals. Bulk cellular velocity may also be expected to play a role, as linear velocities of MEC in 3D culture on the order of 0.2μm/min [40] would be expected to provide speckle fluctuations at the low end (~20 mHz) of our measurement band. There is growing interest in characterizing the non-equilibrium and molecular motor-driven motions of subcellular components [4143] which, in future work, could be used to model and better understand the observed OCT fluctuation spectra. Despite these unanswered questions, efforts to profile speckle fluctuations phenotypically can provide insight and predictive value for applications such as drug screening [8], and our efforts here demonstrate its utility for stromal-epithelial systems.

Importantly, stromal-epithelial signaling affects the progression of basal-like breast cancers, a subtype of breast cancers associated with a poor prognosis. The methods developed here represent a comprehensive tool for understanding the interactions of these cells in the challenging imaging environment of 3D co-culture models that recapitulate the in vivo microenvironment.

Supplementary Material

Supplemental

Acknowledgments

National Institutes of Health (NIH) (R21 CA 179204, P41 EB 002027, U01 ES 019472); National Science Foundation (NSF) (CBET 1351474), and the Merzbacher Graduate Fellowship at the Department of Physics and Astronomy at the University of North Carolina at Chapel Hill.

We acknowledge the technical contributions of Dr. Richard Blackmon in Physics and Astronomy at UNC, and Rupninder Sandhu at the Lineberger Comprehensive Cancer Center at UNC.

Footnotes

OCIS codes: (110.4500) Optical coherence tomography; (100.4145) Motion, hyperspectral image processing; (170.1530) Cell analysis.

See Supplement 1 for supporting content.

References

  • 1.Joo C, Evans CL, Stepinac T, Hasan T, de Boer JF. Diffusive and directional intracellular dynamics measured by field-based dynamic light scattering. Opt Express. 2010;18:2858–2871. doi: 10.1364/OE.18.002858. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 2.Jeong K, Turek JJ, Nolte DD. Speckle fluctuation spectroscopy of intracellular motion in living tissue using coherence-domain digital holography. J Biomed Opt. 2010;15:030514. doi: 10.1117/1.3456369. [DOI] [PubMed] [Google Scholar]
  • 3.Lee J, Radhakrishnan H, Wu W, Daneshmand A, Climov M, Ayata C, Boas DA. Quantitative imaging of cerebral blood flow velocity and intracellular motility using dynamic light scattering-optical coherence tomography. J Cereb Blood Flow Metab. 2013;33:819–825. doi: 10.1038/jcbfm.2013.20. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 4.Burris N, Schwartz K, Tang CM, Jafri MS, Schmitt J, Kwon MH, Toshinaga O, Gu J, Brown J, Brown E, Pierson R, 3rd, Poston R. Catheter-based infrared light scanner as a tool to assess conduit quality in coronary artery bypass surgery. J Thorac Cardiovasc Surg. 2007;133:419–427. doi: 10.1016/j.jtcvs.2006.09.056. [DOI] [PubMed] [Google Scholar]
  • 5.Oldenburg AL, Chhetri RK, Hill DB, Button B. Monitoring airway mucus flow and ciliary activity with optical coherence tomography. Biomed Opt Express. 2012;3:1978–1992. doi: 10.1364/BOE.3.001978. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 6.Srinivasan VJ, Radhakrishnan H, Lo EH, Mandeville ET, Jiang JY, Barry S, Cable AE. OCT methods for capillary velocimetry. Biomed Opt Express. 2012;3:612–629. doi: 10.1364/BOE.3.000612. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 7.Lee J, Wu W, Jiang JY, Zhu B, Boas DA. Dynamic light scattering optical coherence tomography. Opt Express. 2012;20:22262–22277. doi: 10.1364/OE.20.022262. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 8.Nolte DD, An R, Turek J, Jeong K. Tissue dynamics spectroscopy for phenotypic profiling of drug effects in three-dimensional culture. Biomed Opt Express. 2012;3:2825–2841. doi: 10.1364/BOE.3.002825. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 9.An R, Merrill D, Avramova L, Sturgis J, Tsiper M, Robinson JP, Turek J, Nolte DD. Phenotypic Profiling of Raf Inhibitors and Mitochondrial Toxicity in 3D Tissue Using Biodynamic Imaging. J Biomol Screen. 2014;19:526–537. doi: 10.1177/1087057113516674. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 10.An R, Wang C, Turek J, Machaty Z, Nolte DD. Biodynamic imaging of live porcine oocytes, zygotes and blastocysts for viability assessment in assisted reproductive technologies. Biomed Opt Express. 2015;6:963–976. doi: 10.1364/BOE.6.000963. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 11.Bissell MJ, Radisky D. Putting tumours in context. Nat Rev Cancer. 2001;1:46–54. doi: 10.1038/35094059. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 12.Chhetri RK, Phillips ZF, Troester MA, Oldenburg AL. Longitudinal Study of Mammary Epithelial and Fibroblast Co-Cultures using Optical Coherence Tomography Reveals Morphological Hallmarks of Pre-Malignancy. PLoS One. 2012;7:e49148. doi: 10.1371/journal.pone.0049148. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 13.Oldenburg AL, Chhetri RK, Cooper JM, Wu WC, Troester MA, Tracy JB. Motility-, autocorrelation-, and polarization-sensitive optical coherence tomography discriminates cells and gold nanorods within 3D tissue cultures. Opt Lett. 2013;38:2923–2926. doi: 10.1364/OL.38.002923. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 14.Maller O, Martinson H, Schedin P. Extracellular matrix composition reveals complex and dynamic stromal-epithelial interactions in the mammary gland. J Mammary Gland Biol. 2010;15:301–318. doi: 10.1007/s10911-010-9189-6. [DOI] [PubMed] [Google Scholar]
  • 15.Camp JT, Elloumi F, Roman-Perez E, Rein J, Stewart DA, Harrell JC, Perou CM, Troester MA. Interactions with fibroblasts are distinct in Basal-like and luminal breast cancers. Mol Cancer Res. 2011;9:3–13. doi: 10.1158/1541-7786.MCR-10-0372. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 16.Foulkes WD, Brunet JS, Stefansson IM, Straume O, Chappuis PO, Bégin LR, Hamel N, Goffin JR, Wong N, Trudel M, Kapusta L, Porter P, Akslen LA. The Prognostic Implication of the Basal-Like (Cyclin Ehigh/p27low/p53+/Glomeruloid-Microvascular-Proliferation+) Phenotype of BRCA1-Related Breast Cancer. Cancer Res. 2004;64:830–835. doi: 10.1158/0008-5472.can-03-2970. [DOI] [PubMed] [Google Scholar]
  • 17.Mandelbrot BB, Van Ness JW. Fractional Brownian motions, fractional noises and applications. SIAM review. 1968;10:422–437. [Google Scholar]
  • 18.Johnson KR, Leight JL, Weaver VM. Demystifying the effects of a three-dimensional microenvironment in tissue morphogenesis. Methods Cell Biol. 2007;83:547–583. doi: 10.1016/S0091-679X(07)83023-8. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 19.Petersen OW, Rønnov-Jessen L, Howlett AR, Bissell MJ. Interaction with basement membrane serves to rapidly distinguish growth and differentiation pattern of normal and malignant human breast epithelial cells. Proceedings of the National Academy of Sciences. 1992;89:9064–9068. doi: 10.1073/pnas.89.19.9064. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 20.Debnath J, Muthuswamy SK, Brugge JS. Morphogenesis and oncogenesis of MCF-10A mammary epithelial acini grown in three-dimensional basement membrane cultures. Methods. 2003;30:256–268. doi: 10.1016/s1046-2023(03)00032-x. [DOI] [PubMed] [Google Scholar]
  • 21.Chhetri RK, Kozek KA, Johnston-Peck AC, Tracy JB, Oldenburg AL. Imaging three-dimensional rotational diffusion of plasmon resonant gold nanorods using polarization-sensitive optical coherence tomography. Phys Rev E Stat Nonlin Soft Matter Phys. 2011;83:040903. doi: 10.1103/PhysRevE.83.040903. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 22.Marks DL, Oldenburg AL, Reynolds JJ, Boppart SA. Digital algorithm for dispersion correction in optical coherence tomography for homogeneous and stratified media. Appl Opt. 2003;42:204–217. doi: 10.1364/ao.42.000204. [DOI] [PubMed] [Google Scholar]
  • 23.Boas DA, Bizheva KK, Siegel AM. Using dynamic low-coherence interferometry to image Brownian motion within highly scattering media. Opt Lett. 1998;23:319–321. doi: 10.1364/ol.23.000319. [DOI] [PubMed] [Google Scholar]
  • 24.Bak P, Tang C, Wiesenfeld K. Self-organized criticality. Physical Review A. 1988;38:364–374. doi: 10.1103/physreva.38.364. [DOI] [PubMed] [Google Scholar]
  • 25.Ciccotti M, Mulargia F. Pernicious effect of physical cutoffs in fractal analysis. Phys Rev E. 2002;65:037201. doi: 10.1103/PhysRevE.65.037201. [DOI] [PubMed] [Google Scholar]
  • 26.Schiessel H, Blumen A. Mesoscopic Pictures of the Sol-Gel Transition: Ladder Models and Fractal Networks. Macromolecules. 1995;28:4013–4019. [Google Scholar]
  • 27.Sinkus R, Siegmann K, Xydeas T, Tanter M, Claussen C, Fink M. MR elastography of breast lesions: Understanding the solid/liquid duality can improve the specificity of contrast-enhanced MR mammography. Magnetic Resonance in Medicine. 2007;58:1135–1144. doi: 10.1002/mrm.21404. [DOI] [PubMed] [Google Scholar]
  • 28.Thrane L, Yura HT, Andersen PE. Analysis of optical coherence tomography systems based on the extended Huygens-Fresnel principle. J Opt Soc Am A. 2000;17:484–490. doi: 10.1364/josaa.17.000484. [DOI] [PubMed] [Google Scholar]
  • 29.Nassif N, Cense B, Hyle Park B, Yun SH, Chen TC, Bouma BE, Tearney GJ, Boer JFd. In vivo human retinal imaging by ultrahigh-speed spectral domain optical coherence tomography. Opt Lett. 2004;29:480–482. doi: 10.1364/ol.29.000480. [DOI] [PubMed] [Google Scholar]
  • 30.Farhat G, Mariampillai A, Yang VXD, Czarnota GJ, Kolios MC. Detecting apoptosis using dynamic light scattering with optical coherence tomography. J Biomed Opt. 2011;16:070505–070505. doi: 10.1117/1.3600770. [DOI] [PubMed] [Google Scholar]
  • 31.Jeong K, Turek JJ, Nolte DD. Volumetric motility-contrast imaging of tissue response to cytoskeletal anti-cancer drugs. Opt Express. 2007;15:14057–14064. doi: 10.1364/oe.15.014057. [DOI] [PubMed] [Google Scholar]
  • 32.Casbas-Hernandez P, D’Arcy M, Roman-Perez E, Brauer HA, McNaughton K, Chhetri RK, Oldenburg AL, Troester MA. Role of HGF in epithelial-stromal cell interactions during progression from benign breast disease to ductal carcinoma in situ. Breast Cancer Research. 2013;15:R82. doi: 10.1186/bcr3476. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 33.Paszek MJ, Zahir N, Johnson KR, Lakins JN, Rozenberg GI, Gefen A, Reinhart-King CA, Margulies SS, Dembo M, Boettiger D, Hammer DA, Weaver VM. Tensional homeostasis and the malignant phenotype. Cancer Cell. 2005;8:241–254. doi: 10.1016/j.ccr.2005.08.010. [DOI] [PubMed] [Google Scholar]
  • 34.Lu G, Fei B. Medical hyperspectral imaging: a review. J Biomed Opt. 2014;19:010901–010901. doi: 10.1117/1.JBO.19.1.010901. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 35.Morgner U, Drexler W, Kärtner FX, Li XD, Pitris C, Ippen EP, Fujimoto JG. Spectroscopic optical coherence tomography. Opt Lett. 2000;25:111–113. doi: 10.1364/ol.25.000111. [DOI] [PubMed] [Google Scholar]
  • 36.Taylor R. Visualizing multiple fields on the same surface. Computer Graphics and Applications, IEEE. 2002;22:6–10. [Google Scholar]
  • 37.Phadke MN, Pinto L, Alabi O, Harter J, Taylor RM, II, Wu X, Petersen H, Bass SA, Healey CG. IS&T/SPIE Electronic Imaging. International Society for Optics and Photonics; 2012. Exploring ensemble visualization; p. 82940B-82940B-82912. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 38.Jordan CT, Guzman ML, Noble M. Cancer stem cells. New England Journal of Medicine. 2006;355:1253–1261. doi: 10.1056/NEJMra061808. [DOI] [PubMed] [Google Scholar]
  • 39.Drezek R, Dunn A, Richards-Kortum R. Light scattering from cells: finite-difference time-domain simulations and goniometric measurements. Appl Opt. 1999;38:3651–3661. doi: 10.1364/ao.38.003651. [DOI] [PubMed] [Google Scholar]
  • 40.Tanner K, Mori H, Mroue R, Bruni-Cardoso A, Bissell MJ. Coherent angular motion in the establishment of multicellular architecture of glandular tissues. Proceedings of the National Academy of Sciences. 2012;109:1973–1978. doi: 10.1073/pnas.1119578109. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 41.Guo M, Ehrlicher Allen J, Jensen Mikkel H, Renz M, Moore Jeffrey R, Goldman Robert D, Lippincott-Schwartz J, Mackintosh Frederick C, Weitz David A. Probing the Stochastic, Motor-Driven Properties of the Cytoplasm Using Force Spectrum Microscopy. Cell. 2014;158:822–832. doi: 10.1016/j.cell.2014.06.051. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 42.Frederick RL, Shaw JM. Moving mitochondria: establishing distribution of an essential organelle. Traffic. 2007;8:1668–1675. doi: 10.1111/j.1600-0854.2007.00644.x. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 43.Booth-Gauthier Elizabeth A, Alcoser Turi A, Yang G, Dahl Kris N. Force-Induced Changes in Subnuclear Movement and Rheology. Biophys J. 103:2423–2431. doi: 10.1016/j.bpj.2012.10.039. [DOI] [PMC free article] [PubMed] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Supplementary Materials

Supplemental

RESOURCES